Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (10)

Search Parameters:
Keywords = Nafion/MWCNTs-modified electrodes

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 6473 KiB  
Article
Research on the Detection of Hg(II) in Seawater Using GR-MWCNTs/CeO2-Modified Electrodes
by Huili Hao, Chengjun Qiu, Wei Qu, Yuan Zhuang, Xiaochun Han, Wei Tao, Yang Gu, Zizi Zhao, Haozheng Liu and Wenhao Wang
Chemosensors 2024, 12(7), 128; https://doi.org/10.3390/chemosensors12070128 - 4 Jul 2024
Cited by 4 | Viewed by 1394
Abstract
Hg(II), as an extremely hazardous heavy metal contaminant in the environment, poses a significant potential hazard to human health and ecosystems. A GR-MWCNTs-COOH/CeO2/Nafion composite film-modified glassy carbon electrode was prepared using the drop-casting method in this study. The GR-MWCNTs-COOH/CeO2/Nafion/GCE [...] Read more.
Hg(II), as an extremely hazardous heavy metal contaminant in the environment, poses a significant potential hazard to human health and ecosystems. A GR-MWCNTs-COOH/CeO2/Nafion composite film-modified glassy carbon electrode was prepared using the drop-casting method in this study. The GR-MWCNTs-COOH/CeO2/Nafion/GCE was electrochemically investigated through cyclic voltammetry (CV) and differential pulse stripping voltammetry (DPSV). Additionally, the surface morphologies of the composite film were evaluated using scanning electron microscopy (SEM). The conditions, such as buffer solution, pH, deposition potential, deposition time, modified film thickness, and Nafion content, were optimized. Under optimal experimental conditions, a good linear relationship between the peak current response of Hg(II) and its concentration in the range of 5–100 μg·L−1 was observed, with a detection limit of 0.389 μg·L−1. When it was used to detect Hg(II) in offshore seawater, the recovery rate ranged from 94.72% to 103.8%, with RSDs ≤ 5.79%. Full article
(This article belongs to the Special Issue Preparation and Application of Photoelectrochemical Sensors)
Show Figures

Figure 1

14 pages, 3865 KiB  
Brief Report
TiO2/MWCNT/Nafion-Modified Glassy Carbon Electrode as a Sensitive Voltammetric Sensor for the Determination of Hydrogen Peroxide
by Rafael Henrique de Oliveira, Daniel A. Gonçalves and Diogo Duarte dos Reis
Sensors 2023, 23(18), 7732; https://doi.org/10.3390/s23187732 - 7 Sep 2023
Cited by 13 | Viewed by 2743
Abstract
In this work we describe a straightforward approach for creating a nanocomposite comprising multiwalled carbon nanotubes (MWCNTs) and titanium dioxide (TiO2) using the hydrothermal technique, which is then characterized by scanning electron microscope (SEM), energy-dispersive X-ray spectrometer (EDS), X-ray diffraction analysis [...] Read more.
In this work we describe a straightforward approach for creating a nanocomposite comprising multiwalled carbon nanotubes (MWCNTs) and titanium dioxide (TiO2) using the hydrothermal technique, which is then characterized by scanning electron microscope (SEM), energy-dispersive X-ray spectrometer (EDS), X-ray diffraction analysis (XRD), Fourier transform infrared spectroscopy (FTIR), and thermal gravimetric analysis (TGA) to assess its properties. Nafion is employed as a reticular agent for the nanocomposite on the glassy carbon electrode (GCE), creating the MWCNT/TiO2/Nafion/GCE system. The electrochemical behavior of the system was evaluated using cyclic voltammetry, revealing its remarkable electrocatalytic activity for detecting hydrogen peroxide in water. The developed sensor showcased a broad linear response range of 14.00 to 120.00 μM, with a low detection limit of 4.00 μM. This electrochemical sensor provides a simple and highly sensitive method for detecting hydrogen peroxide in aqueous solutions and shows promising potential for various real-world applications, particularly in H2O2 monitoring. Full article
(This article belongs to the Section Chemical Sensors)
Show Figures

Figure 1

16 pages, 3588 KiB  
Article
Hybrid Nanomaterial of Graphene Oxide Quantum Dots with Multi-Walled Carbon Nanotubes for Simultaneous Voltammetric Determination of Four DNA Bases
by Qusai Hassan, Chevon Riley, Meissam Noroozifar and Kagan Kerman
Nanomaterials 2023, 13(9), 1509; https://doi.org/10.3390/nano13091509 - 29 Apr 2023
Cited by 1 | Viewed by 2467
Abstract
In this proof-of-concept study, a novel hybrid nanomaterial-based electrochemical sensor was developed for the simultaneous detection of four DNA bases. For the modification of the working electrode surface, graphene oxide quantum dots (GOQDs) were synthesized using a solvothermal method. GOQDs were then used [...] Read more.
In this proof-of-concept study, a novel hybrid nanomaterial-based electrochemical sensor was developed for the simultaneous detection of four DNA bases. For the modification of the working electrode surface, graphene oxide quantum dots (GOQDs) were synthesized using a solvothermal method. GOQDs were then used for the preparation of a hybrid nanomaterial with multi-walled carbon nanotubes (GOQD-MWCNT) using a solvothermal technique for the first time. Transmission electron microscopy (TEM) was used to characterize the GOQDs-MWCNTs. A glassy carbon electrode (GCE) was modified with the GOQDs-MWCNTs using Nafion™ to prepare a GOQD-MWCNT/GCE for the simultaneous determination of four DNA bases in phosphate buffer solution (PBS, pH 7.0) using differential pulse voltammetry (DPV). The calibration plots were linear up to 50, 50, 500, and 500 µM with a limit of detection at 0.44, 0.2, 1.6, and 5.6 µM for guanine (G), adenine (A), thymine (T) and cytosine (C), respectively. The hybrid-modified sensor was used for the determination of G, A, T, and C spiked in the artificial saliva samples with the recovery values ranging from 95.9 to 106.8%. This novel hybrid-modified electrochemical sensor provides a promising platform for the future development of a device for cost-effective and efficient simultaneous detection of DNA bases in real biological and environmental samples. Full article
(This article belongs to the Topic Fabrication of Hybrid Materials for Catalysis)
Show Figures

Figure 1

14 pages, 4533 KiB  
Article
Glucose Biosensor Based on Glucose Oxidase Immobilized on BSA Cross-Linked Nanocomposite Modified Glassy Carbon Electrode
by Yang-Yang Li, Xin-Xin Ma, Xin-Yan Song, Lin-Lin Ma, Yu-Ying Li, Xin Meng, Yu-Jie Chen, Ke-Xin Xu, Ali Akbar Moosavi-Movahedi, Bao-Lin Xiao and Jun Hong
Sensors 2023, 23(6), 3209; https://doi.org/10.3390/s23063209 - 17 Mar 2023
Cited by 13 | Viewed by 4188
Abstract
Glucose sensors based blood glucose detection are of great significance for the diagnosis and treatment of diabetes because diabetes has aroused wide concern in the world. In this study, bovine serum albumin (BSA) was used to cross-link glucose oxidase (GOD) on a glassy [...] Read more.
Glucose sensors based blood glucose detection are of great significance for the diagnosis and treatment of diabetes because diabetes has aroused wide concern in the world. In this study, bovine serum albumin (BSA) was used to cross-link glucose oxidase (GOD) on a glassy carbon electrode (GCE) modified by a composite of hydroxy fullerene (HFs) and multi-walled carbon nanotubes (MWCNTs) and protected with a glutaraldehyde (GLA)/Nafion (NF) composite membrane to prepare a novel glucose biosensor. The modified materials were analyzed by UV-visible spectroscopy (UV-vis), transmission electron microscopy (TEM), and cyclic voltammetry (CV). The prepared MWCNTs-HFs composite has excellent conductivity, the addition of BSA regulates MWCNTs-HFs hydrophobicity and biocompatibility, and better immobilizes GOD on MWCNTs-HFs. MWCNTs-BSA-HFs plays a synergistic role in the electrochemical response to glucose. The biosensor shows high sensitivity (167 μA·mM−1·cm−2), wide calibration range (0.01–3.5 mM), and low detection limit (17 μM). The apparent Michaelis–Menten constant Kmapp is 119 μM. Additionally, the proposed biosensor has good selectivity and excellent storage stability (120 days). The practicability of the biosensor was evaluated in real plasma samples, and the recovery rate was satisfactory. Full article
(This article belongs to the Section Biosensors)
Show Figures

Figure 1

10 pages, 1908 KiB  
Communication
Electrochemistry Test Strip as Platform for In Situ Detection of Blood Levels of Antipsychotic Clozapine in Finger-Pricked Sample Volume
by Mehmet Senel
Biosensors 2023, 13(3), 346; https://doi.org/10.3390/bios13030346 - 4 Mar 2023
Cited by 7 | Viewed by 2540
Abstract
With the increasing number of patients suffering from Parkinson’s disease, the importance of measuring drug levels in patient body fluids has increased exponentially, particularly for the drug clozapine. There is a growing demand for real-time analysis of biofluids on a single low-cost platform [...] Read more.
With the increasing number of patients suffering from Parkinson’s disease, the importance of measuring drug levels in patient body fluids has increased exponentially, particularly for the drug clozapine. There is a growing demand for real-time analysis of biofluids on a single low-cost platform in ultra-low fluid volumes with robustness. This study aims to measure the level of clozapine (Clz) with a portable potentiostat using a practical approach. For this purpose, we developed an inexpensive, portable platform via electrochemistry on a commercial glucose test strip (CTS). CTSs were first modified by removing the enzyme mixture from the surface of the sensing zone, which was followed by modification with Multi walled carbon nanotube (MWCNT) and Nafion. The electrochemical characteristics of CTS electrodes were investigated using cyclic voltammetry (CV) and differential voltammetry (DPV) techniques. The designed sensor displayed decent linear range, detection limit, reproducibility, and reusability results. A linear dynamic range of 0.1–5 μM clozapine was observed under optimized conditions with a good sensitivity (1.295 μA/μM) and detection limit (83 nM). Furthermore, the designed sensing electrode was used to measure the amount of Clz in real samples. Full article
(This article belongs to the Special Issue Electrochemical Sensors and Biosensors for Biomedical Applications)
Show Figures

Figure 1

17 pages, 2122 KiB  
Article
Kinetics of Oxygen Reduction Reaction of Polymer-Coated MWCNT-Supported Pt-Based Electrocatalysts for High-Temperature PEM Fuel Cell
by Md Ahsanul Haque, Md Mahbubur Rahman, Faridul Islam, Abu Bakar Sulong, Loh Kee Shyuan, Ros emilia Rosli, Ashok Kumar Chakraborty and Julfikar Haider
Energies 2023, 16(3), 1537; https://doi.org/10.3390/en16031537 - 3 Feb 2023
Cited by 7 | Viewed by 3562
Abstract
Sluggish oxygen reduction reaction (ORR) of electrodes is one of the main challenges in fuel cell systems. This study explored the kinetics of the ORR reaction mechanism, which enables us to understand clearly the electrochemical activity of the electrode. In this research, electrocatalysts [...] Read more.
Sluggish oxygen reduction reaction (ORR) of electrodes is one of the main challenges in fuel cell systems. This study explored the kinetics of the ORR reaction mechanism, which enables us to understand clearly the electrochemical activity of the electrode. In this research, electrocatalysts were synthesized from platinum (Pt) catalyst with multi-walled carbon nanotubes (MWCNTs) coated by three polymers (polybenzimidazole (PBI), sulfonated tetrafluoroethylene (Nafion), and polytetrafluoroethylene (PTFE)) as the supporting materials by the polyol method while hexachloroplatinic acid (H2PtCl6) was used as a catalyst precursor. The oxygen reduction current of the synthesized electrocatalysts increased that endorsed by linear sweep voltammetry (LSV) curves while increasing the rotation rates of the disk electrode. Additionally, MWCNT-PBI-Pt was attributed to the maximum oxygen reduction current densities at −1.45 mA/cm2 while the minimum oxygen reduction current densities of MWCNT-Pt were obtained at −0.96 mAcm2. However, the ring current densities increased steadily from potential 0.6 V to 0.0 V due to their encounter with the hydrogen peroxide species generated by the oxygen reduction reactions. The kinetic limiting current densities (JK) increased gradually with the applied potential from 1.0 V to 0.0 V. It recommends that the ORR consists of a single step that refers to the first-order reaction. In addition, modified MWCNT-supported Pt electrocatalysts exhibited high electrochemically active surface areas (ECSA) at 24.31 m2/g of MWCNT-PBI-Pt, 22.48 m2/g of MWCNT-Nafion-Pt, and 20.85 m2/g of MWCNT-PTFE-Pt, compared to pristine MWCNT-Pt (17.66 m2/g). Therefore, it can be concluded that the additional ionomer phase conducting the ionic species to oxygen reduction in the catalyst layer could be favorable for the ORR reaction. Full article
(This article belongs to the Special Issue Design, Testing and Fault Diagnosis for Fuel Cells)
Show Figures

Figure 1

16 pages, 2792 KiB  
Article
Reinforced Nafion Membrane with Ultrathin MWCNTs/Ceria Layers for Durable Proton-Exchange Membrane Fuel Cells
by Dongsu Kim, Yeonghwan Jang, Eunho Choi, Ji Eon Chae and Segeun Jang
Membranes 2022, 12(11), 1073; https://doi.org/10.3390/membranes12111073 - 29 Oct 2022
Cited by 5 | Viewed by 4135
Abstract
For further commercializing proton-exchange membrane fuel cells, it is crucial to attain long-term durability while achieving high performance. In this study, a strategy for modifying commercial Nafion membranes by introducing ultrathin multiwalled carbon nanotubes (MWCNTs)/CeO2 layers on both sides of the membrane [...] Read more.
For further commercializing proton-exchange membrane fuel cells, it is crucial to attain long-term durability while achieving high performance. In this study, a strategy for modifying commercial Nafion membranes by introducing ultrathin multiwalled carbon nanotubes (MWCNTs)/CeO2 layers on both sides of the membrane was developed to construct a mechanically and chemically reinforced membrane electrode assembly. The dispersion properties of the MWCNTs were greatly improved through chemical modification with acid treatment, and the mixed solution of MWCNTs/CeO2 was uniformly prepared through a high-energy ball-milling process. By employing a spray-coating technique, the ultrathin MWCNTs/CeO2 layers were introduced onto the membrane surfaces without any agglomeration problem because the solvent rapidly evaporated during the layer-by-layer stacking process. These ultrathin and highly dispersed MWCNTs/CeO2 layers effectively reinforced the mechanical properties and chemical durability of the membrane while minimizing the performance drop despite their non-ion-conducting properties. The characteristics of the MWCNTs/CeO2 layers and the reinforced Nafion membrane were investigated using various in situ and ex situ measurement techniques; in addition, electrochemical measurements for fuel cells were conducted. Full article
(This article belongs to the Special Issue Advanced Research on Polymer Electrolyte Membrane Fuel Cells)
Show Figures

Graphical abstract

18 pages, 3724 KiB  
Article
Electrochemical Sensing of Pb2+ and Cd2+ Ions with the Use of Electrode Modified with Carbon-Covered Halloysite and Carbon Nanotubes
by Paweł Knihnicki, Aleksandra Skrzypek, Małgorzata Jakubowska, Radosław Porada, Anna Rokicińska, Piotr Kuśtrowski, Paweł Kościelniak and Jolanta Kochana
Molecules 2022, 27(14), 4608; https://doi.org/10.3390/molecules27144608 - 19 Jul 2022
Cited by 19 | Viewed by 3260
Abstract
A novel voltammetric method for the sensitive and selective determination of cadmium and lead ions using screen-printed carbon electrodes (SPCEs) modified with carbon-deposited natural halloysite (C_Hal) and multi-walled carbon nanotubes (MWCNTs) was developed. The electrochemical properties of the proposed sensor were investigated by [...] Read more.
A novel voltammetric method for the sensitive and selective determination of cadmium and lead ions using screen-printed carbon electrodes (SPCEs) modified with carbon-deposited natural halloysite (C_Hal) and multi-walled carbon nanotubes (MWCNTs) was developed. The electrochemical properties of the proposed sensor were investigated by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV), while the morphology and structure were established by scanning electron microscopy (SEM) and X-ray powder diffraction (XRD). A two-factorial central composite design (CCD) was employed to select the composition of the nanocomposite modifying the electrode surface. The optimal measuring parameters of differential pulse anodic stripping voltammetry (DPASV) used for quantitative analysis were established with the Nelder–Mead simplex method. In the analytical investigation of Cd(II) and Pb(II) ions by DPASV, the MWCNTs/C_Hal/Nafion/SPCE exhibited a linear response in the concentration range of 0.1–10.0 µmol L−1 (for both ions) with a detection limit of 0.0051 and 0.0106 µmol L−1 for Pb(II) and Cd(II), respectively. The proposed sensor was successfully applied for the determination of metal ions in different natural water and honey samples with recovery values of 96.4–101.6%. Full article
(This article belongs to the Section Electrochemistry)
Show Figures

Graphical abstract

13 pages, 4825 KiB  
Article
Development of a Nafion/MWCNT-SPCE-Based Portable Sensor for the Voltammetric Analysis of the Anti-Tuberculosis Drug Ethambutol
by Rosa A. S. Couto and Maria Beatriz Quinaz
Sensors 2016, 16(7), 1015; https://doi.org/10.3390/s16071015 - 30 Jun 2016
Cited by 22 | Viewed by 6987
Abstract
Herein we describe the development, characterization and application of an electrochemical sensor based on the use of Nafion/MWCNT-modified screen-printed carbon electrodes (SPCEs) for the voltammetric detection of the anti-tuberculosis (anti-TB) drug ethambutol (ETB). The electrochemical behaviour of the drug at the surface of [...] Read more.
Herein we describe the development, characterization and application of an electrochemical sensor based on the use of Nafion/MWCNT-modified screen-printed carbon electrodes (SPCEs) for the voltammetric detection of the anti-tuberculosis (anti-TB) drug ethambutol (ETB). The electrochemical behaviour of the drug at the surface of the developed Nafion/MWCNT-SPCEs was studied through cyclic voltammetry (CV) and square wave voltammetry (SWV) techniques. Electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) were employed to characterize the modified surface of the electrodes. Results showed that, compared to both unmodified and MWCNTs-modified SPCEs, negatively charged Nafion/MWCNT-SPCEs remarkably enhanced the electrochemical sensitivity and selectivity for ETB due to the synergistic effect of the electrostatic interaction between cationic ETB molecules and negatively charged Nafion polymer and the inherent electrocatalytic properties of both MWCNTs and Nafion. Nafion/MWCNT-SPCEs provided excellent biocompatibility, good electrical conductivity, low electrochemical interferences and a high signal-to-noise ratio, providing excellent performance towards ETB quantification in microvolumes of human urine and human blood serum samples. The outcomes of this paper confirm that the Nafion/MWCNT-SPCE-based device could be a potential candidate for the development of a low-cost, yet reliable and efficient electrochemical portable sensor for the low-level detection of this antimycobacterial drug in biological samples. Full article
(This article belongs to the Section Chemical Sensors)
Show Figures

Graphical abstract

14 pages, 1019 KiB  
Article
Electrochemical Detection of p-Aminophenol by Flexible Devices Based on Multi-Wall Carbon Nanotubes Dispersed in Electrochemically Modified Nafion
by Graziella Scandurra, Arena Antonella, Carmine Ciofi, Gaetano Saitta and Maurizio Lanza
Sensors 2014, 14(5), 8926-8939; https://doi.org/10.3390/s140508926 - 21 May 2014
Cited by 39 | Viewed by 9855
Abstract
A conducting composite prepared by dispersing multi-walled carbon nanotubes (MWCNTs) into a host matrix consisting of Nafion, electrochemically doped with copper, has been prepared, characterized and used to modify one of the gold electrodes of simply designed electrochemical cells having copier grade transparency [...] Read more.
A conducting composite prepared by dispersing multi-walled carbon nanotubes (MWCNTs) into a host matrix consisting of Nafion, electrochemically doped with copper, has been prepared, characterized and used to modify one of the gold electrodes of simply designed electrochemical cells having copier grade transparency sheets as substrates. Electrical measurements performed in deionized water show that the Au/Nafion/Au-MWCNTs–Nafion:Cu cells can be successfully used in order to detect the presence of p-aminophenol (PAP) in water, without the need for any supporting electrolyte. The intensity of the redox peaks arising when PAP is added to deionized water is found to be linearly related to the analyte in the range from 0.2 to 1.6 µM, with a detection limit of 90 nM and a sensitivity of 7 µA·(µM−1)·cm−2. Full article
(This article belongs to the Section Chemical Sensors)
Show Figures

Back to TopTop