Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (5)

Search Parameters:
Keywords = Legionella rubrilucens

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
9 pages, 248 KB  
Article
Legionella spp. Colonization in Water Systems of Hotels Linked with Travel-Associated Legionnaires’ Disease
by Antonios Papadakis, Maria Keramarou, Dimosthenis Chochlakis, Vassilios Sandalakis, Varvara A. Mouchtouri and Anna Psaroulaki
Water 2021, 13(16), 2243; https://doi.org/10.3390/w13162243 - 17 Aug 2021
Cited by 10 | Viewed by 5843
Abstract
Hotel water systems colonized with Legionella spp. have been the source of travel-associated Legionnaires’ disease, and cases, clusters and outbreaks continue to be reported worldwide each year. A total of 132 hotels linked with travel-associated Legionnaires’ disease, as reported through the European Legionnaires’ [...] Read more.
Hotel water systems colonized with Legionella spp. have been the source of travel-associated Legionnaires’ disease, and cases, clusters and outbreaks continue to be reported worldwide each year. A total of 132 hotels linked with travel-associated Legionnaires’ disease, as reported through the European Legionnaires’ Disease Surveillance Network, were inspected and tested for Legionella spp. during 2000–2019 by the public health authorities of the island of Crete (Greece). A total of 3311 samples were collected: 1885 (56.93%) from cold water supply systems, 1387 (41.89%) from hot water supply systems, 37 (1.12%) were swab samples and two (0.06%) were soil. Of those, 685 (20.69%), were collected from 83 (62.89%) hotels, testing positive (≥50 CFU/L) for Legionella pneumophila) serogroups 1–10, 12–14 and non-pneumophila species (L. anisa, L. erythra, L. tusconensis, L. taurinensis, L. birminghamensis, L. rubrilucens, L. londiniesis, L. oakridgensis, L. santicrusis, L. brunensis, L. maceacherii). The most frequently isolated L. pneumophila serogroups were 1 (27.92%) and 3 (17.08%). Significantly higher isolation rates were obtained from hot water supply systems (25.96%) versus cold water systems (16.98%) and swab samples (13.51%). A Relative Risk (R.R.) > 1 (p < 0.0001) was calculated for hot water temperature <55 °C (R.R.: 4.43), chlorine concentrations <0.2 mg/L (R.R.: 2.69), star ratings <4 (R.R.: 1.73) and absence of Water Safety Plan implementation (R.R.: 1.57). Full article
(This article belongs to the Special Issue Water Quality and the Public Health)
17 pages, 836 KB  
Article
How Molecular Typing Can Support Legionella Environmental Surveillance in Hot Water Distribution Systems: A Hospital Experience
by Luna Girolamini, Silvano Salaris, Jessica Lizzadro, Marta Mazzotta, Maria Rosaria Pascale, Tiziana Pellati and Sandra Cristino
Int. J. Environ. Res. Public Health 2020, 17(22), 8662; https://doi.org/10.3390/ijerph17228662 - 21 Nov 2020
Cited by 7 | Viewed by 3924
Abstract
In this study, we aimed to associate the molecular typing of Legionella isolates with a culture technique during routine Legionella hospital environmental surveillance in hot water distribution systems (HWDSs) to develop a risk map able to be used to prevent nosocomial infections and [...] Read more.
In this study, we aimed to associate the molecular typing of Legionella isolates with a culture technique during routine Legionella hospital environmental surveillance in hot water distribution systems (HWDSs) to develop a risk map able to be used to prevent nosocomial infections and formulate appropriate preventive measures. Hot water samples were cultured according to ISO 11731:2017. The isolates were serotyped using an agglutination test and genotyped by sequence-based typing (SBT) for Legionella pneumophila or macrophage infectivity potentiator (mip) gene sequencing for non-pneumophila Legionella species. The isolates’ relationship was phylogenetically analyzed. The Legionella distribution and level of contamination were studied in relation to temperature and disinfectant residues. The culture technique detected 62.21% of Legionella positive samples, characterized by L. pneumophila serogroup 1, Legionella non-pneumophila, or both simultaneously. The SBT assigned two sequence types (STs): ST1, the most prevalent in Italy, and ST104, which had never been isolated before. The mip gene sequencing detected L. anisa and L. rubrilucens. The phylogenetic analysis showed distinct clusters for each species. The distribution of Legionella isolates showed significant differences between buildings, with a negative correlation between the measured level of contamination, disinfectant, and temperature. The Legionella molecular approach introduced in HWDSs environmental surveillance permits (i) a risk map to be outlined that can help formulate appropriate disinfection strategies and (ii) rapid epidemiological investigations to quickly identify the source of Legionella infections. Full article
(This article belongs to the Special Issue Environmental Bacterial Pathogens and Human Health)
Show Figures

Figure 1

21 pages, 794 KB  
Article
Advances in Legionella Control by a New Formulation of Hydrogen Peroxide and Silver Salts in a Hospital Hot Water Network
by Luna Girolamini, Ada Dormi, Tiziana Pellati, Paolo Somaroli, Davide Montanari, Andrea Costa, Francesca Savelli, Andrea Martelli, Antonella Grottola, Giulia Fregni Serpini and Sandra Cristino
Pathogens 2019, 8(4), 209; https://doi.org/10.3390/pathogens8040209 - 29 Oct 2019
Cited by 21 | Viewed by 5766
Abstract
Legionella surveillance is an important issue in public health, linked to the severity of disease and the difficulty associated with eradicating this bacterium from the water environment. Different treatments are suggested to reduce Legionella risk, however long-term studies of their efficiency are lacking. [...] Read more.
Legionella surveillance is an important issue in public health, linked to the severity of disease and the difficulty associated with eradicating this bacterium from the water environment. Different treatments are suggested to reduce Legionella risk, however long-term studies of their efficiency are lacking. This study focused on the activity of a new formulation of hydrogen peroxide and silver salts, WTP828, in the hospital hot water network (HWN) to contain Legionella contamination during two years of treatment. The effectiveness of WTP828 was tested measuring physical-chemical and microbiological parameters such as Legionella, Pseudomonas aeruginosa (P. aeruginosa), and a heterotopic plate count (HPC) at 36 °C. Legionella isolates were identified by serotyping and genotyping. WTP 828 induced a reduction in Legionella–positive sites (60% to 36%) and contamination levels (2.12 to 1.7 log10 CFU/L), with isolates belonging to L. pneumophila SG1 (ST1 and ST104), L. anisa and L. rubrilucens widely distributed in HWN. No relevant contamination was found for other parameters tested. The long-term effect of WTP828 on Legionella containment suggest the easy and safe application of this disinfectant, that combined with knowledge of building characteristics, an adequate environmental monitoring and risk assessment plan, become the key elements in preventing Legionella contamination and exposure. Full article
(This article belongs to the Special Issue Legionella Contamination in Water Environment)
Show Figures

Graphical abstract

11 pages, 1109 KB  
Article
Antimicrobial Effect of Visible Light—Photoinactivation of Legionella rubrilucens by Irradiation at 450, 470, and 620 nm
by Julian Schmid, Katharina Hoenes, Petra Vatter and Martin Hessling
Antibiotics 2019, 8(4), 187; https://doi.org/10.3390/antibiotics8040187 - 15 Oct 2019
Cited by 25 | Viewed by 6300
Abstract
Despite the high number of legionella infections, there are currently no convincing preventive measures. Photoinactivation with visible light is a promising new approach and the photoinactivation sensitivity properties of planktonic Legionella rubrilucens to 450, 470, and 620 nm irradiation were thus investigated and [...] Read more.
Despite the high number of legionella infections, there are currently no convincing preventive measures. Photoinactivation with visible light is a promising new approach and the photoinactivation sensitivity properties of planktonic Legionella rubrilucens to 450, 470, and 620 nm irradiation were thus investigated and compared to existing 405 nm inactivation data for obtaining information on responsible endogenous photosensitizers. Legionella were streaked on agar plates and irradiated with different doses by light emitting diodes (LEDs) of different visible wavelengths. When irradiating bacterial samples with blue light of 450 nm, a 5-log reduction could be achieved by applying a dose of 300 J cm−2, whereas at 470 nm, a comparable reduction required about 500 J cm−2. For red irradiation at 620 nm, no inactivation could be observed, even at 500 J cm−2. The declining photoinactivation sensitivity with an increasing wavelength is consistent with the assumption of porphyrins and flavins being among the relevant photosensitizers. These results were obtained for L. rubrilucens, but there is reason to believe that its inactivation behavior is similar to that of pathogenic legionella species. Therefore, this photoinactivation might lead to new future concepts for legionella reduction and prevention in technical applications or even on or inside the human body. Full article
(This article belongs to the Special Issue Photodynamic Therapy in the Inactivation of Microorganisms)
Show Figures

Figure 1

15 pages, 554 KB  
Article
Legionella spp. Risk Assessment in Recreational and Garden Areas of Hotels
by Antonios Papadakis, Dimosthenis Chochlakis, Vassilios Sandalakis, Maria Keramarou, Yannis Tselentis and Anna Psaroulaki
Int. J. Environ. Res. Public Health 2018, 15(4), 598; https://doi.org/10.3390/ijerph15040598 - 26 Mar 2018
Cited by 36 | Viewed by 14817
Abstract
Several Travel-associated Legionnaires’ disease (TALD) cases occur annually in Europe. Except from the most obvious sites (cooling towers and hot water systems), infections can also be associated with recreational, water feature, and garden areas of hotels. This argument is of great interest to [...] Read more.
Several Travel-associated Legionnaires’ disease (TALD) cases occur annually in Europe. Except from the most obvious sites (cooling towers and hot water systems), infections can also be associated with recreational, water feature, and garden areas of hotels. This argument is of great interest to better comprehend the colonization and to calculate the risk to human health of these sites. From July 2000–November 2017, the public health authorities of the Island of Crete (Greece) inspected 119 hotels associated with TALD, as reported through the European Legionnaires’ Disease Surveillance Network. Five hundred and eighteen samples were collected from decorative fountain ponds, showers near pools and spas, swimming pools, spa pools, garden sprinklers, drip irrigation systems (reclaimed water) and soil. Of those, 67 (12.93%), originating from 43 (35.83%) hotels, tested positive for Legionella (Legionella pneumophila serogroups 1, 2, 3, 6, 7, 8, 13, 14, 15 and non-pneumophila species (L. anisa, L. erythra, L. taurinensis, L. birminghamensis, L. rubrilucens). A Relative Risk (R.R.) > 1 (p < 0.0001) was calculated for chlorine concentrations of less than 0.2 mg/L (R.R.: 54.78), star classification (<4) (R.R.: 4.75) and absence of Water Safety Plan implementation (R.R.: 3.96). High risk (≥104 CFU/L) was estimated for pool showers (16.42%), garden sprinklers (7.46%) and pool water (5.97%). Full article
(This article belongs to the Special Issue Recreational Water Illnesses)
Show Figures

Figure 1

Back to TopTop