Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (9)

Search Parameters:
Keywords = µCBCT

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
13 pages, 989 KB  
Article
Cone-Beam Computed Tomography Laser-Guided Transthoracic Needle Biopsy for Pulmonary Lesions in a Hybrid Operating Room: Feasibility Study by an Interventional Pulmonologist
by Lun-Che Chen, Po-Keng Su, Geng-Ning Hu, Shwetambara Malwade, Wen-Yuan Chung, Ling-Kai Chang and Shun-Mao Yang
Diagnostics 2026, 16(2), 226; https://doi.org/10.3390/diagnostics16020226 - 10 Jan 2026
Cited by 1 | Viewed by 1255
Abstract
Background/Objectives: Percutaneous transthoracic needle biopsy (PTNB) using advanced navigation techniques is increasingly performed; however, pulmonologists’ experience remains limited. This study reports an interventional pulmonologist’s initial experience with cone-beam computed tomography (CBCT) laser-guided PTNB and the diagnostic performance for lesions with diameters greater than [...] Read more.
Background/Objectives: Percutaneous transthoracic needle biopsy (PTNB) using advanced navigation techniques is increasingly performed; however, pulmonologists’ experience remains limited. This study reports an interventional pulmonologist’s initial experience with cone-beam computed tomography (CBCT) laser-guided PTNB and the diagnostic performance for lesions with diameters greater than or less than 20 mm. Methods: We retrospectively analysed the data of patients who underwent PTNB in a C-arm CBCT-equipped hybrid operating room between July 2020 and March 2024. All patients underwent the biopsy procedure under local anaesthesia. This was preceded by an initial 3D scan for planning of the needle route, followed by coaxial needle insertion. A post-procedural scan was also performed to identify complications. Results: Seventy-seven patients were enrolled in the study. The median distances of the needle path from the skin to the pleura and from the pleura to the lesion were 33.4 mm and 31.7 mm, respectively. The median number of tissue samplings was 4.9 ± 1.8. The median operating room duration was 51.5 ± 25.7 min, respectively. The median total dose area product was 8485.4 ± 5819.9 µGym2. The sensitivity and specificity of our study findings were 93.3% (56/60) and 100%, while the accuracy was 94.8% (73/77). The overall complication rate was 13%. Conclusions: PTNB procedure by pulmonologists is a feasible and safe, single-operator workflow in a hybrid operating room. It can be performed under CBCT laser guidance with a similar diagnostic yield, acceptable radiation exposure and procedure duration, and minimal or manageable complications. Full article
(This article belongs to the Special Issue Advances in Interventional Pulmonology)
Show Figures

Figure 1

16 pages, 1913 KB  
Article
Evaluation of Ultra-Low-Dose CBCT Protocols to Investigate Vestibular Bone Defects in the Context of Immediate Implant Planning: An Ex Vivo Study on Cadaver Skulls
by Mats Wernfried Heinrich Böse, Jonas Buchholz, Florian Beuer, Stefano Pieralli and Axel Bumann
J. Clin. Med. 2025, 14(12), 4196; https://doi.org/10.3390/jcm14124196 - 12 Jun 2025
Cited by 2 | Viewed by 2020
Abstract
Background/Objectives: This ex vivo study aimed to evaluate the diagnostic performance of ultra-low-dose (ULD) cone-beam computed tomography (CBCT) protocols in detecting vestibular bone defects for immediate implant planning, using intraoral scan (IOS) data as a reference. Methods: Four CBCT protocols (ENDO, A, B, [...] Read more.
Background/Objectives: This ex vivo study aimed to evaluate the diagnostic performance of ultra-low-dose (ULD) cone-beam computed tomography (CBCT) protocols in detecting vestibular bone defects for immediate implant planning, using intraoral scan (IOS) data as a reference. Methods: Four CBCT protocols (ENDO, A, B, C) were applied to four dried human skulls using a standardized setup and a single CBCT unit (Planmeca ProMax® 3D Mid, Planmeca Oy, Helsinki, Finland). All scans were taken at 90 kV, with varying parameters: (1) ENDO (40 × 50 mm, 75 µm, 12 mA, 80–120 µSv, 15 s), (2) A (50 × 50 mm, 75 µm, 9 mA, 20–40 µSv, 5 s), (3) B (100 × 60 mm, 150 µm, 7.1 mA, 22–32 µSv, 5 s), and (4) C (100 × 100 mm, 200 µm, 7.1 mA, 44 µSv, 4 s). Vestibular root surfaces of single-rooted teeth (FDI regions 15–25 and 35–45) were digitized via IOS and exported as STL files. CBCT datasets were superimposed using 3D software (Blender 2.79), and surface defects were measured and compared using one-sample t-tests and Bland–Altman analysis. The level of significance was set at p < 0.05. Results: A total of 330 vestibular surfaces from 66 teeth were analyzed. Compared to the IOS reference, protocols ENDO and A showed minimal differences (p > 0.05). In contrast, protocols B and C exhibited statistically significant deviations (p < 0.05). Protocol B demonstrated a mean difference of −0.477 mm2 with limits of agreement (LoA) from −2.04 to 1.09 mm2 and significant intra-rater variability (p < 0.05). Protocol C revealed a similar mean deviation (−0.455 mm2) but a wider LoA (−2.72 to 1.81 mm2), indicating greater measurement variability. Overall, larger voxel sizes were associated with increased random error, although deviations remained within clinically acceptable limits. Conclusions: Despite statistical significance, deviations for protocols B and C remained within clinically acceptable limits. ULD CBCT protocols are, thus, suitable for evaluating vestibular bone defects with reduced radiation exposure. Full article
(This article belongs to the Special Issue Emerging Technologies for Dental Imaging)
Show Figures

Figure 1

14 pages, 2840 KB  
Article
Enhancing Cone-Beam CT Image Quality in TIPSS Procedures Using AI Denoising
by Reza Dehdab, Andreas S. Brendlin, Gerd Grözinger, Haidara Almansour, Jan Michael Brendel, Sebastian Gassenmaier, Patrick Ghibes, Sebastian Werner, Konstantin Nikolaou and Saif Afat
Diagnostics 2024, 14(17), 1989; https://doi.org/10.3390/diagnostics14171989 - 9 Sep 2024
Cited by 2 | Viewed by 2315
Abstract
Purpose: This study evaluates a deep learning-based denoising algorithm to improve the trade-off between radiation dose, image noise, and motion artifacts in TIPSS procedures, aiming for shorter acquisition times and reduced radiation with maintained diagnostic quality. Methods: In this retrospective study, TIPSS patients [...] Read more.
Purpose: This study evaluates a deep learning-based denoising algorithm to improve the trade-off between radiation dose, image noise, and motion artifacts in TIPSS procedures, aiming for shorter acquisition times and reduced radiation with maintained diagnostic quality. Methods: In this retrospective study, TIPSS patients were divided based on CBCT acquisition times of 6 s and 3 s. Traditional weighted filtered back projection (Original) and an AI denoising algorithm (AID) were used for image reconstructions. Objective assessments of image quality included contrast, noise levels, and contrast-to-noise ratios (CNRs) through place-consistent region-of-interest (ROI) measurements across various critical areas pertinent to the TIPSS procedure. Subjective assessments were conducted by two blinded radiologists who evaluated the overall image quality, sharpness, contrast, and motion artifacts for each dataset combination. Statistical significance was determined using a mixed-effects model (p ≤ 0.05). Results: From an initial cohort of 60 TIPSS patients, 44 were selected and paired. The mean dose-area product (DAP) for the 6 s acquisitions was 5138.50 ± 1325.57 µGy·m2, significantly higher than the 2514.06 ± 691.59 µGym2 obtained for the 3 s series. CNR was highest in the 6 s-AID series (p < 0.05). Both denoised and original series showed consistent contrast for 6 s and 3 s acquisitions, with no significant noise differences between the 6 s Original and 3 s AID images (p > 0.9). Subjective assessments indicated superior quality in 6 s-AID images, with no significant overall quality difference between the 6 s-Original and 3 s-AID series (p > 0.9). Conclusions: The AI denoising algorithm enhances CBCT image quality in TIPSS procedures, allowing for shorter scans that reduce radiation exposure and minimize motion artifacts. Full article
(This article belongs to the Section Machine Learning and Artificial Intelligence in Diagnostics)
Show Figures

Figure 1

7 pages, 697 KB  
Article
Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates
by Mohamed M. Abuzaid, Wiam Elshami, Deepa Jayachandran, Noushad Korappil and Huseyin O. Tekin
Tomography 2022, 8(6), 2939-2945; https://doi.org/10.3390/tomography8060247 - 14 Dec 2022
Cited by 12 | Viewed by 3118
Abstract
This study aimed to address the knowledge gap in assessing the radiation doses from cone beam computed tomography (CBCT) procedures, establishing a typical value, and estimating effective and organ doses. A total of 340 patients aged 18–80 years were included in this study. [...] Read more.
This study aimed to address the knowledge gap in assessing the radiation doses from cone beam computed tomography (CBCT) procedures, establishing a typical value, and estimating effective and organ doses. A total of 340 patients aged 18–80 years were included in this study. Organ doses were estimated using VirtualDose IR software. The typical values were based on median values estimated as 1000 mGy cm2. The mean ED (µSv) per procedure was 149.5 ± 56, and the mean of the peak skin dose during the CBCT examination was 39.29 mGy. The highest organ dose was received by the salivary glands (2.71 mGy), the extrathoracic region (1.64 mGy), thyroid (1.24 mGy) and eyes (0.61 mGy). The patients’ doses were higher than in previous studies. Staff awareness, education, training and dose optimisation are highly recommended. With the establishment of local DRLs, patient dosages can be reduced successfully without compromising image quality. Full article
Show Figures

Figure 1

16 pages, 3082 KB  
Article
Deep Learning Based Automated Orthotopic Lung Tumor Segmentation in Whole-Body Mouse CT-Scans
by Wouter R. P. H. van de Worp, Brent van der Heyden, Georgios Lappas, Ardy van Helvoort, Jan Theys, Annemie M. W. J. Schols, Frank Verhaegen and Ramon C. J. Langen
Cancers 2021, 13(18), 4585; https://doi.org/10.3390/cancers13184585 - 13 Sep 2021
Cited by 18 | Viewed by 4493
Abstract
Lung cancer is the leading cause of cancer related deaths worldwide. The development of orthotopic mouse models of lung cancer, which recapitulates the disease more realistically compared to the widely used subcutaneous tumor models, is expected to critically aid the development of novel [...] Read more.
Lung cancer is the leading cause of cancer related deaths worldwide. The development of orthotopic mouse models of lung cancer, which recapitulates the disease more realistically compared to the widely used subcutaneous tumor models, is expected to critically aid the development of novel therapies to battle lung cancer or related comorbidities such as cachexia. However, follow-up of tumor take, tumor growth and detection of therapeutic effects is difficult, time consuming and requires a vast number of animals in orthotopic models. Here, we describe a solution for the fully automatic segmentation and quantification of orthotopic lung tumor volume and mass in whole-body mouse computed tomography (CT) scans. The goal is to drastically enhance the efficiency of the research process by replacing time-consuming manual procedures with fast, automated ones. A deep learning algorithm was trained on 60 unique manually delineated lung tumors and evaluated by four-fold cross validation. Quantitative performance metrics demonstrated high accuracy and robustness of the deep learning algorithm for automated tumor volume analyses (mean dice similarity coefficient of 0.80), and superior processing time (69 times faster) compared to manual segmentation. Moreover, manual delineations of the tumor volume by three independent annotators was sensitive to bias in human interpretation while the algorithm was less vulnerable to bias. In addition, we showed that besides longitudinal quantification of tumor development, the deep learning algorithm can also be used in parallel with the previously published method for muscle mass quantification and to optimize the experimental design reducing the number of animals needed in preclinical studies. In conclusion, we implemented a method for fast and highly accurate tumor quantification with minimal operator involvement in data analysis. This deep learning algorithm provides a helpful tool for the noninvasive detection and analysis of tumor take, tumor growth and therapeutic effects in mouse orthotopic lung cancer models. Full article
(This article belongs to the Special Issue Preclinical Models of Solid Malignancies)
Show Figures

Figure 1

13 pages, 2181 KB  
Article
Effects of Histamine Receptor Antagonist Cetirizine on Orthodontic Tooth Movement
by Gregor Sperl, Johanna Gattner, James Deschner, Michael Wolf, Peter Proff, Agnes Schröder and Christian Kirschneck
Biomedicines 2020, 8(12), 583; https://doi.org/10.3390/biomedicines8120583 - 8 Dec 2020
Cited by 7 | Viewed by 3816
Abstract
Many patients regularly take histamine receptor antagonists, such as cetirizine, to prevent allergic reactions, but these antiallergic drugs may have inadvertent effects on orthodontic treatment. In previous studies, histamine has been shown to modulate the sterile inflammatory reaction underlying orthodontic tooth movement. Pertinent [...] Read more.
Many patients regularly take histamine receptor antagonists, such as cetirizine, to prevent allergic reactions, but these antiallergic drugs may have inadvertent effects on orthodontic treatment. In previous studies, histamine has been shown to modulate the sterile inflammatory reaction underlying orthodontic tooth movement. Pertinent effects of histamine antagonization via cetirizine during orthodontic treatment, however, have not been adequately investigated. We thus treated male Fischer344 rats either with tap water (control group) or cetirizine by daily oral gavage corresponding to the clinically used human dosage adjusted to the rat metabolism (0.87 mg/kg) or to a previously published high dosage of cetirizine (3 mg/kg). Experimental anterior movement of the first upper left molar was induced by insertion of a nickel-titanium (NiTi) coil spring (0.25 N) between the molar and the upper incisors. Cone-beam computed tomography (CBCT), micro-computed tomography (µCT) images, as well as histological hematoxylin-eosin (HE), and tartrate-resistant acid phosphatase (TRAP) stainings were used to assess the extent of tooth movement, cranial growth, periodontal bone loss, root resorptions, and osteoclast activity in the periodontal ligament. Both investigated cetirizine dosages had no impact on the weight gain of the animals and, thus, animal welfare. Neither the extent of tooth movement, nor cranial growth, nor root resorption, nor periodontal bone loss were significantly influenced by the cetirizine dosages investigated. We, thus, conclude that histamine receptor antagonist cetirizine can be used during orthodontic treatment to prevent allergic reactions without clinically relevant side effects on orthodontic tooth movement. Full article
(This article belongs to the Special Issue Models for Oral Biology Research)
Show Figures

Graphical abstract

11 pages, 2032 KB  
Article
Designing and Fabricating Nano-Structured and Micro-Structured Radiation Shields for Protection against CBCT Exposure
by Kiana Nikeghbal, Zahra Zamanian, Shoaleh Shahidi, Gianrico Spagnuolo and Parisa Soltani
Materials 2020, 13(19), 4371; https://doi.org/10.3390/ma13194371 - 30 Sep 2020
Cited by 24 | Viewed by 4357
Abstract
Researchers have always been interested in finding new and effective materials for protection against radiation. This experimental study aimed to design and fabricate new types of nano-material and micro-material based shields against the ionizing effect of cone beam computed tomography (CBCT) X-rays. To [...] Read more.
Researchers have always been interested in finding new and effective materials for protection against radiation. This experimental study aimed to design and fabricate new types of nano-material and micro-material based shields against the ionizing effect of cone beam computed tomography (CBCT) X-rays. To fabricate a flexible prototype, we added dioctyl phthalate (DOP) oil to emulsion polyvinyl chloride (PVC) powder. The paste was mixed and dispersed. Then, nano- and micro-powders of WO3 and Bi2O3 were added to the paste, with the weight ratio of 20% PVC, 20% DOP, and 60% nano- and micro-metals. Using an ultrasonic mixer, the polymer matrix and metals were mixed and a paste with a thick texture was developed. The resultant paste was poured into glass molds and the molds were then heated in an oven. After cooling, the resultant sheets were selected for further experiments. A CBCT unit and dosimeter were used to evaluate the characterization and X-ray shielding properties of the fabricated prototypes. The half-value layers (HVL) for nano-WO3, micro-WO3, nano-Bi2O3, and micro-Bi2O3 were 0.0390, 0.0524, 0.0351, and 0.0374 cm, respectively. In addition, the linear attenuation coefficient (µ) for these materials were 17.77, 13.20, 19.71, and 18.5 cm−1, respectively. The findings indicate that nano-structured samples are more effective in the attenuation of X-ray energy. The nano-structured WO3 prototype was nearly 34% more efficient in attenuating radiation compared to the micro-structured WO3 prototype. This difference in nano- and micro-structured Bi2O3 prototypes was 6.5%. Full article
(This article belongs to the Special Issue Current and Future Trends in Dental Materials)
Show Figures

Figure 1

14 pages, 3201 KB  
Article
Evaluation of a Novel Liquid Fiducial Marker, BioXmark®, for Small Animal Image-Guided Radiotherapy Applications
by Kathryn H. Brown, Mihaela Ghita, Giuseppe Schettino, Kevin M. Prise and Karl T. Butterworth
Cancers 2020, 12(5), 1276; https://doi.org/10.3390/cancers12051276 - 18 May 2020
Cited by 15 | Viewed by 4372
Abstract
BioXmark® (Nanovi A/S, Denmark) is a novel fiducial marker based on a liquid, iodine-based and non-metallic formulation. BioXmark® has been clinically validated and reverse translated to preclinical models to improve cone-beam CT (CBCT) target delineation in small animal image-guided radiotherapy (SAIGRT). [...] Read more.
BioXmark® (Nanovi A/S, Denmark) is a novel fiducial marker based on a liquid, iodine-based and non-metallic formulation. BioXmark® has been clinically validated and reverse translated to preclinical models to improve cone-beam CT (CBCT) target delineation in small animal image-guided radiotherapy (SAIGRT). However, in phantom image analysis and in vivo evaluation of radiobiological response after the injection of BioXmark® are yet to be reported. In phantom measurements were performed to compare CBCT imaging artefacts with solid fiducials and determine optimum imaging parameters for BioXmark®. In vivo stability of BioXmark® was assessed over a 5-month period, and the impact of BioXmark® on in vivo tumour response from single-fraction and fractionated X-ray exposures was investigated in a subcutaneous syngeneic tumour model. BioXmark® was stable, well tolerated and detectable on CBCT at volumes ≤10 µL. Our data showed imaging artefacts reduced by up to 84% and 89% compared to polymer and gold fiducial markers, respectively. BioXmark® was shown to have no significant impact on tumour growth in control animals, but changes were observed in irradiated animals injected with BioXmark® due to alterations in dose calculations induced by the sharp contrast enhancement. BioXmark® is superior to solid fiducials with reduced imaging artefacts on CBCT. With minimal impact on the tumour growth delay, BioXmark® can be implemented in SAIGRT to improve target delineation and reduce set-up errors. Full article
(This article belongs to the Special Issue Animal Models for Radiotherapy Research)
Show Figures

Figure 1

12 pages, 2558 KB  
Article
Continuous Measurement of Three-Dimensional Root Canal Curvature Using Cone-Beam Computed and Micro-Computed Tomography: A Comparative Study
by Michael Kucher, Martin Dannemann, Niels Modler, Dominik Haim, Christian Hannig and Marie-Theres Weber
Dent. J. 2020, 8(1), 16; https://doi.org/10.3390/dj8010016 - 6 Feb 2020
Cited by 12 | Viewed by 4815
Abstract
The knowledge of root canal curvature is crucial regarding the prevention of ledge formation, root perforation and the possibility of endodontic instruments’ fracture during endodontic treatments. Therefore, a quantification method of the root canal curvature as well as the applicability of diagnostically relevant [...] Read more.
The knowledge of root canal curvature is crucial regarding the prevention of ledge formation, root perforation and the possibility of endodontic instruments’ fracture during endodontic treatments. Therefore, a quantification method of the root canal curvature as well as the applicability of diagnostically relevant tomographic three-dimensional (3D) imaging data is necessary. Hereby, cone-beam computed tomography (CBCT) images and micro-computed tomography (µCT) data of distal root canals were analysed concerning the continuous three-dimensional curvature of human mandibular molars ( n = 50). The curvature of the canal’s three-dimensional centre line was determined by evaluating the tomographic images. The centroids of each root canal slice were identified and approximated by spline curves to obtain the centre line and therefore, its curvature. Comparing the results evaluated from CBCT and µCT images, minimum radii of curvature of 2.6 mm and 2.1 mm were determined, respectively. The observation of the centre line demonstrated the requirement of the three-dimensional imaging data from CBCT and µCT for a reliable curvature analysis. Conclusively, the evaluation of CBCT and µCT images results in comparable radii of curvature. Thus, the application of the introduced method in combination with CBCT applied to patient cases could offer an important preliminary diagnostical step to prevent endodontic treatment complications. Full article
Show Figures

Figure 1

Back to TopTop