Reviewer 1 Report
1 It is not clear why the authors combined the thermoelectric and magnetocaloric systems together. The potential applications of the system should be discussed.
2 The authors used a lot of parameters in Section 2. A schematic should be provided with all the parameters and symbols for easier understanding.
3 The plots in Figure 2, 6, 7, 8 are very confusing.
4 The presentation of the results and discussions need to be improved. The figures and discussions are very confusing, and it is very difficult to get the logic of the work.
Author Response
Please see the attachment
Author Response File: Author Response.pdf
Reviewer 2 Report
I think the authors may need to provide real materials for the Figure 1, sandwich structure, and provide the experimental data to verify the simulations.
Author Response
Please see the attachment
Author Response File: Author Response.pdf
Reviewer 3 Report
This review report has been removed from the review record as it did not conform with MDPI’s standards (https://www.mdpi.com/reviewers#_bookmark11).
Round 2
Reviewer 2 Report
The authors have addressed the comments and suggestions by the reviewers, i think it can be accepted now.