Next Article in Journal
From Diagnostics to Prescribing: Antibiotic and Diagnostic Stewardship in Contemporary UTI Care
Previous Article in Journal
The Role of the Urinary and Gut Microbiome in Bladder Cancer: Emerging Insights and Clinical Implications
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Novel Dual-Action Pump Shows Promise to Reduce Intra-Renal Pressure and Improve Irrigant Flow in Flexible Ureteroscopy

1
Division of Urology, Groote Schuur Hospital, University of Cape Town, Cape Town 7700, South Africa
2
Division of Urology, Department of Surgery, Frere Hospital and Faculty of Medicine and Health Sciences, Walter Sisulu University, East London 5200, South Africa
*
Author to whom correspondence should be addressed.
Submission received: 25 January 2026 / Revised: 3 March 2026 / Accepted: 10 April 2026 / Published: 16 April 2026

Abstract

Background/Objective: To describe a novel dual-action pump (DAP) which is hypothesised to reduce mean intrarenal pressure (IRP) and increase irrigation flow during flexible ureterorenoscopy (fURS). The DAP incorporates a low-volume, user-controlled pumping/suctioning unit, to precisely control fluid boluses into the upper urinary tract via a ureterorenoscope and simultaneously draws out an identical volume of the delivered irrigant via a syphoning UAS. This human cadaveric study aims to assess the DAP’s impact on IRP and the irrigant flow rate compared to a traditional UAS. Methods: Twelve fresh frozen human cadaver renal units were studied in situ. An 11/13 UAS was placed under fluoroscopic guidance and a fURS was introduced. Continuous pressure was monitored. The DAP and syphoning UAS were compared to a conventional irrigation system in terms of IRP and irrigant flow at variable irrigant fluid heights and during fluid bolus administration. Results: The mean IRP was reduced by 79–141%. Maximum IRP was reduced by up to 180%. The mean irrigation flow rate was improved by 44–86%. The small sample size of 12 limits the results obtained. Conclusions: The novel DAP system shows promise in reducing intra-renal pressure and improving irrigant flow in flexible ureteroscopy.
Keywords: intra-renal pressure; retrograde intra-renal surgery; renal calculi; ureteral access sheath intra-renal pressure; retrograde intra-renal surgery; renal calculi; ureteral access sheath

Share and Cite

MDPI and ACS Style

Wellmann, M.; John, J.; Lazarus, J. Novel Dual-Action Pump Shows Promise to Reduce Intra-Renal Pressure and Improve Irrigant Flow in Flexible Ureteroscopy. Uro 2026, 6, 11. https://doi.org/10.3390/uro6020011

AMA Style

Wellmann M, John J, Lazarus J. Novel Dual-Action Pump Shows Promise to Reduce Intra-Renal Pressure and Improve Irrigant Flow in Flexible Ureteroscopy. Uro. 2026; 6(2):11. https://doi.org/10.3390/uro6020011

Chicago/Turabian Style

Wellmann, Mark, Jeff John, and John Lazarus. 2026. "Novel Dual-Action Pump Shows Promise to Reduce Intra-Renal Pressure and Improve Irrigant Flow in Flexible Ureteroscopy" Uro 6, no. 2: 11. https://doi.org/10.3390/uro6020011

APA Style

Wellmann, M., John, J., & Lazarus, J. (2026). Novel Dual-Action Pump Shows Promise to Reduce Intra-Renal Pressure and Improve Irrigant Flow in Flexible Ureteroscopy. Uro, 6(2), 11. https://doi.org/10.3390/uro6020011

Article Metrics

Back to TopTop