Next Article in Journal
Recycling Volcanic Lapillus as a Supplementary Cementitious Material in Sustainable Mortars
Previous Article in Journal
Life Cycle Assessment of Biomass Waste and Coal Co-Firing: Advancing Circular Economy in Energy Production
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Quantifying Cotton Content in Post-Consumer Polyester/Cotton Blend Textiles via NIR Spectroscopy: Current Attainable Outcomes and Challenges in Practice

1
Chair of Waste Processing Technology and Waste Management, Department of Environmental and Energy Process Engineering, Technical University of Leoben, 8700 Leoben, Austria
2
Josef Ressel Centre “Recovery Strategies for Textiles”, University of Applied Sciences Wiener Neustadt, Biotech Campus Tulln, 3430 Tulln, Austria
3
Department of Chemistry, Institute of Chemistry of Renewable Resources, BOKU University, 3430 Tulln, Austria
*
Author to whom correspondence should be addressed.
Recycling 2025, 10(4), 152; https://doi.org/10.3390/recycling10040152
Submission received: 18 June 2025 / Revised: 22 July 2025 / Accepted: 28 July 2025 / Published: 1 August 2025

Abstract

Rising volumes of textile waste necessitate the development of more efficient recycling systems, with a primary focus on the optimization of sorting technologies. Near-infrared (NIR) spectroscopy is a state-of-the-art method for fiber identification; however, its accuracy in quantifying textile blends, particularly common polyester/cotton blend textiles, still requires refinement. This study explores the potential and limitations of NIR spectroscopy for quantifying cotton content in post-consumer textiles. A lab-scale NIR sorter and a handheld NIR spectrometer in complementary wavelength ranges were applied to a diverse range of post-consumer textile samples to test model accuracies. Results show that the commonly assumed 10% accuracy threshold in industrial sorting can be exceeded, especially when excluding textiles with <35% cotton content. Identifying and excluding the range of non-linearity significantly improved the model’s performance. The final models achieved an RMSEP of 6.6% and bias of −0.9% for the NIR sorter and an RMSEP of 3.1% and bias of −0.6% for the handheld NIR spectrometer. This study also assessed how textile characteristics—such as color, structure, product type, and alkaline treatment—affect spectral behavior and model accuracy, highlighting their importance for refining quantification when high-purity inputs are needed. By identifying current limitations and potential sources of errors, this study provides a foundation for improving NIR-based models.

1. Introduction

The global textile industry continues to expand, largely driven by the growing demand caused mainly by fast fashion and a switch in consumer behaviors that prioritize frequent apparel turnover over durability. As a result, textile waste is increasing at an alarming rate. On average, textiles’ consumption in the EU increased from 17 kg per person in 2019 to 19 kg per person in 2022 [1]. Therefore, the EU has taken several actions to address the growing textile waste problem. One of the initial steps was the introduction of mandatory separate collection for textile waste from 1 January 2025, as well as emphasizing prevention, reuse, and recycling over disposal [2]. Additionally, the EU Strategy for Sustainable and Circular Textiles has been published, with the aim of making textiles more durable, repairable, reusable, and recyclable by 2030. The key steps in reaching those goals shall be the introduction of a mandatory extended producer responsibility (EPR) system; different eco-design requirements; a ban on the destruction of unsold textiles; and boosting sorting, reuse, and recycling infrastructure [3]. Supporting these measurements, the EU also foresees the rollout of a Digital Product Passport (DPP) as part of the Deliver Proven Traceability initiative. These tolls provide verified digital records of material composition and product history. Accurate fiber content detection, especially for polyester/cotton blends, is essential for enabling traceability in textile circularity [4].
This has also brought more attention to recycling non-reusable textiles. Currently, the state of textile recycling is still not optimal, with only low levels of textile waste being effectively recycled. A major bottleneck is the lack of efficient sorting systems, which are essential for sorting textiles by fiber type and content, as subsequent recycling processes are specifically tailored to different types of textile materials. This is especially challenging for blended textiles such as polyester/cotton blends (also known as polycotton), which is the most common blend, accounting for approximately 9% of all textile waste [5]. An investigation of post-consumer textile waste in Vienna, Austria has further highlighted the prevalence of cotton- and polyester-based materials, indicating that polyester/cotton blends represent a significant share of the waste stream [6]. As the fast fashion industry continues to expand, the use of inexpensive, mass-produced materials like polyester/cotton blend is expected to increase even further. While this blend offers cost advantages for both manufacturers and consumers, its blended fiber composition poses significant challenges for recycling. Conventional recycling methods struggle to effectively process blended fibers, making polyester/cotton blend difficult to handle. Although significant research efforts are currently underway in the field of polyester/cotton separation and recycling, these approaches depend on accurate information about the fiber composition of the input material [7,8,9,10,11,12]. Recent reviews highlight the need for efficient sorting solutions; in this context, NIR spectroscopy presents itself as a promising technology, offering fast, non-invasive, real-time measurements without the need for sample preparation [13,14]. It is already being used in textile sorting applications, and continuous research supports its potential [15,16,17,18,19,20]. When it comes to its capabilities for quantitative measurements, however, research is still in its infancy. This is particularly true for research focusing on post-consumer textiles (textile waste), where real-world variability presents additional complexity. Yao et al. [21] analyzed waste-derived polyester/cotton blends using a portable NIR spectrometer, achieving a high prediction accuracy of up to 97% and errors within ±3%. However, the analysis was limited to specific wavelength ranges of 1400–1700 and 1900–2200 nm and was conducted under fully controlled laboratory conditions. More application-focused experiments were performed by Becker et al. [16]. Their study showed promising results (4% prediction error) for identifying polyester-rich textiles and demonstrated a scalable application of NIR in a real-world recycling facility. Nevertheless, the focus remained primarily on polyester detection, with a low number of samples and without introducing the influence of material heterogeneity in waste textiles. Mäkelä et al. [22] introduced hyperspectral NIR imaging combined with machine vision to predict the polyester content. Their model achieved prediction errors between 2.2% and 4.5% and offered spatially resolved fiber content maps, which are valuable for identifying textile heterogeneity. However, the study focused on polyester quantification in and post- as well as pre-consumer textiles without further investigating other influences on quantification. The study performed by Paz and Sousa [23] additionally compared NIR and MIR spectroscopy, reporting lower calibration errors for NIR (of 3.3%) and validation errors of 3.6%. However, it is important to note that their analysis was conducted on controlled samples rather than on post-consumer textiles, limiting its applicability to real-world textile waste streams.
Building on the existing research, this study introduces a more comprehensive approach to cotton content quantification in post-consumer polyester/cotton blended textiles using NIR spectroscopy, with a focus on practical implementation across different usage contexts. This study combines two types of NIR spectroscopic instruments: an industrial NIR sorting system of lab-scale size and a handheld NIR spectrometer. Each device was selected to serve a specific purpose within the study’s framework. The NIR sorter represents an automated solution already integrated into textile sorting facilities. It enables rapid and contactless measurements of materials and reflects real-world industrial conditions. In contrast, the handheld NIR spectrometer offers a portable, low-cost alternative that is increasingly used for on-site textile assessment, particularly in settings with limited infrastructure or for quality checks supporting the automated systems.
The combination of both instruments, each covering different but complementary regions of the NIR spectrum, enables a more comprehensive evaluation of spectral features relevant to cotton and polyester across distinct wavelength ranges. By including both instruments, this study investigates how differences in spectral coverage, measurement geometry, and resolution influence cotton content quantification under similar conditions. To ensure comparability, both instruments measured the same set of post-consumer textile samples, which exhibited varying material characteristics. Unlike previous studies that primarily focused on controlled laboratory conditions or employed only a single type of NIR instrument, this study integrates two complementary setups, each representing different practical use cases and spectral capabilities. This approach bridges the gap between experimental accuracy and industrial relevance while also addressing the complexity of analyzing heterogeneous post-consumer textile waste.
To simulate real-world automated sorting conditions, a lab-scale NIR sorter (911–1677 nm) was utilized. This setup enabled evaluation of the performance of NIR-based quantification under conditions closely replicating those found in industrial environments. In parallel, a handheld NIR spectrometer (1596–2396 nm) was used to explore the capabilities and limitations of portable spectroscopy, which are increasingly being considered for random material characterization on site. This dual-method approach aided the analysis of the limitations and challenges met by the current NIR technology for quantification of cotton in polyester/cotton post-consumer textiles, comparing accuracy across different spectral ranges and use cases.
The samples used in the study consisted of post-consumer textiles, both apparel and home textiles, collected from various sources containing 100% cotton, 100% polyester and polyester/cotton blends of 20–95% cotton. In total, 190 samples were used, of which 79 as training set for model training and 111 as test set for model validations. To improve the reliability of the quantification, the samples used in these experiments exhibited different textile characteristics—such as surface color, textile structure, and application types—to address the complexity and variability of real-world post-consumer textile waste and to better understand their impact on quantification performance.
Additionally, many textiles undergo mercerization, the most common form of alkaline treatment, whose influence on quantification was therefore also examined. Alkaline treatment, commonly in the form of mercerization, is a widely used method for modifying the physical and chemical properties of textiles, particularly cellulose-based materials such as cotton and cotton-rich textiles (including polyester/cotton blends), in order to enhance properties such as strength, dye shade, and increased luster [24,25]. Alkaline treatment is commonly used in high-quality apparel and home textiles, yet its presence in post-consumer textiles is often undocumented and difficult to identify. Given its potential impact on fiber structure and spectral properties, understanding the effects of such treatments is essential for model development. To address this, measurements were performed using controlled laboratory samples with a constant cotton content of 50% to simulate conditions potentially present in post-consumer textiles and to analyze the influence of alkaline treatment on the quantification of polyester/cotton blends.

2. Results and Discussion

2.1. Spectral Acquisition and Model Training

The acquired spectra for each training sample reveal differences in the intensities of characteristic peaks associated with polyester and cotton. Figure 1 shows the spectral trend between 0 and 100% cotton, where the spectra shown in lighter colors represent lower cotton content, while darker-colored spectra correspond to higher percentages of cotton. As the cotton content in the blend increases, the intensity of the cotton characteristic peaks also increases. Prior to analysis, the spectra were pre-processed using a first derivative followed by smoothing for the NIR sorter and SNV normalization after derivation for the handheld NIR spectrometer. The pre-processed spectra are plotted as the first derivative of absorbance, commonly referred to as the gradient (y-axis, in ALU/nm) versus wavelength (x-axis). Gradient indicates how the signal changes with wavelength, and ALU/nm (absorbance line units per nanometer) reflects the rate of change in the absorbance-like signal, enhancing variations in spectral features across the range and thus allowing relative evaluation.
For the NIR sorter, the most prominent absorption bands for cotton appear in the ranges of 1130–1200 nm, corresponding to the second overtone of C-H stretching; 1355–1470 nm, attributed to the first overtone of O-H stretching and combination bands of O-H bending and C-O stretching; and 1600–1650 nm, associated with combination bands involving O-H and C-H vibrations. These are typical of cellulose-based materials [26,27]. For the handheld NIR spectrometer, cotton shows absorption bands at 1860–1950 nm and 2000–2100 nm, primarily resulting from combination bands of O-H stretching and C-O stretching vibrations [28]. A similar trend is observed for polyester, with key absorption regions in the 1100–1150 nm range for the NIR sorter, related to the second overtone of C-H stretching and the 1380–1630 nm range, corresponding to overtones and combination bands involving C-H and C=O groups [16,26]. For the handheld spectrometer, polyester shows characteristic bands at 1600–1700 nm and 2100–2200 nm, primarily linked to combination bands of C=O stretching and C-H deformation, especially from ester functional groups that are characteristic of polyester [23,29].
Based on acquired spectral differences, PLS models were trained. The full modeling procedure, including definitions of evaluation metrics such as R2, RMSEC, RMSEP and bias are described in Section 3.2. For the NIR sorter, the model using three LVs was selected to minimize model complexity while maintaining acceptable predictive performance, resulting in an RMSEC of 8.6% and an R2 of 0.93. These results demonstrate robustness and reliable predictive performance of the model. The use of three LVs indicates that the model effectively captures the essential spectral variance required for accurate quantification, while minimizing the risk of overfitting.
PLS models were developed for both instruments using the same training set and number of LVs to ensure consistent analysis. This configuration yielded an RMSEC of 8.1% and an R2 of 0.94, indicating slightly improved predictive accuracy while maintaining a consistent level of model complexity.

2.2. Model Validation

The models were validated using an independent test set, with performance metrics calculated based on a single train–test split. No repeated cross-validation was applied. This approach was intentionally chosen to simulate a realistic operational scenario, reflecting typical deployment conditions where models are trained once and used in practice without repeated retraining or resampling. The results are not intended for direct comparison between the instruments but rather to identify the respective challenges and limitations associated with each setup.
The model developed for the NIR sorter demonstrated its validation performance by yielding an R2 of 0.98, an RMSEP of 7.4%, and bias of 1.8%. Although it may appear unexpected, the RMSEP was lower than RMSEC in this case. The training (calibration) set was deliberately constructed to cover a broad range of variability, reflecting the heterogeneity of post-consumer textile waste. The independent test (validation) set, compiled separately, also exhibited high variability but was well represented within the broader calibration domain. This likely enabled the model to generalize effectively to new samples, resulting in a lower prediction error (RMSEP) than the calibration error (RMSEC). While this outcome is uncommon, it has already been discussed in the literature, particularly when the characteristics of the test samples fall within the variability modeled by the calibration set [30].
While Becker et al. achieved predictive performance R2 of 0.99 and RMSEP of 3.6%, our model reflects slightly lower correlation and a higher prediction error, likely due to the greater variability introduced by increased sample diversity, which may have offset the advantages of a larger training and test set. Nonetheless, the results indicate a fair balance between predicted and reference values, with adequate average prediction performance, especially when addressing the complexity of heterogenous post-consumer textile samples. Additionally, the calculated bias suggests a slight overestimation of cotton content by 1.8%. While the RMSEP is comparatively higher, the low bias suggests that the model’s errors are largely random rather than systematic, suggesting that the model maintains a reasonable balance. The validation results acquired using the NIR sorter are shown in Figure 2, which presents a plot of predicted versus reference values.
Method validation for the handheld NIR spectrometer resulted in an R2 of 0.99, an RMSEP of 8.1%, and bias of 3.5%. Figure 3 provides a visualization of the validation results acquired using the handheld NIR spectrometer. The model shows a relatively high R2 accompanied by increased RMSEP and bias values, indicating higher prediction errors. This may be due to increased variability within the measurements, as well as a smaller and inconsistent sampling area, as each sample was measured at only five points. However, the scatter of the predicted cotton content around the reference line (reference cotton content) is lower, though the RMSEP and bias remain higher, likely influenced by the presence of outliers at 0% cotton content. In particular, the predicted cotton content for samples containing 0% cotton (i.e., 100% polyester) is notably overestimated, a trend further supported by the analysis of the average bias and RMSEP across different cotton content levels (Table 1).
A degree of scatter from the line of identity is noticeable in the measurements from both instruments, with scattering differing across cotton content levels. To better understand this behavior, an additional targeted assessment was conducted by calculating RMSEP and bias within specific cotton content ranges for each instrument. The results are presented in Table 1 to provide a structured overview of performance across different content intervals.
The RMSEP and bias values differ between the two instruments, with the NIR sorter showing higher average prediction errors and systematic deviation than the handheld NIR spectrometer. The RMSEP values for both instruments indicate generally balanced performance, although the NIR sorter results in higher error for most of the contents. When focusing specifically on polyester/cotton blends, the results stay in the same range per instrument. However, more distinct differences are present in samples composed entirely of either polyester or cotton. In these cases, cotton samples show the lowest prediction error, while polyester samples show the highest. This suggests that the presence of cotton in the sample contributes to improved quantification accuracy, rather than the model simply detecting the absence of cotton.
In contrast, the bias results show a clear difference, indicating better stability in the model using handheld NIR spectroscopy. This may be due to various factors but mainly due to the difference in how each device interacts with the sample surface. The handheld NIR spectrometer measures directly in contact with the sample, whereas the NIR sorter operates from a distance.
The results obtained from both instruments suggest potential non-linearity in the 0–35% cotton range, as this effect appears in the measurements from both setups. However, identifying the exact point of deviation is challenging due to the limited availability of samples within this range. Although polyester/cotton textiles containing 35% cotton are relatively common, samples with lower cotton content are comparatively rare. This scarcity is consistent with trends in Western Europe, where cotton remains a dominant fiber, accounting for 43% of non-reusable textiles [5]. Due to the small number of samples in the low-percentage-cotton range (under 35%), the statistical reliability of any interpretation in this interval is limited and must be viewed with caution. Consequently, it is debatable whether this range should be considered relevant for inclusion in the cotton content quantification model.
When samples containing 0–34% cotton were excluded, the models’ accuracies improved. The improvement was especially pronounced in the results acquired with the handheld NIR spectrometer, where the RMSEP dropped significantly from 8.1% to 3.1% and bias from +3.5% to −0.6%. In contrast, the improvement observed for the NIR sorter was smaller, though still notable, with the RMSEP dropping from 7.4% to 6.6% and bias from 1.8% to −0.9%.
To test the linearity of the quantification in the range of 0–35% cotton content, additional models focusing exclusively on this segment were trained to test possible changes in quantification accuracy. The validation results for both instruments are presented in Figure 4. The results still exhibit a certain level of variability, with a calculated RMSEP of 3.3% and bias of 1.6% for the NIR sorter and RMSEP of 5.2% and bias of 2.1% for the handheld NIR spectrometer. Overall, some non-linearity appears to be present in the 0–35% cotton content range; however, the 0% cotton samples show lower absolute predictive errors when evaluated using the 0–35%-range model, compared to the full-range (0–100%) model. Given the limited sample size and the practical application-oriented design of the study, which was based on a single train–test split, resampling-based validation methods such as p-values or confidence intervals were not applied. This evaluation strategy reflects a realistic use-case scenario and prioritizes operational relevance. Accordingly, the currently applied threshold of <35% cotton content reflects a pragmatic decision based on empirical observations and observed model behavior, rather than a validated or universally applicable boundary. The main finding is the detection of non-linearity, which may begin at a lower cotton content and merits further investigation.
Some of the samples containing 0% cotton (i.e., 100% polyester) continue to show significant dispersion when measured with both instruments. This is mainly the case for samples having a shiny surface or low material thickness, which are often semi-transparent (i.e., scarves). Shiny surfaces can scatter light and disrupt NIR sensor performance, which can then lead to misclassification. Therefore, matte and rough surfaces are preferable as they reflect light diffusely, providing more consistent and reliable spectral data for classification [31,32,33,34]. For thin or semi-transparent materials, partial light transmission may lead to minor background signal contributions. However, thin textiles also reflect less light overall, leading to weaker signals and reduced spectral quality.

2.3. Influence of Different Textile Characteristics on Quantification

Since the PLS model’s accuracy results varied across samples, an additional analysis was conducted to determine whether specific textile characteristics influence quantification outcomes. This influence was assessed primarily by analyzing variations in absolute errors for both the NIR sorter and the handheld NIR spectrometer. Additionally, because handheld measurements were taken from five distinct points on each sample, the standard deviation of these measurements was calculated to assess whether certain textile characteristics correlate with increased measurement variability.
The analysis for potential influencing factors included surface design (unicolor versus patterned), textile structure (knitted versus woven fabrics), and application type (apparel versus home textiles). Material composition was also analyzed to determine whether samples made of 100% cotton, 100% polyester, or polyester/cotton blends differ in accuracy when distinguishing between blends and non-blends as well as between only cotton or only polyester. Finally, the impact of various product categories of apparel textiles (e.g., t-shirts, scarves, and pants) on quantification accuracy was evaluated. All results are presented in Figure 5.
The differences in surface design between the absolute errors of unicolored and patterned textiles reveal higher absolute errors for patterned samples when measured with both instruments, although the error is slightly lower for the handheld NIR spectrometer. The standard deviation results for surface design confirm that patterned samples result in higher variability than unicolored ones. The detected higher variability in patterned samples may be due to their non-homogeneous nature, as patterns often involve multiple dyes which deliver varying spectral response or cause light-scattering effects, Nevertheless, this difference remains below 1% in terms of absolute error.
Textile structure appears to influence quantification with varying intensity across the two analyzed instruments. While no significant difference was observed between knitted and woven fabrics when measuring with NIR sorter, the handheld NIR spectrometer showed slightly higher absolute errors and greater variability for woven fabrics. This suggests that textile structure may influence measurement stability when measured with a handheld NIR spectrometer, possibly due to differences in sensor contact and light interaction.
Regarding the application type, significant variation is evident across both instruments. The NIR sorter shows higher absolute errors for home textiles, while the handheld NIR spectrometer performs least accurately on apparel. Home textiles also show greater standard deviation, likely due to their common use of woven fabrics. In contrast, the higher error for apparel may come from greater variability in different treatments and dyeing processes, which are often less standardized. These differences highlight how structural and chemical variations across application types can influence NIR signal response and prediction accuracy. Differentiating between categories allows for a more targeted evaluation of model robustness, supporting future adaptation of quantification methods to the specific characteristics and challenges of each stream.
The significantly higher absolute error for 100% polyester samples is not unexpected, as it is consistent with overall quantification results. However, the standard deviation does not show a notable discrepancy from other material types. In contrast, 100% cotton textile samples exhibit the lowest absolute error when measured with both instruments. Notably, the handheld NIR spectrometer achieves higher accuracy, with an absolute error of 1.51% and a low standard deviation of 0.93%, performing significantly better than the NIR sorter in this context. Polyester/cotton blend samples, as expected, show higher absolute error than only cotton, with values of 7.50% for the NIR sorter and 3.01% for the handheld NIR spectrometer. These results suggest that the handheld NIR spectrometer may offer better accuracy for polyester/cotton blends as well. Despite a standard deviation of 2.9%, the handheld NIR spectrometer still performed adequately. Although cotton is typically considered more spectrally variable due to its moisture sensitivity and biological variability, it showed the lowest prediction error in this study. In contrast, the higher error for polyester samples may be linked to physical characteristics such as glossy surfaces and reduced thickness, both of which can negatively affect NIR signal quality, especially in handheld measurement. These effects, including how shiny surfaces scatter light and thin textiles yield weaker signals, are described earlier in the text (see Section 3.2).
The analysis of product categories in relation to quantification accuracy revealed several notable patterns. The NIR sorter demonstrated low sensitivity to variations, delivering consistent results across different cotton content categories. However, both instruments identified the same product categories—namely, sportswear, scarves, and jackets—as exhibiting higher absolute errors and standard deviations. Higher errors were expected for sportswear, which predominantly consists of polyester, a material previously identified as challenging for accurate quantification. Similar challenges are present when analyzing scarves and jackets as they often contain either 100% polyester or high-percentage polyester blends and typically feature a shiny surface, further complicating accurate quantification. On the other hand, t-shirts and pants showed the lowest absolute error and standard deviation for both instruments. This can be attributed to their material composition, as these categories typically comprise either 100% or high-percentage cotton blends.

2.4. Influence of Alkaline Treatment on Quantification

The influence of alkaline treatment under varying molarities was tested using previously trained quantification models, and the resulting absolute and relative errors per sample are shown in Figure 6. A noticeable increase is observed in absolute errors (Figure 6a) at higher molarity levels. For the NIR sorter, the shift becomes particularly evident between 4 and 5 M, marking a distinct change in performance. In contrast, the handheld NIR spectrometer does not exhibit a clear trend; however, a similar increase in error is apparent starting from 5 M. This observation is further confirmed by the acquired spectra (Figure 7).
Research focusing on analysis of the transformation of cellulose I to cellulose II during alkaline treatment with NaOH indicates that this transition typically occurs starting at concentrations around 15% by weight, corresponding to approximately 3.75 M in our case, aligning with the acquired results [35]. Although such high-concentration treatments are not common in most everyday apparel textiles, they occur in specific textile categories, particularly high-quality garments (premium apparel textiles), home textiles such as towels and bed linens, formal wear such as shirts, and occasionally denim [36]. Consequently, these textiles, despite constituting a smaller fraction of post-consumer textile waste, still appear in sorting systems. These observations may also explain the increased absolute error observed when measuring woven post-consumer textiles, especially with the handheld NIR spectrometer, as this category frequently includes formal shirts, which are commonly subjected to alkaline treatments to enhance their properties.
Although the results herein confirm the recognition and influence of the transition, a significant discrepancy is evident when analyzing relative error, where the NIR sorter tends to indicate a higher cotton content with the rise of molarity, while the handheld NIR spectrometer identifies a lower cotton content. This may be due to varying spectral responses in different wavelength ranges as well as disparities between the two instruments. The NIR sorter, operating in a lower wavelength range, is more sensitive to surface-level structural changes and moisture-related functional groups like O-H, which are affected by alkaline treatment. Treated cotton samples exhibit stronger O-H absorption bands, particularly around 1450 and 1580 nm, likely due to rearrangement of hydrogen bonding during the transition from cellulose I to II. These structural changes can also lead to shifts or the broadening of absorption features in the 1450–1480 nm region (O-H first overtone) and increased absorbance near 1580 nm. In contrast, polyester lacks these O-H features [37,38]. Consequently, with increased levels of alkaline treatment, the NIR sorter detects a more pronounced cotton signal, leading to higher estimation of cotton content.
In contrast, the handheld NIR spectrometer, operating in a higher wavelength range, captures more defined combination bands, making it more sensitive to spectral disruptions caused by alkaline treatment. Notable changes are observed around 2100, 2250, and 2280 nm, where band shifts and intensity reductions occur in treated samples. These changes likely result from increased crystalline disorder and hydrogen bond rearrangement, which affect cellulose-specific absorption features and can contribute to underestimation of cotton content. These differences highlight how alkaline treatment alters the cotton spectrum, increasing certain O-H features while disrupting others, depending on the spectral region.
In summary, alkaline treatment of cotton alters its NIR spectral behavior by modifying hydrogen bonding and crystalline structure. The NIR sorter, which measures shorter wavelengths, detects stronger cotton signals after treatment due to increased O-H absorption. On the other hand, the handheld spectrometer, which works at higher wavelengths, shows weaker signals from cotton because the treatment disrupts key spectral features. These differences reflect the transition from cellulose I to cellulose II and highlight the need to interpret results differently depending on the instrument used.
Although the two instruments respond in opposite directions, the discrepancy in their errors begins at a similar threshold. This shows that the performance of both instruments is affected by alkaline treatment, though in different ways, and may therefore influence the sorting efficiency. Consequently, future work shall compare spectroscopic data from alkaline-treated cotton samples to cellulose II type fibers such as viscose and lyocell to identify similarities and false-positive results based on conversion of cellulose I to II.

2.5. Targeted Qualitative Assessment of Samples Producing Inaccurate or No Results

In addition to the thin samples and fabrics with shiny surfaces, which yielded the poorest results, three additional categories of polyester/cotton samples could also be identified as challenging. These samples were either excluded from the quantification process or selected for an additional investigation during discussion of the results. The decision to further examine certain samples was based on criteria such as unusually high prediction errors, inconsistent classification results, or unexpected spectral characteristics that deviated significantly from the majority of the results. The three categories are (a) visually heterogeneous samples, (b) light grey textiles, and (c) sweatshirts and sweatpants with a multilayered structure. Figure 8 shows one example from each of the identified categories.
The results from the category of visually heterogenous samples (a) display measured variability related to fabric color, pattern, and localized material composition differences. This effect is particularly pronounced when using the handheld NIR spectrometer due to its point-based measurements, which yield variable results depending on the color of the specific area being measured. Color-dependent behavior can lead to significant variability in the quantified fiber composition. While averaging multiple handheld measurements can, in many cases, approximate the reference cotton content, this is only valid when all color variants present are included in the measurements. If certain colored areas are omitted, the resulting average may strongly deviate from the reference cotton content. This is particularly challenging in samples with highly patterned surfaces, when numerous colors and fine-scale patterns increase the likelihood of uneven measurements. In some cases, this deviation may be minor, being only a few percentage points, and it may still fall within acceptable quantification limits. Dye–matrix interactions may also affect spectral variation, especially if certain dyes alter absorbance or scattering, potentially impacting prediction accuracy [39]. However, extreme cases can occur, such as the one shown in Figure 8a, where the white area of the sample contains 0% cotton and the red area 100% cotton content despite the chemical analysis and label indicating 50% cotton content. This discrepancy is not necessarily due to the color itself but more likely reflects the presence of two distinct materials combined in one garment and visually separated by color. This composition was correctly quantified by the NIR sorter, which analyzed the entire sample area and calculated an average value for accurate quantification. Although this approach is generally more representative, it relies on comprehensive coverage of all corresponding parts of the samples. If some areas or colors remain undetected due to uneven presentation of the sample to the sensor, the resulting quantification may also be inaccurate. The highlighted challenge shows the importance of representative measurements, capturing all the color variances in order to achieve accurate quantification.
The light grey-colored textiles (n = 4) (b) were identified as a sample category frequently associated with inaccurate quantification results, with predicted cotton content averaging between 10 and 15% despite reference values above 50%. While not all grey textiles showed this issue, it was most pronounced in lighter shades. This is likely due to the presence of carbon black pigments, which are known to absorb strongly in the NIR range, leading to weak or unusable spectra [40]. In our case, black textiles did not show similar errors, suggesting that not all black textiles were dyed with carbon black; some may have used synthetic dyes that are more compatible with NIR. In contrast, the poor performance of certain light grey samples suggests that carbon black or similar pigments may have been used, resulting in low reflectance and limited spectral contrast, which hinder accurate quantification. This limitation affects not only quantification but also the reliability of material identification.
Sweatshirt and sweatpant materials (c) present an additional challenge due to their layered structure, typically consisting of different inner and outer layers. While both sides are often made from polyester/cotton blends, their compositions can differ significantly, with deviations of up to 30% observed in our measurements. The outer layer usually has a higher cotton content, while the inner layer tends to contain more polyester [41]. These differences show the importance of measuring both sides of such textiles, as significant variations in fiber composition can exist.

3. Materials and Methods

3.1. Textile Samples

The textile samples analyzed consisted of used and discarded post-consumer textiles consisting of both apparel and home textiles. Diversity among the post-consumer textile waste samples was ensured by selecting materials from various sources, including internal collection within the organization and separate collection. The samples represent a range of colors, textile structures such as woven and knitted fabrics, and product categories including t-shirts, pants, etc., as well as varied material compositions, including different polyester/cotton blends and single-fiber polyester and cotton samples. Only the fabric portions of the textile pieces were analyzed, without applications and accessories. Each sample consisted of homogenous, single-layered textile fabric to ensure uniformity in the analysis. Textiles containing only cotton (100% cotton), polyester (0% cotton), or polyester/cotton blends (containing 20–95% cotton) were used, while samples containing any third fiber type were excluded from the study. The cotton content used as the reference cotton content for the experiments was determined through chemical analysis, with label information serving as a plausibility check. The chemical analysis was performed according to ISO 1833-1:2020 [42] and ISO 1833-11:2017 [43]. Cotton was selectively dissolved using 75% sulfuric acid at 50 °C for 1 h. Each sample was digested in duplicate, and the average was used. The method showed a precision of ±1% by mass (95% confidence level) and an expanded uncertainty of ±2% (k = 2), following the EURACEM/CITAT Guide CG 4 [44].
To further stabilize the model in the middle range (between 40 and 50% cotton content), which is typically the most challenging aspect due to the overlapping features of both materials of the blend, virgin polyester/cotton samples from an enzymatic recycling process were used. These 12 samples featured defined cotton concentrations with small, consistent blend increments averaging around 0.5%, enabling more precise representation across this critical range.
To simulate conditions potentially present in post-consumer textiles and to isolate the effects of alkaline treatment, controlled laboratory samples with a constant cotton content of 50% were used. The samples were treated with aqueous sodium hydroxide (NaOH) solutions of varying molarity, ranging from 1 to 7 M (4–28% NaOH w/v), which includes the concentration range for mercerization at 20–26% NaOH (27–33 °Be), under controlled conditions. This allowed for the evaluation of the effect of treatment intensity on spectral behavior and model performance without the influence of blend variations. Alkaline treatment of cotton-rich fabrics is known to induce significant structural changes, including the transformation of cellulose I to cellulose II that takes place above 10% NaOH, which can affect the spectral characteristics and, consequently, the accuracy of material quantification [45]. Although the treatment primarily alters the cellulose component, its effects extend to the overall spectral properties of polyester/cotton blends, helping to clarify its impact on quantification of this blend.
In total, 190 samples were used for this study, among which 79 were used as the training set for model development and 111 were used as the test set for method validation. A larger number of test samples than training samples were used to ensure a robust evaluation of model performance across diverse real-world input data. Additionally, to support the development of methods applicable to textile waste, additional characteristics relevant to each sample were identified to enhance sample diversity and facilitate result interpretation. Table 2 summarizes the number of post-consumer textile samples corresponding to each characteristic for both the training and test set. Reference samples are not included in this overview. In the “Product Category” section, only major categories containing two or more samples are reported. Categories with fewer samples are included in the overall analysis but omitted from the category-specific analysis. Additionally, Table S1 (training samples), Table S2 (test samples), and Table S3 (alkaline treatment samples) provide detailed information on the characteristics and corresponding cotton content for each individual sample included in the study, including both apparel and reference samples.

3.2. Instrumentation and Methodology

Two NIR devices with complementary wavelengths (Figure 9) were used to perform the spectral acquisition: a lab-scale NIR sensor-based sorter (911–1677 nm) and a handheld NIR spectrometer (1596–2396 nm). The NIR sorter (Binder + Co AG, Gleisdorf, Austria) was equipped with an EVK Helios NIR G2-320 (EVK DI Kerschhaggl GmbH, Raaba, Austria) hyperspectral imaging system with a resolution of 312 spatial pixels over 220 spectral bands, resulting in a spectral resolution of ~3.5 nm/pixel and a bandwidth (FWHM) of ~7 nm per channel [46]. Illumination was achieved using a halogen light source in a line-scale configuration. Samples were transported on a conveyor and imaged during free-fall in a sliding type sorter setup, with the NIR sorter using a glass surface placed over a black background during measurement. The integration time was 5 ms per line scan, and white and dark reference calibration was performed before each measurement [47].
The handheld NIR spectrometer used was the microPhazirTM NIR spectrometer by Thermo Fischer Scientific Inc., Waltham, MA, USA. It was used for point measurement covering a 4 mm spot size with a spectral resolution of 8 nm per pixel. The instrument was operated using an internal diffuse reflectance geometry with a built-in light source and detector. Integration time was automatically adjusted, and the instrument did not require additional user-adjustable calibrations as the calibration was managed internally by the device [48]. The samples were measured against a white TiO2-coated reference tile.
Spectral acquisition of the training samples using both instruments was performed to facilitate the training of quantification (regression) models based on their spectral characteristics. The NIR sorter performed spectral acquisition across the entire sample surface, from which a single mean spectrum was calculated and used for further analysis. In contrast, the handheld NIR spectrometer performed point-based measurements. For each sample, spectra were collected from five different positions to ensure coverage of all visually distinct and representative areas. These five spectra were then averaged to generate a single mean spectrum per sample for analysis. To support the repeatability of this approach, the standard deviation across the five spectra was also calculated and used to demonstrate measurement consistency.
Prior to model training, all acquired spectra were pre-processed to reduce instrumental noise and enhance spectral quality. For the NIR sorter, a first derivative followed by spectral smoothing was applied, while the handheld NIR spectrometer data were processed using standard normal variate (SNV) normalization after the first derivative application. The pre-processed spectral data were then used to train the quantification models via PLS regression, and the models were subsequently validated using test samples.
PLS regression was used to develop quantification models for both instruments. Quantification models were trained directly using the associated software tools provided with each instrument (EVK SQALAR 3.4.2017.1 for the NIR sorter and Method Generator 5.4.1.61 software for the handheld NIR spectrometer).
PLS regression is a widely used method for textile quantification. It is a statistical technique focusing on the quantitative relationship between different sets of variables while making predictions for new samples [49]. The goal is to predict a set of dependent variables using a set of independent variables (predictors) by extracting orthogonal factors called known as latent variables (LVs), which possess the strongest predictive power [50]. During model training, the average difference between predicted and actual values was calculated, resulting the in root mean square error of calibration (RMSEC), which estimates the predictive ability of a calibration model [51]. Additionally, the coefficient of determination (R2) indicates the strength of the relationship and was used to assess the quality of the model fit, scaled from 0 to 1. Both are important indicators of the developed model’s quality [52].
Evaluating how well the model applies to the test set, the root mean square error of prediction (RMSEP) and bias were calculated. The RMSEP (Equation (1)) is a measure of how accurately the model predicts unseen data. It quantifies the average deviation between the predicted values y ^ i and the corresponding reference values y i in the test set. The RMSEP is calculated as shown in Equation (1), where n is the number of test samples:
R M S E P =   1 n i = 1 n y i y ^ i 2
A lower RMSEP indicates high predictive accuracy, as it reflects smaller average prediction errors [53].
Bias measures the average signed difference between predicted and reference values and indicates whether the model systematically over- or underestimates in comparison with the reference values. A positive bias suggests underestimation, a negative bias implies overestimation, and a bias of zero indicates no systematic error [54]. Bias is calculated according to Equation (2):
B i a s =   1 n i = 1 1 ( y i y ^ i )
Validation of the methods was conducted separately for the NIR sorter and the handheld NIR spectrometer. For the NIR sorter, validation was performed using the integrated SQALAR software, which calculated the cotton content across the entire measured area and provided an average result. In the case of the handheld NIR spectrometer, validation was carried out directly using the device and the developed method. The cotton content was displayed on the spectrometer screen immediately after each point measurement. To ensure representativeness, five measurements were taken at different points on each sample, and the average cotton content was used as the final result. Additionally, the five individual measurements allowed for the calculation of the standard deviation, which supported the analysis of how various textile characteristics influenced quantification accuracy.

4. Conclusions

This study provides an application-oriented assessment of cotton content quantification in post-consumer textiles using NIR spectroscopy. By evaluating both a lab-scale NIR sorter and a handheld NIR spectrometer, it highlights the current capabilities and limitations of using NIR spectroscopy in textile waste quantification prior to recycling. Importantly, the results indicate that the commonly assumed 10% accuracy level in industrial sorting can be improved. The results showed that accuracy can decrease—depending on the analyzed blend range—by up to 8.5% for the NIR sorter and 3.4% for the handheld NIR spectrometer. When low-cotton textiles (with less than 35% cotton content) were excluded, model performance and stability significantly increased, achieving higher accuracy than typically expected in current industrial applications. Although the threshold was set at 35%, the main finding is the detection of non-linearity, which could potentially begin at a lower cotton content and should be further investigated. This study also demonstrated that certain textile characteristics—such as product type, textile structure, and alkaline treatment—introduce spectral variability that can impact quantification. These findings underline the potential benefits of introducing a preliminary sorting step based on product type prior to material composition analysis. Considering these factors is crucial for developing more reliable and adaptable models, particularly when aiming for refined and precise quantification. By identifying existing limitations and potential sources of errors, this study provides a foundation for improving NIR-based quantification models and supporting textile circularity. The insights presented herein are valuable for stakeholders throughout the textile recycling chain, including researchers, equipment manufacturers, recyclers, and sorting facility operators.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/recycling10040152/s1, Table S1: Training set of samples; Table S2: Test set of samples together with the belonging quantification results; Table S3: Alkaline treatment samples with the belonging quantification results.

Author Contributions

Conceptualization, H.S., G.K., C.B.S., D.L., J.E. and A.T.-A.; Methodology, H.S., G.K., C.B.S., D.L., J.E. and A.T.-A.; Validation, H.S., T.F. and A.T.-A.; Formal analysis, H.S., T.F. and A.T.-A.; Resources, H.S., C.B.S., D.L., J.E. and A.T.-A.; Data curation, H.S., G.K., T.F. and A.T.-A.; Writing—original draft preparation, H.S.; Writing—reviewing and editing, H.S., G.K., C.B.S., D.L. and A.T.-A., Visualization, H.S., T.F. and A.T.-A.; Supervision, A.T.-A. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Austrian Federal Ministry for Economy, Energy, and Tourism; the National Foundation for Research and Development; and the Christian Doppler Research Association in form of CD Laboratory for Design and assessment of an efficient, recycling-based Circular Economy. Additionally, Christian B. Schimper, David Lilek, and Jennie Egan conduct their research at the Josef Ressel Centre “Recovery Strategies of Textiles”, which is funded by the Christian Doppler Research Association on behalf of the Austrian Federal Ministry of Economy, Energy, and Tourism and the National Foundation for Research, Technology, and Development. Jennie Egan was additionally funded by the Gesellschaft für Forschungsförderung Niederösterreich m.b.H. as part of the FTI Dissertations 2023 (FTI23-D-012), and she is further supported by the BOKU University Doc School.

Data Availability Statement

The original contributions presented in this study are included in the article/Supplementary Material. Further inquiries can be directed to the corresponding author(s).

Acknowledgments

This contribution was created within the framework of the CD Laboratory for “Design and Assessment of an Efficient, Recycling-Based Circular Economy”. The financial support from the Austrian Federal Ministry of Economy, Energy, and Tourism; the National Foundation for Research, Technology, and Development; and the Christian Doppler Research Association is greatly acknowledged. Additionally, we greatly acknowledge the financial and non-financial support of our company partners, which are as follows, in alphabetical order: Abfallbehandlung Ahrental GmbH, Altstoff Recycling Austria AG, Linz Service GmbH, OMV Downstream GmbH, and Wien Energie GmbH. During the preparation of this study, the authors used Grammarly, DeepL, and ChatGPT 4o for the purposes of spellchecking, translation, and improving readability. The authors have reviewed and edited the output and take full responsibility for the content of this publication.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
EPRExtended producer responsibility
LVLatent variable
NIRNear-infrared spectroscopy
PLSPartial least squares
RMSECRoot mean square of calibration
RMSEPRoot mean square error of prediction

References

  1. European Environment Agency. Circularity of the EU Textiles Value Chain in Numbers. Available online: https://www.eea.europa.eu/en/analysis/publications/circularity-of-the-eu-textiles-value-chain-in-numbers (accessed on 8 May 2025).
  2. The European Parlament and the Council of the European Union. Directive (EU) 2018/851 of the European Parliament and of the Council of 30 May 2018 Amending Directive 2008/98/EC on Waste. Off. J. Eur. Union 2018, L 150, 109–140. [Google Scholar]
  3. European Commission. EU Strategy for Sustainable and Circular Textiles; European Commission: Brussels, Belgium, 2022.
  4. European Commission. Communication from the Commission to the European Parliament, the Council, the European Economic and Social Committee and the Committee of the Regions: EU Strategy for Sustainable and Circular Textiles; European Commission: Brussels, Belgium, 2022.
  5. ReFashion. Characterisation Study of the Incoming and Outgoing Streams from Sorting Facilities; Refashion: Paris, France, 2023. [Google Scholar]
  6. Lederer, J.; Ipsmiller, W.; Kählig, P.; Bartl, A. Wie Viel Polyester Steckt in Der Altkleidersammlung? Ergebnisse Einer Voruntersuchung Aus WienContent of Polyester in Separately Collected Waste Textiles: A Pre-Investigation from Vienna. Osterr. Wasser Abfallwirtsch. 2024, 76, 411–417. [Google Scholar] [CrossRef]
  7. Leenders, N.; Moerbeek, R.M.; Puijk, M.J.; Bronkhorst, R.J.A.; Bueno Morón, J.; van Klink, G.P.M.; Gruter, G.-J.M. Polycotton Waste Textile Recycling by Sequential Hydrolysis and Glycolysis. Nat. Commun. 2025, 16, 738. [Google Scholar] [CrossRef]
  8. Loo, S.-L.; Yu, E.; Hu, X. Tackling Critical Challenges in Textile Circularity: A Review on Strategies for Recycling Cellulose and Polyester from Blended Fabrics. J. Environ. Chem. Eng. 2023, 11, 110482. [Google Scholar] [CrossRef]
  9. Gritsch, S.M.; Mihalyi, S.; Bartl, A.; Ipsmiller, W.; Jenull-Halver, U.; Putz, R.F.; Quartinello, F.; Guebitz, G.M. Closing the Cycle: Enzymatic Recovery of High Purity Glucose and Polyester from Textile Blends. Resour. Conserv. Recycl. 2023, 188, 106701. [Google Scholar] [CrossRef]
  10. Palme, A.; Peterson, A.; de la Motte, H.; Theliander, H.; Brelid, H. Development of an Efficient Route for Combined Recycling of PET and Cotton from Mixed Fabrics. Text. Cloth. Sustain. 2017, 3, 4. [Google Scholar] [CrossRef]
  11. Jungbluth, M.; Beuermann, S. Separation of Polycotton for Textile Recycling Using the DBU/DMSO/CO2 Switchable Solvent System. ACS Sustain. Chem. Eng. 2025, 13, 4341–4348. [Google Scholar] [CrossRef]
  12. Kahoush, M.; Kadi, N. Towards Sustainable Textile Sector: Fractionation and Separation of Cotton/Polyester Fibers from Blended Textile Waste. Sustain. Mater. Technol. 2022, 34, e00513. [Google Scholar] [CrossRef]
  13. Tischberger-Aldrian, A.; Stipanovic, H.; Kuhn, N.; Bäck, T.; Schwartz, D.; Koinig, G. Automatisierte Textilsortierung—Status quo, Herausforderungen und Perspektiven. Österr. Wasser Abfallwirtsch. 2024, 76, 63–79. [Google Scholar] [CrossRef]
  14. Settle, F.A. Handbook of Instrumental Techniques for Analytical Chemistry; Wiley: Hoboken, NJ, USA, 1997. [Google Scholar]
  15. Riba, J.-R.; Cantero, R.; Canals, T.; Puig, R. Circular Economy of Post-Consumer Textile Waste: Classification through Infrared Spectroscopy. J. Clean. Prod. 2020, 272, 123011. [Google Scholar] [CrossRef]
  16. Becker, A.; Datko, A.; Kroell, N.; Küppers, B.; Greiff, K.; Gries, T. Near-Infrared-Based Sortability of Polyester-Containing Textile Waste. Resour. Conserv. Recycl. 2024, 206, 107577. [Google Scholar] [CrossRef]
  17. Cura, K.; Rintala, N.; Kamppuri, T.; Saarimäki, E.; Heikkilä, P. Textile Recognition and Sorting for Recycling at an Automated Line Using Near Infrared Spectroscopy. Recycling 2021, 6, 11. [Google Scholar] [CrossRef]
  18. Du, W.; Zheng, J.; Li, W.; Liu, Z.; Wang, H.; Han, X. Efficient Recognition and Automatic Sorting Technology of Waste Textiles Based on Online Near Infrared Spectroscopy and Convolutional Neural Network. Resour. Conserv. Recycl. 2022, 180, 106157. [Google Scholar] [CrossRef]
  19. Bonifazi, G.; Gasbarrone, R.; Palmieri, R.; Serranti, S. A Characterization Approach for End-of-Life Textile Recovery Based on Short-Wave Infrared Spectroscopy. Waste Biomass Valorization 2024, 15, 1725–1738. [Google Scholar] [CrossRef]
  20. Faghih, E.; Saki, Z.; Moore, M. A Systematic Literature Review—AI-Enabled Textile Waste Sorting. Sustainability 2025, 17, 4264. [Google Scholar] [CrossRef]
  21. Yao, S.; Li, W.-X.; Zhao, G.-L.; Li, S.-R.; Wang, H.-P.; Zhang, S. NIR Quantitative Model Establishment of Cotton-Polyester Blend Fabrics and Related Problem Exploration. Spectrosc. Spectr. Anal. 2019, 39, 634–639. [Google Scholar] [CrossRef]
  22. Mäkelä, M.; Rissanen, M.; Sixta, H. Machine Vision Estimates the Polyester Content in Recyclable Waste Textiles. Resour. Conserv. Recycl. 2020, 161, 105007. [Google Scholar] [CrossRef]
  23. Paz, M.L.; Sousa, C. Discrimination and Quantification of Cotton and Polyester Textile Samples Using Near-Infrared and Mid-Infrared Spectroscopies. Molecules 2024, 29, 3667. [Google Scholar] [CrossRef]
  24. Wang, Y. Fiber and Textile Waste Utilization. Waste Biomass Valorization 2010, 1, 135–143. [Google Scholar] [CrossRef]
  25. Luchese, C.L.; Engel, J.B.; Tessaro, I.C. A Review on the Mercerization of Natural Fibers: Parameters and Effects. Korean J. Chem. Eng. 2024, 41, 571–587. [Google Scholar] [CrossRef]
  26. Workman, J., Jr.; Weyer, L. Practical Guide and Spectral Atlas for Interpretive Near-Infrared Spectroscopy, 2nd ed.; CRC Press: Boca Raton, FL, USA, 2012; ISBN 978-0-429-11051-1. [Google Scholar]
  27. Siesler, H.; Ozaki, Y.; Kawata, S.; Heise, H. Near-Infrared Spectroscopy: Principles, Instruments, Applications; Wiley: Hoboken, NJ, USA, 2002; ISBN 978-3-527-30149-2. [Google Scholar]
  28. Zhou, W.; Xv, S.; Liu, C.; Zhang, J. Applications of near Infrared Spectroscopy in Cotton Impurity and Fiber Quality Detection: A Review. Appl. Spectrosc. Rev. 2016, 51, 318–332. [Google Scholar] [CrossRef]
  29. Metrohm Polymeranalysen Mittels Nahinfrarotspektroskopie. Available online: https://www.metrohm.com/de_de/applications/ab-application-bulletins/ab-414.html (accessed on 3 June 2025).
  30. Martens, H.; Næs, T. Multivariate Calibration; Wiley: Hoboken, NJ, USA, 1990; ISBN 978-0-471-93047-1. [Google Scholar]
  31. Yan, H.; Siesler, H.W. Identification of Textiles by Handheld near Infrared Spectroscopy: Protecting Customers against Product Counterfeiting. J. Near Infrared Spectrosc. 2018, 26, 311–321. [Google Scholar] [CrossRef]
  32. Stipanovic, H.; Arth, P.; Koinig, G.; Kuhn, N.; Lederer, J.; Blasenbauer, D.; Lipp, A.-M.; Tischberger-Aldrian, A. Influence of Different Measuring Backgrounds on the Classification of Multilayer Polyolefin Films Using a Near-Infrared Handheld Spectrometer. Appl. Spectrosc. 2025, 79, 816–828. [Google Scholar] [CrossRef] [PubMed]
  33. Koinig, G.; Kuhn, N.; Fink, T.; Grath, E.; Tischberger-Aldrian, A. Inline Classification of Polymer Films Using Machine Learning Methods. Waste Manag. 2024, 174, 290–299. [Google Scholar] [CrossRef]
  34. Küppers, B.; Schlögl, S.; Oreski, G.; Pomberger, R.; Vollprecht, D. Influence of Surface Roughness and Surface Moisture of Plastics on Sensor-Based Sorting in the near Infrared Range. Waste Manag. Res. 2019, 37, 0734242X1985543. [Google Scholar] [CrossRef] [PubMed]
  35. Gupta, P.K.; Uniyal, V.; Naithani, S. Polymorphic Transformation of Cellulose I to Cellulose II by Alkali Pretreatment and Urea as an Additive. Carbohydr. Polym. 2013, 94, 843–849. [Google Scholar] [CrossRef] [PubMed]
  36. Textiles Bar. Mercerizing Process in Yarn and Fabric. Textiles Bar 2023. Available online: https://textilesbar.com/mercerizing-process-in-yarn-and-fabric/ (accessed on 3 June 2025).
  37. Wilson, R.H.; Nadeau, K.P.; Jaworski, F.B.; Tromberg, B.J.; Durkin, A.J. Review of Short-Wave Infrared Spectroscopy and Imaging Methods for Biological Tissue Characterization. J. Biomed. Opt. 2015, 20, 030901. [Google Scholar] [CrossRef]
  38. Dickens, B.; Dickens, S.H. Estimation of Concentration and Bonding Environment of Water Dissolved in Common Solvents Using Near Infrared Absorptivity. J. Res. Natl. Inst. Stand. Technol. 1999, 104, 173–183. [Google Scholar] [CrossRef]
  39. Kaur, R.; Chaudhry, M.M.A.; Findlay, C.; Nadimi, M.; Rahman, M.; Paliwal, J. Characterization of Near Infrared-Dye Colored Fabrics Using Hyperspectral Imaging. Appl. Spectrosc. 2024, 78, 951–961. [Google Scholar] [CrossRef]
  40. Huth-Fehre, T.; Feldhoff, R.; Kantimm, T.; Quick, L.; Winter, F.; Cammann, K.; Van Den Broek, W.; Wienke, D.; Melssen, W.; Buydens, L. NIR—Remote Sensing and Artificial Neural Networks for Rapid Identification of Post Consumer Plastics. J. Mol. Struct. 1995, 348, 143–146. [Google Scholar] [CrossRef]
  41. Hook and Eye UK. Fabrics Explained for Fashion Designers. Available online: https://hookandeyeuk.com/en-us/blogs/news/fabrics-explained (accessed on 29 May 2025).
  42. ISO 1833-1:2020; Textiles—Quantitative Chemical Analysis—Part 1: General Principles of Testing. ISO International Organization for Standardization: Geneva, Switzerland, 2020.
  43. ISO 1833-11:2017; Textiles—Quantitative Chemical Analysis—Part 11: Mixtures of Certain Cellulose Fibres with Certain Other Fibres (Method Using Sulfuric Acid). ISO International Organization for Standardization: Geneva, Switzerland, 2017.
  44. EURACHEM. Quantifying Uncertainty in Analytical Measurement, 3rd ed.; EURACHEM: Teddington, UK, 2012. [Google Scholar]
  45. Cao, H.Z.; Yao, Y.; Halada, G.; Jung, H.J.; Kim, T. Impact of NaOH Concentration on Deweaving of Cotton Fabric in Aqueous Solutions. Sustainability 2021, 13, 2015. [Google Scholar] [CrossRef]
  46. Mhaddolkar, N.; Koinig, G.; Vollprecht, D.; Astrup, T.F.; Tischberger-Aldrian, A. Effect of Surface Contamination on Near-Infrared Spectra of Biodegradable Plastics. Polymers 2024, 16, 2343. [Google Scholar] [CrossRef]
  47. Experten Für Industrielle Bildverarbeitung—EVK Kerschhaggl GmbH. Available online: https://www.evk.biz/ (accessed on 9 July 2025).
  48. Beć, K.B.; Grabska, J.; Huck, C.W. Principles and Applications of Miniaturized Near-Infrared (NIR) Spectrometers. Chemistry 2021, 27, 1514–1532. [Google Scholar] [CrossRef]
  49. Wold, S.; Eriksson, L.; Kettaneh, N. PLS in Data Mining and Data Integration. In Handbook of Partial Least Squares: Concepts, Methods and Applications; Esposito Vinzi, V., Chin, W.W., Henseler, J., Wang, H., Eds.; Springer: Berlin/Heidelberg, Germany, 2010; pp. 327–357. ISBN 978-3-540-32827-8. [Google Scholar]
  50. Abdi, H. Partial Least Squares Regression and Projection on Latent Structure Regression (PLS Regression). Wiley Interdiscip. Rev. Comput. Stat. 2010, 2, 97–106. [Google Scholar] [CrossRef]
  51. Luna, A.S.; de Gois, J.S. Chapter Seven—Application of Chemometric Methods Coupled With Vibrational Spectroscopy for the Discrimination of Plant Cultivars and to Predict Physicochemical Properties Using R. In Comprehensive Analytical Chemistry; Lopes, J., Sousa, C., Eds.; Vibrational Spectroscopy for Plant Varieties and Cultivars Characterization; Elsevier: Amsterdam, The Netherlands, 2018; Volume 80, pp. 165–194. [Google Scholar]
  52. Greenwood, M. 6.8: Measuring the Strength of Regressions—R2. Available online: https://stats.libretexts.org/Bookshelves/Advanced_Statistics/Intermediate_Statistics_with_R_(Greenwood)/06%3A_Correlation_and_Simple_Linear_Regression/6.08%3A_Measuring_the_strength_of_regressions_-_R2 (accessed on 4 May 2025).
  53. Faber, N.K.M. Estimating the Uncertainty in Estimates of Root Mean Square Error of Prediction: Application to Determining the Size of an Adequate Test Set in Multivariate Calibration. Chemom. Intell. Lab. Syst. 1999, 49, 79–89. [Google Scholar] [CrossRef]
  54. Pelliccia, D. Bias-Variance Trade-off in PLS Regression; NIRPY Research. 2020. Available online: https://nirpyresearch.com/bias-variance-trade-off-pls-regression/ (accessed on 5 May 2025).
Figure 1. Mean pre-processed spectra shown as the first derivative of absorbance (gradient [ALU/nm]) versus wavelength of various polyester/cotton blends (0–100% cotton), where lighter spectra represent lower cotton content and progressively darker spectra correspond to higher cotton content (a) measured using a lab-scale NIR sorter and (b) measured using a handheld NIR spectrometer.
Figure 1. Mean pre-processed spectra shown as the first derivative of absorbance (gradient [ALU/nm]) versus wavelength of various polyester/cotton blends (0–100% cotton), where lighter spectra represent lower cotton content and progressively darker spectra correspond to higher cotton content (a) measured using a lab-scale NIR sorter and (b) measured using a handheld NIR spectrometer.
Recycling 10 00152 g001
Figure 2. The results of predicted vs. reference cotton content in post-consumer polyester/cotton textiles, shown relative to the line of identity using a lab-scale NIR sorter.
Figure 2. The results of predicted vs. reference cotton content in post-consumer polyester/cotton textiles, shown relative to the line of identity using a lab-scale NIR sorter.
Recycling 10 00152 g002
Figure 3. The results of predicted vs. reference cotton content in post-consumer polyester/cotton textiles, shown relative to the line of identity using a lab-scale handheld NIR spectrometer.
Figure 3. The results of predicted vs. reference cotton content in post-consumer polyester/cotton textiles, shown relative to the line of identity using a lab-scale handheld NIR spectrometer.
Recycling 10 00152 g003
Figure 4. The results of predicted vs. reference cotton values for the model focusing on the 0–35% cotton range, shown relative to the line of identity: (a) lab-scale NIR sorter and (b) handheld NIR spectrometer.
Figure 4. The results of predicted vs. reference cotton values for the model focusing on the 0–35% cotton range, shown relative to the line of identity: (a) lab-scale NIR sorter and (b) handheld NIR spectrometer.
Recycling 10 00152 g004
Figure 5. Influence of textile characteristics on quantification accuracy: absolute errors (%) for samples grouped by characteristics as measured using both the NIR sorter and handheld NIR spectrometer, including the standard deviation (%) of five measurements from the handheld NIR spectrometer.
Figure 5. Influence of textile characteristics on quantification accuracy: absolute errors (%) for samples grouped by characteristics as measured using both the NIR sorter and handheld NIR spectrometer, including the standard deviation (%) of five measurements from the handheld NIR spectrometer.
Recycling 10 00152 g005
Figure 6. (a) Absolute and (b) relative errors across samples treated with varying molarities of alkaline treatment (NaOH).
Figure 6. (a) Absolute and (b) relative errors across samples treated with varying molarities of alkaline treatment (NaOH).
Recycling 10 00152 g006aRecycling 10 00152 g006b
Figure 7. Mean pre-processed spectra shown as the first derivative of absorbance (gradient [ALU/nm]) versus wavelength of spectral changes for samples treated with varying molarities of alkaline treatment (NaOH) (a) measured with a lab-scale NIR sorter and (b) measured with a handheld NIR spectrometer.
Figure 7. Mean pre-processed spectra shown as the first derivative of absorbance (gradient [ALU/nm]) versus wavelength of spectral changes for samples treated with varying molarities of alkaline treatment (NaOH) (a) measured with a lab-scale NIR sorter and (b) measured with a handheld NIR spectrometer.
Recycling 10 00152 g007
Figure 8. Visualization of challenging samples delivering inconsistent results: (a) visually heterogenous samples, (b) light grey-colored textiles, and (c) sweatshirt and sweatpant materials.
Figure 8. Visualization of challenging samples delivering inconsistent results: (a) visually heterogenous samples, (b) light grey-colored textiles, and (c) sweatshirt and sweatpant materials.
Recycling 10 00152 g008
Figure 9. Instruments used for the performed measurements: (a) lab-scale NIR sorter and (b) handheld NIR spectrometer.
Figure 9. Instruments used for the performed measurements: (a) lab-scale NIR sorter and (b) handheld NIR spectrometer.
Recycling 10 00152 g009
Table 1. Overview of RMSEP and the average bias values across cotton content ranges for both instruments.
Table 1. Overview of RMSEP and the average bias values across cotton content ranges for both instruments.
Cotton Content (%)Bias (%)RMSEP (%)
SorterHandheldSorterHandheld
0–349.313.89.614.3
35–49−2.5−1.89.83.9
50–595.71.57.54.1
60–79−2.5−0.78.54.9
80–993.82.19.43.4
100−3.2−1.53.62.2
Table 2. Overview of post-consumer textile samples and their sample characteristics included in the study and their corresponding sample counts.
Table 2. Overview of post-consumer textile samples and their sample characteristics included in the study and their corresponding sample counts.
Sample CharacteristicsTraining SetTest Set
Material composition0% cotton930
20–80% cotton4134
100% cotton2947
Surface designUnicolor6183
Patterned1828
Textile structureKnitted3572
Woven4439
Application typeApparel3399
Home textiles3412
Product categoryT-shirt1029
Sport apparel212
Sweatshirts/sweatpants413
Shirt and blouse816
Scarf25
Jacket35
Pants24
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Stipanovic, H.; Koinig, G.; Fink, T.; Schimper, C.B.; Lilek, D.; Egan, J.; Tischberger-Aldrian, A. Quantifying Cotton Content in Post-Consumer Polyester/Cotton Blend Textiles via NIR Spectroscopy: Current Attainable Outcomes and Challenges in Practice. Recycling 2025, 10, 152. https://doi.org/10.3390/recycling10040152

AMA Style

Stipanovic H, Koinig G, Fink T, Schimper CB, Lilek D, Egan J, Tischberger-Aldrian A. Quantifying Cotton Content in Post-Consumer Polyester/Cotton Blend Textiles via NIR Spectroscopy: Current Attainable Outcomes and Challenges in Practice. Recycling. 2025; 10(4):152. https://doi.org/10.3390/recycling10040152

Chicago/Turabian Style

Stipanovic, Hana, Gerald Koinig, Thomas Fink, Christian B. Schimper, David Lilek, Jeannie Egan, and Alexia Tischberger-Aldrian. 2025. "Quantifying Cotton Content in Post-Consumer Polyester/Cotton Blend Textiles via NIR Spectroscopy: Current Attainable Outcomes and Challenges in Practice" Recycling 10, no. 4: 152. https://doi.org/10.3390/recycling10040152

APA Style

Stipanovic, H., Koinig, G., Fink, T., Schimper, C. B., Lilek, D., Egan, J., & Tischberger-Aldrian, A. (2025). Quantifying Cotton Content in Post-Consumer Polyester/Cotton Blend Textiles via NIR Spectroscopy: Current Attainable Outcomes and Challenges in Practice. Recycling, 10(4), 152. https://doi.org/10.3390/recycling10040152

Article Metrics

Back to TopTop