Use of Thermal Imaging to Assess Water Status in Citrus Plants in Greenhouses

by
Gustavo Haddad Souza Vieira
1 and
Rhuanito Soranz Ferrarezi
2,3,*
1
Federal Institute of Espírito Santo, Campus Santa Teresa, Rod. ES 080 km 93, São João de Petrópolis, Santa Teresa 29600-000, ES, Brazil
2
Indian River Research and Education Center, University of Florida, 2199 S Rock Road, Fort Pierce, FL 34945, USA
3
Department of Horticulture, University of Georgia, 1111 Plant Sciences Bldg, Athens, GA 30602, USA
*
Author to whom correspondence should be addressed.
Horticulturae 2021, 7(8), 249; https://doi.org/10.3390/horticulturae7080249
Submission received: 16 June 2021 / Revised: 12 August 2021 / Accepted: 13 August 2021 / Published: 16 August 2021
(This article belongs to the Special Issue Irrigation and Water Management in Horticulture)

Abstract

The direct examination of plant canopy temperature can assist in optimizing citrus irrigation management in greenhouses. This study aimed to develop a method to measure canopy temperature using thermal imaging in one-year-old citrus plants in a greenhouse to identify plants with water stress and verify its potential to be used as a tool to assess citrus water status. The experiment was conducted for 48 days (27 November 2019 to 13 January 2020). We evaluated the influence of five levels of irrigation on two citrus species (‘Red Ruby’ grapefruit (Citrus paradisi) and ‘Valencia’ sweet orange (Citrus sinensis (L.) Osbeck)). Images were taken using a portable thermal camera and analyzed using open-source software. We determined canopy temperature, leaf photosynthesis and transpiration, and plant biomass. The results indicated a positive relationship between the amount of water applied and the temperature response of plants exposed to different water levels. Grapefruit and sweet orange plants that received less water and were submitted to water restrictions showed higher canopy temperatures than the air (up to 6 °C). The thermal images easily identified water-stressed plants. Our proof-of-concept study allowed quickly obtaining the canopy temperature using readily available equipment and can be used as a tool to assess citrus water status in one-year-old citrus plants in greenhouses and perhaps in commercial operations with mature trees in the field after specific experimentation. This technique, coupled with an automated system, can be used for irrigation scheduling. Thus, setting up a limit temperature is necessary to start the irrigation system and set the irrigation time based on the soil water content. To use this process on a large scale, it is necessary to apply an automation routine to process the thermal images in real time and remove the weeds from the background to determine the canopy temperature.
Keywords: canopy temperature; irrigation; physiology; thermal camera; transpiration canopy temperature; irrigation; physiology; thermal camera; transpiration

Share and Cite

MDPI and ACS Style

Vieira, G.H.S.; Ferrarezi, R.S. Use of Thermal Imaging to Assess Water Status in Citrus Plants in Greenhouses. Horticulturae 2021, 7, 249. https://doi.org/10.3390/horticulturae7080249

AMA Style

Vieira GHS, Ferrarezi RS. Use of Thermal Imaging to Assess Water Status in Citrus Plants in Greenhouses. Horticulturae. 2021; 7(8):249. https://doi.org/10.3390/horticulturae7080249

Chicago/Turabian Style

Vieira, Gustavo Haddad Souza, and Rhuanito Soranz Ferrarezi. 2021. "Use of Thermal Imaging to Assess Water Status in Citrus Plants in Greenhouses" Horticulturae 7, no. 8: 249. https://doi.org/10.3390/horticulturae7080249

APA Style

Vieira, G. H. S., & Ferrarezi, R. S. (2021). Use of Thermal Imaging to Assess Water Status in Citrus Plants in Greenhouses. Horticulturae, 7(8), 249. https://doi.org/10.3390/horticulturae7080249

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop