Next Article in Journal
Visual Cortical Processing in Children with Early Bilateral Cochlear Implants: A VEP Analysis
Previous Article in Journal
Exploring the Interactions Between Epidural Analgesia, Extubation and Reintubation Outcomes in Infants in Neonatal Care Units: A Retrospective Cohort Study
Previous Article in Special Issue
Airway Epithelial Cultures of Children with Esophageal Atresia as a Model to Study Respiratory Tract Disorders
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

The Feasibility and Validity of Home Spirometry for People with Cystic Fibrosis: Is It Comparable to Spirometry in the Clinic?

by
Athina Sopiadou
,
Maria Gioulvanidou
,
Christos Kogias
,
Elissavet-Anna Chrysochoou
,
Ioustini Kalaitzopoulou
and
Elpis Hatziagorou
*
Pediatric Pulmonology and CF Unit, Hippokration Hospital of Thessaloniki, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
*
Author to whom correspondence should be addressed.
Children 2025, 12(3), 277; https://doi.org/10.3390/children12030277
Submission received: 25 January 2025 / Revised: 17 February 2025 / Accepted: 23 February 2025 / Published: 25 February 2025
(This article belongs to the Special Issue Lung Diseases in Children: From Rarer to Commonest: 2nd Edition)

Abstract

:
Background/Objectives: Home spirometry allows people with cystic fibrosis (CF) to monitor their lung function from home. However, there are concerns about its feasibility and validity compared to traditional clinic spirometry. The aim of this study was to evaluate the feasibility and validity of telehealth spirometry for patients with CF living in a regional setting. Methods: This retrospective study included forty-eight people with cystic fibrosis (pwCF) aged 6–33 years. Participants performed home spirometry using a portable flow sensor spirometer over a one-year period, without supervision. Spirometry readings from portable spirometers were compared with the nearest in-clinic spirometry using the intra-correlation coefficient (ICC) and Bland–Altman plots. Data were collected over a period of one year, with regular intervals of measurements. Results: In 427 of the 877 (48.6%) attempted sessions, successful spirometry at home was recorded. Although we showed good reliability between at-home and in-clinic measurements using the Bland–Altman plots and intraclass correlation co-efficient (ICC) (values ranged from 0.76 to 0.88), analysis of the 117 pairs of at-home and in-clinic spirometries showed that mean differences of forced expiratory volume in the 1st sec (FEV1) and forced vital capacity (FVC) obtained at home (both in liter and z-score) had, on average, lower values than the corresponding values at the clinic. Conclusions: Home-based telehealth spirometry is feasible among pwCF and provides advantages, especially for those from remote or secluded areas. However, lower values in FVC and FEV1 obtained through home spirometry should not be used interchangeably with clinic values.

1. Introduction

Cystic fibrosis (CF) is a severe chronic respiratory disease that requires close monitoring of patients to assess their respiratory function [1]. The most common and accessible way to evaluate the lung function of pwCF is spirometry [2]. During the COVID-19 pandemic, the standard of care protocol for pwCF was disrupted, and many CF centers adopted telemedicine to monitor patients [3].
Telemedicine in CF was introduced by Finkelstein et al. in 1986, with the introduction of a program for monitoring patients at a distance by having a daily journal of symptoms to achieve better survival [4]. Since then, telemedicine has evolved its methods and achieved greater adoption through smartphone software, especially during the COVID-19 quarantine period [5].
Telespirometry is a telemedicine tool used to remotely monitor lung function in patients with chronic respiratory disease. The procedure can be conducted under the supervision of a technician or not, and the results can be transmitted synchronously or asynchronously to the examiner [6]. Despite the promise of home spirometry, questions remain regarding its feasibility and validity compared to traditional clinic spirometry. Are the measurements obtained from home spirometry comparable to those obtained in a clinical setting? Can home spirometry be a reliable tool for monitoring lung function and guiding treatment decisions in CF patients?
Most of the published studies in telespirometry concerning adults with asthma and COPD examine the validity of the measurements taken by portable spirometers and their agreement with the spirometry measurements obtained in a clinic or the office [7,8]. Many CF centers have shared their experience of home spirometry, mainly conducting feasibility studies for adults or teenagers, with only a few of them studying spirometry at home without supervision, as in real-life conditions [3,9,10].
This article explores the feasibility and validity of home spirometry for individuals with cystic fibrosis and examines whether it can be used interchangeably with clinic spirometry.

2. Methods

2.1. Study Design and Participants

This is a retrospective feasibility study exploring home spirometry in cystic fibrosis patients. We evaluated spirometric data from 48 pwCF older than six years of age who attended our CF clinic over one year during the COVID-19 pandemic (from January 2021 to January 2022). Patients aged 6 to 33 years old were asked to perform spirometry at home twice monthly during stable periods, using a hand-held portable spirometer (MIR SpiroBank smart), and send those measurements to the clinic by email. PwCF and their caregivers (in the case of children < 12 years) were educated on using the portable spirometer over clinic visits and Internet sessions. Moreover, patients performed clinic spirometry with the respiratory laboratory spirometer (Vitalograph 2120) on the standard of care hospital visits, quarterly or sooner if they had symptoms of pulmonary exacerbation. To assess the potential benefits of home spirometry for our patients living in a regional setting, we recorded the distance and the time required to travel to the cystic fibrosis center.
The inclusion criteria of the study population were as follows: (1) Diagnosis of cystic fibrosis confirmed with a sweat test and genetic testing; (2) the ability to perform technically acceptable spirometry in the CF clinic; and (3) the families should have access to the Internet.
The reporting of this study conforms to the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement [11].
The study was approved by the ethics committee, and written informed consent was obtained from all patients in the case of adults or their parents for participants under 18 years of age.

2.2. Spirometry

Spirometry data obtained from the measurements were FVC, FEV1, ppFEV1, FEV1/FVC, FEF25-75, back-extrapolated volume (BEV), the repeatability of FEV1 and FVC, and the grade of the home spirometry according to ATS/ERS 2019 standards. We evaluated pre-bronchodilator spirometries. Successful spirometry was defined as grade A and B.
Clinic spirometry was conducted under the supervision of an experienced nurse in the upright position with no nose clip or bronchodilation, according to ATS/ERS criteria [12]. The analyzed parameters were FVC, FEV1, ppFEV1, FVC/FEV1, and FEF25-75.
Hand-held portable spirometer MIR SpiroBank smart is a flow sensor with a bidirectional turbine spirometer. It is compatible with the renewed criteria for spirometry of the ATS/ERS 2019 and does not require calibration. The range of flow measurements is ±16 L/s with an accuracy of flow of ±5.0%, or 0.20 L/s, and an accuracy of volume of ±2.5%, or 0.05 L. The laboratory spirometer used is a standard electronic spirometer, a Vitalograph 2120, Lab Manager systemV5 2.0 (Viasys Healthcare, Ennis, Ireland).
Comparison of At-Home and In-Clinic Measurements
The at-home and in-clinic comparison measurements were obtained from 45 patients, with a maximum time difference of 30 days. Two patients were excluded because of continuous unsuccessful spirometries at home; three exceeded the 30-day time limit. From paired data from 117 spirometries, we examined the mean differences in FVC, FEV1, and FEF25-75 as absolute values and their corresponding z-score (according to 2012 Global Lung Initiative equations, GLI 2012, http://www.lungfunction.org (accessed on 1 March 2022)) [13]. The degree of agreement between the two methods of measuring pulmonary function (spirometry at home and in the clinic) was depicted using the intra-correlation coefficient (ICC) and Bland–Altman plots. A second analysis was conducted for paired measurements with a maximum time difference of 15 days to minimize the possible bias of variability between the measurements due to the significant time difference.

2.3. Statistical Analysis

Descriptive statistics were calculated using the mean and standard deviation for continuous variables and frequencies (N) and percentages (%) for categorical variables. No formal sample size calculations were performed; this is a feasibility study. The intra-class correlation coefficient (ICC) and 95% CI for each spirometry parameter were calculated to assess the agreement between measurements taken at home and the clinic. An ICC value above 0.75 was considered good, and a value above 0.90 was considered excellent. Moreover, the Bland–Altman method was used along with the 95% limits of agreement [14]. Limits of agreement quantify dispersion among paired differences, and we defined a range smaller than 150 mL as the cut-off for the clinical acceptance of spirometry according to the ATS/ERS criterion of acceptable repeatability [15,16].
Generalized estimating equations (GEEs) were used to evaluate the association between spirometry evaluation and the different patients’ characteristics: age (6–11 y.o, 12–17 y.o, or >18 y.o), gender (male or female), pseudomonas (none, intermittent, or chronic), disease severity (mild: ppFEV1 > 80%, moderate: ppFEV1 60–80%, or severe: ppFEV1 < 60%) and mutations (homozygous ΔF508, heterozygous ΔF508, or none). The analysis was conducted with IBM SPSS Statistics 28 and a level of statistical significance of 5%.

3. Results

Over the study period, 48 pwCF of 6 to 33 years of age, with a mean ppFEV1 of 84.98 (StDev 20.94) and a mean distance from the CF Center of 103.99 km (saving 1.5 h per clinic visit), performed 877 home spirometries. The baseline characteristics of the patients are shown in Table 1. According to the ATS/ERS 2019 criteria for acceptability and repeatability, successful assessments were recorded in 48.68% (427/877) of them (Table S1). Generalized estimating equation (GEE) analysis of the association between successful spirometry and the different patients’ characteristics showed that only age was statistically significant.
In the comparative analysis of 117 paired measurements (home vs. clinic spirometries), it was found that FVC and FEV1, both in absolute and z-score values, from spirometries performed at home showed lower values on average compared to the corresponding values at the clinic, with a mean difference of −0.37 L (LoA −1.66, +0.96) and −0.22 L (LoA −1.04, +0.60) for FVC and FEV1. The mean differences of FEV1 and FVC in z-score were −0.58 (LoA −2.83, +1.59) and −0.76 (LoA −3.89, +2.27), with the z-score being lower for home assessments. For the z-score of the parameters FEF25-75 (L/s) and FEF25-75, lower values were observed but were not statically significant, as shown in Table 2.
Intraclass correlation coefficient (ICC) values ranged from 0.76 to 0.88, indicating good reliability and suggesting that the spirometry parameters were measured similarly at home and the clinic (Table S2). However, for the parameter FVC z-score, the ICC value was 0.57, indicating moderate reliability. In the Bland–Altman plots for each one of the spirometry parameters, there is a small amount of negative bias (Figure 1). However, most differences lie between the limits of agreement, indicating good agreement between spirometry values taken at home and those taken in the clinic.
When a second comparative analysis was conducted for 82 paired measurements from 36 patients with a narrower period between the assessments (maximum 15 days); the results were similar for mean differences, ICC, and limits of agreement (Figure S1).

4. Discussion

The study’s primary objective was to examine the feasibility and validity of home spirometry among pwCF by analyzing unsupervised home spirometries performed by 48 patients. We proved that there was good agreement between at-home and in-clinic measurements, using ICC and Bland–Altman plots, independently of the time interval between spirometries. Despite this, FEV1 and FVC differ significantly between the two spirometers, with wide limits of agreement, making their interchangeable use unacceptable.
Of the 877 measurements, 427 (48.68%) were successful spirometries (graded A or B according to the ATS/ERS 2019 revised criteria). It is important to note that despite pwCF being familiar with spirometry and most patients being over 12 years of age, the success rate was still lower than expected. The success rate of home spirometry was lower than expected, which can be attributed to the fact that the spirometry was performed without the supervision of experienced clinic personnel. For example, Kruizinga et al. conducted a prospective study of 90 patients with asthma and CF and found that only about 45% of spirometries conducted at home met ATS/ERS standards [17]. Consistent with our findings, Davis et al. assessed the performance of the Mir Spirobank spirometer in pwCF for unsupervised home spirometry, reporting that 63% of measurements were within acceptable grades (A–C) [18].
Furthermore, the absence of error feedback during the procedure may have contributed to the lower-than-expected at-home spirometry results. Supervised spirometry is crucial for successful spirometry [19]. However, other factors can contribute to lower-quality home spirometry measurements, such as spirometer and diurnal variability differences. Degryse et al., in a validation study of the Mir Spirobank spirometer in a primary care setting, showed that differences in measurements compared to a standard one reach up to 5% [20]. Another comparison study of the MIR spirometer in school-aged children with a history of bronchopulmonary dysplasia depicted lower values in FVC and FEV1 when using the portable spirometer with an acceptable mean bias but with wide limits of agreement [21].
Logie et al. showed that 22 individuals with cystic fibrosis (ages 7–17) achieved a 93% success rate in home spirometry during online appointments with a technician’s guidance [22]. Conversely, Loeb et al. reported a lower success rate of 74% in younger patients (ages 4–17) using a similar protocol [23]. In another study by Alliance involving 937 GPs and 20,757 spirometries, 70% of online assessments met the criteria for excellent and partial cooperation. However, results across telespirometry studies vary, underscoring the importance of supervision during spirometry [24]. Fettes et al. showed that supervised spirometry yielded grade-A results in 89% of measurements compared to 74% in the unsupervised group (p < 0.001) [25]. On the contrary, Berlinski et al. found clinically significant differences in FEV1 between coached and uncoached home spirometry compared to clinic measurements, with home spirometry yielding lower values. This highlights the importance of understanding these differences before launching an at-home spirometry program [26].
Comparative analysis of the 117 paired measurements of at-home and in-clinic spirometry proved the good agreement between the two methods for FVC and FEV1 with ICC values of 0.80 and 0.88, respectively (p-value < 0.001). This relation has been proved in other studies in CF and asthma. The Bland–Altman plots also depicted the good agreement between the two spirometers and showed, as in other studies, the validity of the measurements from home spirometry [22,23,24].
However, the mean difference between FVC and FEV1 was −0.37 L and −0.22 L (p < 0.001) for paired measurements, indicating the underestimation of the spirometric values in home spirometry and not reaching the ATS/ERS criterion for acceptable repeatability (<150 mL) that most studies define as clinically meaningful [25,27,28]. Paynter et al. studied the mean difference in ppFEV1 between a portable spirometer and the spirometer in the clinic in pwCF in cross-sectional and longitudinal aspects. They showed a mean difference of −2.1% in at-home spirometries, expanding to −2.43%, as the period between the two measurements was wider (maximum 28 days) [29]. In accordance with our results, the CLIMB-CF study showed that 76.2% of pwCF recorded lower results in unsupervised home spirometries, with wide limits of agreement in the Bland–Altman plots for FEV1, concluding that at-home and in-clinic spirometry should not be used interchangeably [30]. These results are consistent with those of John Oppenheimer et al. in asthma patients, who proved poor agreement between at-home and in-clinic spirometric measures based on the 95% limits of agreement [31]. In a meta-analysis, Anad et al. demonstrated that, across respiratory conditions, unsupervised home spirometry tends to yield lower values compared to supervised clinic measurements, with wide limits of agreement [32].
Our study also examined the differences in FEV1 and FVC z-score values considering the latest ERS/ATS statement with a mean difference of −0.58 and −0.76, with lower values for at-home spirometry, and clinically significant difference that overrode the 0.5 z-score difference. Unfortunately, few pediatric studies compare portable and standard spirometers and use z-score values [33,34].

Limitations of the Study

One of the study’s limitations is the population size and the number of spirometries. In our study, we did not employ any reinforcement methods to increase the success rate of the measurements, such as reminders (messages or telephone calls) to increase participation and the total number of assessments at home [35]. The eICE study highlighted that the participation of pwCF in telemedicine studies can be an issue, particularly when frequent measurements (daily or twice per week) are required [36]. To minimize the influence of daily variability typically observed in FEV1, a standard hour should have been defined for conducting home spirometry [37].

5. Conclusions

In conclusion, this study examines the feasibility of telespirometry without supervision in an asynchronous way for pwCF. The results suggest that telespirometry can benefit patients living in remote areas, in addition to the standard protocol for monitoring CF patients, by reducing the need for in-clinic visits, lessening travel burden, and lowering infection risk while promoting patient engagement and treatment adherence. In addition, frequent home measurements can be used to track trends over time and to enable early detection of pulmonary decline and timely intervention [37].
Despite the possible benefits of at-home spirometry, the underestimation of FEV1 and FVC values in portable spirometers demonstrates that for now, interchangeable use between spirometers is unacceptable and further research is needed.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/children12030277/s1, Table S1: Grading of home spirometries according to the ATS/ERS 2019 criteria for acceptability and repeatability. Table S2: Intraclass correlation coefficient for the reliability between spirometry parameters of home and clinic measurements. Figure S1: Bland–Altman plot of differences in FVC (lt and z-score), FEV1 (lt/s and z-score), and FEF25-75 (lt/s and z-score) between at-home and in-clinic measurements (the red line represents the mean difference and green lines represent the 95% limits of agreement) in 82 paired measurements from 36 patients with a narrower period between the assessments (maximum 15 days).

Author Contributions

Conceptualization, A.S. and E.H.; data curation, A.S., M.G., C.K., E.-A.C., I.K. and E.H.; investigation, A.S., M.G., C.K., E.-A.C., I.K. and E.H.; methodology, A.S.; supervision, E.H.; validation, A.S. and E.H.; visualization, A.S. and E.H.; writing—original draft, A.S., M.G., C.K., E.-A.C., I.K. and E.H.; writing—review and editing, A.S. and E.H. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

This study was conducted in accordance with the Declaration of Helsinki and approved by the Institutional Review Board of Hippokration Hospital of Thessaloniki (approval no. IRB File No.: 3/2-5-2018 52876/2-11-2022), 24 January 2023.

Informed Consent Statement

Written informed consent was obtained from all patients in the case of adults or their parents for participants under 18 years of age.

Data Availability Statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.

Acknowledgments

We would like to thank the pwCF and their families for participating in this study. We would also like to thank our CF nurses, Katerina Baka and Zoe Christakoudi, for supervising spirometry in the CF clinic and participating in the educational process of telehealth spirometry.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
CFCystic fibrosis
pwCFPeople with cystic fibrosis
ATS/ERSAmerican Thoracic Society/European Respiratory Society
ICCIntra-correlation coefficient
FEV1Forced expiratory volume in the first sec
FVCForced vital capacity
COPDChronic obstructive pulmonary disease
STROBEStrengthening the Reporting of Observational Studies in Epidemiology
ppFEV1Percent predicted forced expiratory volume in one second
FEF25-75Forced expiratory flow at 25% and 75% of pulmonary volume
BEVBack extrapolated volume
GLIGlobal Lung Initiative equations
GEEGeneralized estimating equations
LoALimits of agreement

References

  1. Shteinberg, M.; Haq, I.J.; Polineni, D.; Davies, J.C. Cystic fibrosis. Lancet 2021, 397, 2195–2211. [Google Scholar] [CrossRef] [PubMed]
  2. Castellani, C.; Duff, A.J.A.; Bell, S.C.; Heijerman, H.G.M.; Munck, A.; Ratjen, F.; Sermet-Gaudelus, I.; Southern, K.W.; Barben, J.; Flume, P.A.; et al. ECFS best practice guidelines: The 2018 revision. J. Cyst. Fibrosis. 2018, 17, 153–178. [Google Scholar] [CrossRef] [PubMed]
  3. Richardson, C.H.; Orr, N.J.; Ollosson, S.L.; Irving, S.J.; Balfour-Lynn, I.M.; Carr, S.B. Initiating home spirometry for children during theCOVID-19 pandemic—A practical guide. Paediatr. Respir. Rev. 2021, 42, 43–48. [Google Scholar] [PubMed]
  4. Finkelstein, S.M.; Budd, J.R.; Warwick, W.J.; Kujawa, S.J.; Wielinski, C.L.; Ewing, L.B. Feasibility and compliance studies of a home measurement monitoring program for cystic fibrosis. J. Chronic Dis. 1986, 39, 195–205. [Google Scholar] [CrossRef] [PubMed]
  5. Dixon, E.; Dick, K.; Ollosson, S.; Jones, D.; Mattock, H.; Bentley, S.; Saunders, C.; Matthews, J.; Dobra, B.; King, J.; et al. Telemedicine and cystic fibrosis: Do we still need face-to face clinics? Paediatr. Respir. Rev. 2021, 42, 23–28. [Google Scholar] [CrossRef] [PubMed]
  6. Morais-Almeida, M.; Barbosa, M.T.; Sousa, C.S.; Almeida, I.; Pimenta, L.; Aguiar, R. Spirometry Outside the Hospital. Arch. Bronconeumol. 2021, 57, 236. [Google Scholar] [CrossRef] [PubMed]
  7. Masa, J.F.; Gonzalez, M.T.; Pereira, R.; Mota, M.; Riesco, J.A.; Corral, J.; Zamorano, J.; Rubio, M.; Teran, J.; Farré, R. Validity of spirometry performed online. Eur. Respir. J. 2011, 37, 911–918. [Google Scholar] [CrossRef]
  8. Bruderman, I.; Abboud, S. Telespirometry: Novel System for Home Monitoring of Asthmatic Patients. Telemed. J. 1997, 3, 127–133. [Google Scholar] [CrossRef] [PubMed]
  9. Shanthikumar, S.; Ruseckaite, R.; Corda, J.; Mulrennan, S.; Ranganathan, S.; Douglas, T. Telehealth use in Australian cystic fibrosis centers: Clinician experiences. Pediatr. Pulmonol. 2023, 58, 2906–2915. [Google Scholar] [CrossRef]
  10. Schaffer, S.; Strang, A.; Shenoy, A.; Selhorst, D.; Chidekel, A. Education and implementation of home spirometry in an adolescent cystic fibrosis population. Respir. Med. Res. 2023, 84, 101040. [Google Scholar] [CrossRef] [PubMed]
  11. Elm E von Altman, D.G.; Egger, M.; Pocock, S.J.; Gøtzsche, P.C.; Vandenbroucke, J.P. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: Guidelines for reporting observational studies. J. Clin. Epidemiol. 2008, 61, 344–349. [Google Scholar] [CrossRef] [PubMed]
  12. Miller, M.R.; Hankinson, J.; Brusasco, V.; Burgos, F.; Casaburi, R.; Coates, A.; Crapo, R.; Enright, P.; van der Grinten, C.P.; Gustafsson, P.; et al. Standardisation of spirometry. Eur. Respir. J. 2005, 26, 319–338. [Google Scholar] [CrossRef] [PubMed]
  13. Cooper, B.G.; Stocks, J.; Hall, G.L.; Culver, B.; Steenbruggen, I.; Carter, K.W.; Thompson, B.R.; Graham, B.L.; Miller, M.R.; Ruppel, G.; et al. The Global Lung Function Initiative (GLI) Network: Bringing the world’s respiratory reference values together. Breathe 2017, 13, e56–e64. [Google Scholar] [CrossRef]
  14. Bland, J.M.; Altman, D. Statistical Methods for Assessing Agreement Between Two Methods of Clinical Measurement. Lancet 1986, 327, 307–310. [Google Scholar] [CrossRef]
  15. Giavarina, D. Understanding Bland Altman analysis. Biochem. Med. 2015, 25, 141–151. [Google Scholar] [CrossRef] [PubMed]
  16. Loeb, J.S.; Blower, W.C.; Feldstein, J.F.; Koch, B.A.; Munlin, A.L.; Hardie, W.D. Acceptability and repeatability of spirometry in children using updated ATS/ERS criteria. Pediatr. Pulmonol. 2008, 43, 1020–1024. [Google Scholar] [CrossRef]
  17. Kruizinga, M.D.; Essers, E.; Stuurman, F.E.; Yavuz, Y.; de Kam, M.L.; Zhuparris, A.; Janssens, H.M.; Groothuis, I.; Sprij, A.J.; Nuijsink, M.; et al. Clinical validation of digital biomarkers for pediatric patients with asthma and cystic fibrosis: Potential for clinical trials and clinical care. Eur. Respir. J. 2021, 59, 2100208. [Google Scholar]
  18. Davis, J.; Ryan, M.; Marchetti, P.; Dahlberg, S.E.; Greenberg, J.; Bacon, C.; Kaur, R.; Scalia, S.; Sawicki, G.S. Real-world feasibility of short-term, unsupervised home spirometry in CF. Pediatr. Pulmonol. 2022, 57, 3129–3135. [Google Scholar] [CrossRef]
  19. Gerzon, F.L.G.R.; Jöbsis, Q.; Bannier, M.A.G.E.; Winkens, B.; Dompeling, E. Discrepancy between Lung Function Measurements at Home and in the Hospital in Children with Asthma and CF. J. Clin. Med. 2020, 9, 1617. [Google Scholar] [CrossRef]
  20. Degryse, J.; Buffels, J.; Van Dijck, Y.; Decramer, M.; Nemery, B. Accuracy of Office Spirometry Performed by Trained Primary-Care Physicians Using the MIR Spirobank Hand-Held Spirometer. Respiration 2012, 83, 543–552. [Google Scholar] [CrossRef]
  21. Mukharesh, L.; Ryan, M.; Hayden, L.P.; Dahlberg, S.E.; Gaffin, J.M. Comparison of Pneumotachometer and Portable Digital Turbine Spirometry for Field-Based Assessment: An Air Quality, Environment, and Respiratory Outcomes in Bronchopulmonary Dysplasia Study. Pediatr. Allergy Immunol. Pulmonol. 2023, 36, 115–118. [Google Scholar] [CrossRef] [PubMed]
  22. Shakkottai, A.; Kaciroti, N.; Kasmikha, L.; Nasr, S.Z. Impact of home spirometry on medication adherence among adolescents with cystic fibrosis. Pediatr. Pulmonol. 2018, 53, 431–436. [Google Scholar] [CrossRef] [PubMed]
  23. Zanconato, S.; Meneghelli, G.; Braga, R.; Zacchello, F.; Baraldi, E. Office Spirometry in Primary Care Pediatrics: A Pilot Study. Pediatrics 2005, 116, e792–e797. [Google Scholar] [CrossRef] [PubMed]
  24. Exarchos, K.P.; Gogali, A.; Sioutkou, A.; Chronis, C.; Peristeri, S.; Kostikas, K. Validation of the portable Bluetooth® Air Next spirometer in patients with different respiratory diseases. Respir. Res. 2020, 21, 79. [Google Scholar] [CrossRef] [PubMed]
  25. Bastian-Lee, Y.; Chavasse, R.; Richter, H.; Seddon, P. Assessment of a low-cost home monitoring spirometer for children. Pediatr. Pulmonol. 2002, 33, 388–394. [Google Scholar] [CrossRef]
  26. Berlinski, A.; Leisenring, P.; Willis, L.; King, S. Home Spirometry in Children with Cystic Fibrosis. Bioengineering 2023, 10, 242. [Google Scholar] [CrossRef] [PubMed]
  27. Davies, B.; Kenia, P.; Nagakumar, P.; Gupta, A. Paediatric and adolescent asthma: A narrative review of telemedicine and emerging technologies for the post-COVID-19 era. Clin. Exp. Allergy 2021, 51, 393–401. [Google Scholar] [CrossRef]
  28. Paynter, A.; Khan, U.; Heltshe, S.L.; Goss, C.H.; Lechtzin, N.; Hamblett, N.M. A comparison of clinic and home spirometry as longitudinal outcomes in cystic fibrosis. J. Cyst. Fibros. 2021, 21, 78–83. [Google Scholar] [CrossRef] [PubMed]
  29. Edmondson, C.; Westrupp, N.; Short, C.; Seddon, P.; Olden, C.; Wallis, C.; Brodlie, M.; Baxter, F.; McCormick, J.; MacFarlane, S. Unsupervised home spirometry is not equivalent to supervised clinic spirometry in children and young people with cystic fibrosis: Results from the CLIMB-CF study. Pediatr. Pulmonol. 2023, 58, 2871–2880. [Google Scholar] [CrossRef] [PubMed]
  30. Oppenheimer, J.; Hanania, N.A.; Chaudhuri, R.; Sagara, H.; Bailes, Z.; Fowler, A.; Peachey, G.; Pizzichini, E.; Slade, D. Clinic vs Home Spirometry for Monitoring Lung Function in Patients with Asthma. Chest 2023, 164, 1087–1096. [Google Scholar] [CrossRef]
  31. Stanojevic, S.; Kaminsky, D.A.; Miller, M.R.; Thompson, B.; Aliverti, A.; Barjaktarevic, I.; Cooper, B.G.; Culver, B.; Derom, E.; Hall, G.L.; et al. ERS/ATS technical standard on interpretive strategies for routine lung function tests. Eur. Respir. J. 2022, 60, 2101499. [Google Scholar] [CrossRef] [PubMed]
  32. Anand, R.; McLeese, R.; Busby, J.; Stewart, J.; Clarke, M.; Man, W.D.C.; Bradley, J. Unsupervised home spirometry versus supervised clinic spirometry for respiratory disease: A systematic methodology review and meta-analysis. Eur. Respir. Rev. 2023, 32, 220248. [Google Scholar] [CrossRef] [PubMed]
  33. Beaufils, F.; Enaud, R.; Gallode, F.; Boucher, G.; Macey, J.; Berger, P.; Fayon, M.; Bui, S. Adherence, reliability, and variability of home spirometry telemonitoring in cystic fibrosis. Front. Pediatr. 2023, 11, 1111088. [Google Scholar] [CrossRef] [PubMed]
  34. Sarfaraz, S.; Sund, Z.; Jarad, N. Real-time, once-daily monitoring of symptoms and FEV1 in cystic fibrosis patients—A feasibility study using a novel device. Clin. Respir. J. 2010, 4, 74–82. [Google Scholar] [CrossRef] [PubMed]
  35. Lechtzin, N.; Mayer-Hamblett, N.; West, N.E.; Allgood, S.; Wilhelm, E.; Khan, U.; Aitken, M.L.; Ramsey, B.W.; Boyle, M.P.; Mogayzel, P.J., Jr.; et al. Home Monitoring of Patients with Cystic Fibrosis to Identify and Treat Acute Pulmonary Exacerbations. eICE Study Results. Am. J. Respir. Crit. Care Med. 2017, 196, 1144–1151. [Google Scholar] [CrossRef] [PubMed]
  36. Stanbrook, M.B.; Corey, M.; Tullis, D.E. The repeatability of forced expiratory volume measurements in adults with cystic fibrosis. Chest 2004, 125, 150–155. [Google Scholar] [CrossRef] [PubMed]
  37. Oppelaar, M.C.; Emond, Y.; Bannier, M.A.G.E.; Reijers, M.H.E.; van der Vaart, H.; van der Meer, R.; Altenburg, J.; Conemans, L.; Rottier, B.L.; Nuijsink, M. Potential, Pitfalls, and Future Directions for Remote Monitoring of Chronic Respiratory Diseases: Multicenter Mixed Methods Study in Routine Cystic Fibrosis Care. J. Med. Internet Res. 2024, 26, e54942. [Google Scholar] [CrossRef] [PubMed]
Figure 1. BlandAltman plot of differences in FVC (lt and z-score), FEV1 (lt/s and z-score), and FEF25-75 (lt/s and z-score) between at-home and in-clinic measurements (red line represents the mean difference and green lines represent the 95% limits of agreement).
Figure 1. BlandAltman plot of differences in FVC (lt and z-score), FEV1 (lt/s and z-score), and FEF25-75 (lt/s and z-score) between at-home and in-clinic measurements (red line represents the mean difference and green lines represent the 95% limits of agreement).
Children 12 00277 g001
Table 1. Baseline characteristics of the study population (N = 48).
Table 1. Baseline characteristics of the study population (N = 48).
N (%), Mean (StDev)
Age
6–11 y.o7 (14.58)
12–17 y.o21 (43.75)
>18 y.o20 (41.67)
Gender
Male22 (45.83)
Female26 (54.17)
Pseudomonas colonization
None35 (72.92)
Intermittent9 (18.75)
Chronic4 (8.33)
Disease severity
Mild (ppFEV1 > 80%)34 (70.83)
Moderate (ppFEV1 60–80%)8 (16.67)
Severe (ppFEV1 < 60%)6 (12.50)
Mutations
ΔF508/ΔF50820 (41.67)
ΔF508/other20 (41.67)
None8 (16.67)
Spirometry dataMean (sd)
FVC (lt)3.27 (1.03)
FVC pp94.03 (25.56)
FEV1 (lt)2.59 (0.86)
FEV1 pp84.98 (20.94)
FEF25-75 (lt/sec)2.49 (1.26)
FEF25-75 pp69.89 (29.57)
Table 2. Comparison of the spirometry parameters of 43 patients performing at-home and in-clinic spirometry.
Table 2. Comparison of the spirometry parameters of 43 patients performing at-home and in-clinic spirometry.
Home
Spirometry
Mean (SD)
Clinic
Spirometry
Mean (SD)
Mean
Difference
(95% CI)
p-Value95% LoA
FVC (lt)3.27 (1.05)3.63 (1.35)−0.37
(−0.54, −0.19)
<0.001 *−1.66, +0.96
FVC z-score−0.72 (1.38)0.03 (1.92)−0.76
(−1.17, −0.34)
0.001 *−3.89, +2.27
FEV1
(lt)
2.59 (0.91)2.81 (1.11)−0.22
(−0.32, −0.12)
<0.001 *−1.04, +0.60
FEV1 z-score−1.34 (1.58)−0.77 (2.02)−0.58
(−0.85, −0.30)
<0.001 *−2.83, +1.59
FEF25-75 (lt/s)2.50 (1.34)2.44 (1.40)0.06
(−0.13, 0.25)
0.526−1.74, +1.81
FEF25-75 z-score−1.54 (1.67)−1.72 (1.72)0.18
(−0.09, 0.46)
0.189−2.47, +2.91
SD, standard deviation; LoA, limits of agreement; CI: confidence interval. * Statistically significant at the 5% level.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Sopiadou, A.; Gioulvanidou, M.; Kogias, C.; Chrysochoou, E.-A.; Kalaitzopoulou, I.; Hatziagorou, E. The Feasibility and Validity of Home Spirometry for People with Cystic Fibrosis: Is It Comparable to Spirometry in the Clinic? Children 2025, 12, 277. https://doi.org/10.3390/children12030277

AMA Style

Sopiadou A, Gioulvanidou M, Kogias C, Chrysochoou E-A, Kalaitzopoulou I, Hatziagorou E. The Feasibility and Validity of Home Spirometry for People with Cystic Fibrosis: Is It Comparable to Spirometry in the Clinic? Children. 2025; 12(3):277. https://doi.org/10.3390/children12030277

Chicago/Turabian Style

Sopiadou, Athina, Maria Gioulvanidou, Christos Kogias, Elissavet-Anna Chrysochoou, Ioustini Kalaitzopoulou, and Elpis Hatziagorou. 2025. "The Feasibility and Validity of Home Spirometry for People with Cystic Fibrosis: Is It Comparable to Spirometry in the Clinic?" Children 12, no. 3: 277. https://doi.org/10.3390/children12030277

APA Style

Sopiadou, A., Gioulvanidou, M., Kogias, C., Chrysochoou, E.-A., Kalaitzopoulou, I., & Hatziagorou, E. (2025). The Feasibility and Validity of Home Spirometry for People with Cystic Fibrosis: Is It Comparable to Spirometry in the Clinic? Children, 12(3), 277. https://doi.org/10.3390/children12030277

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop