Gold Nanoparticle-Based Composite Electrode for Sensitive Electrochemical Detection of Melamine
Abstract
1. Introduction
2. Materials and Methods
2.1. Materials and Reagents
2.2. Instrumentation
2.3. Synthesis of MWCNTS/g-C3N4/Au Electrode
2.4. Parameters for Electrochemical Testing
3. Results
3.1. Morphological Characterization of SEM
3.2. Electrochemical Performance Testing of MWCNTS/g-C3N4/Au Electrode
3.3. Sensitivity of MWCNTS/g-C3N4/Au Electrodes in Detecting Melamine
3.4. Test of the Anti-Interference Capability of MWCNTS/g-C3N4/Au Electrodes for Detecting Melamine
3.5. MWCNTS/g-C3N4/Au Electrode for Detecting Melamine in Milk
3.6. Repetitiveness and Stability of MWCNTS/g-C3N4/Au Electrodes
4. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Shalileh, F.; Sabahi, H.; Golbashy, M.; Dadmehr, M.; Hosseini, M. Recent Developments in DNA Nanostructure-Based Biosensors for the Detection of Melamine Adulteration in Milk. Microchem. J. 2023, 195, 109316. [Google Scholar] [CrossRef]
- Naeimi, R.; Safarpour, F.; Askari, H.; Ghasemi-Kasman, M. Current Insights into the Neurotoxicity of Melamine: A Comprehensive Review. Curr. Neuropharmacol. 2025, 23, 20–35. [Google Scholar] [CrossRef] [PubMed]
- Finete, V.D.L.M.; Gouvêa, M.M.; Marques, F.F.D.C.; Netto, A.D.P. Is It Possible to Screen for Milk or Whey Protein Adulteration with Melamine, Urea and Ammonium Sulphate, Combining Kjeldahl and Classical Spectrophotometric Methods? Food Chem. 2013, 141, 3649–3655. [Google Scholar] [CrossRef]
- Yang, H.; Wang, J.; Wu, Q.; Wang, Y.; Li, L.; Ding, B. Simple and Label-Free Fluorescent Detection of Melamine Based on Melamine–Thymine Recognition. Sensors 2018, 18, 2968. [Google Scholar] [CrossRef]
- Mauer, L.J.; Chernyshova, A.A.; Hiatt, A.; Deering, A.; Davis, R. Melamine Detection in Infant Formula Powder Using Near- and Mid-Infrared Spectroscopy. J. Agric. Food Chem. 2009, 57, 3974–3980. [Google Scholar] [CrossRef] [PubMed]
- Sun, J.; Zhang, X.; Cao, Y.; Zhao, Q.; Bao, E.; Lv, Y. Ovarian Toxicity in Female Rats after Oral Administration of Melamine or Melamine and Cyanuric Acid. PLoS ONE 2016, 11, e0149063. [Google Scholar] [CrossRef] [PubMed]
- Li, Y.; Xu, J.; Sun, C. Chemical Sensors and Biosensors for the Detection of Melamine. RSC Adv. 2015, 5, 1125–1147. [Google Scholar] [CrossRef]
- Hau, A.K.; Kwan, T.H.; Li, P.K. Melamine Toxicity and the Kidney. J. Am. Soc. Nephrol. 2009, 20, 245–250. [Google Scholar] [CrossRef]
- Gu, C.; Lan, T.; Shi, H.; Lu, Y. Portable Detection of Melamine in Milk Using a Personal Glucose Meter Based on an in Vitro Selected Structure-Switching Aptamer. Anal. Chem. 2015, 87, 7676–7682. [Google Scholar] [CrossRef]
- Kamil, G.; Uğur, Ş. Development of a Novel Amino-Silica Packed Column for HPLC Determination of Melamine in Infant Formula and Milk Powder Samples. J. Food Compos. Anal. 2025, 147, 108068. [Google Scholar] [CrossRef]
- Squadrone, S.; Ferro, G.L.; Marchis, D.; Mauro, C.; Palmegiano, P.; Amato, G.; Poma Genin, E.; Abete, M.C. Determination of Melamine in Feed: Validation of a Gas Chromatography–Mass Spectrometry Method According to 2004/882/CE Regulation. Food Control 2010, 21, 714–718. [Google Scholar] [CrossRef]
- Sun, F.; Liu, L.; Kuang, H.; Xu, C. Development of ELISA for Melamine Detection in Milk Powder. Food Agric. Immunol. 2013, 24, 79–86. [Google Scholar] [CrossRef]
- Wang, G.; Xu, J.; Chen, H. Progress in the Studies of Photoelectrochemical Sensors. Sci. China Ser. B-Chem. 2009, 52, 1789–1800. [Google Scholar] [CrossRef]
- Zhang, Y.; Niu, Q.; Gu, X.; Yang, N.; Zhao, G. Recent Progress on Carbon Nanomaterials for the Electrochemical Detection and Removal of Environmental Pollutants. Nanoscale 2019, 11, 11992–12014. [Google Scholar] [CrossRef]
- Tonelli, D.; Scavetta, E.; Gualandi, I. Electrochemical Deposition of Nanomaterials for Electrochemical Sensing. Sensors 2019, 19, 1186. [Google Scholar] [CrossRef]
- Zhang, F.; Liu, Y.; Wang, J.; Zhang, H.; Yu, W.; Sang, Y.; Liu, Y.; Yang, G.; Gao, F.; Wang, S.; et al. An Automated Microfluidic Biosensor with Bispecific Rabbit Monoclonal Antibody and Nanozyme-Bioenzyme Composite for Dual Antibiotic Detection. BMEMat 2026, 4, e70039. [Google Scholar] [CrossRef]
- Zhang, K.; Han, L.; Cai, H.-Q.; Xue, X.-Y.; Song, Y.-F.; Xin, W.-L.; Wang, Y.-Z.; Liu, P.; Liu, J. Toward Personalized Healthcare: Advances in Two-Dimensional Nanomaterial-Based Flexible Electrochemical Sensors for Physiological Monitoring. BMEMat 2025, e70047. [Google Scholar] [CrossRef]
- Xue, J.; Lee, P.T.; Compton, R.G. Electrochemical Detection of Melamine. Electroanalysis 2014, 26, 1454–1460. [Google Scholar] [CrossRef]
- An, Q.-Q.; Feng, X.-Z.; Zhou, Z.-F.; Zhan, T.; Lian, S.-F.; Zhu, J.; Han, G.-C.; Chen, Z.; Kraatz, H.-B. One Step Construction of an Electrochemical Sensor for Melamine Detection in Milk towards an Integrated Portable System. Food Chem. 2022, 383, 132403. [Google Scholar] [CrossRef] [PubMed]
- Daizy, M.; Tarafder, C.; Al-Mamun, M.R.; Liu, X.; Aly Saad Aly, M.; Khan, M.Z.H. Electrochemical Detection of Melamine by Using Reduced Graphene Oxide–Copper Nanoflowers Modified Glassy Carbon Electrode. ACS Omega 2019, 4, 20324–20329. [Google Scholar] [CrossRef] [PubMed]
- He, Y.; Liao, Y.; Zhang, B.; Xu, R.; Ma, Y.; Zhao, M.; Cui, H. Using the Photo-Enhanced Barrier Effect on Electrochemical Response for Highly Sensitive Detection of Melamine. Food Chem. 2024, 432, 137246. [Google Scholar] [CrossRef]
- Kalambate, R.P.; Kalambate, P.K.; Laiwattanapaisal, W. Revolutionizing Melamine Detection: Cutting-Edge Advances from Traditional Analyses to State-of-the-Art Electrochemical Sensors. Next Mater. 2024, 3, 100085. [Google Scholar] [CrossRef]
- Yu, C.; Hou, J.; Zhang, B.; Liu, S.; Pan, X.; Song, H.; Hou, X.; Yan, Q.; Zhou, C.; Liu, G.; et al. In-Situ Electrodeposition Synthesis of Z-Scheme rGO/g-C3N4/TNAs Photoelectrodes and Its Degradation Mechanism for Oxytetracycline in Dual-Chamber Photoelectrocatalytic System. J. Environ. Manag. 2022, 308, 114615. [Google Scholar] [CrossRef]
- Yao, S.; Lv, Y.; Wang, Q.; Yang, J.; Li, H.; Gao, N.; Zhong, F.; Fu, J.; Tang, J.; Wang, T.; et al. Facile Preparation of Highly Sensitive SERS Substrates Based on Gold Nanoparticles Modified Graphdiyne/Carbon Cloth. Appl. Surf. Sci. 2023, 609, 155098. [Google Scholar] [CrossRef]
- Waseem, R.; Nazli, Z.-H.; Huma, Z.E.; Naz, I.; Bano, N.; Sultan, M.; De Souza, P.M.; Jubeen, F. Zn-Sal/CuO Nanoflake-Based Electrochemical Sensor for High-Sensitivity Detection of Trace Melamine in Milk. J. Electrochem. Soc. 2025, 172, 057509. [Google Scholar] [CrossRef]
- Peng, J.; Feng, Y.; Han, X.-X.; Gao, Z.-N. Sensitive Electrochemical Detection of Melamine Based on Gold Nanoparticles Deposited on a Graphene Doped Carbon Paste Electrode. Anal. Methods 2016, 8, 2526–2532. [Google Scholar] [CrossRef]
- Tiwari, M.; Singh, A.; Dureja, S.; Basu, S.; Pattanayek, S.K. Au Nanoparticles Decorated ZnO/ZnFe2O4 Composite SERS-Active Substrate for Melamine Detection. Talanta 2022, 236, 122819. [Google Scholar] [CrossRef]
- J, G.; Manojkumar, P.A.; Koppole, K. Surfactant-Free Facile Synthesis of Ag/rGO Nanohybrid for SERS-Based Detection of Melamine. Plasmonics 2024, 19, 471–480. [Google Scholar] [CrossRef]
- Akbari-adergani, B.; Sadeghian, G.-H.; Alimohammadi, A.; Esfandiari, Z. Integrated Photografted Molecularly Imprinted Polymers with a Cellulose Acetate Membrane for the Extraction of Melamine from Dry Milk before HPLC Analysis. J. Sep. Sci. 2017, 40, 1361–1368. [Google Scholar] [CrossRef] [PubMed]
- Mohebbi, M.; Ghanbari, K.; Nejabati, F. Electrochemical Sensor Based on EDTA-Functionalized Polyorthophenylene Diamine g-C3N4 Nanocomposite for Determination of Melamine in Milk. J. Electroanal. Chem. 2023, 946, 117757. [Google Scholar] [CrossRef]
- El-Shahawi, M.S.; Khraibah, N.H. Development of a Highly Sensitive Voltametric Sensor for Trace Determination of Melamine Residues in Milk and Water Samples. Microchem. J. 2020, 157, 105087. [Google Scholar] [CrossRef]
- Khedr, A. Optimized Extraction Method for LC–MS Determination of Bisphenol a, Melamine and Di(2-Ethylhexyl) Phthalate in Selected Soft Drinks, Syringes, and Milk Powder. J. Chromatogr. B 2013, 930, 98–103. [Google Scholar] [CrossRef] [PubMed]
- Heydarian-Dehkordi, N.; Saei-Dehkordi, S.S.; Izadi, Z.; Ghasemi-Varnamkhasti, M. Development of an Ultrasensitive Molecularly Imprinted Poly-(Ortho-Phenylenediamine) Based Sensor for the Determination of Melamine Adulteration in Milk and Infant Formula. Food Sci. Nutr. 2022, 10, 3154–3164. [Google Scholar] [CrossRef] [PubMed]







| Add (nM) | Detect (nM) | Recovery (%) | RSD (n = 5) | |
|---|---|---|---|---|
| milk | 50 | 52 | 104 | 2.3 |
| 100 | 100 | 100 | 2.4 | |
| 200 | 192 | 96 | 2.7 | |
| 300 | 273 | 91 | 2.9 | |
| 500 | 425 | 85 | 2.6 |
| Methods | Sensor | Linear Range (M) | LOD (mol/L) | Reference |
|---|---|---|---|---|
| SERS | Au- ZZF(ZnO/ZnFe2O) | 7.92 × 10−6–3.9 × 10−5 | 3.9 × 10−5 | [27] |
| SERS | Ag/rGO | 1 × 10−8–1 × 10−3 | 1 × 10−6 | [28] |
| Electrochemical | MEL/Fc-ECG/SPCE | 2.0 × 10−6–2.0 × 10−5 | 1 × 10−7 | [19] |
| HPLC | - | 1.59 × 10−7–9.37 × 10−5 | 5.56 × 10−8 | [29] |
| Electrochemical | g-C3N4/POPD/EDTA | 1 × 10−7–1 × 10−4 | 9 × 10−9 | [30] |
| Electrochemical | P-Arg/rGO-CuNFs/GCE | 10 × 10−9–9.0 × 10−8 | 5 × 10−9 | [20] |
| Electrochemical | preanodized glassy carbon electrode | 2.0 × 10−9–8.0 × 10−9 | 6.0 × 10−10 | [31] |
| LC-MS | - | 9.5 × 10−8–7.9 × 10−6 | 9.5 × 10−11 | [32] |
| Electrochemical | AuNPs/MIP/RGO/PGE | 10−17–10−8 | 2.64 × 10−16 | [33] |
| Electrochemical | MWCNTS/g-C3N4/Au structure | 2 × 10−8–5 × 10−7 | 4.7 × 10−9 | This work |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Share and Cite
Cui, L.; Fan, K.; Ma, J.; Lu, Y.; Wang, Y.; Yang, J. Gold Nanoparticle-Based Composite Electrode for Sensitive Electrochemical Detection of Melamine. Chemosensors 2026, 14, 133. https://doi.org/10.3390/chemosensors14060133
Cui L, Fan K, Ma J, Lu Y, Wang Y, Yang J. Gold Nanoparticle-Based Composite Electrode for Sensitive Electrochemical Detection of Melamine. Chemosensors. 2026; 14(6):133. https://doi.org/10.3390/chemosensors14060133
Chicago/Turabian StyleCui, Liqin, Kun Fan, Jia Ma, Yun Lu, Yanfang Wang, and Jiao Yang. 2026. "Gold Nanoparticle-Based Composite Electrode for Sensitive Electrochemical Detection of Melamine" Chemosensors 14, no. 6: 133. https://doi.org/10.3390/chemosensors14060133
APA StyleCui, L., Fan, K., Ma, J., Lu, Y., Wang, Y., & Yang, J. (2026). Gold Nanoparticle-Based Composite Electrode for Sensitive Electrochemical Detection of Melamine. Chemosensors, 14(6), 133. https://doi.org/10.3390/chemosensors14060133