Next Article in Journal
Near-Infrared-Activated MoS2(S)–Ag3PO4 Coating for Rapid Bacteria-Killing
Previous Article in Journal
Biopolymers for Food Packaging and Biomedical Applications: Options or Obligations?
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Study on the Contamination Characteristics of V-Type Double Suspension Rod Insulators Based on the Influence of Wake Flow

School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China
*
Author to whom correspondence should be addressed.
Coatings 2022, 12(9), 1262; https://doi.org/10.3390/coatings12091262
Submission received: 30 June 2022 / Revised: 13 August 2022 / Accepted: 21 August 2022 / Published: 29 August 2022
(This article belongs to the Section Surface Characterization, Deposition and Modification)

Abstract

The insulators of the catenary of the Lanzhou-Xinjiang High-speed Railway in windy areas suffer from serious contamination, which has led to frequent flashover accidents. The catenary of the Lanzhou-Xinjiang High-speed Railway has adopted the unique external insulation of V-type double suspension rod insulators. To further determine the contamination characteristics of this type of insulator, a contamination simulation model of insulator is established in this paper based on the principles of fluid mechanics, which is used to analyze the contamination characteristics of the V-type double suspension rod insulators under the influence of wake flow. The research results show that wind speed directly determines the static pressure on the surface of the insulator, the wind speed and particle concentration are proportional to the contamination volumes on the windward and crosswind sides of insulator, while the particle size is inversely proportional to the contamination volume on the leeward side of the insulator. The direction of wake flow is consistent with the direction angle of external incoming flow, and the wake flow generating area affects the contamination characteristics of the insulator. When the incoming flow is at a prevailing wind direction of 0°, focus should be put on the windward and crosswind sides of the two insulators during insulator cleaning, and the contamination distributions on these two insulators are similar; when the incoming flow is at a prevailing wind elevation of 0°∼60°, focus should be put on the entire surface of 1# insulator and the windward and crosswind sides of 2# insulator during insulator cleaning.
Keywords: V-type double suspension rod insulators; fluid mechanics; static pressure on surface; contamination volume fraction; impact of wake flow; contamination characteristics V-type double suspension rod insulators; fluid mechanics; static pressure on surface; contamination volume fraction; impact of wake flow; contamination characteristics

Share and Cite

MDPI and ACS Style

Zhao, S.; Wang, T.; Zhang, Y.; Liu, Y. Study on the Contamination Characteristics of V-Type Double Suspension Rod Insulators Based on the Influence of Wake Flow. Coatings 2022, 12, 1262. https://doi.org/10.3390/coatings12091262

AMA Style

Zhao S, Wang T, Zhang Y, Liu Y. Study on the Contamination Characteristics of V-Type Double Suspension Rod Insulators Based on the Influence of Wake Flow. Coatings. 2022; 12(9):1262. https://doi.org/10.3390/coatings12091262

Chicago/Turabian Style

Zhao, Shanpeng, Tianyu Wang, Youpeng Zhang, and Yuantao Liu. 2022. "Study on the Contamination Characteristics of V-Type Double Suspension Rod Insulators Based on the Influence of Wake Flow" Coatings 12, no. 9: 1262. https://doi.org/10.3390/coatings12091262

APA Style

Zhao, S., Wang, T., Zhang, Y., & Liu, Y. (2022). Study on the Contamination Characteristics of V-Type Double Suspension Rod Insulators Based on the Influence of Wake Flow. Coatings, 12(9), 1262. https://doi.org/10.3390/coatings12091262

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop