Probabilistic Safe Zone Mapping for S1 Screw Placement Using 1000 Lumbosacral CT Scans: A Study Protocol for a Bilateral, Two-Rater, Multi-Offset Anatomical Modeling Study
Abstract
1. Introduction
2. Materials and Methods
2.1. Study Design and Data Source
2.2. Definition of the Standardized S1 Entry Point
2.3. Directional and Offset-Based Evaluation
2.4. Rating Procedure and Outcome Definition
2.5. Data Structure
2.6. Materials and Equipment
2.6.1. CT Datasets and Imaging Parameters
2.6.2. Image Processing and Visualization Software
2.6.3. Hardware and Display Conditions
2.6.4. Data Handling and Documentation
2.7. Detailed Procedure
- Step 1: Dataset screening and eligibility
- Step 2: Standardized image orientation
- Step 3: Definition of the reference entry point
- Step 4: Offset-based trajectory assessment
- Step 5: Binary classification and data recording
- Step 6: Interobserver assessment
- Step 7: Aggregation and probabilistic modeling
2.8. Statistical Analysis
3. Expected Results
4. Timeline and Review Status
Supplementary Materials
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- de Ridder, V.A.; Whiting, P.S.; Balogh, Z.J.; Mir, H.R.; Schultz, B.J.; Routt, M.C. Pelvic ring injuries: Recent advances in diagnosis and treatment. OTA Int. 2023, 6, e261. [Google Scholar] [CrossRef] [PubMed]
- Matta, J.M.; Saucedo, T. Internal fixation of pelvic ring fractures. Clin. Orthop. Relat. Res. 1989, 242, 83–97. [Google Scholar] [CrossRef]
- Yin, Y.; Hou, Z.; Zhang, R.; Jin, L.; Chen, W.; Zhang, Y. Percutaneous Placement of Iliosacral Screws Under the Guidance of Axial View Projection of the S1 Pedicle: A Case Series. Sci. Rep. 2017, 7, 7925. [Google Scholar] [CrossRef] [PubMed]
- Hilgert, R.E.; Finn, J.; Egbers, H.J. Technik der perkutanen SI-Verschraubung mit Unterstützung durch konventionellen C-Bogen [Technique for percutaneous iliosacral screw insertion with conventional C-arm radiography]. Unfallchirurg 2005, 108, 954–960. (In German) [Google Scholar] [CrossRef] [PubMed]
- Tosounidis, G.; Culemann, U.; Wirbel, R.; Holstein, J.H.; Pohlemann, T. Die perkutane transiliosakrale Zugschraubenosteosynthese des hinteren Beckenrings. Erhöhte Sicherheit durch Standardisierung von Visualisierung und Technik [Percutaneous sacroiliac lag screw fixation of the posterior pelvic ring. Increasing safety by standardization of visualization and insertion technique]. Unfallchirurg 2007, 110, 669–674. (In German) [Google Scholar] [CrossRef] [PubMed]
- Shrestha, D.; Dhoju, D.; Shrestha, R.; Sharma, V. Percutaneous Ilio-Sacral Screw Fixation in Supine Position under Fluoroscopy Guidance. Kathmandu Univ. Med. J. 2015, 13, 56–60. [Google Scholar] [CrossRef] [PubMed][Green Version]
- Day, C.S.; Prayson, M.J.; Shuler, T.E.; Towers, J.; Gruen, G.S. Transsacral versus modified pelvic landmarks for percutaneous iliosacral screw placement–a computed tomographic analysis and cadaveric study. Am. J. Orthop. 2000, 29, 16–21. [Google Scholar] [PubMed]
- Ebraheim, N.A.; Lin, D.; Xu, R.; Yeasting, R.A. Evaluation of the upper sacrum by three-dimensional computed tomography. Am. J. Orthop. 1999, 28, 578–582. [Google Scholar] [PubMed]
- Herman, A.; Keener, E.; Dubose, C.; Lowe, J.A. Simple mathematical model of sacroiliac screws safe-zone-Easy to implement by pelvic inlet and outlet views. J. Orthop. Res. 2017, 35, 1478–1484. [Google Scholar] [CrossRef] [PubMed]
- McLaren, D.A.; Busel, G.A.; Parikh, H.R.; Only, A.; Patterson, J.; Gaston, B.T.; McLemore, R.; Cunningham, B. Corridor-diameter-dependent angular tolerance for safe transiliosacral screw placement: An anatomic study of 433 pelves. Eur. J. Orthop. Surg. Traumatol. 2021, 31, 1485–1492. [Google Scholar] [CrossRef] [PubMed]
- Aregger, F.C.; Gewiess, J.; Albers, C.E.; Deml, M.C.; Schaible, S.; Hoppe, S.; Tinner, C. Evaluation of the true lateral fluoroscopic projection for the relation of the S1 recess/foramen to safe corridors in transiliac-transsacral screw placement in human cadaveric pelves. Eur. J. Orthop. Surg. Traumatol. 2024, 35, 31. [Google Scholar] [CrossRef] [PubMed]
- Chen, J.P.; Tsai, P.J.; Su, C.Y.; Tseng, I.C.; Chou, Y.C.; Chen, I.J.; Lee, P.W.; Yu, Y.H. Percutaneous iliosacral screw and trans-iliac trans-sacral screw with single C-arm fluoroscope intensifier is a safe treatment for pelvic ring injuries. Sci. Rep. 2022, 12, 368. [Google Scholar] [CrossRef] [PubMed]
- Tejwani, N.C.; Raskolnikov, D.; McLaurin, T.; Takemoto, R. The role of computed tomography for postoperative evaluation of percutaneous sacroiliac screw fixation and description of a “safe zone”. Am. J. Orthop. 2014, 43, 513–516. [Google Scholar] [PubMed]
- Chancharoen, W.; Nwe, T.; Seehanam, S.; Taradolpisut, N.; Berkband, T.; Chobpenthai, T.; Jongwannasiri, C.; Yurasakpong, L. Evaluation of screw pull-out from plate fixation of en bloc distal radius resection with ulnar reconstruction: Finite element analysis and comparison with experiments on Thiel cadavers. APL Bioeng. 2025, 9, 026123. [Google Scholar] [CrossRef] [PubMed]
- Jin, L.; Hao, X.; Zhang, Z.; Zhang, Q.; Zhang, S.; Zhou, F.; Yang, S.; Zheng, W.; Xiong, X.; Gong, W.; et al. New Minimally Invasive Method for Treating Posterior Pelvic Ring Fractures: Biomechanical Validation and Clinical Application of Sacroiliac Joint Locking Plate. Orthop. Surg. 2025, 17, 1433–1446. [Google Scholar] [CrossRef] [PubMed]
- Kułakowski, M.; Elster, K.; Reichert, P.; Królikowska, A.; Jerominko, J.; Ślęczka, P.; Grzonkowska, M.; Szpinda, M.; Baumgart, M. Anatomy of the sacroiliac joint with relation to the lumbosacral trunk: Is there sufficient space for a two-hole plate? PLoS ONE 2023, 18, e0292620. [Google Scholar] [CrossRef] [PubMed]
- Yang, Z.; Sheng, B.; Liu, D.; Wang, Y.; Liu, C.; Xiao, R. Sacroiliac screws fixation navigated with three-dimensional printing personalized guide template for the treatment of posterior pelvic ring injury: A case report. Front. Surg. 2023, 9, 1025650. [Google Scholar] [CrossRef] [PubMed]
- Yang, C.; Liu, G.; Tang, J.; Li, G.; Qin, X.; Hu, J. TiRobot-assisted percutaneous sacroiliac cannulated screw fixation for posterior pelvic ring injury with sacral variations. Chin. J. Reparative Reconstr. Surg. 2022, 36, 940–945. (In Chinese) [Google Scholar] [CrossRef]
- Wang, H.; Fu, Y.H.; Ke, C.; Zhuang, Y.; Zhang, K.; Wei, X.; Li, Z.; Lei, J.L.; Zhang, B.F.; Liu, P. Minimally invasive stabilisation of posterior pelvic ring instabilities with pedicle screws connected to a transverse rod. Int. Orthop. 2018, 42, 681–686. [Google Scholar] [CrossRef] [PubMed]
- Ramadanov, N.; Zabler, S. Ramadanov-Zabler Safe Zone for Sacroiliac Screw Placement: A CT-Based Computational Pilot Study. J. Clin. Med. 2025, 14, 3567. [Google Scholar] [CrossRef] [PubMed]

Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Share and Cite
Ramadanov, N.; Hable, R.; Zabler, S.; Michael, L.; Becker, R. Probabilistic Safe Zone Mapping for S1 Screw Placement Using 1000 Lumbosacral CT Scans: A Study Protocol for a Bilateral, Two-Rater, Multi-Offset Anatomical Modeling Study. J. Clin. Med. 2026, 15, 1323. https://doi.org/10.3390/jcm15041323
Ramadanov N, Hable R, Zabler S, Michael L, Becker R. Probabilistic Safe Zone Mapping for S1 Screw Placement Using 1000 Lumbosacral CT Scans: A Study Protocol for a Bilateral, Two-Rater, Multi-Offset Anatomical Modeling Study. Journal of Clinical Medicine. 2026; 15(4):1323. https://doi.org/10.3390/jcm15041323
Chicago/Turabian StyleRamadanov, Nikolai, Robert Hable, Simon Zabler, Linus Michael, and Roland Becker. 2026. "Probabilistic Safe Zone Mapping for S1 Screw Placement Using 1000 Lumbosacral CT Scans: A Study Protocol for a Bilateral, Two-Rater, Multi-Offset Anatomical Modeling Study" Journal of Clinical Medicine 15, no. 4: 1323. https://doi.org/10.3390/jcm15041323
APA StyleRamadanov, N., Hable, R., Zabler, S., Michael, L., & Becker, R. (2026). Probabilistic Safe Zone Mapping for S1 Screw Placement Using 1000 Lumbosacral CT Scans: A Study Protocol for a Bilateral, Two-Rater, Multi-Offset Anatomical Modeling Study. Journal of Clinical Medicine, 15(4), 1323. https://doi.org/10.3390/jcm15041323

