Retrospective Analysis of IOL Power Calculation by Ray Tracing in Eyes with Previous Radial Keratotomy
Abstract
1. Introduction
2. Materials and Methods
2.1. Preoperative Measurements and Surgery
2.2. Intraocular Lens Power Calculation
2.3. Statistics
3. Results
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
Abbreviations
| D | Diopters |
| RK | Radial keratotomy |
| PE | Prediction error |
| AL | Axial length |
| IOL | Intraocular lens |
| HOAs | Higher order aberrations |
| SD | Standard deviation |
| MAE | Mean absolute error |
| MedAE | Median absolute error |
References
- Hoffer, K.J. Intraocular lens power calculation after previous laser refractive surgery. J. Cataract. Refract. Surg. 2009, 35, 759–765. [Google Scholar] [CrossRef] [PubMed]
- Camellin, M.; Savini, G.; Hoffer, K.J.; Carbonelli, M.; Barboni, P. Scheimpflug camera measurements of anterior and posterior corneal curvature in eyes with previous radial keratotomy. J. Refract. Surg. 2012, 28, 275–279. [Google Scholar] [CrossRef] [PubMed]
- Schanzlin, D.J.; Santos, V.R.; Waring, G.O., III; Lynn, M.; Bourque, L.; Cantillo, N.; Edwards, M.A.; Justin, N.; Reinig, J.; Roszka-Duggan, V. Diurnal change in refraction, corneal curvature, visual acuity, and intraocular pressure after radial keratotomy in the PERK study. Ophthalmogy 1986, 93, 167–175. [Google Scholar] [CrossRef] [PubMed]
- Voytsekhivskyy, O. The VRF-L and VRF-G IOL power calculation methods after radial keratotomy. Eye 2024, 38, 2947–2954. [Google Scholar] [CrossRef]
- Wang, L.; Spektor, T.; de Souza, R.G.; Koch, D.D. Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery. J. Cataract. Refract. Surg. 2019, 45, 1416–1421. [Google Scholar] [CrossRef]
- Morshifar, M.; Sperry, R.A.; Altaf, A.W.; Stoakes, I.M.; Hoopes, P.C. Predictability of existing IOL formulas after cataract surgery in patients with a previous history of radial keratotomy: A retrospective cohort study and literature review. Ophthalmol. Ther. 2024, 13, 1703–1722. [Google Scholar] [CrossRef]
- Helaly, H.A.; Elhady, A.M.; Elnaggar, O.R. Accuracy of traditional and modern formulas for intraocular lens power calculation after radial keratotomy using standard keratometry. Clin. Ophthalmol. 2023, 17, 2589–2597. [Google Scholar] [CrossRef]
- Shetty, N.; Sathe, P.; Aishwarya Francis, M.; Shetty, R. Comparison of intraocular lens power prediction accuracy of formulas in American Society of Cataract and Refractive Surgery post-refractive surgery calculator in eyes with prior radial keratotomy. Indian J. Ophthalmol. 2023, 71, 3224–3228. [Google Scholar] [CrossRef]
- Ma, J.X.; Tang, M.; Wang, L.; Weikert, M.P.; Huang, D.; Koch, D.D. Comparison of newer IOL power calculation methods for eyes with previous radial keratotomy. Investig. Ophthalmol. Vis. Sci. 2016, 57, 162–168. [Google Scholar] [CrossRef]
- Kohnen, T.; Schug, T.; Kolb-Wetterau, C.; Jandewerth, T.; Bucur, J.; Lwowski, C.; Kaiser, K.P. Accuracy of intraocular lens calculation in a non-diffractive extended depth of focus intraocular lens after myopic LASIK. J. Refract. Surg. 2025, 41, e950–e957. [Google Scholar] [CrossRef]
- Anter, A.M.; Bleeker, A.R.; Shammas, H.J.; Suraneni, S.; Kingrey, B.; Murphy, D.A.; Leal, S.; Ghalibafan, S.; Tonk, R.S.; Cooke, D.L.; et al. Comparison of legacy and new no-history IOL power calculation formulas in postmyopic laser vision correction eyes. Am. J. Ophthalmol. 2024, 264, 44–52. [Google Scholar] [CrossRef]
- Turnbull, A.M.J.; Crawford, G.J.; Barrett, G.D. Methods for intraocular lens power calculation in cataract surgery after radial keratotomy. Ophthalmology 2020, 127, 45–51. [Google Scholar] [CrossRef] [PubMed]
- Savini, G.; Hoffer, K.J.; Ribeiro, F.J.; Mendanha Dias, J.; Coutinho, C.P.; Barboni, P.; Schiano-Lomoriello, D. Intraocular lens power calculation with ray tracing based on AS-OCT and adjusted axial length after myopic excimer laser surgery. J. Cataract. Refract. Surg. 2022, 48, 947–953. [Google Scholar] [CrossRef] [PubMed]
- Savini, G.; Schiano-Lomoriello, D.; Hoffer, K.J. Repeatability of automatic measurements by a new anterior segment optical coherence tomographer combined with Placido topography and agreement with 2 Scheimpflug cameras. J. Cataract. Refract. Surg. 2018, 44, 471–478. [Google Scholar] [CrossRef] [PubMed]
- Wang, L.; Holladay, J.T.; Koch, D.D. Wang-Koch axial length adjustment for the Holladay 2 formula in long eyes. J. Cataract. Refract. Surg. 2018, 44, 1291–1292, Errata: J. Cataract. Refract. Surg. 2019, 45, 117. [Google Scholar] [CrossRef]
- Debellemanière, G.; Mechleb, N.; Bernier, T.; Ancel, J.M.; Gauvin, M.; Wallerstein, A.; Saad, A.; Gatinel, D. The development of a thick-lens post-myopic laser vision correction intraocular lens calculation formula. Am. J. Ophthalmol. 2024, 262, 40–47. [Google Scholar] [CrossRef]
- Haigis, W.; Lege, B.; Miller, N.; Schneider, B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefe’s Arch. Clin. Exp. Ophthalmol. 2000, 238, 765–773. [Google Scholar] [CrossRef]
- Kan Tor, Y.; Abulafia, A.; Zadok, D.; Kohnen, T.; Savini, G.; Hoffer, K.J.; Yuval, B. Spherical equivalent prediction analysis in intraocular lens power calculations using Eyetemis: A comprehensive approach. J. Cataract. Refract. Surg. 2024, 50, 1128–1134. [Google Scholar] [CrossRef]
- Savini, G.; Barboni, P.; Carbonelli, M.; Ducoli, P.; Hoffer, K.J. Intraocular lens power calculation after myopic excimer laser surgery: Selecting the best method using available clinical data. J. Cataract. Refract. Surg. 2015, 41, 1880–1888. [Google Scholar] [CrossRef]
- Aramberri, J. Intraocular lens power calculation after corneal refractive surgery: Double-K method. J. Cataract. Refract. Surg. 2003, 29, 2063–2068. [Google Scholar] [CrossRef]
- Srujana, D.; Shankar, S.; Bhanot, R.; Mohandas, R.; Srikanth, S.; Kumar, A. Ray tracing biometry in post radial keratotomy eye. Eur. J. Ophthalmol. 2023, 33, NP19–NP22. [Google Scholar] [CrossRef]
| Mean ± SD | Range (min/max) | |
|---|---|---|
| Keratometry flat (D) | 34.59 ± 4.01 | 26.86/41.59 |
| Keratometry steep (D) | 36.57 ± 3.41 | 29.34/41.76 |
| Keratometry average (D) | 35.53 ± 3.66 | 28.08/41.68 |
| Posterior keratometry flat (D) | −4.38 ± 0.66 | −5.41/−3.1 |
| Posterior keratometry steep (D) | −4.74 ± 0.50 | −5.49/−3.82 |
| Posterior keratometry average (D) | −4.54 ± 0.58 | −5.45/−3.44 |
| Total keratometry (D) | 35.47 ± 3.67 | 28.25/41.83 |
| Anterior chamber depth (mm) * | 3.34 ± 0.33 | 2.67/3.93 |
| Lens thickness | 4.45 ± 0.35 | 4.01/5.2 |
| Axial length | 27.33 ± 2.94 | 23.42/33.13 |
| Mean PE ± SD (D) | MAE (D) | MedAE (D) | PE ≤ ±0.25 D | PE ≤ ±0.50 D | PE ≤ ±0.75 D | PE ≤ ±1.00 D | |
|---|---|---|---|---|---|---|---|
| Ray tracing | 0.01 ± 0.69 | 0.54 | 0.48 | 25% | 65% | 85% | 90% |
| Barrett True-K P-PCA | −0.19 ± 0.74 | 0.56 | 0.44 | 35% | 55% | 80% | 85% |
| Barrett True-K M-PCA | −0.05 ± 0.81 | 0.60 | 0.36 | 25% | 60% | 70% | 80% |
| EVO P-PCA | −0.02 ± 0.74 | 0.53 | 0.35 | 40% | 55% | 70% | 80% |
| EVO M-PCA | −0.13 ± 0.76 | 0.58 | 0.50 | 35% | 50% | 70% | 70% |
| Haigis-TK | −0.28 ± 0.73 | 0.55 | 0.33 | 40% | 65% | 75% | 80% |
| PEARL-DGS | 0.00 ± 0.66 | 0.52 | 0.50 | 35% | 50% | 70% | 90% |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Share and Cite
Savini, G.; Hoffer, K.J.; Grendele, A.; Coutinho, C.P.; Russo, A.; Schiano-Lomoriello, D. Retrospective Analysis of IOL Power Calculation by Ray Tracing in Eyes with Previous Radial Keratotomy. J. Clin. Med. 2026, 15, 866. https://doi.org/10.3390/jcm15020866
Savini G, Hoffer KJ, Grendele A, Coutinho CP, Russo A, Schiano-Lomoriello D. Retrospective Analysis of IOL Power Calculation by Ray Tracing in Eyes with Previous Radial Keratotomy. Journal of Clinical Medicine. 2026; 15(2):866. https://doi.org/10.3390/jcm15020866
Chicago/Turabian StyleSavini, Giacomo, Kenneth J. Hoffer, Arianna Grendele, Catarina P. Coutinho, Andrea Russo, and Domenico Schiano-Lomoriello. 2026. "Retrospective Analysis of IOL Power Calculation by Ray Tracing in Eyes with Previous Radial Keratotomy" Journal of Clinical Medicine 15, no. 2: 866. https://doi.org/10.3390/jcm15020866
APA StyleSavini, G., Hoffer, K. J., Grendele, A., Coutinho, C. P., Russo, A., & Schiano-Lomoriello, D. (2026). Retrospective Analysis of IOL Power Calculation by Ray Tracing in Eyes with Previous Radial Keratotomy. Journal of Clinical Medicine, 15(2), 866. https://doi.org/10.3390/jcm15020866