Next Article in Journal
Multi-Stage Cascaded Deep Learning-Based Model for Acute Aortic Syndrome Detection: A Multisite Validation Study
Next Article in Special Issue
High Radial Artery Puncture Reduces CRPS Risk for Women: A Retrospective Case Series
Previous Article in Journal
E-Gastryal® + Magnesium Alginate Plus PPI vs. PPI Alone in GERD: Results from the GENYAL® Randomized Controlled Trial
Previous Article in Special Issue
Use of Cell Saver in Elective Coronary Bypass Surgery: What Do We Risk When Saving Blood?
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Prophylactic Intra-Aortic Balloon Pump Implantation Reduces Peri-Interventional Myocardial Injury During High-Risk Percutaneous Coronary Intervention in Patients Presenting with Low Normal Blood Pressure and with Heart Failure

by
Sascha d’Almeida
1,*,†,
Stefanie Andreß
1,*,†,
Sebastian Weinig
1,
Benjamin Mayer
2,
Wolfgang Rottbauer
1,
Sinisa Markovic
1,‡ and
Dominik Buckert
1,‡
1
Department of Cardiology, Angiology, Pneumology, and Intensive Care Medicine, Ulm University Hospital, 89075 Ulm, Germany
2
Institute for Epidemiology and Medical Biometry, Ulm University, 89075 Ulm, Germany
*
Authors to whom correspondence should be addressed.
These authors contributed equally to this work and share first authorship.
These authors contributed equally to this work and share last authorship.
J. Clin. Med. 2025, 14(13), 4796; https://doi.org/10.3390/jcm14134796
Submission received: 21 June 2025 / Revised: 3 July 2025 / Accepted: 5 July 2025 / Published: 7 July 2025
(This article belongs to the Special Issue Clinical Management for Coronary Artery Disease and Revascularization)

Abstract

Background: Intra-aortic balloon pump (IABP) augments coronary perfusion during high-risk percutaneous coronary interventions (PCI). We sought to identify patients who benefited from prophylactic IABP (P-IABP) compared to rescue-IABP (R-IABP). Methods: All consecutive non-cardiogenic shock patients undergoing high-risk PCI with IABP support at Ulm University Hospital, Germany, between 2012 and 2020 were grouped based on the timing of IABP insertion in the pre-interventional P-IABP or peri-interventional R-IABP group. We compared the primary endpoint peri-interventional high-sensitivity Troponin T (hsTnT) increase, sought baseline characteristics associated with the endpoint in the R-IABP group, and compared their correlation strengths between the groups. Results: Interventional outcomes of 44 patients with P-IABP implantation were compared with those of 15 patients with R-IABP implantation. P-IABP was associated with a lower peri-interventional hsTnT increase (p = 0.008, r = 0.390). In the R-IABP group, the presence of ST-segment elevation (p = 0.037, r = 0.631), low systolic blood pressure (RRsyst) (p = 0.007, r = 0.893 (inverse correlation)), and elevated NT-proBNP levels (p < 0.001, r = 0.953) were associated with higher hsTnT increases. HsTnT increase was significantly smaller in the P-IABP group in patients with low RRsyst (IZI = 2.6) and high NT-proBNP levels (IZI = 3.36). Patients with RRsyst < 120 mmHg (p = 0.007) and NT-proBNP levels ≥ 900 pg/mL (Cohen’s d = 0.70, respectively 1.17 for ≥5000 pg/mL and 5.01 for ≥10,000 pg/mL) showed lower peri-interventional hsTnT increase when treated with P-IABP compared to R-IABP, while patients with NT-proBNP levels < 900 pg/mL showed a contrary effect (Cohen’s d = −0.90). Cox regression analysis showed that a high peri-interventional hsTnT increase was significantly associated with a shorter survival time (p = 0.046). Conclusions: P-IABP use in high-risk PCI was associated with reduced peri-interventional myocardial injury, as measured by lower hsTnT increase, which was associated with improved survival in patients with low systolic blood pressure and elevated NT-proBNP levels. Thus, these conditions should be considered for indicating P-IABP.
Keywords: IABP; intra-aortic balloon pump; prophylaxis; high-risk PCI; high-risk Percutaneous Coronary Intervention; myocardial injury; blood pressure; heart failure IABP; intra-aortic balloon pump; prophylaxis; high-risk PCI; high-risk Percutaneous Coronary Intervention; myocardial injury; blood pressure; heart failure
Graphical Abstract

Share and Cite

MDPI and ACS Style

d’Almeida, S.; Andreß, S.; Weinig, S.; Mayer, B.; Rottbauer, W.; Markovic, S.; Buckert, D. Prophylactic Intra-Aortic Balloon Pump Implantation Reduces Peri-Interventional Myocardial Injury During High-Risk Percutaneous Coronary Intervention in Patients Presenting with Low Normal Blood Pressure and with Heart Failure. J. Clin. Med. 2025, 14, 4796. https://doi.org/10.3390/jcm14134796

AMA Style

d’Almeida S, Andreß S, Weinig S, Mayer B, Rottbauer W, Markovic S, Buckert D. Prophylactic Intra-Aortic Balloon Pump Implantation Reduces Peri-Interventional Myocardial Injury During High-Risk Percutaneous Coronary Intervention in Patients Presenting with Low Normal Blood Pressure and with Heart Failure. Journal of Clinical Medicine. 2025; 14(13):4796. https://doi.org/10.3390/jcm14134796

Chicago/Turabian Style

d’Almeida, Sascha, Stefanie Andreß, Sebastian Weinig, Benjamin Mayer, Wolfgang Rottbauer, Sinisa Markovic, and Dominik Buckert. 2025. "Prophylactic Intra-Aortic Balloon Pump Implantation Reduces Peri-Interventional Myocardial Injury During High-Risk Percutaneous Coronary Intervention in Patients Presenting with Low Normal Blood Pressure and with Heart Failure" Journal of Clinical Medicine 14, no. 13: 4796. https://doi.org/10.3390/jcm14134796

APA Style

d’Almeida, S., Andreß, S., Weinig, S., Mayer, B., Rottbauer, W., Markovic, S., & Buckert, D. (2025). Prophylactic Intra-Aortic Balloon Pump Implantation Reduces Peri-Interventional Myocardial Injury During High-Risk Percutaneous Coronary Intervention in Patients Presenting with Low Normal Blood Pressure and with Heart Failure. Journal of Clinical Medicine, 14(13), 4796. https://doi.org/10.3390/jcm14134796

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop