Pullout Response of Ultra-High-Performance Concrete with Twisted Steel Fibers

College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310000, China
*
Author to whom correspondence should be addressed.
Appl. Sci. 2019, 9(4), 658; https://doi.org/10.3390/app9040658
Submission received: 30 January 2019 / Revised: 12 February 2019 / Accepted: 12 February 2019 / Published: 15 February 2019
(This article belongs to the Section Materials Science and Engineering)

Abstract

This paper aims to develop a pullout force formula and increase the understanding of the damage mechanisms of ultra-high-performance fiber reinforced concrete (UHPFRC) with twisted steel fibers (TSFs) through a pull-out test and finite element analysis (FEA). The formula was first obtained through a theoretical force analysis with model assumptions that are based on the experimental data in the literature. A microscale in-situ X-ray computed tomography (µXCT) was used to prepare 3D images of the cross-section of concrete before and after TSFs with three embedment lengths were pulled out. The tested pullout force values were used for comparison with the developed formula values. The µXCT images show the concrete matrix was preserved after the TSF was pulled out, indicating the stable pullout force values at the strain hardening stage was mainly caused by the fiber untwisting. FEA results show this untwisting behavior occurs on the effective untwisting length of TSF close to the exterior concrete surface. The theoretical formula values were found match well with the testing data. The developed formula is potentially used to analyze the pullout behavior of TSF with different geometries; thus, the design of the UHPFRC with TSFs can be optimized in the field.
Keywords: analytical model; finite element analysis; twisted steel fiber; ultra-high-performance concrete analytical model; finite element analysis; twisted steel fiber; ultra-high-performance concrete

Share and Cite

MDPI and ACS Style

Ye, J.; Liu, G. Pullout Response of Ultra-High-Performance Concrete with Twisted Steel Fibers. Appl. Sci. 2019, 9, 658. https://doi.org/10.3390/app9040658

AMA Style

Ye J, Liu G. Pullout Response of Ultra-High-Performance Concrete with Twisted Steel Fibers. Applied Sciences. 2019; 9(4):658. https://doi.org/10.3390/app9040658

Chicago/Turabian Style

Ye, Judong, and Guohua Liu. 2019. "Pullout Response of Ultra-High-Performance Concrete with Twisted Steel Fibers" Applied Sciences 9, no. 4: 658. https://doi.org/10.3390/app9040658

APA Style

Ye, J., & Liu, G. (2019). Pullout Response of Ultra-High-Performance Concrete with Twisted Steel Fibers. Applied Sciences, 9(4), 658. https://doi.org/10.3390/app9040658

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop