Next Article in Journal
Optimal Design Model of the Energy Systems in Iron and Steel Enterprises
Next Article in Special Issue
Shear Strength Prediction Equations and Experimental Study of High Strength Steel Fiber-Reinforced Concrete Beams with Different Shear Span-to-Depth Ratios
Previous Article in Journal
Voltage-Controlled Synthetic Inductors for Resonant Piezoelectric Shunt Damping: A Comparative Analysis
Previous Article in Special Issue
Axial Compressive Behavior of Steel-Damping-Concrete Composite Wall
Open AccessArticle

Temperature Distributions inside Concrete Sections of Renewable Energy Storage Pile Foundations

Department of Civil and Environmental Engineering, Nazarbayev University, Nur-Sultan 010000, Kazakhstan
*
Author to whom correspondence should be addressed.
Appl. Sci. 2019, 9(22), 4776; https://doi.org/10.3390/app9224776
Received: 9 September 2019 / Revised: 10 October 2019 / Accepted: 23 October 2019 / Published: 8 November 2019
A new pile foundation system is being developed for renewable energy storage through a multi-disciplinary research project. This system utilizes the compressed air technology to store renewable energy inside the reinforced concrete pile foundation configured with hollowed sections. The compressed air can result in high air pressure to which the structural response of the pile foundation subjected has been studied. However, the temperature in the pile foundation can be affected by the compressed air if sufficient cooling is not provided. The temperature change can generate thermal stresses and affect the structural safety of the pile foundation. As a first step to investigate this thermal effect, this paper studies temperature distributions inside the concrete section for the pile foundation through non-steady state heat transfer analyses. Several parameters were considered in the study, including thermal conductivities of the concrete, specific heat capacities of the concrete, and dimensions of the pile foundation. It has been found that the temperature distribution along the concrete section varies significantly during a daily energy storage cycle as well as subsequent cycles due to the cumulative effect of residual temperatures at the end of each cycle. The temperature distribution is largely affected by the thermal conductivity of the concrete and the geometry of the pile foundation. The obtained temperature distribution can be used for investigation of the thermal stress inside the foundation and surrounding soil. View Full-Text
Keywords: concrete pile foundation; compressed air; renewable energy storage; heat transfer analysis; non-steady state response concrete pile foundation; compressed air; renewable energy storage; heat transfer analysis; non-steady state response
Show Figures

Figure 1

MDPI and ACS Style

Zhang, D.; Mamesh, Z.; Sailauova, D.; Shon, C.-S.; Lee, D.; Kim, J.R. Temperature Distributions inside Concrete Sections of Renewable Energy Storage Pile Foundations. Appl. Sci. 2019, 9, 4776.

Show more citation formats Show less citations formats
Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Article Access Map by Country/Region

1
Back to TopTop