Abstract

The accuracy of dynamics parameters in the transmission system is essential for high-performance motion trajectory planning and stable operation of heavy-duty servo presses. To mitigate the performance degradation and potential overload risks caused by deviations between theoretical and actual parameters, this paper proposes a dynamics model accuracy enhancement method that integrates multi-objective global sensitivity analysis and ant colony optimization-based calibration. First, a nonlinear dynamics model of the eight-bar mechanism was constructed based on Lagrange’s equations, which systematically incorporates generalized external force models consistent with actual production, including gravity, friction, balance force, and stamping process load. Subsequently, six key sensitive parameters were identified from 28 system parameters using Sobol global sensitivity analysis, with response functions defined for torque prediction accuracy, transient overload risk, thermal load, and work done. Based on the sensitivity results, a parameter calibration model was formulated to minimize torque prediction error and transient overload risk, and solved by the ant colony algorithm. Experimental validation showed that, after calibration, the root mean square error between predicted and measured torque decreased significantly from 1366.9 N·m to 277.7 N·m (a reduction of 79.7%), the peak error dropped by 72.7%, and the servo motor’s effective torque prediction error was reduced from 7.6% to 1.4%. In an automotive door panel stamping application on a 25,000 kN heavy-duty servo press, the production rate increased from 11.4 to 11.6 strokes per minute, demonstrating enhanced performance without operational safety. This study provides a theoretical foundation and an effective engineering solution for high-precision modeling and performance optimization of heavy-duty servo presses.
Keywords: servo press; eight-bar mechanism; parameter calibration; global sensitivity analysis; dynamic modeling servo press; eight-bar mechanism; parameter calibration; global sensitivity analysis; dynamic modeling

Share and Cite

MDPI and ACS Style

Li, J.; Ma, S.; Liu, B.; Liu, T.; Wang, Z. Dynamics Parameter Calibration for Performance Enhancement of Heavy-Duty Servo Press. Appl. Sci. 2026, 16, 847. https://doi.org/10.3390/app16020847

AMA Style

Li J, Ma S, Liu B, Liu T, Wang Z. Dynamics Parameter Calibration for Performance Enhancement of Heavy-Duty Servo Press. Applied Sciences. 2026; 16(2):847. https://doi.org/10.3390/app16020847

Chicago/Turabian Style

Li, Jian, Shuaiyi Ma, Bingqing Liu, Tao Liu, and Zhen Wang. 2026. "Dynamics Parameter Calibration for Performance Enhancement of Heavy-Duty Servo Press" Applied Sciences 16, no. 2: 847. https://doi.org/10.3390/app16020847

APA Style

Li, J., Ma, S., Liu, B., Liu, T., & Wang, Z. (2026). Dynamics Parameter Calibration for Performance Enhancement of Heavy-Duty Servo Press. Applied Sciences, 16(2), 847. https://doi.org/10.3390/app16020847

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop