Next Article in Journal
Evaluation of the Hydraulic, Physical, and Mechanical Properties of Pervious Concrete Using Iron Tailings as Coarse Aggregates
Previous Article in Journal
Glycan-Dependent and -Independent Dual Recognition between DC-SIGN and Type II Serine Protease MSPL/TMPRSS13 in Colorectal Cancer Cells
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

An Alternative Approach to Cataract Surgery Using BSS Temperature of 2.7 °C

1
Biomorf Department, University of Messina, 98126 Messina, Italy
2
Diapartimento di Patologia umana e dell’età evolutiva “Gaetano Barresi”, University of Messina, 98126 Messina, Italy
3
MIFT Department, University of Messina, 98124 Messina, Italy
4
IRCCS, Neurolesi Center, 98125 Messina, Italy
5
Department of Reggio Calabria, EnvironmentalProtection Agency of Calabria, Italy (ARPACal), Via Troncovito SNC, 89135 Reggio Calabria, Italy
6
Department of Veterinary Sciences, University of Messina, Polo Annunziata, 98166 Messina, Italy
*
Author to whom correspondence should be addressed.
Appl. Sci. 2020, 10(8), 2682; https://doi.org/10.3390/app10082682
Submission received: 28 January 2020 / Revised: 2 April 2020 / Accepted: 8 April 2020 / Published: 13 April 2020
(This article belongs to the Section Applied Physics General)

Abstract

The aim of this study is to evaluate the difference in the number of endothelial cells after cataract operations with phacoemulsification by using a balanced salt solution (BSS) at standard temperature (about 20 °C) and at 2.7 °C. Two groups, comprising 214 individuals in total, participated in this study; patients were operated on using BSS bottle at about 20 °C and 2.7 °C in the first and second groups, respectively. All operations were conducted by the same surgeon and in similar conditions. One month after the operations, endothelial cells in the two groups were checked. For patients in Group 2, an important reduction in the loss of endothelial cells was observed.
Keywords: cataract surgery; phacoemulsification; balanced salt solution; endothelial cells cataract surgery; phacoemulsification; balanced salt solution; endothelial cells
Graphical Abstract

Share and Cite

MDPI and ACS Style

Meduri, A.; Aragona, P.; Testagrossa, B.; Scolaro, S.; Gurgone, S.; Bonanno, L.; Caridi, F.; Acri, G. An Alternative Approach to Cataract Surgery Using BSS Temperature of 2.7 °C. Appl. Sci. 2020, 10, 2682. https://doi.org/10.3390/app10082682

AMA Style

Meduri A, Aragona P, Testagrossa B, Scolaro S, Gurgone S, Bonanno L, Caridi F, Acri G. An Alternative Approach to Cataract Surgery Using BSS Temperature of 2.7 °C. Applied Sciences. 2020; 10(8):2682. https://doi.org/10.3390/app10082682

Chicago/Turabian Style

Meduri, Alessandro, Pasquale Aragona, Barbara Testagrossa, Sergio Scolaro, Sergio Gurgone, Lilla Bonanno, Francesco Caridi, and Giuseppe Acri. 2020. "An Alternative Approach to Cataract Surgery Using BSS Temperature of 2.7 °C" Applied Sciences 10, no. 8: 2682. https://doi.org/10.3390/app10082682

APA Style

Meduri, A., Aragona, P., Testagrossa, B., Scolaro, S., Gurgone, S., Bonanno, L., Caridi, F., & Acri, G. (2020). An Alternative Approach to Cataract Surgery Using BSS Temperature of 2.7 °C. Applied Sciences, 10(8), 2682. https://doi.org/10.3390/app10082682

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.