Evaluation of the Thermal Comfort and Energy Demand in a Building with Rammed Earth Walls in Spain: Influence of the Use of In Situ Measured Thermal Conductivity and Estimated Values

by
Miguel Ángel Mellado Mascaraque
1,*,
Francisco Javier Castilla Pascual
1,*,
Víctor Pérez Andreu
1 and
Guillermo Adrián Gosalbo Guenot
2
1
Department of Civil and Building Engineering, MAEE Research Group, University of Castilla-La Mancha, 16071 Cuenca, Spain
2
Ooko Industria Arquitectura S.L.U., 28015 Madrid, Spain
*
Authors to whom correspondence should be addressed.
Buildings 2021, 11(12), 635; https://doi.org/10.3390/buildings11120635
Submission received: 12 November 2021 / Revised: 4 December 2021 / Accepted: 6 December 2021 / Published: 10 December 2021
(This article belongs to the Section Building Energy, Physics, Environment, and Systems)

Abstract

This paper describes the influence of thermal parameters—conductivity, transmittance, and thermal mass—in the estimation of comfort and energy demand of a building with rammed earth walls, and consequently, the compliance with standards. It is known that nominal design data does not match in situ measured values, especially in traditionally constructed buildings. We have therefore monitored a room in a building with rammed earth walls, designed a computerised model, and compared four different alternatives where we have changed the value for the thermal conductivity (in situ vs. estimated) and the consideration of thermal mass. When we then analyse the compliance with the Spanish energy saving code, using measured values would result in lower differences with the standards’ limits and even comply with the global thermal transmittance (K-value) requirement. This would mean a more realistic approach to the restoration of traditional buildings leading to the use of thinner and more suitable insulation and retrofitting systems, encouraging the use of rammed earth in new buildings, and therefore reducing the carbon footprint due to materials used in construction. Results show that the building model that uses in situ values and considers thermal mass (S1) is closer to reality when assessing thermal comfort. Finally, using nominal data would result in requiring 43% more energy in the selected winter period and 102% more energy in the selected summer period to keep the same comfort conditions as in the alternative where measured values are used.
Keywords: thermal conductivity; thermal transmittance; rammed earth; indoor monitoring; comfort; energy demand; building simulation; code compliance thermal conductivity; thermal transmittance; rammed earth; indoor monitoring; comfort; energy demand; building simulation; code compliance

Share and Cite

MDPI and ACS Style

Mellado Mascaraque, M.Á.; Castilla Pascual, F.J.; Pérez Andreu, V.; Gosalbo Guenot, G.A. Evaluation of the Thermal Comfort and Energy Demand in a Building with Rammed Earth Walls in Spain: Influence of the Use of In Situ Measured Thermal Conductivity and Estimated Values. Buildings 2021, 11, 635. https://doi.org/10.3390/buildings11120635

AMA Style

Mellado Mascaraque MÁ, Castilla Pascual FJ, Pérez Andreu V, Gosalbo Guenot GA. Evaluation of the Thermal Comfort and Energy Demand in a Building with Rammed Earth Walls in Spain: Influence of the Use of In Situ Measured Thermal Conductivity and Estimated Values. Buildings. 2021; 11(12):635. https://doi.org/10.3390/buildings11120635

Chicago/Turabian Style

Mellado Mascaraque, Miguel Ángel, Francisco Javier Castilla Pascual, Víctor Pérez Andreu, and Guillermo Adrián Gosalbo Guenot. 2021. "Evaluation of the Thermal Comfort and Energy Demand in a Building with Rammed Earth Walls in Spain: Influence of the Use of In Situ Measured Thermal Conductivity and Estimated Values" Buildings 11, no. 12: 635. https://doi.org/10.3390/buildings11120635

APA Style

Mellado Mascaraque, M. Á., Castilla Pascual, F. J., Pérez Andreu, V., & Gosalbo Guenot, G. A. (2021). Evaluation of the Thermal Comfort and Energy Demand in a Building with Rammed Earth Walls in Spain: Influence of the Use of In Situ Measured Thermal Conductivity and Estimated Values. Buildings, 11(12), 635. https://doi.org/10.3390/buildings11120635

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop