Next Article in Journal
Effects of the Wall Temperature on Rarefied Gas Flows and Heat Transfer in a Micro-Nozzle
Previous Article in Journal
Multi-Material Radial Phononic Crystals to Improve the Quality Factor of Piezoelectric MEMS Resonators
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Using a 3D Silicon Micro-Channel Device and Raman Spectroscopy for the Analysis of Whole Blood and Abnormal Blood

1
Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
2
Department of Physics, National Taiwan Normal University, Taipei 10611, Taiwan
3
Department of Medical Laboratory Science and Biotechnology, National Cheng Kung University, Tainan 70101, Taiwan
*
Authors to whom correspondence should be addressed.
Micromachines 2024, 15(1), 21; https://doi.org/10.3390/mi15010021
Submission received: 8 November 2023 / Revised: 23 November 2023 / Accepted: 19 December 2023 / Published: 22 December 2023

Abstract

Blood testing is a crucial application in the field of clinical studies for disease diagnosis and screening, biomarker discovery, organ function assessment, and the personalization of medication. Therefore, it is of the utmost importance to collect precise data in a short time. In this study, we utilized Raman spectroscopy to analyze blood samples for the extraction of comprehensive biological information, including the primary components and compositions present in the blood. Short-wavelength (532 nm green light) Raman scattering spectroscopy was applied for the analysis of the blood samples, plasma, and serum for detection of the biological characteristics in each sample type. Our results indicated that the whole blood had a high hemoglobin content, which suggests that hemoglobin is a major component of blood. The characteristic Raman peaks of hemoglobin were observed at 690, 989, 1015, 1182, 1233, 1315, and 1562–1649 cm−1. Analysis of the plasma and serum samples indicated the presence of β-carotene, which exhibited characteristic peaks at 1013, 1172, and 1526 cm−1. This novel 3D silicon micro-channel device technology holds immense potential in the field of medical blood testing. It can serve as the basis for the detection of various diseases and biomarkers, providing real-time data to help medical professionals and patients better understand their health conditions. Changes in biological data collected in this manner could potentially be used for clinical diagnosis.
Keywords: blood testing; biological information; hemoglobin; Raman spectroscopy; 3D silicon micro-channel device blood testing; biological information; hemoglobin; Raman spectroscopy; 3D silicon micro-channel device

Share and Cite

MDPI and ACS Style

Chiang, C.-C.; Huang, S.-J.; Immanuel, P.N.; Lan, J.-H.; Lo, F.-Y.; Young, K.-C. Using a 3D Silicon Micro-Channel Device and Raman Spectroscopy for the Analysis of Whole Blood and Abnormal Blood. Micromachines 2024, 15, 21. https://doi.org/10.3390/mi15010021

AMA Style

Chiang C-C, Huang S-J, Immanuel PN, Lan J-H, Lo F-Y, Young K-C. Using a 3D Silicon Micro-Channel Device and Raman Spectroscopy for the Analysis of Whole Blood and Abnormal Blood. Micromachines. 2024; 15(1):21. https://doi.org/10.3390/mi15010021

Chicago/Turabian Style

Chiang, Chao-Ching, Song-Jeng Huang, Philip Nathaniel Immanuel, Jun-Han Lan, Fang-Yuh Lo, and Kung-Chia Young. 2024. "Using a 3D Silicon Micro-Channel Device and Raman Spectroscopy for the Analysis of Whole Blood and Abnormal Blood" Micromachines 15, no. 1: 21. https://doi.org/10.3390/mi15010021

APA Style

Chiang, C.-C., Huang, S.-J., Immanuel, P. N., Lan, J.-H., Lo, F.-Y., & Young, K.-C. (2024). Using a 3D Silicon Micro-Channel Device and Raman Spectroscopy for the Analysis of Whole Blood and Abnormal Blood. Micromachines, 15(1), 21. https://doi.org/10.3390/mi15010021

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop