Next Article in Journal
Predicting WNV Circulation in Italy Using Earth Observation Data and Extreme Gradient Boosting Model
Next Article in Special Issue
Impact of Molecular Spectroscopy on Carbon Monoxide Abundances from TROPOMI
Previous Article in Journal
Recent Applications of Landsat 8/OLI and Sentinel-2/MSI for Land Use and Land Cover Mapping: A Systematic Review
Previous Article in Special Issue
Impact of Molecular Spectroscopy on Carbon Monoxide Abundances from SCIAMACHY
Open AccessArticle

Retrieval and Validation of XCO2 from TanSat Target Mode Observations in Beijing

1
State Key Laboratory of Resources and Environmental Information System, Institute of Geographical Sciences and Natural Resources Research, Chinese Academy of Sciences, Beijing 100101, China
2
College of Resources and Environment, University of Chinese Academy of Sciences, Beijing 100049, China
3
National Satellite Meteorological Center, China Meteorological Administration, Beijing 100081, China
4
Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China
5
Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100190, China
*
Author to whom correspondence should be addressed.
Remote Sens. 2020, 12(18), 3063; https://doi.org/10.3390/rs12183063
Received: 28 August 2020 / Revised: 16 September 2020 / Accepted: 17 September 2020 / Published: 18 September 2020
Satellite observation is one of the main methods used to monitor the global distribution and variation of atmospheric carbon dioxide (CO2). Several CO2 monitoring satellites have been successfully launched, including Japan’s Greenhouse Gases Observing SATellite (GOSAT), the USA’s Orbiting Carbon Observatory-2 (OCO-2), and China’s Carbon Dioxide Observation Satellite Mission (TanSat). Satellite observation targeting the ground-based Fourier transform spectrometer (FTS) station is the most effective technique for validating satellite CO2 measurement precision. In this study, the coincident observations from TanSat and ground-based FTS were performed numerous times in Beijing under a clear sky. The column-averaged dry-air mole fraction of carbon dioxide (XCO2) obtained from TanSat was retrieved by the Department for Eco-Environmental Informatics (DEEI) of China’s State Key Laboratory of Resources and Environmental Information System based on a full physical model. The comparison and validation of the TanSat target mode observations revealed that the average of the XCO2 bias between TanSat retrievals and ground-based FTS measurements was 2.62 ppm, with a standard deviation (SD) of the mean difference of 1.41 ppm, which met the accuracy standard of 1% required by the mission tasks. With bias correction, the mean absolute error (MAE) improved to 1.11 ppm and the SD of the mean difference fell to 1.35 ppm. We compared simultaneous observations from GOSAT and OCO-2 Level 2 (L2) bias-corrected products within a ±1° latitude and longitude box centered at the ground-based FTS station in Beijing. The results indicated that measurements from GOSAT and OCO-2 were 1.8 ppm and 1.76 ppm higher than the FTS measurements on 20 June 2018, on which the daily observation bias of the TanSat XOC2 results was 1.87 ppm. These validation efforts have proven that TanSat can measure XCO2 effectively. In addition, the DEEI-retrieved XCO2 results agreed well with measurements from GOSAT, OCO-2, and the Beijing ground-based FTS. View Full-Text
Keywords: TanSat; target mode; XCO2 retrieval; validation; Beijing FTS TanSat; target mode; XCO2 retrieval; validation; Beijing FTS
Show Figures

Figure 1

MDPI and ACS Style

Bao, Z.; Zhang, X.; Yue, T.; Zhang, L.; Wang, Z.; Jiao, Y.; Bai, W.; Meng, X. Retrieval and Validation of XCO2 from TanSat Target Mode Observations in Beijing. Remote Sens. 2020, 12, 3063.

Show more citation formats Show less citations formats
Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Article Access Map by Country/Region

1
Search more from Scilit
 
Search
Back to TopTop