Article

Analysis of Airflow Organization in Buses Air-Conditioned by Direct Evaporative Coolers

1
School of Environmental & Municipal Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China
2
Lanzhou Jiaotong University Design & Research Institute Co., Ltd., Lanzhou 730070, China
*
Author to whom correspondence should be addressed.
Sustainability 2025, 17(4), 1647; https://doi.org/10.3390/su17041647
Submission received: 7 November 2024 / Revised: 18 January 2025 / Accepted: 12 February 2025 / Published: 17 February 2025

Abstract

Considering the energy-saving advantages of the direct evaporative cooler (DEC) compared to the traditional air conditioning system (TAC), this study aims to indicate its ability to improve the thermal comfort and the indoor air quality of the bus compared to the bus air-conditioned by the traditional compressor system. Taking a bus in Lanzhou as the object, the numerical model and method were first verified by an experimental method. Then, numerical analyses were simultaneously carried out in both bus models, which were air-conditioned by TAC and DEC, respectively. The results showed that the thermal comfort of the bus air-conditioned by DEC is more satisfactory, and the indoor air quality is better. Additionally, the bus air-conditioned by DEC achieves a 43.7% improvement in the temperature efficiency and a 31.3% improvement in the ventilation efficiency compared to the bus air-conditioned by TAC. The conclusion will provide valuable insights into the application of DEC in buses in dry regions.
Keywords: bus; direct evaporative cooling; air distribution; numerical simulation bus; direct evaporative cooling; air distribution; numerical simulation

Share and Cite

MDPI and ACS Style

Zhou, W.; Liu, M.; Duan, L. Analysis of Airflow Organization in Buses Air-Conditioned by Direct Evaporative Coolers. Sustainability 2025, 17, 1647. https://doi.org/10.3390/su17041647

AMA Style

Zhou W, Liu M, Duan L. Analysis of Airflow Organization in Buses Air-Conditioned by Direct Evaporative Coolers. Sustainability. 2025; 17(4):1647. https://doi.org/10.3390/su17041647

Chicago/Turabian Style

Zhou, Wenhe, Mengdie Liu, and Lin Duan. 2025. "Analysis of Airflow Organization in Buses Air-Conditioned by Direct Evaporative Coolers" Sustainability 17, no. 4: 1647. https://doi.org/10.3390/su17041647

APA Style

Zhou, W., Liu, M., & Duan, L. (2025). Analysis of Airflow Organization in Buses Air-Conditioned by Direct Evaporative Coolers. Sustainability, 17(4), 1647. https://doi.org/10.3390/su17041647

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop