Next Article in Journal
Does Direct Monetary Policy Affect the Supply of Bank Credit to Small and Medium-Sized Enterprises? An Analysis Based on Chinese Data
Previous Article in Journal
The Value of Integrity: Empowering SMEs with Ethical Marketing Communication
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Living Wall Plants Are Affected by and Affect Temperature: How to (not) Measure Plants’ Temperature in a Living Wall Experiment

by
Maren Stollberg
* and
Alexander von Birgelen
Department of Urban Horticulture and Plant Use, Hochschule Geisenheim University, 65366 Geisenheim, Germany
*
Author to whom correspondence should be addressed.
Sustainability 2023, 15(15), 11672; https://doi.org/10.3390/su151511672
Submission received: 8 June 2023 / Revised: 3 July 2023 / Accepted: 25 July 2023 / Published: 28 July 2023

Abstract

:
Living walls (LWs) are a climate change adaptation strategy for cities, as they have a cooling effect. Previous studies of the cooling effect of LWs were carried out in different climatic zones. These studies differed in their experimental design, or simulated data via models. Plants’ cooling capacity is explained by shading and transpiration, and depends on physical plant parameters, environmental factors, and system-related influences. A three-year-long trial was carried out between 2017 and 2019 at an experimental garden in Geisenheim, Germany. We chose a textile-based LW system with high water demand and plants from a wet/fresh habitat. We assumed that this would achieve high evaporative cooling. The experimental setup included four experimental walls, which were exposed to the north, south, east, and west, respectively. The plant choice was divided into three plant mix variants (Cascade, Ground cover, and Meadow) and a Control with no vegetation. We measured the temperature with sensors and a thermal imaging (IR) camera in different setups. The main results were that the measured vegetation temperature (TV) depends on air temperature (TA), measurement position, plant mix variant, and plant species. We could detect the cooling effect only at a small distance from the LW (microclimatic). Our methodological approaches should be continued in further studies.

1. Introduction

Living walls (LWs) are modern vertical greenery systems essential for increasing the city’s green space. They have the advantage that they can be used anywhere and bring about the well-known positive effects of urban greenery. These effects include, for example, cooling and improving air quality, and promoting biodiversity, aesthetics, psychological well-being, and energy-saving through building insulation [1,2,3,4,5].
Unlike a traditional ground-based system, LW is a new, wall-based system for the vertical greening of facades that does not require a ground connection [4,5]. This is particularly advantageous since a ground connection is often impossible in dense urban environments. If no soil connection is possible, the plants are supplied with water and nutrients directly on the wall [3,4,5]. There are several LW configurations that, in principle, allow adaptation to the building, environmental conditions, and goals of greening [3].
The “vertical green industry” highlighted the cooling potential of LWs in the urban environment in the context of climate change consequences and the urban heat island effect.
Further, researchers have suggested the use of LWs to increase urban greenery and cool the ambient temperature [1,6]. Studies have discussed the cooling potential of LWs and the building insulation that LWs can provide. This article is about the cooling effect of LW and its method to be determined, which can be measured in vegetation or in front of the LW. Our experiment took place in an experimental setup. For the future, our experiences and results could be interesting to quantify the cooling effect of LW in an urban space, i.e., an urban environment or a street space.
While some studies describe the cooling potential of vertical greenery, it is not yet clear how an LW needs to be configured to achieve a great cooling effect.
Previous studies on the cooling effect of ground-based facade greening show the following values: 2–20 °C [7], up to 30 °C [8], 1.7 °C [9], and 2 °C (depending on exposure) [10]. Previous studies on TA reductions due to LWs were summarized by Besir and Cuce [6] and Brune et al. [11] and included, for example, 4.5 °C [12], 1.9–8.3 °C [13], 12–20 °C [14], 1–10.94 °C [15], and 5 °C [16]. A decrease in wall surface temperature between 3.33 °C and 11.58 °C was found in different studies and summarized in [1].
These values were collected in different climates, systems, and experimental designs. While it is clear that climate influences cooling potential [6], it is often not specified which plants were planted in LWs [13,14,17,18]. In the study by Cameron et al. [19], the reduction in TA was described for individual plant species: Stachys byzantina, 7.6 °C; Hedera helix, 7.3 °C; Lonicera ‘Gold Flame’, 5.5 °C; Fuchsia ‘Lady Boothby’, 5.5 °C; Jasminum officinale ‘Clotted Cream’, 4.3 °C; and Prunus laurocerasus, 6.3 °C. In addition, the cooling effect depends on the plants’ vitality and the degree of cover [13,18]. It is also crucial at what distance from the vegetation the temperature is measured [15,17].
In a study by Žuvela-Aloise et al. [20], several simulations were performed on the cooling effect due to green and blue infrastructure. It became clear that the transpiration cooling effect depends on many location-dependent factors (such as the built environment or wind characteristics). This dependency confirmed the findings from other studies (summarized in [6,11,20]).
Alexandri and Jones [21] simulated the temperature in greened/ungreened streets using the solar radiation, TA, relative humidity, and wind speed (min, max, average) of nine different cities by measuring the hydrothermal properties of the following materials: concrete, soil, asphalt, and vegetation. Depending on these initial values, a temperature reduction due to facades and green roofs was always observed in the model. In the course of the day, the highest temperature reduction was observed between 2 and 8 p.m. [21]. Depending on the city, they observed a maximum temperature reduction of 2.5 to 5 °C for facade greening [21].
Different factors of a vertical greenery system result in a lower environmental temperature. Evapotranspiration is crucial for the cooling effect. We distinguish between transpiration and evaporation as the following: transpiration means the departure of water from the stomata of the plant leaves during photosynthesis and evaporation describes the process of water departing the substrate to enter the environment.
We can differentiate three factors that influence the cooling effect:
(1) Plants, plant shading, and transpiration [6,22]. These factors are influenced by solar radiation and, thus, exposure [22].
Plant selection and vitality are critical to evapotranspiration performance [6,22,23]. Plants should be well-irrigated when their transpiration only functions if they have no (dry) stress. Only then are the stomata fully open, which requires transpiration [22]. Plants with a high transpiration rate cool the temperature more than others [6]. However, the LW practice uses established and drought stress-resistant species (e.g., Heuchera) or creates systems that are as low-maintenance, robust, and low-water intensive as possible. These species mostly have a low transpiration rate.
Furthermore, the leaf canopy characteristic is important; plants’ biomass, plant stage development, leaf thickness, leaf color (albedo), and leaf area also affect their cooling properties [6,22,24].
There are few published scientific results on plants in LWs [2,4,25]. Previous studies have been from different climates and have examined only a few LW systems and plant species.
(2) Technical configuration affects cooling performance. In addition to the plant, the substrate surface produces evaporation cooling, i.e., the substrate amount and type have an influence [6]. The size of the rhizosphere, moisture of the substrate, and, thus, the irrigation (specifically, the amount and frequency of watering) are essential to a plant’s cooling performance [24].
(3) The environment, including local and microclimate, exposure, wind speed, humidity, solar radiation, and temperature, influences the cooling effect of plants [6,24]. The dependency of many site factors is summarized in [6,11,20].
Based on the current state of knowledge, the statements on temperature-reducing effects do not allow any differentiated conclusions to be attributed to the different characteristics of an LW, e.g., plant selection, irrigation, or environment. Research is needed to quantify the air cooling of LWs [5,7,26]. In addition, there is a lack of direct translation of results from experimental studies to urban environments.
As Koch [22] stated, to describe the energy-saving effect of LWs, most previous studies focused on the thermal effect of an LW on the building. In contrast, only a few studies examined the impact on the local climate and microclimate [22] or the temperature in the vegetation stock.
The main aim of our study, started in 2017, was to describe how we could measure temperature in LWs, to determine which factors influence temperature and its measurement, what conditions plants have to deal with in an LW, and which cooling effect an LW could provide.

2. Materials and Methods

We have already published parts of this research project in various ways, including two articles with practical advice in German [27,28], an overview of the visual impression of all planting variants [29], and detailed elaborations about both the seeding variants [30] and the planting variants [31].
In this paper, we would like to present how we measured the temperature in our LW experiment.

2.1. Experimental Setup

At the Hochschule Geisenheim University, in Geisenheim (49°59′11.161″ N 7°58′0.099″ E.), we built experimental walls exposed to the north, south, east, and west, respectively (Figure 1). We tested a new LW system at different expositions from 2017 to 2019. The LW system (a vegetation mat) consisted of a polyester–textile material (Sächsisches Textilforschungsinstitut e.V., Chemnitz, Germany) and had no substratum [28]. An automatically closed irrigation system was installed for the watering and nutrition of the plants. We tested different plant species and created three different plant categories—”Ground cover”, “Cascade”, and “Meadow” (here, we placed seeds in the substrate)—and used a control without planting. Spontaneous vegetation (from random weeds, mostly moss and plants from the other variants) established itself in the Control and the Cascade areas. The plant variants were repeated four times.

2.2. Temperature Measurement

Between 2017 and 2019, we carried out various temperature measurements (Table 1). We documented the TA (°C), radiation (W/m2), humidity (%), and precipitation (mm) near our experimental walls with a weather station (field) (Figure 1). The climate of the experimental location is classified as a temperate oceanic climate. We measured the temperature (°C) at different mat positions, plants, exposures, seasons, and in front of or behind the LW. Therefore, measurement instruments were arranged in different experimental setups (Table 1).
We used radiation unprotected sensors: plastic-sheathed 10k thermistor, (SKTS 200/U, UP Umweltanalytische Produkte GmbH Bockradener Strasse 52b, 49477 Ibbenbüren, Germany) and metallic sleeve Thermokon cable temperature sensor T14, (Elektro- und Automatisierungsanlagen Pierre Ambrozy, Schmiedestrasse 14, 06466 Gatersleben, Germany) for temperature measurement. We created radiation protection (open plant pot covered with aluminum foil (alu pot)) for the temperature sensors (Table 1, measurement: 6).
The temperature sensors logged the data every 5 min. We calculated the mean of 15 min (n = 3) and adapted the data on the weather data, which were recorded every 15 min.
Radiation-protected TA and humidity were determined via psychrometer (KE-PTFF-8024, NTC sensor, Elektro- und Automatisierungsanlagen Pierre Ambrozy, Schmiedestrasse 14, 06466 Gatersleben, Germany).
For thermal imaging, we used an InfRec R500EX-Pro IR camera from Nippon Avionics Co. Ltd. with the InfReC Analyzer NS9500 software (Eichleite 13b, 82031 Grünwald München, Germany).
We installed the following weather stations at the experimental walls (east and west): Compact WSC11 (Adolf Thies GmbH & Co. KG, Hauptstrasse 76, 37083 Göttingen, Germany). These data were compared to the data of the field weather station (Figure 1).

3. Results and Brief Information Regarding the Setup

3.1. First Try: Temperature Measurement

In our first measurement, from October 2017 to February 2018, we aimed to determine if there were differences between the planting variants and positions in, behind, and in front of the mat.
Our findings revealed that the Control showed the highest differences between positions, whereas Cascade and Meadow exhibited less variation between positions (Figure 2A–C). For Ground cover, we observed similar temperatures between the middle and behind positions, while the front position had either lower or higher temperatures, depending on the time of day (Figure 2D).
Regarding temperature trends over time, we found that the temperature behind and in the middle of the plants remained similar for Control, Meadow, and Cascade. The temperature behind the plants was consistently lower than the middle temperature. Ground cover showed similar temperatures for both middle and behind positions.
Our results showed that the front temperature during the daytime was higher than the middle and behind temperatures for Control and Cascade. During the nighttime, the Control had lower front temperatures than at the behind and middle positions. For Ground cover, the front temperature was either higher or lower than the middle and behind temperatures.
Our analysis of the overall temperature patterns found that the mean values for all positions and plant variants were similar (Figure 2F). The maximum temperature recorded was around 20–22 °C for all variants, except for the Control, which showed the highest maximum temperature at 24.8 °C. Cascade had a maximum temperature of 21.4 °C, while both Ground cover and Meadow had a maximum temperature of around 17 °C. We also observed a minimum temperature of −4 to −6 °C for all variants in the front and middle positions, except for Ground cover, which had a minimum temperature of −1 °C in the middle position. The temperature behind the mat was consistent across all variants, with a minimum temperature of around −2 °C.

3.2. Advanced Setup to Measure Differences between the Variants and Positions

Based on the findings from the first experiment, the experimental setup was optimized. We now wanted to compare data from a period with strongly increasing (April 2018) and decreasing temperatures (February 2019) (Figure 3). Furthermore, the research question of whether there are differences between the variants and the measurement positions was addressed.
We found few inter-variant differences and partial differences between the individual positions. We observed the highest diurnal temperature variations in the Control, especially within the mat (Figure 3).
In February, we observed the lowest temperatures inside the mat (1-into) for the Control, Seeding, and Ground cover, which may have been due to frost. For Ground cover and the Control, the temperature measurements into (1) and back (2) showed similar values. For Cascade, we measured the same temperature at all positions, except for a drastic temperature increase measured at the beginning of the day. For Seeding, the temperatures were about the same at all positions. The front temperature (3) was partly higher.
In April, higher temperatures were measured overall. Here, a difference between the Control and the planting variants was noticeable. For Control, we documented similar values for 1-into and 3-front. For all plant variants, we analyzed an extreme temperature increase in the inner part of the vegetation layer (1-into) at the beginning of the day (from 6 to 9 a.m.). In April, we observed higher Tdiffs between the positions (front, back, into). In addition, we found the highest temperature at the front (3) most of the time. This position showed the highest diurnal differences.

3.3. Influence of the Amount of Biomass

We wanted to know if there was an influence on the temperature due to the amount of biomass (Table 2 and Supplementary File S1). Therefore, we measured the temperature before and after cutting the Meadow and Control in July and August 2018. Data from before and after the cut were compared within temperature categories selected based on similar TA (Figure 4 and Figure 5). In addition to the temperature, we measured the height, coverage, and biomass after the cut.
We observed similar results in all temperature categories before and after the cut (Figure 4).
The temperature was significantly higher in the Control compared to Meadow, but fewer differences were measured between the time before and after cutting. In category 2 (20–21 °C), there were the most significant differences between before and after cutting for Meadow and the Control (Figure 4E).
Overall, we can determine that the TA was sometimes higher and sometimes lower compared to the TV (Figure 5). We observed differences between categories and measurement points. Except for the days when the mean TA was between 17 and 18 °C (category 1), there were fewer differences between the variants.
In category 2, the air, Control, and Meadow temperatures were similar. In category 3, the Control temperature was significantly higher (up to 10 °C).
In categories 2 and 3, a cooling effect of vegetation was observed before cutting at daytime. At night, a higher temperature for the Control and vegetation was observed compared to the TA.
After the cut, a lower difference or no difference was observed between the TA and TV for category 3. Before cutting, the Control temperature was significantly higher than all other temperatures measured, category 2, and category 3.

3.4. Temperature of the Single Plants

After we obtained information about the Meadow variant, we wanted to learn more about the single plants in the Cascade and Ground cover variant. To measure all single plants, we used the period between September 2018 and January 2019. We carried out the measurement in the vegetation and below into the mat. As we did not have enough sensors for all the plants, we changed the sensors after a time. Nevertheless, to achieve comparability between all species, we categorized the TA (Figure A1 and Figure A2 and Supplementary Files S2–S5) and compared the different plants only within one temperature category. In addition, we calculated the difference between air and TV.
We observed Tdiffs among plant species, measurement points (vegetation and mat), and expositions. Our results showed significant differences in temperature data between the factors mentioned above (Supplementary File S5). We observed that the TV was generally in a similar range as the TA and temperature categories. Moreover, the TV increased with rising TA (boxplots). We found a wide distribution of temperature values throughout the day for air and vegetation (Table 3). The TV exhibited a larger range of temperature values compared to TA (absolute difference between the minimum and maximum (K)). The range of values for the TV was between 9.8 K and 53.1 K, while that of the TA was between 6.7 K and 35.4 K. This indicated a more dynamic and larger temperature range for the TV.
Our analysis of Tdiff_V-A revealed that the TV was higher than the TA (Figure 6). On average, across all investigated plant species, the TV was 0.6 K higher than the TA and, at maximum, 3.6 K higher. This effect was observed mainly during the day and rarely during the night, when the temperature of the vegetation was rarely cooler compared to the TA. We also observed significant differences between expositions and plant species (Supplementary File S5).
Plant species from the Ground cover planting variant (Ajuga tenorii, Lysimachia nummularia, Waldsteinia ternata, Figure 6) exhibited the lowest temperatures at the east- and west-facing walls. At the north- and south-facing walls, the vegetation had higher temperatures. Among the Cascade variant plants (plant species: Asplenium scolopendrium, Carex doliostachya, and Hemerocallis X cultorum, Figure 6), we measured the highest TV at the east-facing wall.

3.5. Differences within One Mat

We installed temperature sensors in a mat in a grid or profile to detect whether there was a different temperature distribution within a mat. The sensors were plugged into the mat. The available sensors were plugged into only one mat to measure as many positions as possible. This measurement was carried out between December 2018 and February 2019.
The grid measurement showed higher mat temperatures in the upper part of the mat, especially for Cascade (Supplementary File S6). The first row of the mat (left) was cooler than the TA and the rest of the mat in comparison. The second and third rows showed higher temperatures compared to the air (Figure 7A).
In the profile measurement, there were fewer differences between Ground cover and Cascade positions. For Control and Meadow, we observed a mean difference of around 2 K between the top and middle/below (Figure 7(B1,B3)). The temperature in the mat was higher in the daytime for all variants and positions (Figure 7(B4)).

3.6. Alu Pot Radiation Protection

We built a new setup to place the sensors in front of the experimental wall. For our previous measurement, we used radiation-unprotected temperature sensors, and we had only three psychrometers that could measure the temperature without the influence of radiation. In the earlier setups, we tried to protect the sensors with vegetation and took the radiation error into account. Since we wanted more measuring points, we tried to create radiation protection for the temperature sensors. Thus, we tried different materials and compared the temperature at the same measurement point. The psychrometers showed lower temperature values than all other protection variants (Figure 8). The highest differences between the psychrometer and the temperature sensors was reached at “no protection” and the closed white plant pot. In the east, we also observed higher temperatures for the protected sensors compared to the weather station near the wall and the psychrometer. From this experience, we decided to use protection. Open plant pots were covered with aluminum foil, and this was designated as “alu pot”.

3.7. Temperature at a Fixed Distance from the Wall

We designed a new setup, based on our previous experiences, to ensure consistent sensor placement at fixed distances of 30 cm and 150 cm in front of the experimental wall. For the installation, wooden laths were attached to the experimental wall. Link chains were hung down from the laths, and sensors were attached to the chains. To protect the sensors, we employed an alu pot radiation shield. Our measurements were conducted from April to July 2019, encompassing various exposures and planting variants.
Significant differences were observed for Tdiff (distance–air) between the 30 cm and 150 cm temperature distances across all variants and exposures, except for the western exposure and Ground cover (Figure 9A and Figure A3, Figure A4, Figure A5, and Figure A6). Additionally, significant differences were observed between the different exposures and variants (Supplementary Files S7 and S8).
Overview boxplots were generated to analyze the data. Positive values indicated that the temperature at the measurement point was higher than the TA, while negative values indicated cooling, i.e., lower temperatures than the TA. For both the 30 cm and 150 cm distances, the temperature fluctuated above and below the TA within a similar range. Thus, the hypothesized cooling effect was not observed. Further, the Control group did not differ significantly from the plant variants.
The temperature range for Tdiff (distance–air) was comparable for both distances. However, the 150 cm distance range tended to be skewed toward positive values, indicating that temperatures at 150 cm were often higher than the TA compared to the 30 cm distance, where it was cooler (Figure 9B). In summary, average values were calculated (Figure 9C). A cooling effect was observed for Meadow at the 30 cm distance. However, at 150 cm, temperatures were consistently 2 K higher for the northern and eastern exposures, while no differences were observed for other exposures.
No differences were observed at 30 cm for the south and west for Cascade, while a 1–1.5 K higher temperature was recorded for the north and east. At 150 cm, temperatures were consistently higher for the north and east (2.3 K).
Ground cover and Control variants showed fewer differences at the 30 cm distance, but a 2 K higher temperature was observed at 150 cm. At a distance of 150 cm, no significant difference was observed between planting variants and the Control group (Supplementary File S7).
Notably, temperatures were consistently higher for the northern and eastern exposures at 150 cm, even for the Control group. Overall, a cooling effect was only observed for the Meadow variant at the 30 cm distance.
Example days were plotted to illustrate daily temperature variations for different variants and exposures (Figure A3, Figure A4 and Figure A5). In general, it is impossible to draw a clear conclusion from considering all variants and exposures.

3.8. IR Camera vs. Temperature Sensors

We built a new setup to place the sensors at a fixed distance. We extended the setup shown in Figure 7 and installed temperature sensors at a distance of 90 cm. In addition to the measurement with the temperature sensors, we made measurements with the IR camera from a distance of 6 m (Figure 10A and Figure A7). We collected temperature data with temperature sensors 30, 90, and 150 cm in front of the experimental wall. For the installation, wooden laths were attached to the experimental wall. Link chains were hung from the laths, and sensors were attached to the chains. The sensors were covered with the alu pot radiation shield.
We observed significant Tdiffs in front of Cascade at distances of 30 cm and 90 cm compared to Control and Ground cover. Both distances exhibited lower temperatures. However, there were no significant differences between the variants at a distance of 150 cm (Figure 10B). Regarding Cascade, the temperature also increased significantly as the distance increased. For the Ground cover and Control variants, we found that the temperature range at the 30 cm distance showed significantly lower temperatures compared to distances of 90 cm and 150 cm (Figure 10B).
There were minimal differences between the variants and distances when considering the mean values. However, Cascade showed lower maximum temperatures at 30 cm and 90 cm distances than Ground cover and Control (Figure 10C).
All variants exhibited significantly higher temperatures compared to the ambient TA. In the daily cycle, we observed that Cascade and Ground cover 1 were either slightly below or equal to the white wall temperature (wall without vegetation/mat). The Control and Ground cover 2 (both hanging on the second row against the wall) recorded temperatures above the wall temperature. Notably, the two repetitions of the Ground cover variant showed distinct differences.
There seemed to be little variation in temperatures among the different distances in the diurnal cycle. For Cascade, it was evident that the temperature at the 30 cm distance was significantly lower than at other distances. In Ground cover 2 and Control, temperatures at the 90 cm distance were occasionally higher than at 30 cm and 150 cm from the wall. These instances often exhibited spikes above 35 °C, followed by a quick drop (Figure A7).
The IR images vividly depict the surface temperature fluctuations throughout the day (Supplementary File S9). Within an hour, the surface temperature rose from 24 °C to 39 °C, then decreased to 24 °C within 2 h (Figure 8B, 18 June 2019 9 a.m. to 1 p.m., top left). Smaller temperature variation of the surface seems normal during the diurnal cycle (e.g., 19 June 2019, 2:40 p.m. to 3:16 p.m.). Irrigation and solar radiation played a role in these fluctuations. The measured drainage ranged between 4 and 6 L for all variants. Approximately 14 L were applied for irrigation, meaning that after each irrigation event (once per hour) [30], around 8 L of water was absorbed.
Differences between the planting variants are evident on the 19th of June 2019 at 11:36 a.m. and 1:52 p.m. The Heuchera surface (Cascade, reddish color) and Achillea (Ground cover 2) appeared to warm at 2 to 4 K. The Control, covered with moss, also showed a larger area with an approximately 5 K higher surface temperature at 11:36 a.m. and cooled down again within 3 h (Figure 11). Even within a single variant, significant differences in surface temperatures were observed.
The IR pictures and temperature sensors both demonstrated fluctuating temperature values. While the surface temperatures exhibited a drastic increase at 11:07 a.m. on the 18th of June 2019, this observation was not reflected in the diurnal cycle diagrams (Figure A7). However, the temperature sensors consistently indicated higher temperatures at a distance of 30 cm compared to surface temperatures. While the temperature sensor data suggested that Control and Ground cover 2 had higher temperatures, this cannot be observed in the IR images.

3.9. Climate Data at the Experimental Wall

To determine the vertical radiation on the wall, we hung PAR meters vertically, which are typically used horizontally, on the walls. We compared them with radiation data from the field weather station. We observed significantly lower PAR values on the wall (Figure A10).
We installed weather stations in the center of both the western and the eastern walls. We measured from February to June 2019. We compared these data with the data from the weather station nearby (Figure 12, Figure A8 and Figure A9 and Supplementary File S10). The data from this field weather station were used to calculate the Tdiffs in previous experiments.
The temperature values at all three weather stations were similar (Figure 12A). Differences were observed when examining the total radiation (Figure 12B). The field weather station recorded a higher total radiation than both walls’ weather stations. There was only a difference between the eastern and western weather stations in June, but it was technically related (Figure 12C). By referring to individual days throughout the day, it becomes evident that radiation is higher in the morning in the east and higher in the west from midday onward, compared to the field.
The field weather station partially recorded a higher humidity (%) and wind speed (m/s). For precipitation (mm), all weather stations recorded values within the same range. The wind direction (°) differed between the east and west.

4. Discussion

Only a few experiments have investigated the ambient temperature effects of plants in LWs. These studies do not apply standardized measurement methods and (mostly) do not include replications of the variants or measurements [2,11]. Therefore, a comparison of previous data is difficult; yet, these data are used in models/simulations [11]. There are also models/simulations that run without validation, using data from experiments [2]. In other cases, the exact procedure was insufficiently explained, so a replication of the study is impossible [2]. Hunter et al. [2] demanded that the scientific experimental design be improved, a sufficient number of replicates be built-in, and modeling studies be validated with data from experiments [2].
Therefore, we devised different experimental setups in which we measured the temperature of plants in LWs in different time periods and with different sensors. As there are fewer studies about temperature measurement, we attempted different methodological approaches. With these approaches, we wanted to identify influencing factors, the climatic condition of plants at walls, and if the LW system has a cooling effect. We wanted to know: how can temperature be measured inside and in front of LWs? Therefore, we used temperature categories for the formation of Tdiffs, soil temperature sensors, and an IR camera.

4.1. Temperature Categories

We only had a small number of temperature sensors available (due to financial bottlenecks, we had to resort to the sensors) and could only measure a certain number of plants and positions. To compare all plants with each other, we used the approach of forming temperature categories. This means that days with a similar TA were searched for and formed a category. The results of the temperature measurements in the vegetation were compared only within one temperature category. In addition, we calculated the Tdiff (Tdiff) from the TV and the TA. We have aimed to compare the temperature data of the different species measured at different time intervals. However, we found that the influence of the TA was substantial, so it was impossible to compare the data outside the temperature categories. A comparison of data within a temperature category yielded successful results, such as in the experiment to study the influence of biomass on temperature. We could not confirm this finding in another experiment measuring the temperature of individual plants. Compared to the TA, the Ground cover plant species on the eastern and western exposures had the lowest temperature.
In contrast, the vegetation on the northern and southern exposures had higher temperatures in a comparable temperature category. However, these results cannot be effectively compared in a category or with Tdiffs due to considerable differences in measurement periods. Therefore, we concluded that the temperature categories and calculation of Tdiffs based on TA are useful when seasonal variations are not too far apart.

4.2. The Use of Soil Temperature Sensors and Alu Pot Covers

We conducted experiments to assess the usefulness of soil temperature sensors in measuring temperature and to determine if they are affected by radiation errors that can be minimized by using alu pot covers. Our experiments showed that vegetation or surface temperature exhibited a wider range of temperature values compared to TA. This difference could be attributed to the variations in measurement methods between TA and vegetation sensors. We devised a radiation protection method—using pots covered with aluminum foil (alu pot)—to mitigate radiation errors. It is worth noting that the psychrometer also recorded lower temperature values compared to the alu pots. This discrepancy may be due to a lack of air exchange caused by the protective covering or the covering material’s heat absorption and retention properties.
Nevertheless, despite these factors, we decided to use the alu pots as a means of protection, as they yielded lower temperature values than the sensors without any protection. Acknowledging that the measured results still carry a radiation error is important. We strongly recommend using appropriate TA sensors to minimize such errors, particularly those placed at a distance from LWs. We had to use these sensors due to financial constraints.

4.3. IR Camera

Compared to the temperature sensors, we wanted to explore the results of an IR camera. In contrast to the sensors, the IR images exhibited a much stronger variation or dynamic range of temperature values within minutes. Additionally, the images allowed for a more detailed differentiation of surface temperatures among individual plants and variants. Overall, the IR images showed lower temperatures compared to those recorded by the sensors. It is also noticeable that the cooling effect of irrigation was visible in the surface temperature when watering had occurred, which was not evident in the sensor readings.

4.4. Factors Which Influence the Vegetation Temperature

We aimed to identify influencing factors on the TV at the LW. We found that temperature data differed because of: (1) climatic conditions, (2) exposure, (3) measurement positions, and (4) plant species, planting variant, and biomass.

4.4.1. Climatic Conditions

We argue that climatic conditions, particularly TA, and external environmental factors have a greater influence on temperature and potential cooling effects in front of or within the vegetation of the LW rather than the vegetation itself. In all our experimental setups, we observed that TA determined the temperature of the vegetation or its immediate surroundings. It was evident that the measured temperatures closely followed the pattern of the TA. For instance, we noticed a significant temperature increase within the inner part of the vegetation layer at the beginning of the day on the eastern side, where solar radiation is high. We could only compare temperatures within the temperature categories, since even the calculated Tdiffs were strongly influenced by the climatic conditions. It was apparent that the cooling effect was minimal at cooler TAs (<22 °C) and only measurable at higher external temperatures (above approximately 22 °C). Gräf et al. [24] also demonstrated the dependence of TV on TA. They highlighted that Tdiffs were greater on warm days compared to cold ones.
Furthermore, we rarely observed differences among plant variants compared to the control group. This finding suggests that environmental conditions, most likely temperature, impact TV the most.
When using IR cameras, we observed different temperature values, indicating that plants have a microclimatic effect that does not significantly influence the broader environment. In turn, the TA in the surroundings has the greatest impact. Overall, evaporative cooling might not be as pronounced as initially hypothesized. However, numerous studies on insulation effects provide evidence of a temperature effect, suggesting that shading and protection from direct solar radiation are the primary temperature-modulating factors associated with vegetation [32].

4.4.2. Exposure

There were minor differences between the exposures. The most noticeable difference was that a higher temperature at a distance of 150 cm from north- and east-facing walls was measured compared to that of the other exposures.
Our setups and the chosen measurement period in which we compared the exposures could only be compared in limited time units and not simultaneously, because we had too few sensors. In future experiments, all experimental walls should be compared at the same time and over a longer time.

4.4.3. Measurement Position

There were clear differences between the different distances and positions. There were partial differences between the individual positions on a mat. Compared to the TA, the mat in the first row (left) was found to be cooler than the TA and the rest of the mat. Conversely, the second and third rows showed higher temperatures than the air. Possibly, these positions were better protected from the wind. It is rather difficult to rule out that the moisture of the mats was lower here, as the mats were overwatered.
One significant finding was the Tdiff (Tdiff) between the distances of 30 cm and 150 cm from the air across all variations and exposures, except for the western exposure with Ground cover. It was observed that temperatures at 150 cm were often significantly higher than the TA. In contrast, the temperature was cooler at distances of 30 cm and 90 cm compared to the distance temperature of 150 cm.
The position behind the LW exhibited fewer significant temperature changes, depending on the daily cycle. Additionally, variations were observed in the positions based on the season and plant variant. In most cases, the front position tended to be warmer, while at night, the back position exhibited higher temperatures, indicating a buffering effect. A similar result was also seen in other studies [15,17].

4.4.4. Plant Species, Planting Variant, and Biomass

We observed differences in temperature depending on plant species, planting variant, and biomass. On average, all plant variants showed similar reactions. However, there were partial differences observed between plant variants and species. Examining individual plants revealed significant variations in terms of minimum and maximum temperatures. It is important to note that measurements were taken at different time points, limiting their comparability. The measured TV should always be considered in relation to the TA. Based on this, there is a likelihood that the choice of plant species influences the temperature effect.
The amount of biomass in LWs has an impact on temperature. This was evident in the experiment where we observed cooler temperatures in Meadow before the cut during the daytime compared to after the cut. We assume that the experimental wall and the mat/vegetation stored heat at night, as we measured higher temperatures during the nighttime. Plants contribute to a balanced microclimate, resulting in fewer extreme temperatures on the wall.
We found few differences between plant variants, and the Control group exhibited the highest diurnal temperature variations. Overall, our results suggest that temperature variations depend on the plant variant. However, we also observed that repeating the same variant yielded different temperatures, possibly due to the position on the wall (upper or lower row).
Partially, the Control group had higher temperatures during the day than the plant variants. The colour of the mat (black) also certainly played a role in the temperature development. However, our Control group had moss growth, which had similar effects. Thermographic images showed that the plant variants’ temperatures were lower than the moss, although not consistently. A study by Gräf et al. [24] found that stressed plants did not demonstrate a different leaf temperature compared to non-stressed plants (range maximum 1 K). They observed a wider span only for Heuchera.
Our experiment showed that temperatures became similar across all variants when irrigation was applied. Since the temperature reduction occurred in both vegetation and the Control group, we believe that temperature depends more on irrigation rather than the amount of biomass. Irrigation is essential to achieve a cooling effect [24].
Studies on plant suitability are rare. One study by Cameron et al. [19] examined different plants in a facade greening system (pots in front of a wall) under controlled conditions in a greenhouse. They observed a maximum temperature decrease of 7.6 °C and a minimum of 4.3 °C. Other studies did not differ in the temperature measurement between the plant species.
We could only measure a small number of plant species or variants simultaneously. Our results do not provide a conclusive explanation for the different temperatures observed. Further research is needed to investigate the temperature effects of individual plant species and the impact of irrigation and substrate selection.

4.5. Climatic Conditions for Plants

Our next aim was to describe the climatic conditions for plants, which refers to the experimental environment. It is known that plants on facades are exposed to extreme conditions [25], and that plants do not evaporate and cool temperature if they are stressed because of extreme conditions [6]. Therefore, knowing more about the facade conditions for plants in LWs is important.
While measuring the TV, we observed a broader range of temperature values than the TA. This suggests that plants in the LW (presumably referring to the study area) are exposed to significantly different climatic conditions than what “normal” weather stations measure. As a result, we conducted measurements directly at the experimental walls using weather stations. We found similar climate conditions for the walls compared to the field. It is important to note that the measurement period was limited to February through June 2019, focusing on the western and eastern exposures. Therefore, we cannot conclude that the regular weather data are sufficient to derive wall conditions.
One crucial factor in determining the climatic conditions is the radiation incident on the wall. Typically, radiation is measured horizontally. Even the wall weather stations measured radiation horizontally. However, the plants in our LWs were exposed to vertical radiation. Therefore, we attempted to measure the radiation vertically, but it was unsuccessful. Furthermore, we assume these specific parameters significantly differ from the normal horizontal planting conditions.
In general, it should be noted that our experimental walls are not situated in an urban environment. They are located in research areas where several plants and trees are present. There are plastic panels in front of the experimental walls, and in front of the southern wall is mypex foil, which heats up. However, there are numerous plants in close proximity, and the weather station where the TA was measured is directly situated in a viticulture research field. Consequently, the results must be interpreted in light of these circumstances.

4.6. Cooling Effect of Our Living Wall

The closing objective of our experiment was to describe the cooling effect.
While we discovered that TV generally follows the TA and depends on it, we also observed a wider range of temperature values in the vegetation compared to the TA. This temperature range difference could be attributed to variations in the measurement methods for TA and the vegetation sensors.
We partially observed a cooling effect within the vegetation and that the plant variants exhibited lower maximum temperatures than the Control group. However, this varied depending on the plant variant, plant species, time of day, and season. Generally, we can conclude that vegetation acts as a buffer, resulting in warmer temperatures behind the vegetation during the night compared to areas without vegetation.
Measurements taken at distances of 30 cm and 150 cm from the vegetation showed temperature fluctuations both above and below the TA, respectively. Therefore, the hypothesized cooling effect was not observed. Furthermore, no significant differences existed between the Control group and the plant variants. Perhaps our LW area was not large enough to measurably affect the surroundings.
Our findings did not achieve the temperature cooling effects described in previous studies [6]. Generally, we could only detect the cooling effect on a microclimatic scale. We observed several differences between the variants, exposures, plant species, and distances from the wall.
We still assume that vegetation has a microclimatic effect, particularly within a 30 cm distance. The greater impact of vegetation likely lies in shading the facade, protecting it from direct radiation. Additionally, vegetation can buffer extreme temperatures and store heat during the winter.
We also affirm that further research is required to describe or predict the temperature effect of LWs under different conditions and different LW characteristics [11]. In future experiments, it would be beneficial to carry out long-term temperature measurements at different distances and positions, using different plant species.

5. Conclusions

  • Temperature categories and calculations of Tdiffs based on TA are useful when seasonal variations are not too far apart.
  • We recommend using radiation-protected TA sensors (no sensors with diy covers) to minimize radiation errors, particularly those placed at a distance from LWs. All parameters should be measured with the same kind of sensors.
  • The IR images allowed a more detailed differentiation of surface temperatures among individual plants, irrigation influence, and microclimate determination. In future research, this method should be employed in addition to temperature sensors.
  • TA had the greatest influence on TV. We could rarely detect the effect of evaporative cooling. It is likely that the temperature effect described for building insulation consists mainly of shading that protects the facade from direct solar radiation. Even if this is the case, the redirection of radiation also affects the climate in urban areas.
  • Another important factor influencing the TV was the measurement position (distance to the vegetation). The amount of biomass or the plant species had less influence. The exposure showed almost no effect.
The climatic conditions for plants should be determined in a further experiment under real urban conditions. The comparison could be made with a different building material and in contrast to the TA. Our methodology provides first results on how a differentiated measurement of the temperature in the vegetation of green facades can work. Since cooling by green infrastructure is desired in urban spaces, it is important to find out how LWs have to be constructed in order to achieve the cooling effect. For this purpose, measurements have to be made on LWs, which we have tested in our experiments.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/su151511672/s1.

Author Contributions

Both authors designed the experimental setup, methodology, and conceptualization of the manuscript. A.v.B. was responsible for fundraising for the project, and conceived and supervised the project. M.S. served as project administrator, performed the field trial, and recorded the data. M.S. analyzed and visualized the data, conducted the literature review, and wrote the manuscript. A.v.B. edited the manuscript. All authors have read and agreed to the published version of the manuscript.

Funding

We acknowledge the support received from the Open Access Publishing Fund of Geisenheim University, GFHG Gesellschaft zur Förderung der Hochschule Geisenheim e.V. and the financier ZIM for the project “Begrünte Fassadenkacheln” (FKZ 4013810HF6).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The original contributions presented in the study are included in the article/Supplementary Materials. Further inquiries can be directed to the corresponding author.

Acknowledgments

We would like to thank all our colleagues and student assistants for their support in setting up and maintaining the experiment. In particular, we are grateful for their help in setting up the various setups (e.g., “new Nepal”) and moving the sensors.

Conflicts of Interest

The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

Abbreviations

Aappendix
Alu potaluminum cover protection pot
IRinfrared/thermal imaging
LWliving wall
Ttemperature
TAair temperature
TdiffTdiff between vegetation/control and the TA
TVvegetation temperature

Appendix A

Figure A1. Temperature of the single plant species (1); results: 4.
Figure A1. Temperature of the single plant species (1); results: 4.
Sustainability 15 11672 g0a1
Figure A2. Temperature of the single plant species (2); results: 4.
Figure A2. Temperature of the single plant species (2); results: 4.
Sustainability 15 11672 g0a2
Figure A3. Cascade: Temperature in a fixed distance to the wall (1); results: 7.
Figure A3. Cascade: Temperature in a fixed distance to the wall (1); results: 7.
Sustainability 15 11672 g0a3
Figure A4. Ground cover: Temperature in a fixed distance to the wall (2); results: 7.
Figure A4. Ground cover: Temperature in a fixed distance to the wall (2); results: 7.
Sustainability 15 11672 g0a4
Figure A5. Control: Temperature in a fixed distance to the wall (3); results: 7.
Figure A5. Control: Temperature in a fixed distance to the wall (3); results: 7.
Sustainability 15 11672 g0a5
Figure A6. Meadow: Temperature in a fixed distance to the wall (4); results: 7.
Figure A6. Meadow: Temperature in a fixed distance to the wall (4); results: 7.
Sustainability 15 11672 g0a6
Figure A7. Daily temperature cycle: IR camera vs. temperature sensors; results: 8.
Figure A7. Daily temperature cycle: IR camera vs. temperature sensors; results: 8.
Sustainability 15 11672 g0a7
Figure A8. Air temperature at the experimental wall and in the field. Climate data at the experimental wall (1); results: 9.
Figure A8. Air temperature at the experimental wall and in the field. Climate data at the experimental wall (1); results: 9.
Sustainability 15 11672 g0a8
Figure A9. Radiation at the experimental wall and in the field. Climate data at the experimental wall (2); results: 9.
Figure A9. Radiation at the experimental wall and in the field. Climate data at the experimental wall (2); results: 9.
Sustainability 15 11672 g0a9
Figure A10. PAR at the experimental wall and in the field.. PAR measurement set up (A); Overview of the measured radiation parameters at the different exposures (B).
Figure A10. PAR at the experimental wall and in the field.. PAR measurement set up (A); Overview of the measured radiation parameters at the different exposures (B).
Sustainability 15 11672 g0a10

References

  1. Goel, M.; Jha, B.; Khan, S. Living walls enhancing the urban realm: A review. Environ. Sci. Pollut. Res. Int. 2022, 29, 38715–38734. [Google Scholar] [CrossRef] [PubMed]
  2. Hunter, A.M.; Williams, N.S.G.; Rayner, J.P.; Aye, L.; Hes, D.; Livesley, S.J. Quantifying the thermal performance of green facades: A critical review. Ecol. Eng. 2014, 63, 102–113. [Google Scholar] [CrossRef]
  3. Manso, M.; Castro-Gomes, J. Green wall systems: A review of their characteristics. Renew. Sustain. Energy Rev. 2015, 41, 863–871. [Google Scholar] [CrossRef]
  4. Radić, M.; Brković Dodig, M.; Auer, T. Green Facades and Living Walls—A Review Establishing the Classification of Construction Types and Mapping the Benefits. Sustainability 2019, 11, 4579. [Google Scholar] [CrossRef] [Green Version]
  5. Riley, B. The state of the art of living walls: Lessons learned. Build. Environ. 2017, 114, 219–232. [Google Scholar] [CrossRef]
  6. Besir, A.B.; Cuce, E. Green roofs and facades: A comprehensive review. Renew. Sustain. Energy Rev. 2018, 82, 915–939. [Google Scholar] [CrossRef]
  7. Nicole, P.; Jenner, N.; Henrich, J.; Heusinger, J.; Weber, S.; Schreiner, J.; Kanashiro, C. Gebäude, Begrünung und Energie: Potenziale und Wechselwirkungen: Interdisziplinärer Leitfaden als Planungshilfe zur Nutzung energetischer, klimatischer und gestalterischer Potenziale sowie zu den Wechselwirkungen von Gebäude, Bauwerksbegrünung und Gebäudeumfeld. 2013. Available online: http://www.irbnet.de/daten/rswb/13109006683.pdf (accessed on 23 November 2016).
  8. Edelmann, H.G.; Poku, M.A. Effekte und Parameter von Efeu bewachsenen Fassaden im Vergleich zu blanken Hausfassaden. In Biodiversität und Klima, Vernetzung der Akteure in Deutschland XIV Dokumentation der 14. Tagung; Korn, H., Harald, D., Schliep, R., Eds.; Bundesamt für Naturschutz: Bonn, Germany, 2018; pp. 26–30. [Google Scholar]
  9. Bolton, C.; Rahman, M.A.; Armson, D.; Ennos, A.R. Effectiveness of an ivy covering at insulating a building against the cold in Manchester, U.K: A preliminary investigation. Build. Environ. 2014, 80, 32–35. [Google Scholar] [CrossRef]
  10. Duthweiler, S.; Eben, P. Mikroklimatische Wirkungen von Kletterpflanzen. Stadt Grün 2022, 25–29. Available online: https://stadtundgruen.de/artikel/forschungsversuch-zur-fassadenbegruenung-eines-hochhauses-mikroklimatische-wirkungen-von-kletterpflanzen-5129 (accessed on 24 July 2023).
  11. Brune, M. Gebäudebegrünung und Klimawandel: Anpassung an Die Folgen des Klimawandels Durch Klimawandeltaugliche Begrünung; Climate Service Center Germany: Hamburg, Germany, 2017. [Google Scholar]
  12. Perini, K.; Ottelé, M.; Haas, E.M.; Raiteri, R. Greening the building envelope, façade greening and living wall systems. Open J. Ecol. 2011, 1, 1–8. [Google Scholar] [CrossRef] [Green Version]
  13. Eumorfopoulou, E.A.; Kontoleon, K.J. Experimental approach to the contribution of plant-covered walls to the thermal behaviour of building envelopes. Build. Environ. 2009, 44, 1024–1038. [Google Scholar] [CrossRef]
  14. Mazzali, U.; Peron, F.; Romagnoni, P.; Pulselli, R.M.; Bastianoni, S. Experimental investigation on the energy performance of Living Walls in a temperate climate. Build. Environ. 2013, 64, 57–66. [Google Scholar] [CrossRef]
  15. Wong, N.H.; Tan, A.Y.K.; Cehn, Y.; Sekar, K.; Tan, P.Y.; Chan, D.; Chiang, K.; Wong, N.C. Thermal evaluation of vertical greenery systems for building walls. Build. Environ. 2010, 45, 663–672. [Google Scholar] [CrossRef]
  16. Haggag, M.; Hassan, A.; Elmasry, S. Experimental study on reduced heat gain through green façades in a high heat load climate. Energy Build. 2014, 82, 668–674. [Google Scholar] [CrossRef]
  17. Chen, Q.; Li, B.; Liu, X. An experimental evaluation of the living wall system in hot and humid climate. Energy Build. 2013, 61, 298–307. [Google Scholar] [CrossRef]
  18. Cheng, C.Y.; Cheung, K.K.S.; Chu, L.M. Thermal performance of a vegetated cladding system on facade walls. Build. Environ. 2010, 45, 1779–1787. [Google Scholar] [CrossRef]
  19. Cameron, R.W.F.; Taylor, J.E.; Emmett, M.R. What’s ‘cool’in the world of green façades?: How plant choice influences the cooling properties of green walls. Build. Environ. 2014, 73, 198–207. [Google Scholar] [CrossRef] [Green Version]
  20. Žuvela-Aloise, M.; Koch, R.; Buchholz, S.; Früh, B. Modelling the potential of green and blue infrastructure to reduce urban heat load in the city of Vienna. Clim. Chang. 2016, 135, 425–438. [Google Scholar] [CrossRef] [Green Version]
  21. Alexandri, E.; Jones, P. Temperature decreases in an urban canyon due to green walls and green roofs in diverse climates. Build. Environ. 2008, 43, 480–493. [Google Scholar] [CrossRef]
  22. Koch, K.; Ysebaert, T.; Denys, S.; Samson, R. Urban heat stress mitigation potential of green walls: A review. Urban For. Urban Green. 2020, 55, 126843. [Google Scholar] [CrossRef]
  23. Bianco, L.; Serra, V.; Larcher, F.; Perino, M. Thermal behaviour assessment of a novel vertical greenery module system: First results of a long-term monitoring campaign in an outdoor test cell. Energy Effic. 2017, 10, 625–638. [Google Scholar] [CrossRef]
  24. Gräf, M.; Immitzer, M.; Hietz, P.; Stangl, R. Water-Stressed Plants Do Not Cool: Leaf Surface Temperature of Living Wall Plants under Drought Stress. Sustainability 2021, 13, 3910. [Google Scholar] [CrossRef]
  25. Mårtensson, L.-M.; Wuolo, A.A.; Fransson, A.-M.; Emilsson, T.T. Plant performance in living wall systems in the Scandinavian climate. Ecol. Eng. 2014, 71, 610–614. [Google Scholar] [CrossRef] [Green Version]
  26. Cameron, R.W.F.; Taylor, J.; Emmett, M. A Hedera green façade—Energy performance and saving under different maritime-temperate, winter weather conditions. Build. Environ. 2015, 92, 111–121. [Google Scholar] [CrossRef] [Green Version]
  27. Hietel, E.; Stollberg, M.; von Birgelen, A. “Unkräuter” in der Dach- und Fassadenbegrünung: Erfahrungsbericht aus der Forschung in Bingen und Geisenheim. Stadt Grün 2022. Available online: https://stadtundgruen.de/artikel/erfahrungsbericht-aus-der-forschung-in-bingen-und-geisenheim-unkraeuter-in-der-dach-und-fassadenbegruenung-5237 (accessed on 24 July 2023).
  28. Stollberg, M.; von Birgelen, A.; Mählmann, J. Begrünte Fassadenkacheln—Pflanzen für die Wandbegrünung: Eignung von Stauden in textilen Vegetationsträgern. Stadt Grün 2021. Available online: https://stadtundgruen.de/artikel/eignung-von-stauden-in-textilen-vegetationstraegern-begruente-fassadenkacheln-pflanzen-fuer-die-wandbegruenung-5567 (accessed on 24 July 2023).
  29. Stollberg, M.; von Birgelen, A. Plants and polyester: Suitable plants for a textile-based living wall system. Acta Hortic. 2022, 100, 189–196. [Google Scholar] [CrossRef]
  30. Stollberg, M.; Moser, G.; Müller, C.; von Birgelen, A. Meadow-living walls: Creating attractive vertical greenery with meadow seed mixtures—Experiences and recommendations from a three year field trial. Ecol. Eng. 2022, 185, 106817. [Google Scholar] [CrossRef]
  31. Stollberg, M.; von Birgelen, A. Vertical plants: Plant design of Living walls—Evaluation of 34 perennials in a textile based Living wall over a three years experiment. Front. Hortic. 2023, 2, 1091026. [Google Scholar] [CrossRef]
  32. Pérez, G.; Coma, J.; Martorell, I.; Cabeza, L.F. Vertical Greenery Systems (VGS) for energy saving in buildings: A review. Renew. Sustain. Energy Rev. 2014, 39, 139–165. [Google Scholar] [CrossRef] [Green Version]
Figure 1. Experimental setup and position of the experimental walls (space for weather station means possible connector for data collection).
Figure 1. Experimental setup and position of the experimental walls (space for weather station means possible connector for data collection).
Sustainability 15 11672 g001
Figure 2. First try: Temperature differences between variants and positions. Variants (AD): Control (A), Meadow (B), Cascade (C), Groundcover (D); Photo of the temperature sensor set up (E); Table with temperature averages of the variants at the different positions (F).
Figure 2. First try: Temperature differences between variants and positions. Variants (AD): Control (A), Meadow (B), Cascade (C), Groundcover (D); Photo of the temperature sensor set up (E); Table with temperature averages of the variants at the different positions (F).
Sustainability 15 11672 g002
Figure 3. Advanced setup. Set up of the temperature sensors (A); Results of the temperature measurements of the different variants at the three positions in February and April 2018 (B).
Figure 3. Advanced setup. Set up of the temperature sensors (A); Results of the temperature measurements of the different variants at the three positions in February and April 2018 (B).
Sustainability 15 11672 g003
Figure 4. Influence of the biomass. Maintenance: cutting the meadow (AC). Overview of temperatures before and after cut (D,E).
Figure 4. Influence of the biomass. Maintenance: cutting the meadow (AC). Overview of temperatures before and after cut (D,E).
Sustainability 15 11672 g004
Figure 5. Temperature (mean, °C) at the east in Meadow and the Control. Temperature of categories 2 and 3 before and after cut compared to the air temperature (°C).
Figure 5. Temperature (mean, °C) at the east in Meadow and the Control. Temperature of categories 2 and 3 before and after cut compared to the air temperature (°C).
Sustainability 15 11672 g005
Figure 6. Temperature of the single plants. Overview of the mean, minimum, and maximum TV overall temperature categories. Blue indicates that the minimum temperature was colder. With more yellow, the maximum temperature was warmer.
Figure 6. Temperature of the single plants. Overview of the mean, minimum, and maximum TV overall temperature categories. Blue indicates that the minimum temperature was colder. With more yellow, the maximum temperature was warmer.
Sustainability 15 11672 g006
Figure 7. Differences within one mat. Measurement in a grid for Cascade and Control (A); Averages of profile temperature (B1); Temperature sensors set up for grid and profile measurement: grid, columns 1 to 3, rows A to D; profile: top, middle, below (B2); Boxplots of temperature in the profile positions during a certain period of time see (B3); Temperature curve of different variants and positions in December 2018 or February 2019 (B4).
Figure 7. Differences within one mat. Measurement in a grid for Cascade and Control (A); Averages of profile temperature (B1); Temperature sensors set up for grid and profile measurement: grid, columns 1 to 3, rows A to D; profile: top, middle, below (B2); Boxplots of temperature in the profile positions during a certain period of time see (B3); Temperature curve of different variants and positions in December 2018 or February 2019 (B4).
Sustainability 15 11672 g007
Figure 8. Material test for radiation protection.
Figure 8. Material test for radiation protection.
Sustainability 15 11672 g008
Figure 9. Temperature measurements from a fixed distance to the experimental wall. Set up of the temperature sensors (A); Boxplots (B) and averages (C) of Tdiff of the different variants in 30 and 150 cm distance between April and July 2019. An Asterix * mean significant differences between the positions.
Figure 9. Temperature measurements from a fixed distance to the experimental wall. Set up of the temperature sensors (A); Boxplots (B) and averages (C) of Tdiff of the different variants in 30 and 150 cm distance between April and July 2019. An Asterix * mean significant differences between the positions.
Sustainability 15 11672 g009
Figure 10. IR vs. measurement with temperature sensors. Setup of the temperature sensor and the IR (A), Boxplots of the temperature at daytime of 18 and 19 of June 2018 for the different variants and positions. Statistic was done with Kruskal-Wallis Test. Different letters indicated significant differences between variants in one positions (upper) and between positions in one variant (lower) (B). Overview of the results (C).
Figure 10. IR vs. measurement with temperature sensors. Setup of the temperature sensor and the IR (A), Boxplots of the temperature at daytime of 18 and 19 of June 2018 for the different variants and positions. Statistic was done with Kruskal-Wallis Test. Different letters indicated significant differences between variants in one positions (upper) and between positions in one variant (lower) (B). Overview of the results (C).
Sustainability 15 11672 g010
Figure 11. IR measurement setup (A) and example IR images (B). Commas represent the decimal dot (software-dependent).
Figure 11. IR measurement setup (A) and example IR images (B). Commas represent the decimal dot (software-dependent).
Sustainability 15 11672 g011
Figure 12. Climate data of the weather stations at the experimental walls (east and west) compared to the field weather station from February to June 2019. Boxplot of air temperature (A); Sum of radiation (B); Overview of different climate parameter (C).
Figure 12. Climate data of the weather stations at the experimental walls (east and west) compared to the field weather station from February to June 2019. Boxplot of air temperature (A); Sum of radiation (B); Overview of different climate parameter (C).
Sustainability 15 11672 g012
Table 1. Overview of the material and methods of the different experiments.
Table 1. Overview of the material and methods of the different experiments.
Name1. First Try: Differences between the Variants and Positions2. Advanced Setup to Measure Differences between the Variants and Positions
Time periodOctober 2017 to February 2018February to May 2018
Research questionIs there a difference between the variants and the measurement position?Is there a difference between the variants and the measurement position (in a period with strong increasing and decreasing temperatures)?
WallEastEast
VariantsAllAll
nn = 1 sensorn = 2
SetupSensors back, into the mat (middle), and in front (35 cm distance)Different positions: 1, into: inserted in mat; 2, back: behind mat; 3, front: distance of 60 cm from the wall and between two variants
Temperature sensor typeSensors (unprotected from radiation)Sensors (unprotected from radiation)
Figure23
Name3. Influence of the amount of biomass4. Temperature of the single plants
Time periodBefore cut: from the 5th of July to the 24th of July; cut was on 25th of July. After cut, we measured from the 31st of July to the 17th of AugustSeptember 2018 and January 2019
Research questionDoes biomass influence the temperature?Do different plant species affect temperature?
WallEastAll
VariantsMeadow and ControlCascade, Ground cover (most single plants)
nn = 2 Control and n = 4 Meadown = 3 single plants
SetupMeadow before and after cutting, eastern exposition. Before cut: T sensors placed into mat, at a distance of 30 cm from the mat, and covered by vegetation. After cut: T sensors placed in any position of the mats, at a distance of about 5 cm from each other, ensuring that they are covered by vegetation. Both: Sensors plugged into the mat (0 cm)Sensors were placed in the vegetation of each single plant species and below, into the mat
Temperature sensor typeSensors (unprotected from radiation), field weather station nearbySensors (unprotected from radiation), field weather station nearby
Figure4 to 56
StatisticWe selected comparable weather data before and after the cut and built 3 categories to compare the results under similar conditions. Data from the field weather station were used to calculate the categories and the difference temperature (Tdiffs). Data were not normally distributed. We carried out the analysis of significant differences between temperature before and after cut with Mann–Whitney U test. We compared measured TV with TA from the weather station nearbyWe categorized the TA and compared the TV from the different plants within a temperature category to compare the data. In addition, we calculated the difference between air and TV. Data from the field weather station was used to calculate the Tdiffs. Weather and data of TV were not normally distributed. We tested significant differences with Mann–Whitney U test and Kruskal–Wallis test with post hoc test. Mean from the total period was used for an overview of Tdiff of vegetation. We categorized the days in the experimental period based on mean daily temperature. With a histogram, all experimental days were divided into temperature categories so we could form the categories equally (see Supplementary Materials)
Appendix A/Supplements MaterialsSupplementary File S1Figure A1 and Figure A2; Supplementary Files S2–S5
Name5. Differences within one mat6. Alu pot radiation protection
Time periodDecember 2018 to February 2019April 19
Research questionAre there differences within a mat depending on the position? Could soil temperature sensors provide useful data on temperature in front of LWs, and are soil temperature sensors affected by radiation errors that can be reduced with alu pot covers?
WallEast and westEast and west
VariantsGrid: Control and Cascade, profile: allAll sensors were at the same position in front of the wall
nn = 1 mat, n = 3 T sensorsn = 1 sensor
SetupT sensors into one mat in a grid or a profile. We placed all sensors into only one mat to measure as many positions as possibleThree psychrometers could measure the temperature without the influence of radiation. We wanted more measuring points and to create radiation protection for the sensors. To perform this, we tried different materials and compared the temperature at the same measurement point. From this experience, we decided to use an open plant pot covered with aluminum foil (alu pot) for protection
Temperature sensor typeSensors (unprotected from radiation), field weather station nearbySensors (alu pot), psychrometer, field weather station nearby
Figure78
StatisticData were analyzed in comparable time periods. We compared TV with TA from the weather station nearbyRandom selection of a time period which was plotted
Appendix A/Supplements MaterialsSupplementary File S6
Name7. Temperature in a fixed distance to the wall8. IR camera vs. temperature sensors
Time periodApril 2019 to July 2019June 2019
Research questionDoes the temperature vary at different distances in front of the experimental walls?Is there a difference between the measurement with temperature sensors (distance temperature) and with an IR camera (surface temperature)?
WallAllSouth
VariantsAllCascade, Ground cover, Control
nn = 4 per variant, n = 1 temperature sensor in distance.n = 138 IR pictures, n = 1–2 per variant, n = 1 temperature sensor in distance
SetupNew setup: Sensors in a fixed distance of 30 and 150 cm in front of the experimental wall. Installation: wooden laths were attached to the experimental wall, from which link chains hung. Sensors were attached hereAdvanced setup: extended (30, 90, and 150 cm distance) and installed sensors at a distance of 90 cm. Measurements with the IR camera in a distance of 6 m
Temperature sensor typeSensors (protected with open plant pot covered with aluminum foil (alu pot)) with field weather station nearbySensors (alu pot), IR camera, wall weather station, and field weather station
Figure910 to 11
StatisticData were not normally distributed, and we tested significant differences between distances of 30 and 150 cm with Mann–Whitney U test; the selection of the DOY for the graphs was random. Both distances 30 and 150 cm should have been measured simultaneously if possible. Two related days were combined if there was no measurement for two days in both distances. We compared temperatures in different distances with TA from the weather station nearbyOnly daytime was analyzed (10.00 to 18.00 h); if data were partly normally distributed, we used nonparametric test; we compared temperatures at different distances and with TA from the weather station nearby and at the wall. IR images were analyzed with InfRec Analyzer. We selected points (the same on every picture) and maintained the same color scheme for all pictures
Appendix A/Supplements MaterialsFigure A3, Figure A4, Figure A5 and Figure A6; Supplementary Files S7 and S8Figure A7; Supplementary File S9
Name9. Climate data at the experimental wall
Time periodFebruary to June 2019
Research questionWhich climate conditions prevail at the experimental walls?
WallWest, east, and field
Variants
nn = 1 weather station
SetupWeather stations are in the center of the west and the eastern walls. The data from this field weather station were used to calculate the Tdiffs in previous experiments
Temperature sensor typeWall weather station and field weather station, PAR meters
Figure12
StatisticWe compared climate data from the wall weather stations with the data from the weather station nearby in the field
Appendix A/Supplements MaterialsFigure A8, Figure A9 and Figure A10; Supplementary File S10
Table 2. Biomass data (mean, n = 3–4) before and after cutting Meadow.
Table 2. Biomass data (mean, n = 3–4) before and after cutting Meadow.
ParameterWestEast
Height (cm)before cut67.6 cm55.2 cm
after cut13.6 cm10.9 cm
Coverage (%)before cut117.5%123.5%
after cut30.8%27.3%
Dry mass (kg)cut material3.49 kg2.79 kg
Table 3. Vegetation and TA (°C) (minimum and maximum) from the measurement period and calculated value area (absolute difference between Min and Max temperature = K).
Table 3. Vegetation and TA (°C) (minimum and maximum) from the measurement period and calculated value area (absolute difference between Min and Max temperature = K).
PlantTV (°C)TA (°C)
MinMaxabs. diff. Min–Max (K)MinMaxabs. diff. Min–Max (K)
Achillea ptarmica0.517.817.2−415.819.8
Ajuga tenorii ‘Mauro’4.447.643.3−0.229.830
Alchemilla caucasica3.723.219.5−2.417.620
Asplenium scolopendrium−1.729.230.9−4.226.730.9
Carex dolichostachya ‘Silver Sceptre’0.021.821.8−4.216.120.3
Geum coccineum ‘Carlskaer’0.315.815.5−312.315.3
Glechoma hederacea1.030.629.61.125.824.7
Hemerocallis x cultorum ‘Mini Stella’3.920.516.50.117.117
Heuchera Hybride ‘Purple Petticoats’−3.249.953.1−4.213.717.9
Iris foetidissima0.019.519.5−4.211.515.7
Lysimachia nummularia ‘Aurea’−3.631.435.0−4.231.235.4
Ophiopogon japonicus ‘Sparkler’6.434.227.83.526.923.4
Ophiopogon planiscapus0.032.032.0−4.224.328.5
Pachysandra terminalis1.222.321.00.117.117
Polypodium vulgare3.425.021.53.526.723.2
Polystichum acrostichoides1.012.411.41.58.26.7
Polystichum setiferum ‘Proliferum’3.420.817.43.517.614.1
Tellima grandiflora ‘Rubra’3.413.29.84.711.77
Waldsteinia ternata3.734.030.23.631.728.1
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Stollberg, M.; von Birgelen, A. Living Wall Plants Are Affected by and Affect Temperature: How to (not) Measure Plants’ Temperature in a Living Wall Experiment. Sustainability 2023, 15, 11672. https://doi.org/10.3390/su151511672

AMA Style

Stollberg M, von Birgelen A. Living Wall Plants Are Affected by and Affect Temperature: How to (not) Measure Plants’ Temperature in a Living Wall Experiment. Sustainability. 2023; 15(15):11672. https://doi.org/10.3390/su151511672

Chicago/Turabian Style

Stollberg, Maren, and Alexander von Birgelen. 2023. "Living Wall Plants Are Affected by and Affect Temperature: How to (not) Measure Plants’ Temperature in a Living Wall Experiment" Sustainability 15, no. 15: 11672. https://doi.org/10.3390/su151511672

APA Style

Stollberg, M., & von Birgelen, A. (2023). Living Wall Plants Are Affected by and Affect Temperature: How to (not) Measure Plants’ Temperature in a Living Wall Experiment. Sustainability, 15(15), 11672. https://doi.org/10.3390/su151511672

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop