Impact of Bedroom Ventilation Strategy on Air Change Rates and Indoor Air Parameters in the Autumn–Winter Seasons—In Situ Study in Poland

by
Maria Kostka
1,*,
Zuzanna Kołodko
1 and
Magdalena Baborska-Narożny
2,*
1
Faculty of Environmental Engineering, Wroclaw University of Science and Technology, ul. Norwida 4/6, 50-373 Wroclaw, Poland
2
Faculty of Architecture, Wroclaw University of Science and Technology, ul. Bolesława Prusa 53/55, 50-317 Wroclaw, Poland
*
Authors to whom correspondence should be addressed.
Energies 2025, 18(16), 4279; https://doi.org/10.3390/en18164279
Submission received: 30 June 2025 / Revised: 27 July 2025 / Accepted: 4 August 2025 / Published: 11 August 2025
(This article belongs to the Special Issue Recent Challenges in Buildings Ventilation and Indoor Air Quality)

Abstract

Hybrid ventilation is indicated as one of the effective methods of maintaining thermal comfort and indoor air quality and reducing energy consumption in buildings. It assumes the capacity to switch between natural and mechanical ventilation, allowing the most efficient use of the outdoor air potential. This article aims to quantify the impact of changing ventilation system, from natural to hybrid, on indoor air parameters and air change rates in a bedroom of a single-family house. The distinct aspects of this study include longitudinal measurement over three years, natural ventilation substituted by hybrid ventilation halfway into the monitoring period, and unaltered building and user characteristics. The analysis is based on measurements of temperature, relative humidity, CO2 concentration, and window opening for three seven-month measurement periods from September 1 to March 31. The measurements are complemented by in-depth user feedback and an audit of the building structure and installed HVAC systems. A clear correlation was observed between the values of relative humidity and carbon dioxide concentration and the type of ventilation strategy. A significant influence of residents’ behavior on the achieved indoor air parameters was observed.
Keywords: hybrid ventilation; MVHR; natural ventilation; indoor air quality; bedroom ventilation hybrid ventilation; MVHR; natural ventilation; indoor air quality; bedroom ventilation

Share and Cite

MDPI and ACS Style

Kostka, M.; Kołodko, Z.; Baborska-Narożny, M. Impact of Bedroom Ventilation Strategy on Air Change Rates and Indoor Air Parameters in the Autumn–Winter Seasons—In Situ Study in Poland. Energies 2025, 18, 4279. https://doi.org/10.3390/en18164279

AMA Style

Kostka M, Kołodko Z, Baborska-Narożny M. Impact of Bedroom Ventilation Strategy on Air Change Rates and Indoor Air Parameters in the Autumn–Winter Seasons—In Situ Study in Poland. Energies. 2025; 18(16):4279. https://doi.org/10.3390/en18164279

Chicago/Turabian Style

Kostka, Maria, Zuzanna Kołodko, and Magdalena Baborska-Narożny. 2025. "Impact of Bedroom Ventilation Strategy on Air Change Rates and Indoor Air Parameters in the Autumn–Winter Seasons—In Situ Study in Poland" Energies 18, no. 16: 4279. https://doi.org/10.3390/en18164279

APA Style

Kostka, M., Kołodko, Z., & Baborska-Narożny, M. (2025). Impact of Bedroom Ventilation Strategy on Air Change Rates and Indoor Air Parameters in the Autumn–Winter Seasons—In Situ Study in Poland. Energies, 18(16), 4279. https://doi.org/10.3390/en18164279

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop