Next Article in Journal
Design of a Tandem Compressor for the Electrically-Driven Turbocharger of a Hybrid City Car
Next Article in Special Issue
Identification of the Major Noise Energy Sources in Rail Vehicles Moving at a Speed of 200 km/h
Previous Article in Journal
Sliding Mode Control with Minimization of the Regulation Time in the Presence of Control Signal and Velocity Constraints
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Effective Method for Diagnosing Continuous Welded Track Condition Based on Experimental Research

1
Faculty of Transport, Warsaw University of Technology, Koszykowa 75, 00662 Warsaw, Poland
2
Faculty of Production Engineering, Warsaw University of Technology, Narbutta 85, 02524 Warsaw, Poland
*
Author to whom correspondence should be addressed.
Energies 2021, 14(10), 2889; https://doi.org/10.3390/en14102889
Submission received: 25 April 2021 / Revised: 10 May 2021 / Accepted: 12 May 2021 / Published: 17 May 2021

Abstract

The correct operation of the continuous welded track requires diagnosing its condition and preparation of track metrics requiring measurements of displacements of rail under operation. This is required as there are additional thermal stresses in the rails with values depending on the temperature changes of the rails. Therefore, the climatic conditions are important. This paper presents the original effective analytical method for diagnosing the condition of continuous welded track based on experimental research. The method allows for an appropriate repair or maintenance recommendation. In the experimental research, the authors considered track diagnostic conditions for two conditions: track under load and track without load. This paper presents empirical formulas for calculating rail temperature and longitudinal force based on ambient temperature, developed from long-term measurements. The formulas were developed for a track located on a straight section—both for a rail loaded and unloaded with a passing train under the following conditions: 60E1 rail, not on an engineering structure, conventional surface, wooden sleepers and very high train traffic load. The obtained results in the value of the correlation coefficient R2 ≥ 0.995 attest to very high accuracy of the calculations performed with the method proposed by the authors.
Keywords: continuous welded track; experimental research; diagnosis method; measurements; method continuous welded track; experimental research; diagnosis method; measurements; method

Share and Cite

MDPI and ACS Style

Kukulski, J.; Gołębiowski, P.; Makowski, J.; Jacyna-Gołda, I.; Żak, J. Effective Method for Diagnosing Continuous Welded Track Condition Based on Experimental Research. Energies 2021, 14, 2889. https://doi.org/10.3390/en14102889

AMA Style

Kukulski J, Gołębiowski P, Makowski J, Jacyna-Gołda I, Żak J. Effective Method for Diagnosing Continuous Welded Track Condition Based on Experimental Research. Energies. 2021; 14(10):2889. https://doi.org/10.3390/en14102889

Chicago/Turabian Style

Kukulski, Jacek, Piotr Gołębiowski, Jacek Makowski, Ilona Jacyna-Gołda, and Jolanta Żak. 2021. "Effective Method for Diagnosing Continuous Welded Track Condition Based on Experimental Research" Energies 14, no. 10: 2889. https://doi.org/10.3390/en14102889

APA Style

Kukulski, J., Gołębiowski, P., Makowski, J., Jacyna-Gołda, I., & Żak, J. (2021). Effective Method for Diagnosing Continuous Welded Track Condition Based on Experimental Research. Energies, 14(10), 2889. https://doi.org/10.3390/en14102889

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop