Next Article in Journal
Comparing the Biomass Yield and Biogas Potential of Phragmites australis with Miscanthus x giganteus and Panicum virgatum Grown in Canada
Previous Article in Journal
Optimal Scheduling of Power System Incorporating the Flexibility of Thermal Units
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

The Virtual Harmonic Power Droop Strategy to Mitigate the Output Harmonic Voltage of the Inverter

New Energy Research Center of Electric Power, South China University of Technology, Guangzhou 510641, China
*
Author to whom correspondence should be addressed.
Energies 2018, 11(9), 2196; https://doi.org/10.3390/en11092196
Submission received: 16 July 2018 / Revised: 15 August 2018 / Accepted: 18 August 2018 / Published: 22 August 2018

Abstract

The harmonic voltage issue becomes a challenge for a distributed generation system. Considering that droop control is the most common control algorithm used in the distributed system, a virtual harmonic power droop strategy which aims to mitigate the harmonic voltage is proposed in this paper. First, the conventional droop control is analyzed. Based on that concept, the virtual power algorithm is introduced. Second, the output harmonic voltage issue and the mathematical model of the inverter are presented. In addition, the second-order generalized integrator is briefly discussed. Third, taking into consideration the algorithms and models presented, a virtual harmonic power droop strategy is proposed to implement the harmonic voltage mitigation. In this algorithm, signals in fundamental frequency and harmonic frequency are separated with the help of second-order generalized integrators. Unlike the conventional voltage–current dual loop structure which is used to mitigate system harmonics, this method only needs the virtual power feedback to mitigate the harmonic voltage. Based on these features, the system’s control structure is simplified. Simulation and experimental results verified the harmonic voltage mitigation ability of the proposed strategy.
Keywords: droop control; harmonic voltage; second-order generalized integrator; virtual power droop control; harmonic voltage; second-order generalized integrator; virtual power

Share and Cite

MDPI and ACS Style

Yao, Y.; Kang, L. The Virtual Harmonic Power Droop Strategy to Mitigate the Output Harmonic Voltage of the Inverter. Energies 2018, 11, 2196. https://doi.org/10.3390/en11092196

AMA Style

Yao Y, Kang L. The Virtual Harmonic Power Droop Strategy to Mitigate the Output Harmonic Voltage of the Inverter. Energies. 2018; 11(9):2196. https://doi.org/10.3390/en11092196

Chicago/Turabian Style

Yao, Yuan, and Longyun Kang. 2018. "The Virtual Harmonic Power Droop Strategy to Mitigate the Output Harmonic Voltage of the Inverter" Energies 11, no. 9: 2196. https://doi.org/10.3390/en11092196

APA Style

Yao, Y., & Kang, L. (2018). The Virtual Harmonic Power Droop Strategy to Mitigate the Output Harmonic Voltage of the Inverter. Energies, 11(9), 2196. https://doi.org/10.3390/en11092196