Next Article in Journal
Norway as a Battery for the Future European Power System—Impacts on the Hydropower System
Previous Article in Journal
Coordinated Control of a Wind-Methanol-Fuel Cell System with Hydrogen Storage
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Investigation of the Ampacity of a Prefabricated Straight-Through Joint of High Voltage Cable

1
School of Electric Power, South China University of Technology, Guangzhou 510640, China
2
School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane 4109, Australia
3
Cable Specialty Committee, Guangdong Society for Electrical Engineering, Guangzhou 510080, China
4
Transmission Management, Guangzhou Power Supply Co. Ltd., Guangzhou 510310, China
*
Author to whom correspondence should be addressed.
Energies 2017, 10(12), 2050; https://doi.org/10.3390/en10122050
Submission received: 23 October 2017 / Revised: 24 November 2017 / Accepted: 1 December 2017 / Published: 4 December 2017
(This article belongs to the Section F: Electrical Engineering)

Abstract

This paper presents a theoretical and experimental study on the ampacity of the prefabricated straight-through joint of a 110 kV high voltage cable. Thermal modelling revealed that the critical spot limiting the ampacity of this type of cable joint is located on its crosslinked polyethylene (XLPE) insulation section. The axial distribution of the thermal field in this type of cable joint was also determined. An algorithm for assessing ampacity in this type of cable joint was developed. Experiments were conducted on a real cable system with a prefabricated straight-through joint under different loading conditions. The experiments show a good agreement with the thermal modelling results.
Keywords: ampacity; cable joint; cable system; critical spot; thermal modelling ampacity; cable joint; cable system; critical spot; thermal modelling

Share and Cite

MDPI and ACS Style

Wang, P.; Liu, G.; Ma, H.; Liu, Y.; Xu, T. Investigation of the Ampacity of a Prefabricated Straight-Through Joint of High Voltage Cable. Energies 2017, 10, 2050. https://doi.org/10.3390/en10122050

AMA Style

Wang P, Liu G, Ma H, Liu Y, Xu T. Investigation of the Ampacity of a Prefabricated Straight-Through Joint of High Voltage Cable. Energies. 2017; 10(12):2050. https://doi.org/10.3390/en10122050

Chicago/Turabian Style

Wang, Pengyu, Gang Liu, Hui Ma, Yigang Liu, and Tao Xu. 2017. "Investigation of the Ampacity of a Prefabricated Straight-Through Joint of High Voltage Cable" Energies 10, no. 12: 2050. https://doi.org/10.3390/en10122050

APA Style

Wang, P., Liu, G., Ma, H., Liu, Y., & Xu, T. (2017). Investigation of the Ampacity of a Prefabricated Straight-Through Joint of High Voltage Cable. Energies, 10(12), 2050. https://doi.org/10.3390/en10122050

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.