Smartphone-Based Assessment of the Stretch–Shortening Cycle: Validity and Reliability of the My Jump Lab App for Measuring the Dynamic Rebound Index
Highlights
- The My Jump Lab smartphone application showed very large to nearly perfect validity for measuring jump height, contact time and Dynamic Rebound Index (DRI) during drop jumps compared to a force platform.
- The app demonstrated good to high reliability, both between sessions and within-session attempts, with low measurement error.
- My Jump Lab can be used as a practical and cost-effective alternative to force platforms for assessing drop jump performance and DRI in applied settings.
- The accessibility of smartphone-based assessment may facilitate wider monitoring of stretch-shortening cycle performance in sport and research contexts.
Abstract
1. Introduction
2. Materials and Methods
2.1. Design
2.2. Participants
2.3. Sample Size Estimation and Justification
2.4. Procedures
2.5. Instruments and Data Processing
2.6. Statistical Analyses
3. Results
4. Discussion
5. Conclusions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
Abbreviations
| SSC | Stretch-shortening cycle |
| RSI | Reactive strength index |
| DRI | Dynamic rebound index |
| GRF | Ground reaction force |
| SD | Standard deviation |
| CCC | Lin’s concordance correlation coefficient |
| ICC | Intraclass correlation coefficient |
| RMSE | Root mean square error |
| LOA | Limits of agreement |
| CV | Coefficient of variation |
| CI | Confidence interval |
References
- Bishop, C.; Turner, A.; Jordan, M.; Harry, J.; Loturco, I.; Lake, J.; Comfort, P. A Framework to Guide Practitioners for Selecting Metrics During the Countermovement and Drop Jump Tests. Strength Cond. J. 2022, 44, 95–103. [Google Scholar] [CrossRef]
- Xu, J.; Turner, A.; Comfort, P.; Harry, J.R.; McMahon, J.J.; Chavda, S.; Bishop, C. A Systematic Review of the Different Calculation Methods for Measuring Jump Height During the Countermovement and Drop Jump Tests. Sports Med. 2023, 53, 1055–1072. [Google Scholar] [CrossRef]
- Kale, M.; Asci, A.; Bayrak, C.I.; Acikada, C. Relationships among jumping performances and sprint parameters during maximum speed phase in sprinters. J. Strength Cond. Res. 2009, 23, 2272–2279. [Google Scholar] [CrossRef]
- Maloney, S.J.; Richards, J.; Nixon, D.G.D.; Harvey, L.J.; Fletcher, I.M. Do stiffness and asymmetries predict change of direction performance? J. Sports Sci. 2016, 35, 547–556. [Google Scholar] [CrossRef]
- Ramírez-Campillo, R.; Gallardo, F.; Henriquez-Olguín, C.; Meylan, C.M.; Martínez, C.; Álvarez, C.; Caniuqueo, A.; Cadore, E.L.; Izquierdo, M. Effect of vertical, horizontal and combined plyometric training on explosive, balance and endurance performance of young soccer players. J. Strength Cond. Res. 2015, 29, 1784–1795. [Google Scholar] [CrossRef]
- Castillo-Rodríguez, A.; Fernández-García, J.C.; Chinchilla-Minguet, J.L.; Carnero, E.Á. Relationship Between Muscular Strength and Sprints with Changes of Direction. J. Strength Cond. Res. 2012, 26, 725–732. [Google Scholar] [CrossRef]
- Sole, C.J.; Suchomel, T.J.; Stone, M.H. Preliminary scale of reference values for evaluating reactive strength index-modified in male and female ncaa division i athletes. Sports 2018, 6, 133. [Google Scholar] [CrossRef] [PubMed]
- Markwick, W.J.; Bird, S.P.; Tufano, J.J.; Seitz, L.B.; Haff, G.G. The intraday reliability of the reactive strength index calculated from a drop jump in professional men’s basketball. Int. J. Sports Physiol. Perform. 2015, 10, 482–488. [Google Scholar] [CrossRef] [PubMed]
- Comyns, T.M.; Flanagan, E.P.; Fleming, S.; Fitzgerald, E.; Harper, D.J. Interday Reliability and Usefulness of a Reactive Strength Index Derived From 2 Maximal Rebound Jump Tests. Int. J. Sports Physiol. Perform. 2019, 14, 1200–1204. [Google Scholar] [CrossRef]
- Sharp, A.; Neville, J.; Nagahara, R.; Wada, T.; Cronin, J. Using Multiple-Hop Assessments and Reactive Strength Indices to Differentiate Sprinting Performance in Sportsmen. Appl. Sci. 2025, 15, 1685. [Google Scholar] [CrossRef]
- Brooks, L.C. A Unified Mechanical Framework for Evaluating Stretch-Shortening Cycle Function. Eur. J. Sport Sci. 2026, 5, 1–10. [Google Scholar] [CrossRef]
- McMahon, J.J.; Suchomel, T.J.; Lake, J.P.; Comfort, P. Understanding the Key Phases of the Countermovement Jump Force-Time Curve. Strength Cond. J. 2018, 40, 96–106. [Google Scholar] [CrossRef]
- Montalvo, S.; Gonzalez, M.P.; Dietze-Hermosa, M.S.; Eggleston, J.D.; Dorgo, S. Common Vertical Jump and Reactive Strength Index Measuring Devices: A Validity and Reliability Analysis. J. Strength Cond. Res. 2021, 35, 1234–1243. [Google Scholar] [CrossRef]
- Balsalobre-Fernández, C.; Glaister, M.; Lockey, R.A. The validity and reliability of an iPhone app for measuring vertical jump performance. J. Sports Sci. 2015, 33, 1574–1579. [Google Scholar] [CrossRef] [PubMed]
- Balsalobre-Fernández, C.; Xu, J.; Jarvis, P.; Thompson, S.; Tannion, K.; Bishop, C. Validity of a Smartphone App Using Artificial Intelligence for the Real-Time Measurement of Barbell Velocity in the Bench Press Exercise. J. Strength Cond. Res. 2023, 37, e640–e645. [Google Scholar] [CrossRef]
- Sharp, A.P.; Cronin, J.B.; Neville, J. Using Smartphones for Jump Diagnostics: A Brief Review of the Validity and Reliability of the My Jump App. Strength Cond. J. 2019, 41, 96–107. [Google Scholar] [CrossRef]
- Bishop, C.; Jarvis, P.; Turner, A.; Balsalobre-Fernandez, C. Validity and Reliability of Strategy Metrics to Assess Countermovement Jump Performance Using the Newly Developed My Jump Lab Smartphone Application. J. Hum. Kinet. 2022, 83, 185–195. [Google Scholar] [CrossRef]
- Tan, E.C.H.; Weng Onn, S.; Montalvo, S. Measuring Vertical Jump Height With Artificial Intelligence Through a Cell Phone: A Validity and Reliability Report. J. Strength Cond. Res. 2024, 38, e529–e533. [Google Scholar] [CrossRef]
- Haynes, T.; Bishop, C.; Antrobus, M.; Brazier, J. The validity and reliability of the my jump 2 app for measuring the reactive strength index and drop jump performance. J. Sports Med. Phys. Fit. 2019, 59, 253–258. [Google Scholar] [CrossRef]
- Brooks, E.R.; Benson, A.C.; Bruce, L.M. Novel Technologies Found to be Valid and Reliable for the Measurement of Vertical Jump Height With Jump-and-Reach Testing. J. Strength Cond. Res. 2018, 32, 2838–2845. [Google Scholar] [CrossRef] [PubMed]
- Şentürk, D.; Yüksel, O.; Akyildiz, Z. The concurrent validity and reliability of the My Jump Lab smartphone app for the real-time measurement of vertical jump performance. Proc. Inst. Mech. Eng. Part P J. Sports Eng. Technol. 2024, 239, 559–566. [Google Scholar] [CrossRef]
- Rogers, S.A.; Hassmén, P.; Hunter, A.; Alcock, A.; Crewe, S.T.; Strauts, J.A.; Gilleard, W.L.; Weissensteiner, J.R. The Validity and Reliability of the MyJump2 Application to Assess Vertical Jumps in Trained Junior Athletes. Meas. Phys. Educ. Exerc. Sci. 2019, 23, 69–77. [Google Scholar] [CrossRef]
- Balsalobre-Fernández, C.; Romero-Franco, N.; Jiménez-Reyes, P. Concurrent validity and reliability of an iPhone app for the measurement of ankle dorsiflexion and inter-limb asymmetries. J. Sports Sci. 2019, 37, 249–253. [Google Scholar] [CrossRef]
- Balsalobre-Fernández, C.; Marchante, D.; Muñoz-López, M.; Jiménez, S.L. Validity and reliability of a novel iPhone app for the measurement of barbell velocity and 1RM on the bench-press exercise. J. Sports Sci. 2018, 36, 64–70. [Google Scholar] [CrossRef] [PubMed]
- Stojiljković, N.; Stanković, D.; Pelemiš, V.; Čokorilo, N.; Olanescu, M.; Peris, M.; Suciu, A.; Plesa, A. Validity and reliability of the My Jump 2 app for detecting interlimb asymmetry in young female basketball players. Front. Sports Act. Living 2024, 6, 1362646. [Google Scholar] [CrossRef] [PubMed]
- Wirtz, S.; Julian, R.; Schmale, R.; Eils, E. Concurrent Validity and Reliability of In-Field Vertical Jump Performance Measures on Sand Surfaces. J. Strength Cond. Res. 2024, 38, 687–693. [Google Scholar] [CrossRef] [PubMed]
- Stanton, R.; Wintour, S.A.; Kean, C.O. Validity and intra-rater reliability of MyJump app on iPhone 6s in jump performance. J. Sci. Med. Sport 2017, 20, 518–523. [Google Scholar] [CrossRef]
- Wang, Y.; Wang, X.; Luan, C.; Shan, W.; Gong, L. The validity and reliability of the My Jump 2 app for measuring vertical stiffness in male college players. Front. Sports Act. Living 2024, 6, 1405118. [Google Scholar] [CrossRef]
- Whiteley, I.; Sideris, V.; Kotsifaki, R.; King, E.; Whiteley, R. The MyJump App is a Valid Method of Assessing and Classifying Limb Symmetry During Recovery from Anterior Cruciate Ligament Reconstruction. Int. J. Sports Phys. Ther. 2023, 18, 1156–1165. [Google Scholar] [CrossRef]
- Hopkins, W.G. Measures of Reliability in Sports Medicine and Science. Sports Med. 2000, 30, 1–15. [Google Scholar] [CrossRef] [PubMed]
- Bishop, C.; Shrier, I.; Jordan, M. Ratio Data: Understanding Pitfalls and Knowing When to Standardise. Symmetry 2023, 15, 318. [Google Scholar] [CrossRef]
- Bishop, C.; Perez-Higueras Rubio, M.; Gullon, I.L.; Maloney, S.; Balsalobre-fernandez, C. Jump and Change of Direction Speed Asymmetry Using Smartphone Apps: Between-Session Consistency and Associations with Physical Performance. J. Strength Cond. Res. 2020, 36, 927–934. [Google Scholar] [CrossRef] [PubMed]


| Force Platform | My Jump Lab | |||
|---|---|---|---|---|
| CV (95% CI) | ICC (95% CI) | CV (95% CI) | ICC (95% CI) | |
| Jump height (m) | 6.5 (4.8–8.3) | 0.870 (0.840–0.896) | 6.9 (5.0–8.7) | 0.851 (0.817–0.881) |
| Contact time (s) | 7.0 (5.2–8.9) | 0.705 (0.646–0.759) | 5.8 (4.3–7.4) | 0.705 (0.648–0.761) |
| DRI | 12.8 (9.3–16.2) | 0.817 (0.776–0.852) | 11.5 (8.5–14.6) | 0.810 (0.768–0.847) |
| Force Platform (Mean ± SD) | My Jump Lab (Mean ± SD) | Bias (LoA) | RMSE | Pearson r | CCC (95% CI) | ICC (95% CI) | |
|---|---|---|---|---|---|---|---|
| Jump height (m) | 0.244 ± 0.043 | 0.228 ± 0.042 | −0.016 (−0.007, −0.025) | 0.005 | 0.994 | 0.932 (0.911, 0.949) | 0.994 (0.992, 0.996) |
| Contact time (s) | 0.208 ± 0.034 | 0.221 ± 0.033 | 0.014 (0.003, 0.024) | 0.006 | 0.987 | 0.948 (0.930, 0.962) | 0.987 (0.983, 0.990) |
| DRI | 1.267 ± 0.434 | 1.241 ± 0.391 | −0.026 (−0.211, 0.159) | 0.08 | 0.979 | 0.978 (0.971, 0.984) | 0.974 (0.965, 0.980) |
| Device | Day 1 (Mean ± SD) | Day 2 (Mean ± SD) | ICC (95%CI) | CV (95%CI) | |
|---|---|---|---|---|---|
| Jump height (m) | Force platform | 0.236 ± 0.046 | 0.260 ± 0.038 | 0.925 (0.756–0.977) | 8.0 (5.8–10.2) |
| My Jump Lab | 0.220 ± 0.045 | 0.239 ± 0.036 | 0.825 (0.426–0.947) | 10.4 (7.6–13.2) | |
| Contact time (s) | Force platform | 0.215 ± 0.024 | 0.205 ± 0.028 | 0.889 (0.635–0.966) | 5.8 (4.3–7.3) |
| My Jump Lab | 0.229 ± 0.024 | 0.211 ± 0.029 | 0.869 (0.569–0.960) | 7.2 (5.3–9.1) | |
| DRI | Force platform | 1.136 ± 0.305 | 1.343 ± 0.451 | 0.901 (0.677–0.970) | 12.8 (9.4–16.3) |
| My Jump Lab | 1.112 ± 0.261 | 1.407 ± 0.432 | 0.847 (0.499–0.953) | 16.1 (11.8–20.4) |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Share and Cite
Balsalobre-Fernández, C. Smartphone-Based Assessment of the Stretch–Shortening Cycle: Validity and Reliability of the My Jump Lab App for Measuring the Dynamic Rebound Index. Sensors 2026, 26, 3068. https://doi.org/10.3390/s26103068
Balsalobre-Fernández C. Smartphone-Based Assessment of the Stretch–Shortening Cycle: Validity and Reliability of the My Jump Lab App for Measuring the Dynamic Rebound Index. Sensors. 2026; 26(10):3068. https://doi.org/10.3390/s26103068
Chicago/Turabian StyleBalsalobre-Fernández, Carlos. 2026. "Smartphone-Based Assessment of the Stretch–Shortening Cycle: Validity and Reliability of the My Jump Lab App for Measuring the Dynamic Rebound Index" Sensors 26, no. 10: 3068. https://doi.org/10.3390/s26103068
APA StyleBalsalobre-Fernández, C. (2026). Smartphone-Based Assessment of the Stretch–Shortening Cycle: Validity and Reliability of the My Jump Lab App for Measuring the Dynamic Rebound Index. Sensors, 26(10), 3068. https://doi.org/10.3390/s26103068
