Next Article in Journal
MDAPT: Multi-Modal Depth Adversarial Prompt Tuning to Enhance the Adversarial Robustness of Visual Language Models
Previous Article in Journal
Reducing Cross-Sensor Domain Gaps in Tactile Sensing via Few-Sample-Driven Style-to-Content Unsupervised Domain Adaptation
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Validity Identification and Rectification of Water Surface Fast Fourier Transform-Based Space-Time Image Velocimetry (FFT-STIV) Results

1
College of Information Science and Engineering, Hohai University, Changzhou 213200, China
2
Key Laboratory of Hydrologic-Cycle and Hydrodynamic-System of Ministry of Water Resources, Nanjing 210024, China
*
Author to whom correspondence should be addressed.
Sensors 2025, 25(1), 257; https://doi.org/10.3390/s25010257
Submission received: 15 November 2024 / Revised: 19 December 2024 / Accepted: 3 January 2025 / Published: 5 January 2025
(This article belongs to the Section Sensing and Imaging)

Abstract

Fast Fourier Transform-based Space-Time Image Velocimetry (FFT-STIV) has gained considerable attention due to its accuracy and efficiency. However, issues such as false detection of MOT and blind areas lead to significant errors in complex environments. This paper analyzes the causes of FFT-STIV gross errors and then proposes a method for validity identification and rectification of FFT-STIV results. Three evaluation indicators—symmetry, SNR, and spectral width—are introduced to filter out invalid results. Thresholds for these indicators are established based on diverse and complex datasets, enabling the elimination of all erroneous velocities while retaining 99.83% of valid velocities. The valid velocities are then combined with the distribution law of section velocity to fit the velocity curve, rectifying invalid results and velocities in blind areas. The proposed method was tested under various water levels, weather conditions, and lighting scenarios at the Panzhihua Hydrological Station. Results demonstrate that the method effectively identifies FFT-STIV results and rectifies velocities in diverse environments, outperforming FFT-STIV and achieving a mean relative error (MRE) of less than 8.832% within 150 m. Notably, at night with numerous invalid STIs at a distance, the proposed method yields an MRE of 4.383% after rectification, outperforming manual labeling.
Keywords: river surface velocity; STIV; FFT; validity identification; velocity rectification river surface velocity; STIV; FFT; validity identification; velocity rectification

Share and Cite

MDPI and ACS Style

Zhang, Z.; Chen, L.; Yuan, Z.; Gao, L. Validity Identification and Rectification of Water Surface Fast Fourier Transform-Based Space-Time Image Velocimetry (FFT-STIV) Results. Sensors 2025, 25, 257. https://doi.org/10.3390/s25010257

AMA Style

Zhang Z, Chen L, Yuan Z, Gao L. Validity Identification and Rectification of Water Surface Fast Fourier Transform-Based Space-Time Image Velocimetry (FFT-STIV) Results. Sensors. 2025; 25(1):257. https://doi.org/10.3390/s25010257

Chicago/Turabian Style

Zhang, Zhen, Lin Chen, Zhang Yuan, and Ling Gao. 2025. "Validity Identification and Rectification of Water Surface Fast Fourier Transform-Based Space-Time Image Velocimetry (FFT-STIV) Results" Sensors 25, no. 1: 257. https://doi.org/10.3390/s25010257

APA Style

Zhang, Z., Chen, L., Yuan, Z., & Gao, L. (2025). Validity Identification and Rectification of Water Surface Fast Fourier Transform-Based Space-Time Image Velocimetry (FFT-STIV) Results. Sensors, 25(1), 257. https://doi.org/10.3390/s25010257

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop