Next Article in Journal
Development and Optimization of a Novel Soft Sensor Modeling Method for Fermentation Process of Pichia pastoris
Next Article in Special Issue
Human Activity Prediction Based on Forecasted IMU Activity Signals by Sequence-to-Sequence Deep Neural Networks
Previous Article in Journal
Smart Preventive Maintenance of Hybrid Networks and IoT Systems Using Software Sensing and Future State Prediction
Previous Article in Special Issue
Shoulder Range of Motion Measurement Using Inertial Measurement Unit—Validation with a Robot Arm
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Cervical Range of Motion Assessment through Inertial Technology: A Validity and Reliability Study

1
Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy
2
Istituto Auxologico Italiano, IRCCS, San Giuseppe Hospital, 28824 Piancavallo, Italy
*
Author to whom correspondence should be addressed.
Sensors 2023, 23(13), 6013; https://doi.org/10.3390/s23136013
Submission received: 10 April 2023 / Revised: 14 June 2023 / Accepted: 27 June 2023 / Published: 28 June 2023
(This article belongs to the Special Issue IMU Sensors for Human Activity Monitoring)

Abstract

Inertial technology has spread widely for its comfortable use and adaptability to various motor tasks. The main objective of this study was to assess the validity of inertial measurements of the cervical spine range of motion (CROM) when compared to that of the optoelectronic system in a group of healthy individuals. A further aim of this study was to determine the optimal placement of the inertial sensor in terms of reliability of the measure, comparing measurements obtained from the same device placed at the second cervical vertebra (C2), the forehead (F) and the external occipital protuberance (EOP). Twenty healthy subjects were recruited and asked to perform flexion–extension, lateral bending, and axial rotation movements of the head. Outcome measurements of interest were CROM and mean angular velocities for each cervical movement. Results showed that inertial measurements have good reliability (0.75 < ICC < 0.9). Excellent reliability (ICC > 0.9) was found in both flexion and right lateral bending angles. All parameters extracted with EOP placement showed ICC > 0.62, while ICC < 0.5 was found in lateral bending mean angular velocities both for F and C2 placements. Therefore, the optimal sensor’s positioning emerged to be EOP. These results suggest that inertial technology could be useful and reliable for the evaluation of the CROM.
Keywords: cervical spine; CROM; inertial sensor; validation; reliability cervical spine; CROM; inertial sensor; validation; reliability

Share and Cite

MDPI and ACS Style

Palmieri, M.; Donno, L.; Cimolin, V.; Galli, M. Cervical Range of Motion Assessment through Inertial Technology: A Validity and Reliability Study. Sensors 2023, 23, 6013. https://doi.org/10.3390/s23136013

AMA Style

Palmieri M, Donno L, Cimolin V, Galli M. Cervical Range of Motion Assessment through Inertial Technology: A Validity and Reliability Study. Sensors. 2023; 23(13):6013. https://doi.org/10.3390/s23136013

Chicago/Turabian Style

Palmieri, Martina, Lucia Donno, Veronica Cimolin, and Manuela Galli. 2023. "Cervical Range of Motion Assessment through Inertial Technology: A Validity and Reliability Study" Sensors 23, no. 13: 6013. https://doi.org/10.3390/s23136013

APA Style

Palmieri, M., Donno, L., Cimolin, V., & Galli, M. (2023). Cervical Range of Motion Assessment through Inertial Technology: A Validity and Reliability Study. Sensors, 23(13), 6013. https://doi.org/10.3390/s23136013

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop