Next Article in Journal
Denial-of-Service Attack on IEC 61850-Based Substation Automation System: A Crucial Cyber Threat towards Smart Substation Pathways
Previous Article in Journal
Validation of the Apple Watch for Estimating Moderate-to-Vigorous Physical Activity and Activity Energy Expenditure in School-Aged Children
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Communication

A Novel Transfer Function Based Ring-Down Suppression System for PMUTs

1
The Institute of Technological Sciences, Wuhan University, Wuhan 430072, China
2
The Shanghai Industrial μTechnology Research Institute, Shanghai 201899, China
*
Authors to whom correspondence should be addressed.
Sensors 2021, 21(19), 6414; https://doi.org/10.3390/s21196414
Submission received: 7 August 2021 / Revised: 13 September 2021 / Accepted: 17 September 2021 / Published: 25 September 2021
(This article belongs to the Section Physical Sensors)

Abstract

:
In this paper, a novel ring-down suppression system based on transfer function is proposed for the first time to suppress the ring-down time and decrease the blind area of PMUTs (Piezoelectric Micromachined Ultrasonic Transducers). This suppression system includes a transfer function and a simple P (proportion) controller, which can reduce the ring-down time without degrading any performances of PMUTs. The transfer function serves as a virtual PMUT device, feeding its output into the P controller; then, the P controller generates a suppression signal to the actual PMUT device. The ring-down time of a 115-kHz PMUT array is demonstrated to be reduced by up to 93% through the suppression system. In addition, the P controller has been experimentally optimized, reducing the blind area of the PMUT array by about 40%. Moreover, a low ring-down PMUTs system design guideline is established, which is practical and straightforward for industrial scenarios. Finally, the system can be easily integrated into ASIC (Application Specific Integrated Circuit).

1. Introduction

Ultrasonic transducers have been widely used for rangefinders, especially at short (<10 m) distances, since the relatively low speed of sound alleviates the high-speed electronics requirements [1,2,3]. PMUTs (Piezoelectric Micromachined Ultrasonic Transducers) are particularly attractive in applications requiring multiple transducers for range finding due to their small size and low power consumption. Besides, PMUTs work without DC bias and can be compatible with the complementary metal-oxide-semiconductor (CMOS) fabrication process.
When the PMUTs based ultrasonic sensor works in pulse-echo mode, the transmitter generates the pulse signal, and the echo signal is caught by the receiver, as shown in Figure 1a. Then the distance can be obtained through the difference between the arrival time of the echo signal and the emission time of the pulse signal (Time of flight, TOF). When the excitation signal is removed, the PMUTs continue to vibrate due to mechanical inertia called the ring-down vibration or “tailing” [4], as shown in Figure 1b. During the ring-down stage, the echo signal will be affected by the ring-down vibration of the PMUTs, such as overlapped or distortion, which fails to distinguish the echo signal and TOF [4,5]. In pulse-echo mode, the first echo signal that can be received must arrive later than the end of pulse signal transmission. The duration of the pulse signal is the blind area for PMUTs. The ring-down vibration is the main cause of the blind area for PMUTs. The PMUTs generally have lower bandwidth and higher quality factor (Q) than bulk piezoelectric transducers and Capacitance Micromachined Ultrasonic Transducers (CMUTs), which results in longer ring-down time and more unsatisfactory performance in practical applications [5,6,7,8,9,10,11]. Suppression of ring-down vibration can reduce the blind area and improve the ranging distance of the PMUTs.
At present, many efforts have been made to reduce the ring-down time or blind area of ultrasonic transducers, such as full-bridge acoustic emission [4], parallel resistors [12,13], Golay complementary pairs [14], amplitude detection [15], etc. The above methods are usually verified using bulk piezoelectric transducers, not PMUTs with much smaller bandwidth and higher Q. Yao et al. [4] proposed a full bridge acoustic emission technique based on bootstrap gate driver (BGD) and metal-oxide-semiconductor field-effect transistor (MOSFET). When the excitation signal is removed, the full-bridge acoustic emission technique quickly consumes the residual energy. Chang et al. [12,13] suggested a parallel resistor to reduce DC time constant and DC response time of the transient response, induced immediately after an AC voltage connected to a bolt-clamped Langevin transducer (BLT). The above methods [4,12,13] are effective by increasing the complexity of the peripheral circuit. Hernández et al. [14] presented an encoding technique based on Golay complementary pairs, where the dimension of the blind zone is reduced to negligible distances using specially designed features from the binary sequences. The encoding technique is not suitable for PMUTs due to its small bandwidth. Few methods have been proposed to reduce the ring-down of PMUTs and can be generally divided into two categories: suppression system design [16,17,18] and device structure modification [19,20]. Liu et al. [16,17] proposed a phase shift method to reduce the ring-down of PMUTs, and the optimized ring-down time accounts for less than 15.1% of the natural ring-down time in the air. Pala et al. [18] proposed optimizing the duration of the inverse signal in the phase-shift cancellation scheme. The results show that the ring-down time is shortened by 13% and 7.5% for a single element and the 80-element array, respectively. Kusano et al. [19,20] reported the effects using DC-biased lead-zirconate-titanate (PZT) PMUTs, in which the polarization and stress are controlled accordingly. At the optimal bias voltage, the (1,1) mode and (1,3) mode nearly overlap, increasing the bandwidth by a factor of eight and decreasing the ring-down time by about 82% relative to the zero DC-biased state. Modifying the device structure will change characteristics of PMUTs, and usually involves much fabrication-related work. Suppression system design will not affect the PMUTs design and their fabrication. It is worth noting that the existing suppression systems are sensitive to system parameters.
To suppress ring-down time and decrease blind area of PMUTs, a novel ring-down suppression system based on PMUTs’ transfer function with a simple P (proportion) controller is proposed in this paper. The transfer function serves as a virtual PMUT device, feeding its output into the P controller; then, the P controller will generate a suppression signal to the actual PMUT device. The suppression system only works on the ring-down stage, which will not impact the performances of PMUTs. Moreover, this approach proves a significant suppression effect and is insensitive to system parameters. A 93% ring-down time reduction is demonstrated experimentally using a 115-kHz PMUT array, and its blind area is reduced by about 40% after optimizing the P controller. Compared with the prior art, this suppression system provides a common solution, proving good stability and straightforward operation with minimum complexity of peripheral circuits. Moreover, design guidelines have been extracted for the suppression system as well. This work demonstrates an effective method of reducing blind area and improving ranging distance, which can be applied to a wide spectrum of applications, including short distance rangefinder, gesture identification, ultrasonic proximity sensing skin, etc.

2. Structure and Characterizations of PMUTs

The PMUTs are fabricated on SOI (Silicon on Insulator) wafer. As shown in Figure 2a, the PMUTs are comprised of a thin film Aluminum Nitride (AlN) piezoelectric layer sandwiched between two molybdenum (Mo) electrodes and a Silicon (Si) passive layer. The corresponding geometric parameters of the PMUTs are summarized in Table 1. As shown by the optical microscopic image (Figure 2b), the PMUT array comprises 9 (3 × 3) independent PMUTs. Because of the piezoelectric effect of AlN, this structure can transform electrical energy into acoustic energy and vice versa. Specifically, when applying an appropriate AC signal to the top and bottom electrodes, the transverse internal stress produced by the AlN layer will make the diaphragm vibrate and generate ultrasonic waves. Conversely, the electrodes will detect electronic signals when ultrasonic waves hit the diaphragm.
The process flow of the PMUT array is shown in Figure 2c–h [21]. (c) Customize a single-side polishing SOI wafer. (d) Multiple layers of the bottom Mo electrode, AlN layer, and top Mo electrode are sputtered on the SOI wafer. (e) The top Mo electrode is patterned by plasma etching, and an oxide layer is deposited to form the isolation layer. (f) The etching of SiO2 and AlN follows it to pattern the via opening for the top and bottom electrodes. (g) The Aluminum (Al) leads and bonding pads are subsequently deposited and patterned. (h) The deep reactive ion etching (DRIE) is conducted from the backside of the SOI wafer to release the patterned membrane. The whole process is completed at Shanghai Industrial μTechnology Research Institute (SITRI).
The resonant frequency and mode shape are characterized using a Laser Doppler Vibrometer (LDV, Polytec UHF-120). The measurement results of 9 independent PMUTs in the PMUT array are shown in Figure 3. The multilayer structure of PMUTs inevitably suffers from frequency variation, which is highly processed dependent. As shown in Figure 3a, a change in the resonant frequency is clearly observed. Although there is a frequency variation in the PMUT array, the bandwidth of all elements overlaps, mostly. Moreover, the resonance frequency of the central element can be used to represent the resonance frequency of the PMUT array. According to the measurement results, the 1st resonance frequency of the central element is about 115kHz; the −3dB bandwidth is 0.908kHz, the Q is 126.65, and the displacement sensitivity of the central point is 13.2 nm/Vpp.

3. Design of The Suppression System

3.1. Transfer Function of PMUTs

The PMUTs are a spring-mass-damper-piezo model, as shown in Figure 4 [16,22,23,24,25]. In this model, the PMUTs consist of a mass with lumped mass M, a damper with a damping coefficient of bm, a spring with a spring coefficient of Km, and a piezoelectric element. wb(t) is the displacement due to the piezoelectric effect, and w(t) is the displacement output by the model. The piezoelectric element is connected to the drive circuit, and a load R is directly connected to the piezoelectric element. The voltage at the ends is V(t). The dynamic equation of the above model is:
M w ¨ ( t ) + b m w ˙ ( t ) + K m w ( t ) + Θ b c V ( t ) = M w ¨ b ( t )
where ΘbcV(t) denotes the piezoelectric coupling force generated by voltage V(t), Θbc denotes the backward coupling constant. According to the e-type piezoelectric equation, the relationship between V(t) and wb(t) can be expressed as:
C p e V ˙ ( t ) + V ( t ) R Θ f c w ˙ b ( t ) = 0
where Cpe denotes the effective capacitance between the top and bottom electrodes, Θfc denotes the forward coupling constant.
One could obtain Equations (3) and (4) by performing Laplace transform on Equations (1) and (2), respectively,
w ( s ) ( M s 2 + b m s + K m ) + Θ b c V ( s ) = w b ( s ) M s 2
C p e s V ( s ) + V ( s ) R Θ f c s w b ( s ) = 0
Then the transfer function of the excitation signal to the displacement of PMUTs can be expressed as:
H ( s ) = M C p e Θ f c s 2 + M Θ f c R s + Θ b c M s 2 + b m s + K m
It could be seen from Equation (5), the PMUTs are a second-order system with 2-zeros and 2-poles.

3.2. The Theory of the Suppression System

One could obtain the Dynamic equation of PMUTs through Equations (1) and (2).
w ¨ ( t ) + b m M w ˙ ( t ) + K m M w ( t ) = C p e Θ f c V ¨ ( t ) + 1 Θ f c R V ˙ ( t ) Θ b c M V ( t )
When the excitation signal is removed, the PMUTs are in the free vibration stage and V(t) = 0. Then, Equation (6) can be converted to:
w ¨ ( t ) + b m M w ˙ ( t ) + K m M w ( t ) = 0
The solution of Equation (7) is:
w = A 0 e β e t cos ( ω 0 2 β e 2 t + φ 0 )
where A0 denotes the initial displacement of the PMUTs, ω 0 2 = K m / M , 2 β e = b m / M .
When the excitation signal is removed, the PMUTs are excited by an additional excitation signal. The same cosine signal as the free vibration stage with a negative proportional parameter is used as the additional excitation signal, which is set as V ( t ) = V 0 cos ( ω e t + φ v ) . Then, Equation (6) can be expressed as:
w ¨ ( t ) + b m M w ˙ ( t ) + K m M w ( t ) = F 0 cos ( ω e t + φ )
where
F 0 = A V 2 + B V 2 ,   φ = φ V + arctan A V B V + π 2
A V = C p e ω e 2 V 0 Θ f c + Θ b c M V 0 ,   B V = ω e V 0 Θ f c R
The solution of Equation (9) is:
w = A 0 e β e t cos ( ω 0 2 β e 2 t + φ 0 ) A F cos ( ω e t + φ )
where
A F = F 0 M ( ω 0 2 ω e 2 ) 2 + 4 β e 2 ω e 2 , tan φ 0 = 2 β e ω e ω 0 2 ω e 2
It could be seen from Equation (10), A 0 e β e t cos ( ω 0 2 β e 2 t + φ 0 ) is the free vibration displacement of the PMUTs when the excitation signal is removed and A F cos ( ω e t + φ ) is the additional attenuation term of the PMUTs displacement. The additional excitation signal generates the additional attenuation term. The above analysis shows that the suppression signal is generated by the reference signal with a specific gain for the ring-down vibration.

3.3. The Design of the Suppression System

According to the above theory, the ring-down signal can be used as a reference signal, and the ring-down vibration of PMUTs can be reduced through the reference signal with a specific gain. Then the suppression system based on the transfer function of PMUTs is designed, illustrated in Figure 5. The suppression system consists of the transfer function of PMUTs and a P controller. The transfer function of PMUTs serves as a virtual PMUT device and generates the virtual ring-down vibration signal. Since the object value of the controller is 0, the input error signal of the P controller is the same as the virtual ring-down vibration signal. Then the P controller outputs the suppression signal of ring-down vibration to the actual PMUT device by multiplying the virtual ring-down vibration signal through the proportional parameter. The switch isolates the input excitation signal and the suppression signal of ring-down vibration to avoid the influence of the suppression system on the echo signal. The mixed input signal finally applied to the actual PMUT device is divided into the input excitation signal and the suppression signal through the switch. Moreover, the proposed system suppresses the ring-down time of PMUTs in a controlled manner and has no impact on the performances of PMUTs.
Due to the high resonance frequency of PMUTs, the hardware requirements to implement the real-time system is high if the ring-down signal of real PMUTs is used to feedback into the P controller. Therefore, the transfer function of PMUTs is used as a model to predict the vibration of PMUTs. The transfer function of PMUTs is obtained through the system identification in the toolbox of MATLAB since the transfer function of PMUTs obtained from Equation (5) is very difficult. The controller is the core to generate the suppression signal of ring-down vibration. Since the theory in Section 3.2. can be implemented through a basic P controller, the P controller is chosen as a start to verify the proposed suppression system. The proportional parameter of the P controller depends on the actual scenarios, which can control the ring-down time or blind area of PMUTs. The suppression signal is calculated through MATLAB, and it always attenuates with time. Thus, the mixed input signal provides limited energy. In the meantime, the PMUTs are passive devices. In such a case, the stability of the P controller-based system can be guaranteed.
Moreover, a low ring-down PMUTs system design guideline is also proposed based on the suppression system. Firstly, the transfer function is obtained through the measurement results in the actual environment. Then, the suppression system is designed and attached to the PMUTs based sensors. The system does not need many calculation resources and is easy to integrate into ASIC (Application Specific Integrated Circuit). In addition, since the influence of actual environmental conditions on the PMUTs is included in the transfer function, the proposed suppression system has the ability to accommodate the changing environment.

4. Results and Analysis

Experiments are conducted to verify the performances of the suppression system. The 115-kHz 3 × 3 PMUT array shown in Figure 2b is utilized as an experimental device. Firstly, the vibration signal of the PMUT array is obtained through LDV. Moreover, the transfer function of the PMUT array can be gutted through system identification. Then, the suppression system is implemented in MATLAB/Simulink, while the suppression signal of ring-down vibration can be generated simultaneously. Finally, the mixed input signal is used to excite the PMUT array through a waveform generator to verify the effectiveness of the suppression system.

4.1. Experimental Setup

The vibration displacement of the PMUT array is characterized using LDV. The measurement setup is shown in Figure 6. The excitation signals are generated using a waveform generator (KEYSIGHT 33600A or JDS2800). The raw signal from the photodetector is collected with an oscilloscope (WaveRunner 8254M). Furthermore, the in-phase quadrature (IQ) vibrational data is demodulated, and the mode shape is presented on a controlling personal computer (PC) using Polytec PSV 9.4.1 software.
The acoustic characteristics are measured by a microphone, as shown in Figure 7. The PMUT array is placed at the center of the rotary lifting platform. During measurement, the PMUT array is excited by a waveform generator. Ultrasound wave generated by the PMUT array is measured using a microphone (B&K Type 4138-L-006) connected to a signal conditioning amplifier (B&K Type 1708). The microphone is placed in a metal clamp 20 cm away from the devices. Moreover, the corresponding output signal is recorded and displayed by an oscilloscope (KEYSIGHT DSOX2014A).

4.2. Experiment of the Transfer Function

The system identification results are shown in Table 2 through the input excitation signal and the vibration signals of the central point of the central element in the PMUT array. The input excitation signal is a 115-kHz sine signal of 20 cycles with an amplitude of 1Vpp. The transfer function of the PMUT array is obtained by the 0-zero and 2-pole second-order system (0-2) model, the 1-2 model, the 2-2 model, the 0-3 model, the 1-3 model, the 2-3 model, the 3-3 model respectively. The FED (Fit to estimation data) is the degree of fit between the objective transfer function and the result of the system identification. The 2-2 model has the best FED, consistent with the above theory in Section 3. The FED of the PMUT array cannot reach a high value since the inevitably a mutual influence between the elements of the PMUT array [26]. This nonlinear influence cannot be described by the linear transfer function of the PMUT array. The FED can be improved if the experimental device is a single PMUT. In practical application, the PMUTs are always an array due to the inferior output of a single element. At the same time, the FED of the transfer function based on the 2-2 model is also high (>80%) enough to describe the characterize the vibration of PMUTs. Therefore, the transfer function based on the 2-2 model is used for the suppression system.

4.3. Verification of the Suppression System on Reducing the Ring-Down Time and Blind Area

The suppression signal of ring-down vibration is calculated through MATLAB/Simulink under different proportional parameters (k) set as 0, 1, 2, 3, 5, 10, respectively (k = 0/1/2/3/5/10). When k = 1, the amplitude of the suppression signal is close to the value of the excitation signal. When k = 0, the situation is without the suppression system. The input excitation signal is also a 115-kHz sine signal of 20 cycles with an amplitude of 1Vpp. The processing time at different k values in MATLAB/Simulink is about 0.5s. The mixed input signal under different proportional parameters is illustrated in Figure 8a. The amplitude of the suppression signal increases as the proportional parameter.
The vibration displacement of the PMUT array under different proportional parameters is measured through LDV, as shown in Figure 8b. The LDV measurements are also done at the central point of the central element in the PMUT array. The ring-down vibration is reduced significantly by the proposed suppression system, and the attenuation speed of ring-down vibration is faster when the proportional parameter is greater. As shown in Figure 8b, the maximum displacements are almost the same under the same excitation signal, though k are different. This proves that the suppression system has no effect on the sensitivity of the PMUT array. The ring-down time of PMUTs is defined as the time corresponding to 37% of the maximum displacement [16]. The ring-down time under different proportional parameters is calculated, as shown in Table 3. The ring-down time is reduced by up to 93% compared to the results without the suppression system. The “overshoot” refers to a phenomenon that the displacement envelope of PMUTs fluctuates around 0 for a period during the ring-down stage. It also can be seen from the measurement results that the central element in the PMUT array is “overshoot” during the ring-down stage when k > 2. As the discussion in Section 4.2., the linear transfer function cannot describe the nonlinear influence caused by the mutual influence between the elements of the PMUT array. The nonlinear influence results in an error between the ring-down vibration of the actual PMUT array and that predicted by the transfer function. This error has a great impact on the “overshoot” when k > 2. As shown in Figure 8b, the amplitudes of “overshoot” are below the threshold of the ring-down time when k > 2. Thus the ring-down time and the effectiveness of the proposed suppression system are not affected by the “overshoot”.
Due to the limitation of LDV, the microphone experiment is conducted to verify the performances of the suppression system in a typical input excitation signal on the PMUT array. The results are illustrated in Figure 8c. The input excitation signal of the microphone experiment is a 115-kHz sine signal of 20 cycles with an amplitude of 5Vpp. Since the ring-down vibration is suppressed, the blind area of the PMUT array is reduced. The results show that the proposed method is stable between the elements of the PMUT array and is effective for the whole PMUT array. In the short-distance ranging, since the distortion caused by ring-down greatly influences ranging accuracy, the threshold of the blind area should be as small as possible. Whereas in real applications, the noise of PMUTs receivers may also affect the ranging measurement. Considering the above factors, the threshold of the blind area is set as 5% of the maximum output of PMUTs in this study to ensure a decent and robust ranging coverage. The blind area is calculated under different proportional parameters, as shown in Table 4.
In Figure 8c, the trend with different proportional parameters is similar to Figure 8b, and the PMUT array is also “overshoot” during the ring-down stage when k > 2. Although the ring-down time is shorter when the proportional parameter is greater, the more significant proportional parameter will cause a stronger “overshoot,” affecting the blind area. Simultaneously, a larger proportional parameter will result in a larger amplitude of the suppression signal, damaging other circuits. Therefore, the optimal proportional parameter is a value that does not generate “overshoot” and does not generate a larger voltage. Then the optimal proportion parameter is 2 for the 115-kHz 3 × 3 PMUT array. The experimental microphone result of k = 2 is illustrated in Figure 8d. For the PMUT array, the blind area is 0.367ms when k = 2, and the blind area is 0.612ms when k = 0. The blind area with the suppression system is reduced by 40% relative to the blind area without the suppression system when k = 2.

5. Conclusion and Future Work

In this paper, a novel suppression system based on the transfer function of PMUTs is proposed to reduce the blind area of the PMUT array. The proposed system can suppress the ring-down time then decrease the blind area of the PMUT array effectively in a controlled manner. The ring-down time of a 115-kHz PMUT array is demonstrated to reduce by up to 93%. The optimal proportion parameter is derived as two for this PMUT array. Correspondingly, the blind area of the PMUT array is reduced by about 40% under the optimal condition. Moreover, a low ring-down PMUTs system design guideline is proposed based on the suppression system. Compared with the ultrasonic ranging systems in the prior art, this suppression system is insensitive to system parameters and has no impact on the performances of PMUTs. This approach is practical and straightforward to apply, especially when calculation resources are limited in practical industrial scenarios. Furthermore, this approach will be integrated into ASIC as the next step of work.

Author Contributions

Conceptualization, Z.W.; methodology, Z.W.; software, Z.W.; validation, Z.W. and Z.T.; formal analysis, Z.W.; investigation, Z.W.; resources, Z.W.; data curation, Z.W.; writing—original draft preparation, Z.W.; writing—review and editing, W.L., Z.T., S.Z., Y.G., G.W., A.T., L.L. and C.S.; visualization, Z.W.; supervision, L.L. and C.S. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Science and Technology Commission of Shanghai Municipality, grant number 19PJ1432300.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

The authors wish to thank the Shanghai Industrial μTechnology Research Institute (SITRI) for the device fabrication and experimental environment.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Przybyla, R.J.; Shelton, S.E.; Guedes, A.; Izyumin, I.I.; Kline, M.H.; Horsley, D.A.; Boser, B.E. In-air rangefinding with an aln piezoelectric micromachined ultrasound transducer. IEEE Sens. J. 2011, 11, 2690–2697. [Google Scholar] [CrossRef]
  2. Przybyla, R.; Izyumin, I.; Kline, M.; Boser, B.; Shelton, S.; Guedes, A.; Horsley, D. An ultrasonic rangefinder based on an AlN piezoelectric micromachined ultrasound transducer. In Proceedings of the 2010 IEEE Sensors Conference, Kona, HI, USA, 1–4 November 2010; pp. 2417–2421. [Google Scholar]
  3. Przybyla, R.J.; Shelton, S.E.; Guedes, A.; Krigel, R.; Horsley, D.A.; Boser, B.E. In-air ultrasonic rangefinding and angle estimation using an array of AlN micromachined transducers. In Proceedings of the Solid-State Sensors, Actuators and Microsystems Workshop, Hilton Head Island, SC, USA, 3–7 June 2012; pp. 3–7. [Google Scholar]
  4. Yao, Y.; Ju, X.; Lu, J.; Men, B. Acoustic emission and echo signal compensation techniques applied to an ultrasonic logging-while-drilling caliper. Sensors 2017, 17, 1351. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  5. Przybyla, R.J. Ultrasonic 3D rangefinder on a chip. In Doctor of Philosophy; University of California Berkeley: Berkeley, CA, USA, 2013. [Google Scholar]
  6. Roberto, M. Modeling and characterization of piezoelectric micromachined ultrasonic transducers (PMUT). In Master of Science; University of California Davis: Davis, CA, USA, 2019. [Google Scholar]
  7. Griffin, B.A.; Edstrand, A.M.; Yen, S.; Reger, R.W. Post-CMOS compatible piezoelectric micro-machined ultrasonic transducers. In Proceedings of the 2018 IEEE International Ultrasonics Symposium (IUS), Kobe, Japan, 22–25 October 2018; pp. 1–4. [Google Scholar]
  8. Lu, Y. Modeling, fabrication and characterization of piezoelectric micromachined ultrasonic transducer arrays. In Master of Science; University of California Davis: Davis, CA, USA, 2015. [Google Scholar]
  9. Jung, J.; Lee, W.; Kang, W.; Shin, E.; Ryu, J.; Choi, H. Review of piezoelectric micromachined ultrasonic transducers and their applications. J. Micromech. Microeng. 2017, 27, 11. [Google Scholar] [CrossRef]
  10. Muralt, P.; Baborowski, J. Micromachined ultrasonic transducers and acoustic sensors based on piezoelectric thin films. J. Electroceram. 2004, 12, 101–108. [Google Scholar] [CrossRef]
  11. Horsley, D.A.; Rozen, O.; Lu, Y.; Shelton, S.; Guedes, A.; Przybyla, R.; Tang, H.; Boser, B.E. Piezoelectric micromachined ultrasonic transducers for human-machine interfaces and biometric sensing. In Proceedings of the 2015 IEEE Sensors, Busan, Korea, 1–4 November 2015; pp. 1507–1510. [Google Scholar]
  12. Chang, K.T. Effects of a parallel resistor on electrical characteristics of a piezoelectric transformer in open-circuit transient state. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 2007, 54, 107–117. [Google Scholar] [CrossRef] [PubMed]
  13. Chang, K.T. Improving the transient response of a bolt-clamped Langevin transducer using a parallel resistor. Ultrasonics 2003, 41, 427–436. [Google Scholar] [CrossRef]
  14. Hernandez, A.; Urena, J.; Mazo, M.; Garcia, J.J.; Jimenez, A.; Alvarez, F.J. Reduction of blind zone in ultrasonic transmitter/receiver transducers. Sens. Actuator. A Phys. 2007, 133, 96–103. [Google Scholar] [CrossRef]
  15. Liu, Q.; Bai, P.; Luo, Z.; Zhang, W.; Zhou, G. Ultrasonic distance measuring system without blind area. In Proceedings of the 2016 IEEE International Conference on Signal and Image Processing (ICSIP), Beijing, China, 13–15 August 2016; pp. 626–629. [Google Scholar]
  16. Liu, X.; Chen, X.; Le, X.; Wang, Y.; Wu, C.; Xie, J. Reducing ring-down time of pMUTs with phase shift of driving waveform. Sens. Actuator. A Phys. 2018, 281, 100–107. [Google Scholar] [CrossRef]
  17. Liu, X.; Chen, X.; Le, X.; Xu, Z.; Wu, C.; Xie, J. Optimization of pMUTs driving waveform based on phase delay to reduce attenuation vibration. In Proceedings of the 2018 IEEE 13th Annual International Conference on Nano/Micro Engineered and Molecular Systems (NEMS), Singapore, 22–26 April 2018; pp. 582–585. [Google Scholar]
  18. Pala, S.; Shao, Z.; Peng, Y.; Lin, L. Improved ring-down time and axial resolution of PMUTs via a phase-shift excitation scheme. In Proceedings of the 34th IEEE International conference on micro electro mechanical systems, Gainesville, FL, USA, 25–29 January 2021; pp. 390–393. [Google Scholar]
  19. Kusano, Y.; Wang, Q.; Luo, G.; Lu, Y.; Rudy, R.Q.; Polcawich, R.G.; Horsley, D.A. Effects of DC bias tuning on air-coupled PZT piezoelectric micromachined ultrasonic transducers. J. Microelectromech. Syst. 2018, 27, 296–304. [Google Scholar] [CrossRef]
  20. Kusano, Y.; Wang, Q.; Rudy, R.Q.; Polcawich, R.G.; Horsley, D.A. Wideband air-coupled PZT piezoelectric micromachined ultrasonic transducer through dc bias tuning. In Proceedings of the 30th IEEE International Conference on Micro Electro. Mechanical Systems, Las Vegas, NV, USA, 22–26 January 2017; 1204–1207. [Google Scholar]
  21. Tong, Z.; Hu, H.; Wu, Z.; Xie, S.; Chen, G.; Zhang, S.; Lou, L.; Liu, H. An ultrasonic proximity sensing skin for robot safety control by using piezoelectric micromachined ultrasonic transducers (PMUTs). IEEE Sens. J. 2021. [Google Scholar]
  22. Jiang, X.; Tang, H.; Lu, Y.; Ng, E.J.; Tsai, J.M.; Boser, B.E.; Horsley, D.A. Ultrasonic fingerprint sensor with transmit beamforming based on a PMUT array bonded to CMOS circuitry. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 2017, 64, 1401–1408. [Google Scholar] [CrossRef] [PubMed]
  23. Sun, T.; Tasnim, F.; McIntosh, R.T.; Amiri, N.; Solav, D.; Anbarani, M.T.; Sadat, D.; Zhang, L.; Gu, Y.; Karami, M.A.; et al. Decoding of facial strains via conformable piezoelectric interfaces. Nat. Biomed. Eng. 2020, 4, 954–972. [Google Scholar] [CrossRef] [PubMed]
  24. Dutoit, N.E.; Wardle, B.L.; Kim, S.G. Design considerations for MEMS-scale piezoelectric mechanical vibration energy harvesters. Integr. Ferroelectr. 2005, 71, 121–160. [Google Scholar] [CrossRef]
  25. Lefeuvre, E.; Badel, A.; Richard, C.; Petit, L.; Guyomar, D. A comparison between several vibration-powered piezoelectric generators for standalone systems. Sens. Actuator. A-Phys. 2006, 126, 405–416. [Google Scholar] [CrossRef]
  26. Sina, A. Curved and bimorph piezoelectric micromachined ultrasonic transducers (PMUT). In Doctor of Philosophy; University of California Berkeley: Berkeley, CA, USA, 2016. [Google Scholar]
Figure 1. Illustration of (a) pulse-echo mode and (b) the cause of blind area.
Figure 1. Illustration of (a) pulse-echo mode and (b) the cause of blind area.
Sensors 21 06414 g001
Figure 2. The PMUT array: (a) cross-sectional view, (b) optical microscopic image, (c–h) process flow.
Figure 2. The PMUT array: (a) cross-sectional view, (b) optical microscopic image, (c–h) process flow.
Sensors 21 06414 g002
Figure 3. The resonant frequency and mode shape of (a) 9 independent PMUTs and (b) the central element in the PMUT array.
Figure 3. The resonant frequency and mode shape of (a) 9 independent PMUTs and (b) the central element in the PMUT array.
Sensors 21 06414 g003
Figure 4. The spring-mass-damper-piezo model of PMUTs.
Figure 4. The spring-mass-damper-piezo model of PMUTs.
Sensors 21 06414 g004
Figure 5. The suppression system based on the transfer function of PMUTs: (a) system architecture, (b) the input excitation signal, (c) the suppression signal of ring-down vibration, (d) the mixed input signal.
Figure 5. The suppression system based on the transfer function of PMUTs: (a) system architecture, (b) the input excitation signal, (c) the suppression signal of ring-down vibration, (d) the mixed input signal.
Sensors 21 06414 g005
Figure 6. Functional diagram of the LDV setup for vibration displacement.
Figure 6. Functional diagram of the LDV setup for vibration displacement.
Sensors 21 06414 g006
Figure 7. Schematic of microphone experimental setup.
Figure 7. Schematic of microphone experimental setup.
Sensors 21 06414 g007
Figure 8. The experimental result of the 115-kHz PMUT array under different k: (a) the mixed input signal, (b) the measurement result of LDV, (c) the measurement result of microphone, and (d) the measurement result of microphone under k = 2.
Figure 8. The experimental result of the 115-kHz PMUT array under different k: (a) the mixed input signal, (b) the measurement result of LDV, (c) the measurement result of microphone, and (d) the measurement result of microphone under k = 2.
Sensors 21 06414 g008aSensors 21 06414 g008b
Table 1. Geometric parameters of the PMUT array.
Table 1. Geometric parameters of the PMUT array.
MaterialTop MoAlNBottom MoSiSiO2Cavity
Radius (μm)700----1000
Thickness (μm)0.210.250.5400
Table 2. The system identification results.
Table 2. The system identification results.
ModelTransfer FunctionFED
0-2 H ( s ) = 4634 s 2 + 6529 s + 4.939 × 10 11 75.75%
1-2 H ( s ) = 0 . 001842 s + 4944 s 2 + 6210 s + 4.926 × 10 11 81.61%
2-2 H ( s ) = 1.222 × 10 9 s 2 + 0.0019 s + 5587 s 2 + 6227 s + 4.925 × 10 11 81.67%
0-3 H ( s ) = 1.202 × 10 10 s 3 + 2.392 × 10 6 s 2 + 5.072 × 10 11 s + 1.175 × 10 18 −24.73%
1-3 H ( s ) = 5130 s + 9.596 × 10 5 s 3 + 2.224 × 10 5 s 2 + 4.938 × 10 11 s + 1.065 × 10 17 81.52%
2-3 H ( s ) = 0.001872 s 2 + 4688 s 2.062 × 10 6 s 3 + 8486 s 2 + 4.925 × 10 11 s + 1.162 × 10 15 81.48%
3-3 H ( s ) = 6.229 × 10 9 s 3 + 0.001823 s 2 + 1581 s 4.896 × 10 6 s 3 + 8246 s 2 + 4.925 × 10 11 s + 1.062 × 10 15 81.5%
Table 3. The result of the ring-down time under different k.
Table 3. The result of the ring-down time under different k.
kExperiment (s)Reduction (dB)Relative Reduction (%)
04.1729 × 10−400
11.6769 × 10−4−3.959459.8150
21.0729 × 10−4−5.898974.2894
37.8487 × 10−5−7.256481.1911
54.9687 × 10−5−9.241988.0929
102.8087 × 10−5−11.713993.2692
Table 4. The result of the blind area under different k.
Table 4. The result of the blind area under different k.
kExperiment (s)Reduction (dB)Relative Reduction (%)
06.12 × 10−400
15.1 × 10−4−0.791816.6667
23.67 × 10−4−2.220940.0327
34.39 × 10−4−1.442928.2680
54.13 × 10−4−1.708032.5163
104.39 × 10−4−1.442928.2680
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Wu, Z.; Liu, W.; Tong, Z.; Zhang, S.; Gu, Y.; Wu, G.; Tovstopyat, A.; Sun, C.; Lou, L. A Novel Transfer Function Based Ring-Down Suppression System for PMUTs. Sensors 2021, 21, 6414. https://doi.org/10.3390/s21196414

AMA Style

Wu Z, Liu W, Tong Z, Zhang S, Gu Y, Wu G, Tovstopyat A, Sun C, Lou L. A Novel Transfer Function Based Ring-Down Suppression System for PMUTs. Sensors. 2021; 21(19):6414. https://doi.org/10.3390/s21196414

Chicago/Turabian Style

Wu, Zhipeng, Wenjuan Liu, Zhihao Tong, Songsong Zhang, Yuandong Gu, Guoqiang Wu, Alexander Tovstopyat, Chengliang Sun, and Liang Lou. 2021. "A Novel Transfer Function Based Ring-Down Suppression System for PMUTs" Sensors 21, no. 19: 6414. https://doi.org/10.3390/s21196414

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop