Review

Wearables for Industrial Work Safety: A Survey

1
Department of Telecommunications, Faculty of Electronics, Telecommunications and Information Technology, University Politehnica of Bucharest, 061071 Bucharest, Romania
2
Department of Telecommunications, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, 616 00 Brno, Czech Republic
3
Unit of Electrical Engineering, Faculty of Information Technology and Communication Sciences, Tampere University, 33720 Tampere, Finland
*
Author to whom correspondence should be addressed.
Sensors 2021, 21(11), 3844; https://doi.org/10.3390/s21113844
Submission received: 16 April 2021 / Revised: 27 May 2021 / Accepted: 27 May 2021 / Published: 2 June 2021
(This article belongs to the Special Issue Applications and Innovations on Sensor-Enabled Wearable Devices)

Abstract

:
Today, ensuring work safety is considered to be one of the top priorities for various industries. Workplace injuries, illnesses, and deaths often entail substantial production and financial losses, governmental checks, series of dismissals, and loss of reputation. Wearable devices are one of the technologies that flourished with the fourth industrial revolution or Industry 4.0, allowing employers to monitor and maintain safety at workplaces. The purpose of this article is to systematize knowledge in the field of industrial wearables’ safety to assess the relevance of their use in enterprises as the technology maintaining occupational safety, to correlate the benefits and costs of their implementation, and, by identifying research gaps, to outline promising directions for future work in this area. We categorize industrial wearable functions into four classes (monitoring, supporting, training, and tracking) and provide a classification of the metrics collected by wearables to better understand the potential role of wearable technology in preserving workplace safety. Furthermore, we discuss key communication technologies and localization techniques utilized in wearable-based work safety solutions. Finally, we analyze the main challenges that need to be addressed to further enable and support the use of wearable devices for industrial work safety.

1. Introduction

The workplace is fraught with many sources of danger, especially in enterprises with harmful work conditions. For a long time, the work safety issue has been relegated to the background by employers for the sake of labor productivity. Published by World Health Organization (WHO) [1], statistics on industrial death accidents from 1970 to the present day have a shape close to Gaussian. The lack of statistics can explain this observation since only six countries maintained such a base starting from the 70th. However, the emergence of new technologies, including wearable devices, can also contribute to constraining mortality in industries nowadays [2].
Although the number of accidents per year tends to decrease, the level of mortality in workplaces is still considerable. According to the International Labor Organization (ILO) [3], approximately 1.9 million people have work-related diseases, and 2.3 million people die from work accidents annually. Besides, these statistics reflect only reported cases: not all enterprises openly register all cases, thus, not entailing inspections, sanctions, unrest among staff, loss of reputation, etc. Therefore, at least 4.2 million people suffer in the workplace per year, and 45% of countries have a population less than this number [4].
The problem of work safety in industrial environments is still on the crest of a wave. Worldwide statistics show a high rate of death and injury at work, a variety of hazardous industries, and sources of danger [3]. With the advent of Industry 4.0 and broad integration of the Internet of Things (IoT), employers are expected to achieve better safety mainly due to the emergence of various technologies [5]. This paper is primarily focusing on the smallest form-factor personal devices, namely, wearables, that also attempt to achieve the same goal as part of the Internet of Wearable Things (IoWT) paradigm [6]. Further discussion will focus on the Industrial IoT (IIoT) that emerged to design, maintain, monitor, optimize, and analyze industrial operations to gain real-time insights, make effective decisions and maintain occupational safety [7,8].
Historically, the IIoT was at the initial stage of its development as of 2015 [9]. At this point, many entrepreneurs had doubts about the feasibility of introducing such an innovation due to the uncertainty about the impact that it will have on workers, labor processes, production, and, more importantly, profits. The situation has begun to change in the last five years. According to [7], the IIoT market size is estimated at 77 billion USD, with a perspective reaching 110 billion USD by 2025. However, this forecast was delivered before the spread of the COVID-19. Due to the global pandemic situation, many enterprises terminated their businesses or even claimed bankruptcy. Indirectly, we can estimate a decrease in production capacity by an increase in unemployment. For example, one of the most significant blows hit the manufacturing, construction, transportation, and storage sectors according to the UK statistics [10,11]. In contrast, some industrial wearable device manufacturers took advantage of the situation by adjusting products to the circumstances. For example, Estimote has redesigned its industrial wearable tracking devices to remember contacts between workers closer than two meters [11,12].
By meeting two basic requirements for any IoT device, namely, access to the Internet and communication solutions, wearables have become one of the most important IoT concepts, forming IoWT as a promising yet young segment. Various forecasts state that the wearable device market will reach 57 billion USD by 2022 [13], or even 64 billion USD by 2025 [14], and 104 billion USD by 2027 [15]. Wristbands and bracelets currently occupy the leading position among wearable devices and smartwatches, which market share is almost 50% [16].
As of today, research literature still lacks comprehensive reviews on wearable technology and its industrial utilization [17]. The most solid work considering this topic is [18]. In this paper, the authors distinguished 24 categories of wearable technologies and divided them into five groups depending on the functions; monitoring, tracking, augmenting, assisting, and delivering content. Moreover, they highlight six motivations behind the use of wearable devices in industrial environments: the ability to monitor employees’ psychological and physiological factors, enhance operational efficiency, promote work environment safety and security, and improve workers’ health. Finally, they revealed the main challenge groups compliant with the adoption of wearable devices; technological challenges (trade-off between size, weight, battery functions, accuracy, etc.), social challenges (confidentiality of data, lack of technical skills, high dependency on the wearable device), policies and standards set by governments, economic challenges (high cost of the wearable devices and its integration with other systems), and data challenges (data ownership issue, huge amount of data).
In particular, authors in [19] review wearable devices as part of the IoT concept, mentioning work safety in the list of areas where this technology is beneficial but without special focus on it. On the opposite, some other works explore the use of wearable devices in a narrow specific area of the industry. Moreover, the authors of [20] consider the mining industry, while work [21] deals with the construction industry. However, to the best of the author’s knowledge, none of these works investigates industrial wearables focusing on occupational safety or reviews key aspects of data collection, data transmission, and localization. Driven by the works mentioned above, this paper aims to analyze and integrate information related to wearable devices and provides a comprehensive overview of the different features of their use in maintaining and increasing work safety in potentially hazardous industries, as depicted in Figure 1.
For this work, we formulated the following research questions:
Sensors 21 03844 i001
To find the answers to our research questions, a widely-used methodology was adopted to carry out a systematic literature review based on the PRISMA [22]. To identify key publications on the analysis of wearable technology for work safety, we performed a literature search in scientific databases that cover leading computer science journals and conferences including IEEE Xplore, ACM Digital Library, ScienceDirect, SAGE Journals Online, and Springer Link. To find relevant articles and papers for our research, we applied the following search string: (Wearable OR “Body Area”) AND (Safety OR Industr* OR Injury) for the past five years and in the fields of Electrical Engineering, Applied Physics, Telecommunications, Biomedical Engineering, and Computer Information Systems. In total, we gathered a set of 1290 potentially relevant publications, excluding grey literature and pre-prints.
We then analyzed the titles, keywords, and abstracts of the publications to identify papers and articles that describe at least one modeling or simulation approach for distributed ledgers. While doing so, we selected a total of 75 publications. To further extend our literature sample, we analyzed the selected publications’ references for additional papers relevant to our research. Following this process, it resulted in a total of 68 publications. The literature list was further extended based on the additional references identified in the bodies of the selected ones or referencing those. Once the literature selection process was completed, we carefully read the selected publications to identify the described applications and challenges. The results of our analysis form the core of the topical literature review and are presented in the following sections.
The rest of this article is organized as follows. Section 2 discusses industrial wearables in more detail, considering main groups, functions, examples of applications, and benefits to the industry in general and from an occupational safety perspective in particular. Next, Section 3 highlights metrics, technologies, and approaches regarding the techniques of data collection, data transmission, and localization. Further, Section 4 provides the main challenges and future perspectives of this work. The last section concludes the paper.

2. Industrial Wearable Devices

The IIoT provides a wider view and a deeper understanding of the company’s processes by integrating different sensors, wearables, software, and data processing tools. The clearest advantage of wearables in IIoT is lucre, which is reached by increasing operational efficiency, reducing downtime, and optimizing business processes. Less frequently discussed in the literature, the benefit is related to how wearable technology can maintain workplace safety. It is necessary to identify the main sources of security threats and the causes of workplace accidents to answer the first research question. This paper, first of all, identifies the most dangerous industrial sectors in the world.
There are no general statistics on mortality from injuries by the industry sector. However, some countries keep such records providing statistics in ratios (commonly, the number of deaths per 100,000 workers) without mentioning the actual number of accidents. Hopefully, in the near future, the management of statistics in enterprises will be more widespread and, importantly, standardized so that data from different places can be easily compared, problems—identified, and experience in dealing with them—shared. Figure 2 outlines the results of investigations conducted in USA [23], Australia [24], Germany [25], Great Britain [26].
The most dangerous identified industry sectors are agriculture/forestry, construction, transportation, manufacturing, and trade. Due to differences in classification, most sectors such as mining, oil and gas extraction, and recycling fall under the “other” category. Notably, the four key causes in decreasing order of frequency are: fall from height, struck by moving/falling object, caught-in/between (when a worker is between the parts of machinery/object [27]), and hit by moving vehicle. Among the other reasons are also cuts, car crashes, reaction to improper motion, electrocutions, hazardous substances, chemicals [20,28]. According to [1], the main consequences that lead to death due to the last two reasons are chronic obstructive pulmonary disease and cancer (more often, lung cancer and mesothelioma). Nonetheless, constant stress should also be added to the list. Over time, employers have become more concerned with maintaining a favorable working atmosphere, but the impact of stress on human health is still underestimated in many organizations. In the short term, it may lead to various disorders, from chronic fatigue to depression. In the long-term, it may entail severe psychological problems and several problems such as the higher risk of myocardial ischemia, cardiac arrhythmia, anorexia, Alzheimer’s disease, insomnia, etc. [29,30].
Importantly, industrial wearables have increased requirements for reliability. Harsh industrial surroundings, characterized by extreme environmental values (extra-low/high temperatures, high radiation level, etc.), require the wearable device’s physical durability. Also, specific worksites impose the need to develop and improve the accuracy, range, response time, and robustness of traditional technologies. Wearables are one of the most promising solutions to eliminate or reduce the risk of both physical and mental accidents in workplaces. Currently, wearables are widely applied in enterprises and perform many tasks that improve the level of safety at work. Table 1 provides an answer to the first research question by identifying wearable features and functions that help maintain occupational safety.
All industrial wearables functions can be categorized into four groups: monitoring, supporting, training, and tracking. The informing function providing just-in-time information at the workplace and proposed in [18] is seldom represented as a standalone function nowadays and can be, thus, merged with the supporting function. Table 2 gives examples of wearable solutions currently applied in the most hazardous industry branches.
In summary, industries are replete with hazard sources resulting in a high work mortality rate. However, work safety levels can be increased by using wearable devices through the ten functions mentioned above.

3. State-of-the-Art Techniques in the Field of Industrial Wearables

The use of a wearable device in the functions discussed above involves other technical aspects, such as data collection, data transfer technologies, and localization methods. This section reviews the existing approaches, pointing out the most promising ones for industrial uses.

3.1. Data Collection and Wearable Metrics

The monitoring function is based on the collection of several metrics. In fact, no classification of metrics collected by wearable devices is currently available in research works. We, thus, divide these metrics into two groups depending on the data collected from wearables. The first group is related to the data “extracted” from the human body, and the second group deals with the environment’s information. Table 3 and Table 4 represent the most common wearable metrics and their classification.
In industrial scenarios and setups, the most important and frequent metrics related to the human body are temperature, heart rate, and location. Less commonly used metrics are motion and perspiration. However, the motion metric is essential for industries associated with lifting heavy loads (construction, logistics), and the perspiration can also be relevant for industries with a high probability of heat stress (e.g., mining) [44]. To the best of the authors’ knowledge, the rest of body-related metrics such as EEG, EMG, ECG, heart sounds, sleeping activity, etc. are not tracked in the industries yet, but they can help estimate both the worker’s physical and mental readiness for the industrial process. Developing a comprehensive, lightweight, wearable solution consisting of multiple sensors capable of measuring the human body’s vital parameters as possible will make a significant contribution to eliminating accidents due to human error in hazardous industries. Regarding the parameters related to the environment, it is hard to say what metrics are more frequently used. The industrial conditions define wearable devices’ choice and, consequently, the metrics that can be collected. In the reviewed literature, temperature, relative humidity, and air quality are often used as environment metrics.

3.2. Data Transmission

Historically, wearable solutions that appeared in the medical domain were based on a wired communication architecture, where wearable devices transmit their collected data to external processing units via wired links [44,118]. However, relying on wired connectivity restricts user mobility. This limitation was the main reason behind considering the wireless alternative for wearable communications. The migration from wired to wireless connectivity for data transmission is a trend in healthcare monitoring systems and industrial wearables in general. On top of the industrial wearable applications that are provided in Table 2, several examples were studied in the literature and utilized different wireless communication technologies [119,120,121]. These technologies can be classified based on various metrics, among which we choose the range. As a result, we provide in Table 5 a summary of the main short-range, mid-range, and long-range connectivity solutions currently employed in industrial wearable systems.
Due to the battery lifetime consideration, most market-available wearable devices generally rely on smartphone-aided operations using short-range and mid-range communication technologies. In this architecture, the smartphone pre-processes the data sent by the wearable device and acts as a gateway to transmit the pre-processed data to the cloud (if needed). The short-range and mid-range connectivity solutions in industrial wearable applications include Radio Frequency Identification (RFID), ZigBee, Bluetooth, Bluetooth Low Energy (BLE), and Wireless Fidelity (Wi-Fi) [122]. For instance, Reactec company has designed a wearable wristband that measures the amount of Hand-Arm Vibration (HAV) that provides real-time monitoring and automated reporting of HAV exposure [123]. This solution is called HAVWEAR and is utilized by several construction companies to prevent HAV-related diseases such as the white finger syndrome and, thus, to protect the workers’ health conditions. Each wristband contains an RFID card indicating the personalized exposure threshold that each operator should respect [123].
ZigBee and Bluetooth are among the Industrial Wireless Sensor Networks (IWSN) technologies based on the IEEE 802.15 standard and are characterized by the low energy consumption and the support of several topologies [124]. In [125], the authors proposed a wearable system that utilizes ZigBee technology and aims at improving the worker’s safety in the energy industry. As depicted in Table 5, examples of Wi-Fi medium-range standards include IEEE 802.11b, IEEE 802.11g, IEEE 802.11n, and IEEE 802.11ac.
Several life insurance companies offer Intel Basis Peak smartwatches to their customers to measure their heart rates, sleep patterns, and physical activities [123]. These smartwatches utilize Wi-Fi and Bluetooth standards for connectivity purposes. The data collected from the smartwatches are stored in the cloud, and real-time analytics can be performed to identify customers having healthy lifestyles, while various challenges related to data privacy arise since wearables are essentially processing person-identifiable biometric information [126]. In particular, the data processing should follow regional-specific regulations, e.g., General Data Protection Regulation (GDPR) in EU [127].
Furthermore, wearable devices can be equipped with both short-range and long-range connectivity chipsets. It can be justified by the device manufacturers’ aim to enable standalone and hands-free operations for wearable devices and end-users, respectively [128]. The main long-range connectivity solutions considered for industrial wearable applications are based on low-power wide-area (LPWA) standards. As their name suggests, LPWA technologies are optimized for low power operation, thus, the long battery life in low-end wearable applications. In [120], the authors demonstrated a smart shoe that harvests mechanical and solar energy to provide it to the LoRa radio component. These smart shoes can be utilized in tracking and physical activity monitoring applications. Similar to LoRa technology, Sigfox is also among the LPWA solutions that are being used in wearable tracking systems [129].
Tracking applications are not the only services that can be provided by wearable solutions using long-range communication technologies. For instance, the AlertGPS wearable devices offer a multitude of functionalities for worker safety, including mass notifications in cases of fire, bad weather, or other emergency situations [123]. They also offer the feature of emergency calls where the worker can initiate a call with a safety agent using conventional Long-Term Evolution (LTE) cellular technology [130]. Although the adoption of licensed cellular technologies in wearable solutions has not received enough attention in the literature, the cellular IoT standards that were ratified by the 3rd generation partnership project (3GPP) to support the LPWA operations can enable wearable applications with better coverage, scalability, interoperability, quality of service (QoS), and security [19]. These cellular IoT standards include narrowband IoT (NB-IoT) and LTE-machine type communications (LTE-M). Despite being introduced in 3GPP Release 13 as part of LTE standards, NB-IoT and LTE-M fulfill the international mobile telecommunications-2020 (IMT-2020) requirements for massive machine-type communications (mMTC) and can be, as confirmed in the 3GPP study on self-evaluation towards IMT-2020 submission, certified as 5G technologies [131].
Table 5. Communication technologies utilized in industrial wearable applications.
Table 5. Communication technologies utilized in industrial wearable applications.
CategoryTechnologyFrequencyMax. Data RateRefs.
Short-range
(<100 m)
RFID0.86 GHz40 kbps [132]
Zigbee868 MHz, 915 MHz, 2.4 GHz20 kbps, 40 kbps, 250 kbps [125]
Bluetooth2.4 GHz1–3 Mbps [123,133]
BLE2.4 GHz125 kbps–2 Mbps [123,133]
Mid-range
(100 m–5 km)
IEEE 802.11b2.4 GHz1–11 Mbps [123,134]
IEEE 802.11g2.4 GHz6–54 Mbps [123,135]
IEEE 802.11n2.4/5 GHzUp to 600 Mbps [123,135]
IEEE 802.11ac5 GHzUp to 1 Gbps [123,135]
Long-range
(>5 km)
LoRa915–928/863–870/433 MHz50 kpbs [136,137]
Sigfox868/902 MHz100 bps [129]
LTE3GPP frequency bands100 Mbps [130]
LTE-M3GPP frequency bands1 Mbps [138]
NB-IoT3GPP frequency bands250 kbps [139,140]
On top of the currently utilized short-range, mid-range, and long-range technologies provided in Table 5 and with the increasing attention addressed to industrial wearables, other candidate communication technologies are lately being taken into account and studied to support the novel requirements. Among these, the IEEE 802.11ah standard, also known as Wi-Fi HaLow, is considered to be an enabler of the low-power connectivity required in wearable applications [141]. Its extended range can provide wearable devices with seamless connections in challenging environments like industrial setups and, being backward compatible, is expected to allow seamless integration with higher energy efficiency [142]. Further, and on top of the cellular IoT standards for wearable mMTC, certain industrial wearable applications can have requirements [143] that are similar to the other two 5G service classes, namely enhanced mobile broadband (eMBB) and ultra-reliable and low latency communications (URLLC) [144]. For instance, AR and VR-based applications require high data rates, high reliability, and low latency and can utilize the millimeter wave (mmWave) 5G technology [145]. Other potential mmWave and terahertz technologies for industrial high-end wearable applications include IEEE 802.11ad (also called WiGig) and Visible Light Communications (VLC), respectively.

3.3. Localization Techniques

As mentioned, identifying the exact location of the objects is one of the most important functions performed by wearable devices. There are two types of objects in industries: machinery/equipment and personnel. Accurate positioning is key to preventing worker collision with moving machinery, exclusion of an opportunity of unauthorized access to hazardous work areas and equipment, successful evacuation, and efficient distribution of labor. However, positioning continues to be one of the most challenging problems for industrial wearable devices due to the nature of the workplace (e.g., underground, underwater) and, at the same time, high accuracy requirements. Moreover, employee location tracking also raises data ownership, security, and privacy questions, which will be explored in more detail in the next section.
All location tracking techniques could be divided into two groups: methods depending on range and range-free techniques [146]. The first group considers the conversion of various parameters to the range. It comprises time-based measurements (Time of Arrival (ToA), Time Difference of Arrival (TDoA)), angle-based measurements (Angle of Arrival (AoA), Angle of Departure (AoD), power-based measurements (Received Signal Strength Indicator (RSSI), in connection with which path loss models are used).
In the second group’s schemes, for example, in the Distance Vector-Hop algorithm (DV-HOP), anchors broadcasting their location to the whole network, and unknown nodes estimate their location based on the proximity to these known anchors (hop size and hope count). Such algorithms can be used without any additional equipment [146]. The choice between these two groups is based on the trade-off between price and accuracy: range-based techniques provide high precision, but their application is quite expensive. Range-free techniques are usually considered a cheaper and less precise alternative to the first group.
To choose the localization solution for a particular case, one should review such parameters as the environment (outdoor/indoor), coverage, power consumption, scalability, price, and accuracy.
The first question is what environment is more typical for industrial cases: outdoor or indoor. This question is essential since the different conditions dictate different approaches for these two cases [146]. While indoors is the scatter-rich environment where the path loss model’s prediction is a big challenge, outdoors usually have Line-of-Sight. For the same reason, achieving high accuracy in the first case is much more complicated than in the second. However, it is more desirable, especially during evacuations from the rubble or other emergency cases. In outdoor cases, random existing static anchor stations are usually used to determine the location, whereas in indoor cases, anchors’ deployment could require complex preliminary calculations. We further consider the techniques from both indoor and outdoor cases, see Table 6.
Usually, we want to identify the worker’s position in a relatively limited area, referring mainly to indoor localization. It is worth noticing that in such manufactures as construction or logistics, for example, just indoor localization is not sufficient. Thus, the perfect variant for some industries would require seamless connectivity, which continuously monitors the location of people/equipment/assets. However, seamless localization is still a problem: there is no localization solution for both outdoors and indoor cases and cellular-based solutions have lousy accuracy. This situation is expected to be changed with the coming 5G that, as was announced, will ensure sub-meter accuracy. However, the question is still open.
As mentioned before, localization accuracy is still a big issue, especially in the indoor environment. To improve it, engineers explore and apply different combinations of technologies as it was done in QUUPPA Intelligent Locating System where RSSI was combined with AoA Direction Finding signal processing methodology [164]. However, the declared high accuracy of less than 10 cm is offset by high cost, small coverage, and relative deployment complexity [165].
Another big issue in this area is providing an accurate localization in underground work sites. For these purposes, ground-based pseudolites (pseudo-satellite transmitters) can provide localization in industrial environments where the GPS has poor or no coverage, such as deep, open-pit mining, high water dams; urban canyons; large indoor industrial halls. Two well-known positioning solutions are LocataNet, developed by Locata Corporation/Leica, and Terralite XPS, developed by Trimble. Both use a network consisting of fixed pseudolites installed on the ground, around the perimeter of the objective; mobile receivers installed on moving equipment such as heavy engineering vehicles and aircraft [166,167,168]. These pseduolite systems operate in industrial environments such as Boddington Gold Mine (Australia), Morenci Copper Mine (Arizona, USA), White Sands Missile Range (New Mexico, USA). The main advantages are centimeter-level accuracy, coverage radius of several tens of km, obtained with just 10 pseudolites [168]. These systems require an initial complex ground deployment and set-up by the manufacturer on-site. The puseudolites need access to a power source and a clear line of sight for best precision. This solution was still not applied in the IIoT area to the best of the authors’ knowledge but should be considered a promising one. Other positioning methods proposed for underground workspaces are: ZigBee, Visible Light Communication [169], WiFi, BLE, Inertial Measurement Units [170], image-assisted person localization [171]. Most of them require a large density of beacons and stations, offering meter accuracy. For example, in the USA, since 2006, all mine operators must adopt electronic tracking systems, RFID being the most popular solution [172].
To conclude, choosing the appropriate localization techniques in each case compromises accuracy, coverage, power consumption, scalability, and price. When discussing localization techniques for industrial wearables, we need to consider that we usually deal with low throughput, low power, small size, and specific locations (underground, underwater). The position is an essential parameter for work safety providing and remains one of the main accuracy-related issues (especially in indoor and underground conditions) and smoothness of tracking.

4. Challenges and Future Perspective

Nowadays, the innovations’ speed has significantly increased compared with the last decades: the new technologies boost the development of another technology, facilitate our lives, and create solutions in different areas, including the enterprises’ sector. Along with the challenge of improving work efficiency, IIoT, and wearable devices, as part of it, help the industry cope with the challenge of ensuring a high safety level at work. However, the new technologies open new opportunities and bring new questions and the old challenges for which no reliable solution has been found. In this section, we summarized the most significant ones in Table 7.
In [18], the authors highlight the main challenge groups compliant with the adoption of wearable devices: technological, social, economic, data-related, and standards-related. Using the same terms, let us highlight the main challenges and areas for further investigation in industrial devices, directly or indirectly contributing to preserving human health and life.
In the framework of technological issues, several previous works pointed out the problems of finding the trade-off between functionality, battery life of a wearable device, its size and convenience for the user, adjusting one device to several users in big industries, management, and processing of the considerable amount of data produced by the heterogeneous devices [18,92]. In addition to it, it is also worth noting the problem of ensuring high accuracy of positioning, especially in indoor scatter-rich environments. Currently, one of the most spread solutions is Wi-Fi fingerprinting. However, it is quite power-consuming for industrial wearable devices. While the indoor environment is more typical for industrial scenarios, the outdoor environment is also not rare: such sectors as agriculture, logistics, forestry, etc., involve large work sites.
Moreover, some industries, e.g., construction, include both types of environment. It raises the question of the possibility of ensuring seamless localization since it is more convenient for an enterprise to use one technology in terms of price and compatibility. However, nowadays, we still do not have a reliable solution for this purpose, and cellular technology does not meet high precision requirements. Currently, active attempts are being made to close this research gap, and the 5th generation of mobile communications promises to improve the situation on this issue significantly.
Another sharp technological problem is the development of connectivity solutions and propagation models in underground work sites, especially in the sector of coal mining, which is considered as one of the riskiest places of work due to the high probability of roof-falling, the concentration of toxic gases, explosions and so on. In this case, technology should cope with low-power signals, electrical interference, multiple reflections across the corners, and at greater depth [177]. The problem of the existing solutions like Wi-Fi, Zigbee, Bluetooth, cellular technologies lies in short communication distance and high delay [178]. Simultaneously, the need to develop a reliable technology for this field is undeniable and creates a direction for further research.
Talking about large worksites and the deployment of wearable sensor networks supporting many environmental and wearable devices, we will still meet the issues of power consumption and supply due to the necessity to track and sustain a charge of a large number of devices. Substantial efforts over the past decades resulted in the development of long-lived batteries, which partially resolved the challenge. However, in some industries, the power consumption level is still very high compared to energy provision. One of the promising directions in this field is the energy harvesting approaches of light, rainwater, motion, and temperature gradients. In work [136], the authors designed a micro-power manager that can obtain energy both indoors and outdoors due to solar panels embedded in the construction of the device and thus constantly support sensor node feeding. Similarly, nowadays market offers wearable devices that can extract energy from the sun, for example, T-shirts [194] or smartwatches [195], however, for example, for the mining industry, it is not an option.
The next problem is related to privacy and security. It covers three groups simultaneously: technological, data-related, and social. Confidentiality of the data is a big question in this area: wearable devices become subject to a wide range of external attacks due to communication with another device, limited bandwidth, and processing power [180,182]. Various approaches are applied to improve the technological part of security and privacy challenges, and one of the most actively studied is ECC, the main advantage of which from the point of view of wearable devices is light weight [180,181]. However, the current world situation shows that existing solutions are not sufficient to ensure security in industries. For example, mining companies are of great interest for espionage, as they contain data on the location of valuable minerals. According to [196], 54 percent of companies in the mining/metal industry were attacked in 2019, and these numbers tend to grow. This state of affairs sets another relevant direction of development in the field of industrial wearable devices.
The question of location data privacy, namely, finding the trade-off between the accuracy of positioning of the worker and confidentiality, can be singled out separately. The exact location is essential in industries, especially during evacuation sessions. However, as was mentioned before, workers feel nervous being tracked all the time, consequently, the likelihood of error increases. Significantly, the localization could be executed either on the device itself or in the centralized processing point [185]. The second option requires additional obfuscation to provide the desired level of privacy for the user. The authors of [183] discuss the various obfuscation techniques to overcome this issue.
Data-related and social groups consider security and privacy issues from the side of data ownership questions [18,197]: how the data is distributed, who has access to it, and how it could be used. Lack of information about the flows of data collected in the workplace builds mistrust of the technology. M. Kritzler et al. in [190] state that this problem could be eliminated by a clear explanation of the purposes of the implementation of wearable technology in the enterprise. Since most employees do not share their personal information with the employer, this method is not effective, and this problem also remains on the list of research agendas for next years.
The last main challenge in industrial wearables that we would like to address here is social resistance to adopting technology. For any innovation in modern society, the level of acceptability is even more important than the corresponding benefits and usefulness [198]. Workers feel constant pressure being monitored all the time, which increases their stress level and, consequently, the probability of injury. Also, they afraid that the collected by wearables raw information, which they cannot control, improve or modify, may become a reason for dismissal or fines. Some workers cannot quickly learn how to use the wearable device and do not want to spend additional time on it, considering the traditional way of the work process as the most convenient and the only possible. The literature and practice offer several options to improve the situation, such as more friendly interfaces, video guidance, constant support. V. Jacobs et al. in [189] distinguish the row of factors that predicts the level of acceptance of industrial wearables and suggests a list of actions that should accelerate the process.
In summary, the above discussion identifies some research directions that should be explored during the next decades to accelerate the adoption of wearable technology in industries and, thus, increase work safety. Table 7 gathers the key challenges in the field of industrial wearables and general issues which are specific to the area of wearable technology.

5. Conclusions

Modern wearable devices already offer several opportunities to maintain occupational safety in the work environment rife with various hazard sources. This work identifies four key functions (monitoring, supporting, training, and tracking) and ten sub-functions, showing which wearables can directly or indirectly contribute to preserving workplace safety to assess wearables’ use cases and benefits for industrial work safety. Additionally, this article summarizes and classifies metrics collected by wearable devices (12 metrics related to the body and 8 metrics related to the environment), thereby showing how enterprises can control workplace safety from both personnel and environment perspectives.
It is essential to highlight that discussed modern techniques for communication, localization, and privacy protection in wearable technology still cannot fully cover all industries’ needs. The level of social resistance is still considered very high, slowing down the widespread adoption of wearable devices in enterprises. The present article summarizes the key open challenges (technological, data-related, standard-related, economic, and social) and suggests possible solutions, pointing to a wide field for future research on industrial wearable solutions for occupational safety.

Author Contributions

Conceptualization, E.S.; investigation, E.S., and S.S.; writing—original draft preparation, E.S.; writing—review and editing, S.S., A.R.-C., R.B., I.M., J.H., A.O.; supervision, A.R.-C., R.B., I.M., J.H., A.O. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by European Union’s Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No. 813278 (A-WEAR).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviations

The following abbreviations are used in this manuscript:
AoAAngle of Arrival
AoDAngle of Departure
AQIAir Quality Index
BLEBluetooth Low Energy
DV-HOPDistance Vector-Hop
ECGElectrocardiogram
EEGElectroencephalogram
eMBBEnhanced Mobile Broadband
EMGElectromyography
GNSSGlobal Navigation Satellite System
GPSGlobal Positioning System
HAVHand-arm Vibration
IEEEInstitute of Electrical and Electronics Engineers
IIoTIndustrial Internet of Things
ILOInternational Labor Organization
IoTInternet of Things
IWSNIndustrial Wireless Sensor Networks
LoRaWANLong-Range Wide-area Network
LPWANLow-power Wide-area Network
MDPIMultidisciplinary Digital Publishing Institute
mMTCMassive Machine-type Communications
NB-IoTNarrowband IoT
RFIDRadio Frequency Identification
RSSIReceived Signal Strength Indicator
TDoATime Difference of Arrival
ToATime of Arrival
UEUser Equipment
URLLCUltra-Reliable and Low Latency Communications
UVIUltraviolet Index
VLCVisible Light Communications
WHOWorld Health Organization

References

  1. World Health Organisation. Number of Deaths Due to Work-Related Accidents. Available online: https://gateway.euro.who.int/en/indicators/hfa_457-4071-number-of-deaths-due-to-work-related-accidents/visualizations/#id=19493&tab=graph (accessed on 27 May 2021).
  2. Wu, F.; Wu, T.; Yuce, M.R. Design and Implementation of a Wearable Sensor Network System for IoT-connected Safety and Health Applications. In Proceedings of the 5th World Forum on Internet of Things (WF-IoT)., Limerick, Ireland, 15–18 April 2019; IEEE: Piscatvey, NJ, USA, 2019; pp. 87–90. [Google Scholar]
  3. International Labor Organization. World Statistics. Available online: https://www.ilo.org/moscow/areas-of-work/occupational-safety-and-health/WCMS_249278/lang–en/index.htm (accessed on 27 May 2021).
  4. Worldometer. Countries in the World by Population (2021). Available online: https://www.worldometers.info/world-population/population-by-country/ (accessed on 27 May 2021).
  5. Masek, P.; Hudec, D.; Krejci, J.; Ometov, A.; Hosek, J.; Andreev, S.; Kroepfl, F.; Koucheryavy, Y. Advanced Wireless m-Bus Platform for Intensive Field Testing in Industry 4.0-Based Systems. In Proceedings of the 4th European Wireless Conference, Catania, Italy, 2–4 May 2018; VDE: Berlin, Germany, 2018; pp. 1–6. [Google Scholar]
  6. Qaim, W.B.; Ometov, A.; Molinaro, A.; Lener, I.; Campolo, C.; Lohan, E.S.; Nurmi, J. Towards Energy Efficiency in the Internet of Wearable Things: A Systematic Review. IEEE Access 2020, 8, 175412–175435. [Google Scholar] [CrossRef]
  7. Meticulous Research. Industrial IoT (IIoT) Market Worth 263.4 Billion Dollars by 2027- Exclusive Report Covering Pre and Post COVID-19 Market Analysis and Forecasts by Meticulous Research. Available online: https://www.globenewswire.com/news-release/2020/06/19/2050758/0/en/Industrial-IoT-IIoT-Market-Worth-263-4-billion-by-2027-Exclusive-Report-Covering-Pre-and-Post-COVID-19-Market-Analysis-and-Forecasts-by-Meticulous-Research.html (accessed on 27 May 2021).
  8. Hosek, J.; Masek, P.; Andreev, S.; Galinina, O.; Ometov, A.; Kropfl, F.; Wiedermann, W.; Koucheryavy, Y. A SyMPHOnY of Integrated IoT Businesses: Closing the Gap between Availability and Adoption. IEEE Commun. Mag. 2017, 55, 156–164. [Google Scholar] [CrossRef]
  9. Gilchrist, A. The Industrial Internet of Things—Industry 4.0. Available online: https://www.academia.edu/38736167/The_Industrial_Internet_of_Things_Industry_4_0 (accessed on 27 May 2021).
  10. BBC. Unemployment Rate: How Many People Are Out of Work? Available online: https://www.bbc.com/news/business-52660591 (accessed on 27 May 2021).
  11. The Influence of the COVID-19 Pandemic on the Internet of Things (IoT) Market. Available online: https://projects.tuni.fi/a-wear/news/the-influence-of-the-covid-19-pandemic-on-the-internet-of-things-iot-market/ (accessed on 27 May 2021).
  12. Estimote. Workplace Safety with Wearables. Available online: https://estimote.com/wearable/ (accessed on 27 May 2021).
  13. Allied Market Research. Wearable Technology Market Overview. Available online: https://www.alliedmarketresearch.com/wearable-technology-market (accessed on 27 May 2021).
  14. Industry ARC. Wearable Technology Market—Industry Analysis, Market Size, Share, Trends, Application Analysis, Growth And Forecast 2020–2025. Available online: https://www.industryarc.com/Research/Wearable-Technology-Market-Research-504119 (accessed on 27 May 2021).
  15. Grand View Research. Wearable Technology Market Size, Share; Trends Analysis Report by Product (Wrist-Wear, Eye-Wear, Head-Wear, Foot-Wear, Neck-Wear, Body-Wear), by Application, by Region, and Segment Forecasts, 2020–2027. Available online: https://www.grandviewresearch.com/industry-analysis/wearable-technology-market (accessed on 27 May 2021).
  16. Statista. Market Share of Wearables Unit Shipments Worldwide by Vendor from 1Q’14 to 1Q’20. Available online: https://www.statista.com/statistics/435944/quarterly-wearables-shipments-worldwide-market-share-by-vendor/ (accessed on 27 May 2021).
  17. Ometov, A.; Shubina, V.; Klus, L.; Skibińska, J.; Saafi, S.; Pascacio, P.; Flueratoru, L.; Gaibor, D.Q.; Chukhno, N.; Chukhno, O.; et al. A Survey on Wearable Technology: History, State-of-the-Art and Current Challenges. Comput. Netw. 2021, 193, 108074. [Google Scholar] [CrossRef]
  18. Khakurel, J.; Melkas, H.; Porras, J. Tapping into the Wearable Device Revolution in the Work Environment: A Systematic Review. Inf. Technol. People 2018, 31, 791–818. [Google Scholar] [CrossRef] [Green Version]
  19. Dian, F.J.; Vahidnia, R.; Rahmati, A. Wearables and the Internet of Things (IoT), Applications, Opportunities, and Challenges: A Survey. IEEE Access 2020, 8, 69200–69211. [Google Scholar] [CrossRef]
  20. Mardonova, M.; Choi, Y. Review of Wearable Device Technology and Its Applications to the Mining Industry. Energies 2018, 11, 547. [Google Scholar] [CrossRef] [Green Version]
  21. Barata, J.; da Cunha, P.R. Safety is the New Black: The Increasing Role of Wearables in Occupational Health and Safety in Construction. In Proceedings of the International Conference on Business Information Systems, Seville, Spain, 26–28 June 2019; Springer: Berlin/Heidelberg, Germany, 2019; pp. 526–537. [Google Scholar]
  22. Liberati, A.; Altman, D.G.; Tetzlaff, J.; Mulrow, C.; Gøtzsche, P.C.; Ioannidis, J.P.; Clarke, M.; Devereaux, P.J.; Kleijnen, J.; Moher, D. The PRISMA Statement for Reporting Systematic Reviews and Meta-Analyses of Studies that Evaluate Health Care Interventions: Explanation and Elaboration. J. Clin. Epidemiol. 2009, 62, e1–e34. [Google Scholar] [CrossRef] [Green Version]
  23. Statista. Occupational Injury Death Rate in 2018, by Private Industry Sector. Available online: https://www.statista.com/statistics/284861/occupational-injury-death-rate-in-2012-by-private-industry-sector/ (accessed on 27 May 2021).
  24. Safe work Australia. Fatality Statistics by Industry. Available online: https://www.safeworkaustralia.gov.au/statistics-and-research/statistics/fatalities/fatality-statistics-industry (accessed on 27 May 2021).
  25. Quentic. The Top 3 Most Dangerous Industry Sectors to Work at in Germany. Available online: https://www.quentic.com/blog/dv/2281-the-top-3-most-dangerous-industry-sectors-to-work-at-in-germany/ (accessed on 27 May 2021).
  26. HSE. Workplace Fatal Injuries in Great Britain. 2019. Available online: https://www.hse.gov.uk/statistics/pdf/fatalinjuries.pdf (accessed on 27 May 2021).
  27. Constructconnect. Avoiding OSHA’s Fatal Four—Caught-In/Between Hazards. Available online: https://www.aftermath.com/content/workplace-accident-statistics/ (accessed on 27 May 2021).
  28. Awolusi, I.; Marks, E.; Hallowell, M. Wearable Technology for Personalized Construction Safety Monitoring and Trending: Review of Applicable Devices. Autom. Constr. 2018, 85, 96–106. [Google Scholar] [CrossRef]
  29. O Donovan, R.; Doody, O.; Lyons, R. The Effect of Stress on Health and Its Implications for Nursing. Br. J. Nurs. 2013, 22, 969–973. [Google Scholar] [CrossRef] [Green Version]
  30. Yaribeygi, H.; Panahi, Y.; Sahraei, H.; Johnston, T.P.; Sahebkar, A. The impact of stress on body function: A review. Excli J. 2017, 16, 1057. [Google Scholar] [PubMed]
  31. Optalert. Eagle Industrial. Available online: https://www.optalert.com/explore-products/eagle-industrial/ (accessed on 27 May 2021).
  32. Qoowear. Boosting The Safety Of Workers in Sub-Zero Environments. Available online: http://qoowear.com/ (accessed on 27 May 2021).
  33. Eleksen. Smart Workforce Safety. Available online: https://eleksen.com/ (accessed on 27 May 2021).
  34. MyExposome. Lightweight Simple Wristbands. Available online: http://www.myexposome.com/approach (accessed on 27 May 2021).
  35. Laevo Exoskeletons. Our Wearable Chest and Back Support. Available online: https://www.laevo-exoskeletons.com/en/laevo-v2 (accessed on 27 May 2021).
  36. DIGI. Kinetic Creates An Innovative Wearable That Reduces Workplace Injuries And Increases Safety Using Digi IoT Solutions. Available online: https://www.digi.com/customer-stories/kinetic-wearable-reduces-workplace-injuries (accessed on 27 May 2021).
  37. Masood, J.; Dacal-Nieto, A.; Alonso-Ramos, V.; Fontano, M.I.; Voilqué, A.; Bou, J. Industrial Wearable Exoskeletons and Exosuits Assessment Process. In Proceedings of the International Symposium on Wearable Robotics, Pisa, Italy, 16–20 October 2018; Springer: Berlin/Heidelberg, Germany, 2018; pp. 234–238. [Google Scholar]
  38. Codered. Signal 21 Speaker Microphone. Available online: https://www.coderedheadsets.com/Signal-21-Speaker-Microphone-p/signal21.htm (accessed on 27 May 2021).
  39. Realwear. RealWear—Digital Workflow with Industrial Wearable. Available online: https://www.gitex.com/video-gallery/realwear-digital-workflow-with-industrial-wearable (accessed on 27 May 2021).
  40. Capgemini. Augmented and Virtual Reality. Available online: https://www.capgemini.com/wp-content/uploads/2018/09/AR-VR-in-Operations1.pdf (accessed on 27 May 2021).
  41. Solepower. Powering the Future One Step at a Time. Available online: http://www.solepowertech.com/#solepower (accessed on 27 May 2021).
  42. Guardhat. Human Centric Solutions Built for the Real World. Available online: https://www.guardhat.com/ (accessed on 27 May 2021).
  43. OilPrice. Augmented Reality Is A Game Changer for Oil & Gas. Available online: https://oilprice.com/Energy/Energy-General/Augmented-Reality-Is-A-Game-Changer-For-Oil-Gas.html (accessed on 27 May 2021).
  44. Mine Safety and Health Administration (MSHA). Heat Stress in Mining. Available online: https://www.msha.gov/sites/default/files/AlertsandHazards/HeatStress.pdf (accessed on 27 May 2021).
  45. WebMDe. Diastole vs. Systole: Know Your Blood Pressure Numbers. Available online: https://www.webmd.com/hypertension-high-blood-pressure/guide/diastolic-and-systolic-blood-pressure-know-your-numbers#1 (accessed on 27 May 2021).
  46. Fourier. Blood Pressure Sensor DT098. Available online: https://fourieredu.com/fwp/store/products/blood-pressure-sensor (accessed on 27 May 2021).
  47. Vernier. Blood Pressure Sensor. Available online: https://www.vernier.com/product/blood-pressure-sensor/ (accessed on 27 May 2021).
  48. Stergiou, G.S.; Alpert, B.; Mieke, S.; Asmar, R.; Atkins, N.; Eckert, S.; Frick, G.; Friedman, B.; Graßl, T.; Ichikawa, T.; et al. A Universal Standard for the Validation of Blood Pressure Measuring Devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration Statement. Hypertension 2018, 71, 368–374. [Google Scholar] [CrossRef]
  49. Pantelopoulos, A.; Bourbakis, N.G. A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis. IEEE Trans. Syst. Man Cybern. Part Appl. Rev. 2009, 40, 1–12. [Google Scholar] [CrossRef] [Green Version]
  50. Bard, D.M.; Joseph, J.I.; van Helmond, N. Cuff-less Methods for Blood Pressure Telemonitoring. Front. Cardiovasc. Med. 2019, 6, 40. [Google Scholar] [CrossRef]
  51. Fotouhi-Ghazvini, F.; Abbaspour, S. Wearable Sireless Sensors for Measuring Calorie Consumption. J. Med Signals Sensors 2020, 10, 19. [Google Scholar] [CrossRef] [PubMed]
  52. Lester, J.; Hartung, C.; Pina, L.; Libby, R.; Borriello, G.; Duncan, G. Validated Caloric Expenditure Estimation Using a Single Body-worn Sensor. In Proceedings of the 11th International Conference on Ubiquitous Computing, Orlando, FL, USA, 30 September–3 October 2009; pp. 225–234. [Google Scholar]
  53. Jain, S.K.; Bhaumik, B. An Energy Efficient ECG Signal Processor Detecting Cardiovascular Diseases on Smartphone. IEEE Trans. Biomed. Circuits Syst. 2016, 11, 314–323. [Google Scholar] [CrossRef] [PubMed]
  54. Azariadi, D.; Tsoutsouras, V.; Xydis, S.; Soudris, D. ECG Signal Analysis and Arrhythmia Detection on IoT Wearable Medical Devices. In Proceedings of the 5th International Conference on Modern Circuits and Systems Technologies (MOCAST), Thessaloniki, Greece, 12–14 May 2016; IEEE: Piscatvey, NJ, USA, 2016; pp. 1–4. [Google Scholar]
  55. Li, M.; Xiong, W.; Li, Y. Wearable Measurement of ECG Signals Based on Smart Clothing. Int. J. Telemed. Appl. 2020, 2020, 6329360. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  56. QARDIO. QARDIOCORE. Available online: https://www.getqardio.com/qardiocore-wearable-ecg-ekg-monitor-iphone/ (accessed on 27 May 2021).
  57. Athavale, Y.; Krishnan, S. Biosignal Monitoring Using Wearables: Observations and Opportunities. Biomed. Signal Process. Control. 2017, 38, 22–33. [Google Scholar] [CrossRef]
  58. Subha, D.P.; Joseph, P.K.; Acharya, R.; Lim, C.M. EEG Signal Analysis: A Survey. J. Med Syst. 2010, 34, 195–212. [Google Scholar] [CrossRef] [PubMed]
  59. Wei, Y.; Wu, Y.; Tudor, J. A Real-time Wearable Emotion Detection Headband based on EEG Measurement. Sens. Actuators Phys. 2017, 263, 614–621. [Google Scholar] [CrossRef] [Green Version]
  60. Ahn, J.W.; Ku, Y.; Kim, H.C. A Novel Wearable EEG and ECG Recording System for Stress Assessment. Sensors 2019, 19, 1991. [Google Scholar] [CrossRef] [Green Version]
  61. Emotiv. Brain Controlled Technology. Available online: https://www.emotiv.com/brain-controlled-technology/ (accessed on 27 May 2021).
  62. Hettiarachchi, C.; Kodithuwakku, J.; Manamperi, B.; Ifham, A.; Silva, P. A Wearable System to Analyze the Human Arm for Predicting Injuries due to Throwing. In Proceedings of the 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany, 23–27 July 2019; IEEE: Piscatvey, NJ, USA, 2019; pp. 3297–3301. [Google Scholar]
  63. Milosevic, B.; Benatti, S.; Farella, E. Design challenges for wearable EMG applications. In Proceedings of the Design, Automation & Test in Europe Conference & Exhibition (DATE), Lausanne, Switzerland, 27–31 March 2017; IEEE: Piscatvey, NJ, USA, 2017; pp. 1432–1437. [Google Scholar]
  64. Shimmer. Shimmer3 EMG Unit. Available online: https://www.emotiv.com/brain-controlled-technology/ (accessed on 27 May 2021).
  65. Myonetic. Sports. Available online: https://www.myontec.com/sports (accessed on 27 May 2021).
  66. MedlinePlus. Diabetes. Available online: https://medlineplus.gov/ency/article/001214.htm (accessed on 27 May 2021).
  67. Ciechanowski, P.S.; Katon, W.J.; Russo, J.E.; Hirsch, I.B. The Relationship of Depressive Symptoms to Symptom Reporting, Self-Care and Glucose Control in Diabetes. Gen. Hosp. Psychiatry 2003, 25, 246–252. [Google Scholar] [CrossRef]
  68. Rodin, D.; Kirby, M.; Sedogin, N.; Shapiro, Y.; Pinhasov, A.; Kreinin, A. Comparative Accuracy of Optical Sensor-based Wearable System for Non-invasive Measurement of Blood Glucose Concentration. Clin. Biochem. 2019, 65, 15–20. [Google Scholar] [CrossRef] [PubMed]
  69. WHOOP. Overview of the Whoop Strap 3.0. Available online: https://www.whoop.com/thelocker/whoop-strap-3-0-overview/ (accessed on 27 May 2021).
  70. Bobrowski, T.; Schuhmann, W. Long-Term Implantable Glucose Biosensors. Curr. Opin. Electrochem. 2018, 10, 112–119. [Google Scholar] [CrossRef]
  71. Meetoo, D.; Wong, L.; Ochieng, B. Smart Tattoo: Technology for Monitoring Blood Glucose in the Future. Br. J. Nurs. 2019, 28, 110–115. [Google Scholar] [CrossRef] [PubMed]
  72. Bellmann, B.; Gemein, C.; Schauerte, P. Regular Pulse Rate but Irregular Heart Rate? Neth. Heart J. 2016, 24, 435–437. [Google Scholar] [CrossRef] [Green Version]
  73. Ge, Z.; Prasad, P.; Costadopoulos, N.; Alsadoon, A.; Singh, A.; Elchouemi, A. Evaluating the Accuracy of Wearable Heart Rate Monitors. In Proceedings of the 2nd International Conference on Advances in Computing, Communication, & Automation (ICACCA)(Fall), Bareilly, India, 30 September–1 October 2016; IEEE: Piscatvey, NJ, USA, 2016; pp. 1–6. [Google Scholar]
  74. Hanning, C.; Alexander-Williams, J. Fortnightly Review: Pulse Oximetry: A Practical Review. BMJ 1995, 311, 367–370. [Google Scholar] [CrossRef]
  75. Myzone. MZ-3. Available online: https://www.myzone.org/mz-3 (accessed on 27 May 2021).
  76. Vermarien, H. Phonocardiography. In Encyclopedia of Medical Devices and Instrumentation; John Wiley & Sons Inc.: Hoboken, NJ, USA, 2006. [Google Scholar] [CrossRef]
  77. Dwivedi, A.K.; Imtiaz, S.A.; Rodriguez-Villegas, E. Algorithms for Automatic Analysis and Classification of Heart Sounds–A Systematic Review. IEEE Access 2018, 7, 8316–8345. [Google Scholar] [CrossRef]
  78. Wong, C.; Zhang, Z.Q.; Lo, B.; Yang, G.Z. Wearable Sensing for Solid Biomechanics: A Review. IEEE Sens J. 2015, 15, 2747–2760. [Google Scholar]
  79. Ometov, A.; Solomitckii, D.; Olsson, T.; Bezzateev, S.; Shchesniak, A.; Andreev, S.; Harju, J.; Koucheryavy, Y. Secure and Connected Wearable Intelligence for Content Delivery at a Mass Event: A Case Study. J. Sens. Actuator Netw. 2017, 6, 5. [Google Scholar] [CrossRef] [Green Version]
  80. Norris, M.; Anderson, R.; Kenny, I.C. Method Analysis of Accelerometers and Gyroscopes in Running Gait: A Systematic Review. Proc. Inst. Mech. Eng. Part J. Sport. Eng. Technol. 2014, 228, 3–15. [Google Scholar] [CrossRef] [Green Version]
  81. Webster, M. Sweat. Available online: https://www.merriam-webster.com/dictionary/sweat (accessed on 27 May 2021).
  82. Legner, C.; Kalwa, U.; Patel, V.; Chesmore, A.; Pandey, S. Sweat Sensing in the Smart Wearables Ara: Towards Integrative, Multifunctional and Body-Compliant Perspiration Analysis. Sens. Actuators Phys. 2019, 296, 200–221. [Google Scholar] [CrossRef]
  83. Parrilla, M.; Guinovart, T.; Ferré, J.; Blondeau, P.; Andrade, F.J. A Wearable Paper-based Sweat Sensor for Human Perspiration Monitoring. Adv. Healthc. Mater. 2019, 8, 1900342. [Google Scholar] [CrossRef]
  84. MyHealthyApple.com. Top Four Sweat Sensor Telated Features Coming Soon to Your Smartwatches. Available online: https://www.myhealthyapple.com/top-four-sweat-sensors-related-features-coming-soon-to-your-smartwatch/#What_are_sweat_sensors (accessed on 27 May 2021).
  85. Geneva, I.I.; Cuzzo, B.; Fazili, T.; Javaid, W. Normal Body Temperature: A Systematic Review. In Open Forum Infectious Diseases; Oxford University Press US: Cary, NC, USA, 2019; Volume 6, p. ofz032. [Google Scholar]
  86. F. MacDonald. This is How a Norwegian Woman Survived the Lowest Body Temperature Ever Recorded. Available online: https://www.sciencealert.com/this-woman-survived-the-lowest-body-temperature-ever-recorded (accessed on 27 May 2021).
  87. Thermometrics. Accuracy Standards. Available online: https://www.thermometricscorp.com/rtd-accuracy.html (accessed on 27 May 2021).
  88. Maxim Integrated. Max30205 Human Body Temperature Sensor. Available online: https://www.maximintegrated.com/en/products/interface/sensor-interface/MAX30205.html (accessed on 27 May 2021).
  89. Workerbase. First Smartwatch for Industrial Use. Available online: https://workerbase.com/industrial-smartwatch (accessed on 27 May 2021).
  90. Mohy-Ud-Din, Z.; Woo, S.H.; Lee, J.H.; Lee, S.H.; Young, P.S.; Won, C.H.; Cho, J.H. Wireless skin temperature sensing patch. In Proceedings of the IEEE International Conference on Multisensor Fusion and Integration for Intelligent Systems, Seoul, Korea, 20–22 August 2008; IEEE: Piscatvey, NJ, USA, 2008; pp. 258–260. [Google Scholar]
  91. Svertoka, E.; Bălănescu, M.; Suciu, G.; Pasat, A.; Drosu, A. Decision Support Algorithm Based on the Concentrations of Air Pollutants Visualization. Sensors 2020, 20, 5931. [Google Scholar] [CrossRef] [PubMed]
  92. Svertoka, E.; Rusu-Casandra, A.; Marghescu, I. State-of-the-Art of Industrial Wearables: A Systematic Review. In Proceedings of the 13th International Conference on Communications (COMM), Bucharest, Romania, 18–20 June 2020; IEEE: Piscatvey, NJ, USA, 2020; pp. 411–415. [Google Scholar]
  93. Cambridge Dictionary. Atmospheric Pressure. Available online: https://dictionary.cambridge.org/ru (accessed on 27 May 2021).
  94. Alex Yartsev. Deranged Physiology. Physiological Effects of High and Low Barometric Pressure. Available online: https://derangedphysiology.com/main/cicm-primary-exam/required-reading/respiratory-system/Chapter%20923/physiological-effects-high-and-low-barometric-pressure (accessed on 27 May 2021).
  95. Melamed, Y.; Shupak, A.; Bitterman, H. Medical problems associated with underwater diving. N. Engl. J. Med. 1992, 326, 30–35. [Google Scholar] [PubMed]
  96. Vandrico Inc. Atheer Air Glasses. Available online: https://vandrico.com/wearables/device/atheer-air-glasses.html (accessed on 27 May 2021).
  97. Maximum Yield. Light Intensity. Available online: https://www.maximumyield.com/definition/2036/light-intensity (accessed on 27 May 2021).
  98. National Optical Astronomic Observatory. Recommended Light Levels. Available online: http://www.noao.edu/education/QLTkit/ACTIVITY_Documents/Safety/LightLevels_outdoor+indoor.pdf (accessed on 27 May 2021).
  99. European Commission. Health and Consumers. Scientific Committees. Health Effects of Artificial Light. Available online: https://ec.europa.eu/health/scientific_committees/opinions_layman/artificial-light/en/l-2/4-effects-health.htm#0 (accessed on 27 May 2021).
  100. Nang, E.E.K.; Abuduxike, G.; Posadzki, P.; Divakar, U.; Visvalingam, N.; Nazeha, N.; Dunleavy, G.; Christopoulos, G.I.; Soh, C.K.; Jarbrink, K.; et al. Review of the Potential Health Effects of Light and Environmental Exposures in Underground Workplaces. Tunn. Undergr. Space Technol. 2019, 84, 201–209. [Google Scholar] [CrossRef]
  101. United States Department of Labor. Occupational Safety and Health Administration. Standard 1926.56—Illumination. Available online: https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.56 (accessed on 27 May 2021).
  102. Texas Instruments. OPT3006 Ultra-Thin Ambient Light Sensor. Available online: https://www.ti.com/product/OPT3006 (accessed on 27 May 2021).
  103. The Free Dictionary. Noise Level. Available online: https://www.thefreedictionary.com/noise+level (accessed on 27 May 2021).
  104. Talukdar, M. Noise Pollution and Its Control in Textile Industry; NISCAIR-CSIR: New Delhi, India, 2001. [Google Scholar]
  105. Cambridge Dictionary. Radiation. Available online: https://dictionary.cambridge.org/ru (accessed on 27 May 2021).
  106. U.S.NRC. Information for Radiation Workers. Available online: https://www.nrc.gov/about-nrc/radiation/health-effects/info.html (accessed on 27 May 2021).
  107. EPA. United States Environmental Protection Agency. Radiation Health Effects. Available online: https://www.epa.gov/radiation/radiation-health-effects (accessed on 27 May 2021).
  108. Banafa, A. The Internet of Everything. Discov. World Res. 2014. [Google Scholar] [CrossRef]
  109. Cambridge Dictionary. Relative Humidity. Available online: https://dictionary.cambridge.org/ru (accessed on 27 May 2021).
  110. Toftum, J.; Fanger, P.O. Air Humidity Requirements for Human Comfort. Ashrae Trans. 1999, 105, 641. [Google Scholar]
  111. Baughman, A.; Arens, E.A. Indoor Humidity and Human Health–Part I: Literature Review of Health Effects of Humidity-Influenced Indoor Pollutants. Ashrae Trans. 1996, 102, 192–211. [Google Scholar]
  112. Sensirion. Datasheet sht1x (sht10, sht11, sht15) Humidity and Temperature Sensor. Available online: https://www.sparkfun.com/datasheets/Sensors/SHT1x_datasheet.pdf (accessed on 27 May 2021).
  113. Milley, M.A.; O’Keefe, G.B. Mountain Warfare and Cold Weather Operations; Technical Report; Headquarters Department of the Army Washington United States: Washington, DC, USA, 2016.
  114. Cui, W.; Cao, G.; Park, J.H.; Ouyang, Q.; Zhu, Y. Influence of Indoor Air Temperature on Human Thermal Comfort, Motivation and Performance. Build. Environ. 2013, 68, 114–122. [Google Scholar] [CrossRef]
  115. World Health Organization. Radiation: The Ultraviolet (UV) Index. Available online: https://www.who.int/news-room/q-adetail/radiation-the-ultraviolet-(uv)-index (accessed on 27 May 2021).
  116. Vanicek, K.; Frei, T.; Litynska, Z.; Schmalwieser, A. UV-Index for the Public; Publication of the European Communities: Brussels, Belgium, 2000. [Google Scholar]
  117. Banerjee, S.; Hoch, E.G.; Kaplan, P.D.; Dumont, E.L. A Comparative Study of Wearable Ultraviolet Radiometers. In Proceedings of the IEEE Life Sciences Conference (LSC), Sydney, Australia, 13–15 December 2017; IEEE: Piscatvey, NJ, USA, 2017; pp. 9–12. [Google Scholar]
  118. Rapin, M.; Wacker, J.; Chételat, O. Cooperative Sensors: A New Wired Body-Sensor-Network Approach for Wearable Biopotential Measurement. In Proceedings of the 5th EAI International Conference on Wireless Mobile Communication and Healthcare, London, UK, 14–16 October 2015; pp. 151–154. [Google Scholar]
  119. Domingo, M.C. An Overview of the Internet of Things for People with Disabilities. J. Netw. Comput. Appl. 2012, 35, 584–596. [Google Scholar] [CrossRef]
  120. Orfanidis, C.; Dimitrakopoulos, K.; Fafoutis, X.; Jacobsson, M. Towards Battery-Free LPWAN Wearables. In Proceedings of the 7th International Workshop on Energy Harvesting and Energy-Neutral Sensing Systems, New York, NY, USA, 10 November 2019; pp. 52–53. [Google Scholar]
  121. Ometov, A.; Chukhno, O.; Chukhno, N.; Nurmi, J.; Lohan, E.S. When Wearable Technology Meets Computing in Future Networks: A Road Ahead. In Proceedings of the 18th ACM International Conference on Computing Frontiers, Virtual Event, Italy, 11–13 May 2021; pp. 185–190. [Google Scholar]
  122. Pyattaev, A.; Johnsson, K.; Andreev, S.; Koucheryavy, Y. Communication Challenges in High-Density Deployments of Wearable Wireless Devices. IEEE Wirel. Commun. 2015, 22, 12–18. [Google Scholar] [CrossRef]
  123. Kaul, A.; Wheelock, C. Enterprise Wearable Technology Case Studies. In White Paper; Tractica: Boulder, CO, USA, 2016. [Google Scholar]
  124. Gungor, V.C.; Hancke, G.P. Industrial Wireless Sensor Networks: Challenges, Design Principles, and Technical Approaches. IEEE Trans. Ind. Electron. 2009, 56, 4258–4265. [Google Scholar] [CrossRef] [Green Version]
  125. Bernal, G.; Colombo, S.; Al Ai Baky, M.; Casalegno, F. Safety++ Designing IoT and Wearable Systems for Industrial Safety through a User Centered Design Approach. In Proceedings of the 10th International Conference on PErvasive Technologies Related to Assistive Environments, Island of Rhodes, Greece, 21–23 June 2017; pp. 163–170. [Google Scholar]
  126. Bezzateev, S.; Afanasyeva, A.; Voloshina, N.; Ometov, A. Multi-Factor Authentication for Wearables: Configuring System Parameters with Risk Function. In Proceedings of the 2nd International Conference on Advanced Wireless Information, Data, and Communication Technologies, Lviv, Ukraine, 13–14 November 2017; pp. 1–7. [Google Scholar]
  127. Voigt, P.; Von dem Bussche, A. The EU General Data Protection Regulation (GDPR). InA Practical Guide, 1st ed.; Springer International Publishing: Cham, Switzerland, 2017; Volume 10, p. 3152676. [Google Scholar]
  128. Djapic, R.; Vivier, G.; Zhen, B.; Wang, J.; Lee, J.; Haiming, W. Wearables White Paper; TNO: Den Haag, The Netherlands, 2018. [Google Scholar]
  129. Fernández-Garcia, R.; Gil, I. An Alternative Wearable Tracking System Based on a Low-Power Wide-Area Network. Sensors 2017, 17, 592. [Google Scholar] [CrossRef] [Green Version]
  130. AlertGPS. AlertGPS Uses AT&T Connectivity to Help Keep Mobile Workers Safer. Available online: https://alertgps.com/wp-content/uploads/2018/04/AGPS-ATT-release-WorldSafetyDay2018-1.pdf (accessed on 27 May 2021).
  131. Saafi, S.; Hosek, J.; Kolackova, A. Cellular-Enabled Wearables in Public Safety Networks: State of the Art and Performance Evaluation. In Proceedings of the 12th International Congress on Ultra Modern Telecommunications and Control Systems and Workshops (ICUMT), Brno, Czech Republic, 5–7 October 2020; IEEE: Piscatvey, NJ, USA, 2020; pp. 201–207. [Google Scholar]
  132. Yang, P.; Wu, W.; Moniri, M.; Chibelushi, C.C. Efficient Object Localization Using Sparsely Distributed Passive RFID Tags. IEEE Trans. Ind. Electron. 2012, 60, 5914–5924. [Google Scholar] [CrossRef]
  133. Tei, R.; Yamazawa, H.; Shimizu, T. BLE Power Consumption Estimation and its Applications to Smart Manufacturing. In Proceedings of the 54th Annual Conference of the Society of Instrument and Control Engineers of Japan (SICE), Osaka, Japan, 28–30 July 2015; IEEE: Piscatvey, NJ, USA, 2015; pp. 148–153. [Google Scholar]
  134. Ometov, A. Short-Range Communications within Emerging Wireless Networks and Architectures: A Survey. In Proceedings of the 14th Conference of Open Innovation Association FRUCT, Helsinki, Finland, 11–15 November 2013; IEEE: Piscatvey, NJ, USA, 2013; pp. 83–89. [Google Scholar]
  135. Hayek, A.; Telawi, S.; Klos, J.; Börcsök, J.; Daou, R.A.Z. Smart Wearable System for Safety-Related Industrial IoT Applications. In Interoperability, Safety and Security in IoT; Springer: Berlin/Heidelberg, Germany, 2017; pp. 154–164. [Google Scholar]
  136. Wu, F.; Redouté, J.M.; Yuce, M.R. We-Safe: A Self-Powered Wearable IoT Sensor Network for Safety Applications Based on LoRa. IEEE Access 2018, 6, 40846–40853. [Google Scholar] [CrossRef]
  137. Tayeh, G.B.; Azar, J.; Makhoul, A.; Guyeux, C.; Demerjian, J. A Wearable LoRa-Based Emergency System for Remote Safety Monitoring. In Proceedings of the 2020 International Wireless Communications and Mobile Computing (IWCMC), Limassol, Cyprus, 15–19 June 2020; IEEE: Piscatvey, NJ, USA, 2020; pp. 120–125. [Google Scholar]
  138. Borkar, S.R. Long-Term Evolution for Machines (LTE-M). In LPWAN Technologies for IoT and M2M Applications; Elsevier: Amsterdam, The Netherlands, 2020; pp. 145–166. [Google Scholar]
  139. Zhang, Z.; Ma, X.; Zhu, T.; Liu, G. Design of a NB-IoT-based Wearable Monitoring System. In Proceedings of the 11th EAI International Conference on Mobile Multimedia Communications, Qingdao, China, 21–22 June 2018; European Alliance for Innovation (EAI): Ghent, Belgium, 2018; p. 250. [Google Scholar]
  140. GSMA. KT Pilots NB-IoT to Improve the Safety of Mountain and Water Sports. Available online: https://www.gsma.com/iot/mobile-iot-pilots-operator/kt/ (accessed on 27 May 2021).
  141. IEEE Publishes 802. 11ah™-2016 Standard Amendment Extending Range and Improving Energy Efficiency in the Sub 1 GHz Band. Available online: https://standards.ieee.org/news/2017/ieee802-11ah.html (accessed on 27 May 2021).
  142. Tian, L.; Santi, S.; Seferagić, A.; Lan, J.; Famaey, J. Wi-Fi HaLow for the Internet of Things: An Up-to-Date Survey on IEEE 802.11 ah Research. J. Netw. Comput. Appl. 2021, 2021, 103036. [Google Scholar] [CrossRef]
  143. Ometov, A.; Daneshfar, N.; Hazmi, A.; Andreev, S.; Carpio, L.F.D.; Amin, P.; Torsner, J.; Koucheryavy, Y.; Valkama, M. System-Level Analysis of IEEE 802.11 ah Technology for Unsaturated MTC Traffic. Int. J. Sens. Netw. 2018, 26, 269–282. [Google Scholar] [CrossRef]
  144. Shafi, M.; Molisch, A.F.; Smith, P.J.; Haustein, T.; Zhu, P.; De Silva, P.; Tufvesson, F.; Benjebbour, A.; Wunder, G. 5G: A Tutorial Overview of Standards, Trials, Challenges, Deployment, and Practice. IEEE J. Sel. Areas Commun. 2017, 35, 1201–1221. [Google Scholar] [CrossRef]
  145. Elbamby, M.S.; Perfecto, C.; Bennis, M.; Doppler, K. Toward Low-Latency and Ultra-Reliable Virtual Reality. IEEE Netw. 2018, 32, 78–84. [Google Scholar] [CrossRef] [Green Version]
  146. ur Rehman, O.; Javaid, N.; Bibi, A.; Khan, Z.A. Performance Study of Localization Techniques in Wireless Body Area Sensor Networks. In Proceedings of the IEEE 11th International Conference on Trust, Security and Privacy in Computing and Communications, Liverpool, UK, 25–27 June 2012; IEEE: Piscatvey, NJ, USA, 2012; pp. 1968–1975. [Google Scholar]
  147. European Global Navigation Satellite Systems Agency. GNSS User Technology Report. Available online: https://www.gsa.europa.eu/sites/default/files/uploads/technology_report_2020.pdf (accessed on 27 May 2021).
  148. U-BLOX M10: Ultra-Low Power GNSS for Small, High-Performance Trackers and Wearables. Available online: https://www.u-blox.com/en/blogs/tech/u-blox-m10-ultra-low-power-gnss-small-high-performance-trackers-and-wearables (accessed on 27 May 2021).
  149. Huang, B.; Liu, M.; Xu, Z.; Jia, B. On the Performance Analysis of WiFi Based Localization. In Proceedings of the IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), Calgary, AB, Canada, 15–20 April 2018; IEEE: Piscatvey, NJ, USA, 2018; pp. 4369–4373. [Google Scholar]
  150. Yang, C.; Shao, H.R. WiFi-based Indoor Positioning. IEEE Commun. Mag. 2015, 53, 150–157. [Google Scholar] [CrossRef]
  151. Gómez-de Gabriel, J.M.; Fernández-Madrigal, J.A.; López-Arquillos, A.; Rubio-Romero, J.C. Monitoring Harness Use in Construction with BLE Beacons. Measurement 2019, 131, 329–340. [Google Scholar] [CrossRef]
  152. Sun, J.; Gao, M.; Wang, Q.; Jiang, M.; Zhang, X.; Schmitt, R. Smart Services for Enhancing Personal Competence in Industrie 4.0 Digital Factory. Logforum 2018, 14, 51–57. [Google Scholar] [CrossRef]
  153. Mokhtari, G.; Anvari-Moghaddam, A.; Zhang, Q.; Karunanithi, M. Multi-Residential Activity Labelling in Smart Homes with Wearable Tags Using BLE Technology. Sensors 2018, 18, 908. [Google Scholar] [CrossRef] [Green Version]
  154. Daixian, Z.; Kechu, Y. Particle Filter Localization in Underground Mines Using UWB Ranging. In Proceedings of the Fourth International Conference on Intelligent Computation Technology and Automation, Shenzhen, China, 28–29 March 2011; IEEE: Piscatvey, NJ, USA, 2011; Volume 2, pp. 645–648. [Google Scholar]
  155. Qin, Y.; Wang, F.; Zhou, C. A Distributed UWB-based Localization System in Underground Mines. J. Netw. 2015, 10, 134. [Google Scholar] [CrossRef] [Green Version]
  156. Otim, T.; Díez, L.E.; Bahillo, A.; Lopez-Iturri, P.; Falcone, F. Effects of the Body Wearable Sensor Position on the UWB Localization Accuracy. Electronics 2019, 8, 1351. [Google Scholar] [CrossRef] [Green Version]
  157. Fargas, B.C.; Petersen, M.N. GPS-Free Geolocation Using LoRa in Low-Power WANs. In Proceedings of the Global Internet of Things Summit (GIOTS), Geneva, Switzerland, 6–9 June 2017; IEEE: Piscatvey, NJ, USA, 2017; pp. 1–6. [Google Scholar]
  158. Podevijn, N.; Plets, D.; Trogh, J.; Martens, L.; Suanet, P.; Hendrikse, K.; Joseph, W. TDoA-based Outdoor Positioning with Tracking Algorithm in a Public LoRa Network. Wirel. Commun. Mob. Comput. 2018, 2018, 1864209. [Google Scholar] [CrossRef]
  159. Islam, B.; Islam, M.T.; Nirjon, S. Feasibility of LoRa for Indoor Localization. Appl. Sci. 2017, 2017, 8565550. [Google Scholar]
  160. Janssen, T.; Aernouts, M.; Berkvens, R.; Weyn, M. Outdoor Fingerprinting Localization Using SigFox. In Proceedings of the International Conference on Indoor Positioning and Indoor Navigation (IPIN), Nantes, France, 24–27 September 2018; IEEE: Piscatvey, NJ, USA, 2018; pp. 1–6. [Google Scholar]
  161. Anagnostopoulos, G.G.; Kalousis, A. A Reproducible Analysis of RSSI Fingerprinting for Outdoor Localization Using SigFox: Preprocessing and Hyperparameter Tuning. In Proceedings of the International Conference on Indoor Positioning and Indoor Navigation (IPIN), Pisa, Italy, 30 September–3 October 2019; IEEE: Piscatvey, NJ, USA, 2019; pp. 1–8. [Google Scholar]
  162. Chae, S.; Yoshida, T. Application of RFID Technology to Prevention of Collision Accident With Heavy Equipment. Autom. Constr. 2010, 19, 368–374. [Google Scholar] [CrossRef]
  163. Kanan, R.; Elhassan, O.; Bensalem, R. An IoT-based Autonomous System for Workers’ Safety in Construction Sites with Real-Time Alarming, Monitoring, and Positioning Strategies. Autom. Constr. 2018, 88, 73–86. [Google Scholar] [CrossRef]
  164. Quuppa. Bluetooth Low Energy, Angle-of-Arrival, and the Magic Behind. Available online: https://quuppa.com/technology/overview/ (accessed on 27 May 2021).
  165. Cao, Z.; Chen, R.; Guo, G.; Pan, Y. iBaby: A Low Cost BLE Pseudolite Based Indoor Baby Care System. In Proceedings of the 2018 Ubiquitous Positioning, Indoor Navigation and Location-Based Services (UPINLBS), Wuhan, China, 22–23 March 2018; pp. 1–6. [Google Scholar]
  166. Rizos, C.; Lilly, B.; Robertson, C.; Gambale, N. Open Cut Mine Machinery Automation: Going Beyond GNSS with Locata. In Proceedings of the International Future Mining Conference, Sydney, Australia, 6–8 December 2011; Citeseer: Princeton, NJ, USA, 2011; pp. 22–23. [Google Scholar]
  167. Zimmerman, K.R.; Cobb, H.S.; Bauregger, F.N.; Alban, S.; Montgomery, P.Y.; Lawrence, D.G. A New GPS Augmentation Solution: Terralite’XPS System for Mining Applications and Initial Experience. In Proceedings of the 18th International Technical Meeting of the Satellite Division of The Institute of Navigation (ION GNSS 2005), Long Beach, CA, USA, 13–16 September 2005; pp. 2775–2788. [Google Scholar]
  168. Trunzo, A.; Benshoof, P.; Amt, J. The UHARS non-GPS based Positioning System. In Proceedings of the 24th International Technical Meeting of The Satellite Division of the Institute of Navigation (ION GNSS 2011), Portland, OR, USA, 19–23 September 2011; pp. 3582–3586. [Google Scholar]
  169. Seguel, F.; Soto, I.; Adasme, P.; Krommenacker, N.; Charpentier, P. Potential and Challenges of VLC based IPS in Underground Mines. In Proceedings of the First South American Colloquium on Visible Light Communications (SACVLC), Santiago, Chile, 13 November 2017; IEEE: Piscatvey, NJ, USA, 2017; pp. 1–6. [Google Scholar]
  170. Li, B.; Zhao, K.; Saydam, S.; Rizos, C.; Wang, Q.; Wang, J. Investigation of Indoor Positioning Technologies for Underground Mine Environments. In Proceedings of the IPIN (Short Papers/Work-in-Progress Papers), Pisa, Italy, 30 September–3 October 2019; IEEE: Piscatvey, NJ, USA, 2019; pp. 259–266. [Google Scholar]
  171. Niu, Q.; Yang, X.; Yin, Y. IPL: Image-Assisted Person Localization for Underground Coal Mines. Sensors 2018, 18, 3679. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  172. CDC. Basic Tutorial on Wireless Communication and Electronic Tracking: Technology Overview. Available online: https://www.cdc.gov/niosh/mining/content/emergencymanagementandresponse/commtracking/commtrackingtutorial1.html#23TrackingSystemsPrinciplesofOperation (accessed on 27 May 2021).
  173. Ouameur, M.A.; Caza-Szoka, M.; Massicotte, D. Machine Learning Enabled Tools and Methods for Indoor Localization Using Low Power Wireless Network. Internet Things 2020, 12, 100300. [Google Scholar] [CrossRef]
  174. Anjum, M.; Khan, M.A.; Hassan, S.A.; Mahmood, A.; Gidlund, M. Analysis of RSSI Fingerprinting in LoRa Networks. In Proceedings of the 15th International Wireless Communications & Mobile Computing Conference (IWCMC), Tangier, Morocco, 24–28 June 2019; IEEE: Piscatvey, NJ, USA, 2019; pp. 1178–1183. [Google Scholar]
  175. Li, S.; Qin, Z.; Song, H.; Si, C.; Sun, B.; Yang, X.; Zhang, R. A Lightweight and Aggregated System for Indoor/Outdoor Detection Using Smart Devices. Future Gener. Comput. Syst. 2020, 107, 988–997. [Google Scholar] [CrossRef]
  176. Adebomehin, A.; Walker, S. Enhanced Satellite Positioning Methods Using UltraWideband D2D-based Localization for Ultra-Dense 5G Wireless Setting. J. Physics: Conf. Ser. 2019, 1152, 012026. [Google Scholar] [CrossRef]
  177. Ranjan, A.; Misra, P.; Dwivedi, B.; Sahu, H.B. Studies on Propagation Characteristics of Radio Waves for Wireless Networks in Underground Coal Mines. Wirel. Pers. Commun. 2017, 97, 2819–2832. [Google Scholar] [CrossRef]
  178. Liu, G.; Chen, P. Design of Wireless Communication System in Mine. J. Phys. Conf. Ser. 2020, 1626, 012031. [Google Scholar] [CrossRef]
  179. Umetsu, Y.; Nakamura, Y.; Arakawa, Y.; Fujimoto, M.; Suwa, H. EHAAS: Energy Harvesters as a Sensor for Place Recognition on Wearables. In Proceedings of the IEEE International Conference on Pervasive Computing and Communications (PerCom), Kyoto, Japan, 11–15 March 2019; IEEE: Piscatvey, NJ, USA, 2019; pp. 1–10. [Google Scholar]
  180. Harkanson, R.; Kim, Y. Applications of Elliptic Curve Cryptography: A Light Introduction to Elliptic Curves and a Survey of their Applications. In Proceedings of the 12th annual conference on cyber and information security research, Oak Ridge, TN, USA, 4–6 April 2017; pp. 1–7. [Google Scholar]
  181. Ometov, A.; Masek, P.; Malina, L.; Florea, R.; Hosek, J.; Andreev, S.; Hajny, J.; Niutanen, J.; Koucheryavy, Y. Feasibility Characterization of Cryptographic Primitives for Constrained (Wearable) IoT Devices. In Proceedings of the IEEE International Conference on Pervasive Computing and Communication Workshops (PerCom Workshops), Pisa, Italy, 21–25 March 2016; IEEE: Piscatvey, NJ, USA, 2016; pp. 1–6. [Google Scholar]
  182. Ching, K.W.; Singh, M.M. Wearable Technology Devices Security and Privacy Vulnerability Analysis. Int. J. Netw. Secur. Its Appl. 2016, 8, 19–30. [Google Scholar] [CrossRef]
  183. Shubina, V.; Ometov, A.; Andreev, S.; Niculescu, D.; Lohan, E.S. Privacy versus Location Accuracy in Opportunistic Wearable Networks. In Proceedings of the 2020 International Conference on Localization and GNSS (ICL-GNSS), Tampere, Finland, 2–4 June 2020; IEEE: Piscatvey, NJ, USA, 2020; pp. 1–6. [Google Scholar]
  184. Shubina, V.; Holcer, S.; Gould, M.; Lohan, E.S. Survey of Decentralized Solutions with Mobile Devices for User Location Tracking, Proximity Detection, and Contact Tracing in the COVID-19 Era. Data 2020, 5, 87. [Google Scholar] [CrossRef]
  185. Shubina, V.; Ometov, A.; Niculescu, D.; Lohan, E.S. Challenges of Privacy-aware Localization on Wearable Devices. In Proceedings of the XXXV Finnish URSI Convention on Radio Science, Tampere, Finland, 20–25 August 2019. [Google Scholar]
  186. Shubina, V.; Ometov, A.; Basiri, A.; Lohan, E.S. Effectiveness Modelling of Digital Contact-Tracing Solutions for Tackling the COVID-19 Pandemic. J. Navig. 2021, 1–34. [Google Scholar] [CrossRef]
  187. Kim, K.J.; Shin, D.H. An Acceptance Model for Smart Watches. Internet Res. 2015, 25, 527–541. [Google Scholar] [CrossRef]
  188. Venkatesh, V.; Thong, J.Y.; Xu, X. Unified Theory of Acceptance and Use of Technology: A Synthesis and the Road Ahead. J. Assoc. Inf. Syst. 2016, 17, 328–376. [Google Scholar] [CrossRef]
  189. Jacobs, J.V.; Hettinger, L.J.; Huang, Y.H.; Jeffries, S.; Lesch, M.F.; Simmons, L.A.; Verma, S.K.; Willetts, J.L. Employee Acceptance of Wearable Technology in the Workplace. Appl. Ergon. 2019, 78, 148–156. [Google Scholar] [CrossRef]
  190. Kritzler, M.; Bäckman, M.; Tenfält, A.; Michahelles, F. Wearable Technology as a Solution for Workplace Safety. In Proceedings of the 14th International Conference on Mobile and Ubiquitous Multimedia, Linz, Austria, 30 November–2 December 2015; pp. 213–217. [Google Scholar]
  191. Younan, M.; Houssein, E.H.; Elhoseny, M.; Ali, A.A. Challenges and Recommended Technologies for the Industrial Internet of Things: A Comprehensive Review. Measurement 2020, 151, 107198. [Google Scholar] [CrossRef]
  192. Wang, F.; Zhang, X. Dynamic Computation Offloading and Resource Allocation Over Mobile Edge Computing Networks with Energy Harvesting Capability. In Proceedings of the IEEE International Conference on Communications (ICC), Kansas City, MO, USA, 20–24 May 2018; IEEE: Piscatvey, NJ, USA, 2018; pp. 1–6. [Google Scholar]
  193. Li, C.; Bai, J.; Tang, J. Joint Optimization of Data Placement and Scheduling for Improving User Experience in Edge Computing. J. Parallel Distrib. Comput. 2019, 125, 93–105. [Google Scholar] [CrossRef]
  194. Dionisi, A.; Marioli, D.; Sardini, E.; Serpelloni, M. Autonomous Wearable System for Vital Signs Measurement with Energy-Harvesting Module. IEEE Trans. Instrum. Meas. 2016, 65, 1423–1434. [Google Scholar] [CrossRef]
  195. Zhao, J.; Lin, Y.; Wu, J.; Nyein, H.Y.Y.; Bariya, M.; Tai, L.C.; Chao, M.; Ji, W.; Zhang, G.; Fan, Z.; et al. A Fully Integrated and Self-Powered Smartwatch for Continuous Sweat Glucose Monitoring. ACS Sens. 2019, 4, 1925–1933. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  196. Dohan, K. The Three Most Common Mining Industry Cyber Threats. Available online: https://www.nozominetworks.com/blog/the-three-most-common-mining-industry-cyber-threats/ (accessed on 27 May 2021).
  197. Nguyen, M.; Gani, M.O.; Raychoudhury, V. Yours Truly? Survey on Accessibility of our Personal Data in the Connected World. In Proceedings of the IEEE International Conference on Pervasive Computing and Communications Workshops (PerCom Workshops), Kyoto, Japan, 11–15 March 2019; IEEE: Piscatvey, NJ, USA, 2019; pp. 292–297. [Google Scholar]
  198. Taherdoost, H.; Sahibuddin, S.; Namayandeh, M.; Jalaliyoon, N.; Kalantari, A.; Chaeikar, S.S. Smart Card Adoption Model: Social and Ethical Perspectives. Science 2012, 3, 1792–1796. [Google Scholar]
Figure 1. The concept of using wearable devices in industries to maintain work safety.
Figure 1. The concept of using wearable devices in industries to maintain work safety.
Sensors 21 03844 g001
Figure 2. The rate of deaths due to work-related accidents during 2014–2020 (for approx. 100,000).
Figure 2. The rate of deaths due to work-related accidents during 2014–2020 (for approx. 100,000).
Sensors 21 03844 g002
Table 1. Classification of industrial wearable functions.
Table 1. Classification of industrial wearable functions.
FunctionSub-Functions & Description
Monitoring (M) Fitness trackers, smart rings, smart glasses, patches/ sensors attached to the body, smart clothing, implantable wearables, etc.Monitoring and control of vital parameters of workers. Information about vital parameters (heart rate, blood pressure, body temperature, brain activity, etc.) gives the employer (organization, safety manager, administration) and the worker himself an idea on the readiness of the latter for the work process from a physical, less often psychological, point of view [31,32].
Monitoring of environmental parameters at workplaces. Knowing such parameters as the temperature at the worksite, atmospheric pressure, level of radiation, and so on allows an organization to control the overall environmental situation at the factory, prevent emergencies, timely organize the evacuation of people, provide a worker with proper Personal Protective Equipment (PPE). Moreover, by combining environmental and vital parameters, it is possible to track environmental impacts on human health in hazardous industries such as the chemical industry [33,34].
Supporting (S) Exoskeletons, patches (to control the position of the body when lifting heavy objects), wearable robotsIncreasing the physical capabilities of the workers. Some industries envisage lifting and transferring heavy objects, which is often associated with musculoskeletal injuries. Wearable items such as exoskeletons support the musculoskeletal system to prevent damage [35,36,37].
Facilitating communication between workers. Due to their small size, weight, and comfortable attachment to the wearer’s body, wearables such as headsets with embedded hand-free microphones, for example, are much more convenient than phones and able to provide communication between workers without distracting them from the work process. (hand-free microphones embedded in headsets/helmets) [38].
Simplification of information management. Wearable devices provide secure transmitting, storage, displaying information, and fast access to documents and notifications [39].
Performing industrial design. The use of AR enables creating virtual diagrams and graphs that facilitate better understanding by workers [40].
Training (Tn) Smart glasses, helmets, heads-up displayTraining of the workers. Some wearable devices can track the correctness of the actions performed by the worker, providing him with a detailed report (for example, determining the correct posture using biomechanical analysis). The worker can analyze his mistakes to prevent them in the future. Moreover, using Virtual Reality (VR) and Augmented Reality (AR) helmets, it is possible to train workers on complicated operations before performing them in reality, thereby reducing the likelihood of injury [36,40].
Tracking (Tc) Smart bracelets, smart clothes, smart boots, digital pedometer, etc.Monitoring of location parameters of workers. The worker’s location is one of the most important parameters when we are talking about ensuring work safety in the industry. By knowing each employee’s location, the safety manager can efficiently organize evacuations, distribute help and workforce, prevent unauthorized access to the worksite or equipment, and so on [41].
Preventing struck by moving machinery. Tracking of object locations and proximity detection sensors allow avoiding a collision that is one of the most spread accidents in industries [33,41].
Creating a comprehensive picture of the whole production process. Thanks to wearables, managers can see the real-time location of workers and equipment, which allows them easily redistribute labor between operating sites and more effectively allocate resources [41].
Table 2. Industry branches and inherent industrial wearable functions.
Table 2. Industry branches and inherent industrial wearable functions.
Industry BranchFunctions (See Table 1)Examples of Applications
MiningM, TcUS-based Guardhat to prevent injuries combining rugged helmets with microphones, cameras, and track sensors [42]. Guardhat is currently integrated into a lot of mining operations.
ChemicalM, TcMyExposome developed wristbands that can detect chemical exposures during the day [34].
Forest products, constructionM, Tc, SSolePower company released smart boots [41]. It is equipped with many various modules, particularly GPS and RFID, to determine the wearer’s location. Besides, they are very durable, so they can easily withstand many ordinary adverse external influences.
Crude oil productionMSmart Helmet by VRMedia Srl. was applied by the third-largest oil and gas service company in the world Baker Hughes to reduce downtime and increase safety at the workplace [43].
Transportation, ShippingM, Tc, SKinetic presents a wearable device called REFLEX that is equipped with sensors and modules performing biomechanical analysis [36]. It is worn on the belt or waistband and can determine whether the posture is correct or not and notify the user by vibration when risky movements arise.
Table 3. Human body-related metrics.
Table 3. Human body-related metrics.
MetricDescriptionExample AccuracyExamples
Blood pressureThe pressure that blood puts on the walls of blood vessels. There are systolic or upper (normal value: less than 120 mmHg) and diastolic or lower (normal value: less than 80 mmHg) blood pressure [45]. The average working range of blood pressure sensors is 0–320 mmHg [46,47].86% [48]Arm cuffs with attached sensors [49], cuff-less blood pressure sensors [50]
CalorieA unit equal to the amount of heat needed to increase one gram of water temperature by one degree Celsius. There are several ways how to calculate the number of calories (e.g., based on the number of steps or heart rate [51]), resulting in a wide range of wearables providing this function.>91% (walking); >90% (running) [52]Accelerometers, pressure sensors in fitness bracelets, smart shoes [51], etc.
Electro- cardiogram (ECG)The electrical activity of the heart [49]. The unit of measurement is Volts. ECG is the main diagnostic method for detecting cardiovascular diseases such as hypertrophy, heart attack, arrhythmia [53].>90% [54]Skin electrodes [49] in clothes [55], chest straps [56], etc.
Electro- encephalo- gram (EEG)The electrical activity of the brain [57]. The unit of measurement is Volts. EEG is used to identify and predict brain-related diseases (e.g., Alzheimer’s disease, epilepsy, dementia) [58]. In addition, it also used for the emotion detection [59,60]. Until now, ECG, EEG, and EMG are performed mainly in medical institutions. However, there are already some wearable devices on the market for such measurements.>86% [59,60]Headset [57,61]
Electro- myography (EMG)The electrical activity of the muscles [49]. The unit of measurement is Volts. When measuring EMG, the critical point is the exact position of the electrodes on the muscles. EMG is used to identify the muscle traumas and monitor the recovery tendency after such traumas [62].>90% [63]Skin electrodes [49] embedded in bracelets, waist straps [64], clothes [65].
GlucoseThe level of sugar in the blood. It is measured in grams per liter or moles per liter. High glucose level identifies diabetes, the symptoms of which are quite wide, ranging from visual impairment to increased fatigue and depressive episodes [66,67]>95% [68]Strip-base [69], implantable [70] glucose sensors, smart tattoos [71]
Heart rate and pulseHeart rate is the number of heartbeats per minute. Pulse is the number of vibrations of the aortic walls. Pulse may be a less accurate characteristic in pathologies (for example, extrasystole) since not all heartbeats lead to the formation of a pulse wave [72]. Critical boundaries usually range between 40-200 beats per minute and depend on current activity, gender, age, health, type of activity, etc.>76% [73]Pulse oximeter [74], chest [75] and wrist straps [69], fitness bracelets
Heart soundsSounds that appear due to a change in blood flow, vibration of the surrounding tissues of the heart, and large vessels. The conventional way to measure heart sounds is phonocardiograph [76]. However, there are already some wearable solution [77].>80% [77]Wrist band [77]
Location- related metricsMetrics related to identifying the object’s position: coverage, accuracy, power consumption, price of the wireless technology, etc. Localization technologies are considered in more detail in Section 3.3.NAWide range of wearables
Motion- related metricsThis metric refers to identifying the parameters of the human movements that are also called biomechanical analysis [78,79]. The range of the wearables for which this metric is used is very wide since the measured parameters could be very different: from detection of the velocity and speed to determining if the posture correct or not.NAAccelerometer, gyroscope [80], exoskeletons, pressure insoles, e-textile [78]
Perspiration or sweatA liquid excreted from the skin’s sweat glands [81]. Sweat is the second body fluid after the blood that contains the richest range of biomarkers like glucose, pH, cortisol, etc. [82]. Usually, this metric is used in sport or healthcare areas.>99% [83]Sweat collectors, skin patches [82], smart watches [84]
TemperatureA measure of the ability of the body to generate heat [49]. However, the normal temperature range for a healthy human is 36.16–37.02 °C [85], and the widest recorded range is 24–44 °C [86], usually the range of the wearables measuring temperature is wider.>99% [87]Temperature sensors [88,89] and skin patches [90]
NA—Accuracy is not specified for metric groups.
Table 4. Environment-related metrics.
Table 4. Environment-related metrics.
MetricDescriptionExamples
Air Quality Index (AQI)An index shows the degree of air pollution in a certain area [91]. It is calculated based on measured concentrations of pollutants and government-set limits for those concentrations. The list of measured pollutants can include ozone, carbon monoxide, sulfur dioxide, nitrogen dioxide, dust, etc. The possible values of the index are between 0 to 500. The scale is divided into ranges, usually 5 or 6, each corresponding to a specific air quality rating, from good to hazardous. The influence of high AQI levels (101 and above) on the human body varies depending on the predisposition (great age, heart/lung diseases), and could lead to such diseases as lung cancer, stroke, pneumonia, etc. [91]Gas sensors (e.g. CO2 sensor [92])
Atmospheric pressureThe pressure exerted by the weight of the atmosphere on the surface (of the Earth or another planet) below it [93]. This metric is necessary for jobs in low (pilots) or high (divers) barometric pressure conditions. On average, the measurement range of pressure sensors is from 300 to 1100 hPa with an error of 0.5 hPa. Extra low or extra high atmospheric pressure cause respiratory, heart, neurological changes, barotraumas, decompression illness, etc. [94,95]BMPxxx sensor group [92], barometers embedded in bands, smartwatches, glasses [96], etc.
Light intensityThe strength of light produced by a specific lamp source measured in lux [97]. The light intensity’s recommended levels in different cases can be found in the document issued by the National Optical Astronomic Observatory [98]. Both excessive and insufficient lighting in the workplace can lead to visual impairment. A wide range of health effects of lighting is observed in working conditions at night or in underground sites, including various types of cancer, irregular sleeping habits, and cardiovascular disorders [99,100]. Significantly, an insufficient illumination intensity is considered as causing an additional increase in the rate of accidents in low-light environments, such as construction areas, warehouses, and tunnels [101].Motion, traffic, ambient light sensors [20], e.g. [102]
Noise levelThe amplitude level of the undesired background sound [103] is measured in dBA. Constant sound above 80 dBA leads to the physiological effects and above 100 dbA—to the hearing damage, [104].Sound sensors, dynamic microphones [20]
RadiationAn energy from a nuclear reaction [105]. Nowadays, it is measured in Sv (Sievert). However, rem (roentgen equivalent man) units also could be found in the literature. US Nuclear Regulatory Commission has set a radiation limit of 5 rem or 0.05 Sv [106]. Even an acceptable level of radiation during a long period of time (what is typical for radiation industry employees) can be a reason for irreversible changes in the body, in particular, the risk of cancer increases. High doses lead to the vomit, skin burns, can cause death [107]Radiation detectors [108]
Relative HumidityThe amount of water that is present in the air compared to the greatest amount it would be possible for the air to hold at that temperature [109]. The hygienic norm of relative humidity for humans is 30–60%. With low humidity, the body becomes dehydrated, and the risk of bacteria entering the human organism increases. High humidity can cause overheating, increased perspiration rate, and promotes the appearance of allergens (mold, fungi, dust mites) [110,111].Temperature/humidity sensors [112]
TemperatureAmbient temperature, which is most often expressed in degrees Celsius. The the typical range of temperature sensors is −40 to 125 degrees Celsius °C [82]. The survival limit for the person is between −40 °C [113] and 48 °C. For the best performance the optimal ambient temperature is 22–26 °C [114].,Temperature/humidity sensors [82,112]
Ultraviolet index (UVI)An index shows the degree of ultraviolet radiation from the sun at a particular time and place. For measuring UVI World Health Organisation (WHO) proposed a linear scale beginning from 0 and without an upper border. There are 5 ranges: low (UV: 1–2), moderate (3–5), high (6–7), very high (8–10), extreme (11+) [115]. The sun exposure with UV higher than 7 can lead to serious damage of eyes (e.g., snowblindness), skin (burns, skin cancer, skin aging), and overall immune system [116].UV radiometers and dosimeters embedded in wrist bands, smartwatches, clips, etc. [117]
Table 6. Comparison of localization solutions.
Table 6. Comparison of localization solutions.
Technology ReferencesLocalization TechniquesTypical env-t.AccuracyAdditional Details
GNSS [147]Time-basedOutdoorcm-levelGlobal, not applicable indoors, still considered as high consuming for industrial wearabes, however, some companies already started to present ultra-low power GNSS [148]
Wi-Fi [149,150]Time-based, Angle-based, Power-basedIndoorm-levelNowadays, Wi-Fi fingerprinting (FP) is one of the most promising localization approaches for industrial wearables due to good accuracy and relatively low cost. The disadvantage of this approach is high consumption in terms of power and efforts spending on the training step
BLE [151]Time-based, Power-basedIndoorm-levelAnother perspective technology for indoor localization in IIoT [152] with such advantages as easy deployment, low cost, and low power consumption. However, the accuracy of the method is not very high, and supplementary algorithms are required to improve it [153].
UWB [150,154]Time-based, Angle-basedIndoorcm-levelThis method provides the highest accuracy of the localization, requires not much power, has immunity to fading, applicable even in the case of underground worksites. However, it is hard to deploy [155,156].
LoRa [157,158]Time-based, Power-basedOutdoor100 m-levelThe key advantages of this technology are coverage range (up to 20 km), low consumption, bigger stability than in case of WiFi and BLE [159]. However, low accuracy prevents the spread of the technology as a localization solution.
Sigfox [160,161]Power-basedOutdoor100 m-levelAdvantages and disadvantages are similar to LoRaWAN technology.
RFID [132,162,163]Power-basedIndoorcm-levelThis technology ensures high precision but in a low range (approx. 15 m).
Angle-basedIndoorm-levelLess accurate than passive RFID but has bigger range (approx. 150 m).
Table 7. Key challenges in the adoption of industrial wearables.
Table 7. Key challenges in the adoption of industrial wearables.
ChallengeGroupsRefs.Possible solutions
Localization accuracy indoors/outdoorsT[173,174]Applying of ML algorithms to identify missing values, predict the number of obstacles and distance between RX and TX
[175,176]Seamless localization to provide smooth tracking both indoor and outdoor
Connectivity solutions and propagation models for underground work sitesT[177,178]Application requirement-based selection of connectivity solutions, developing of empirical and industrial environment-specific propagation models with on-body/off-body/body-to-body communications
Power consumption and supply of a big amount of devicesT[136,179]Energy harvesting approaches: harvesting from the sunlight, motions, temperature gradients, etc.
Privacy and securityT, S, D[180,181]Elliptic Curve Cryptography (ECC) and other lightweight cryptography
[182]Development of strong authentication schemes
Location data privacyS, D[183,184]Adding noise to the exact coordinates on the device side before transmitting it to the cloud
[185,186]Transmission of the location-related function instead of the coordinates
Social resistanceS[18,92]Development of the simple and detailed manual, video guidance and provision of the constant support to eliminate the problem of low technical skills of users;
[187,188]Usage of Technology Acceptance Models (TAM) to estimate key factors affecting the level of social resistance and rearrange the process implementation of the technology accordingly
[189]Involving of the employees in the process of the choice of wearables
[190]Data flows transparency
Heterogeneity of the IIoT devicesD, SD[191]Application of the data fusion approaches on the hardware level, seamless integration on the protocol level
Placement of preprocessing and processing entitiesD[192,193]Optimization of data placement, dynamic computation resource allocation, computation offloading techniques.
High cost of wearables and its coupling with other technology in big industriesE[18]Development of one-size wearable to be used for data acquisition by different workers during different shifts
D—Data-related; E—Economic; S—Social; SD–Standard-related; T—Technological.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Svertoka, E.; Saafi, S.; Rusu-Casandra, A.; Burget, R.; Marghescu, I.; Hosek, J.; Ometov, A. Wearables for Industrial Work Safety: A Survey. Sensors 2021, 21, 3844. https://doi.org/10.3390/s21113844

AMA Style

Svertoka E, Saafi S, Rusu-Casandra A, Burget R, Marghescu I, Hosek J, Ometov A. Wearables for Industrial Work Safety: A Survey. Sensors. 2021; 21(11):3844. https://doi.org/10.3390/s21113844

Chicago/Turabian Style

Svertoka, Ekaterina, Salwa Saafi, Alexandru Rusu-Casandra, Radim Burget, Ion Marghescu, Jiri Hosek, and Aleksandr Ometov. 2021. "Wearables for Industrial Work Safety: A Survey" Sensors 21, no. 11: 3844. https://doi.org/10.3390/s21113844

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop