Next Article in Journal
Voltage and Deflection Amplification via Double Resonance Excitation in a Cantilever Microstructure
Previous Article in Journal
Design of Acoustical Bessel-Like Beam Formation by a Pupil Masked Soret Zone Plate Lens
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Reduce Calibration Time in Motor Imagery Using Spatially Regularized Symmetric Positives-Definite Matrices Based Classification

School of Fundamental Sciences, Massey University, Manawatu Private Bag 11 222, Palmerston North 4442, New Zealand
*
Author to whom correspondence should be addressed.
Sensors 2019, 19(2), 379; https://doi.org/10.3390/s19020379
Submission received: 11 December 2018 / Revised: 28 December 2018 / Accepted: 14 January 2019 / Published: 17 January 2019
(This article belongs to the Section Biosensors)

Abstract

Electroencephalogram (EEG) based motor imagery brain–computer interface (BCI) requires large number of subject specific training trials to calibrate the system for a new subject. This results in long calibration time that limits the BCI usage in practice. One major challenge in the development of a brain–computer interface is to reduce calibration time or completely eliminate it. To address this problem, existing approaches use covariance matrices of electroencephalography (EEG) trials as descriptors for decoding BCI but do not consider the geometry of the covariance matrices, which lies in the space of Symmetric Positive Definite (SPD) matrices. This inevitably limits their performance. We focus on reducing calibration time by introducing SPD based classification approach. However, SPD-based classification has limited applicability in small training sets because the dimensionality of covariance matrices is large in proportion to the number of trials. To overcome this drawback, our paper proposes a new framework that transforms SPD matrices in lower dimension through spatial filter regularized by prior information of EEG channels. The efficacy of the proposed approach was validated on the small sample scenario through Dataset IVa from BCI Competition III. The proposed approach achieved mean accuracy of 86.13 % and mean kappa of 0.72 on Dataset IVa. The proposed method outperformed other approaches in existing studies on Dataset IVa. Finally, to ensure the robustness of the proposed method, we evaluated it on Dataset IIIa from BCI Competition III and Dataset IIa from BCI Competition IV. The proposed method achieved mean accuracy 92.22 % and 81.21 % on Dataset IIIa and Dataset IIa, respectively.
Keywords: motor imagery; symmetric positives definite matrices; brain-computer interface (BCI); electroencephalography (EEG); Riemannian manifold motor imagery; symmetric positives definite matrices; brain-computer interface (BCI); electroencephalography (EEG); Riemannian manifold

Share and Cite

MDPI and ACS Style

Singh, A.; Lal, S.; Guesgen, H.W. Reduce Calibration Time in Motor Imagery Using Spatially Regularized Symmetric Positives-Definite Matrices Based Classification. Sensors 2019, 19, 379. https://doi.org/10.3390/s19020379

AMA Style

Singh A, Lal S, Guesgen HW. Reduce Calibration Time in Motor Imagery Using Spatially Regularized Symmetric Positives-Definite Matrices Based Classification. Sensors. 2019; 19(2):379. https://doi.org/10.3390/s19020379

Chicago/Turabian Style

Singh, Amardeep, Sunil Lal, and Hans W. Guesgen. 2019. "Reduce Calibration Time in Motor Imagery Using Spatially Regularized Symmetric Positives-Definite Matrices Based Classification" Sensors 19, no. 2: 379. https://doi.org/10.3390/s19020379

APA Style

Singh, A., Lal, S., & Guesgen, H. W. (2019). Reduce Calibration Time in Motor Imagery Using Spatially Regularized Symmetric Positives-Definite Matrices Based Classification. Sensors, 19(2), 379. https://doi.org/10.3390/s19020379

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop