Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (5)

Search Parameters:
Keywords = strong-column-weak-beam structural systems

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
20 pages, 4203 KB  
Article
Experimental Study on Seismic Behavior of Novel Prefabricated RC Joints with Welded Cover-Plate Steel Sleeve and Bolted Splice
by Dong-Ping Wu, Kang Rao, Wei Wei, Fei Han and Sheng Peng
Buildings 2025, 15(24), 4579; https://doi.org/10.3390/buildings15244579 - 18 Dec 2025
Viewed by 374
Abstract
In order to ensure the structural safety and serviceability of existing reinforced concrete (RC) structures, there is a compelling need to develop efficient techniques for the rapid replacement of damaged RC beams within strong-column–weak-beam structural systems. This study introduces a novel prefabricated RC [...] Read more.
In order to ensure the structural safety and serviceability of existing reinforced concrete (RC) structures, there is a compelling need to develop efficient techniques for the rapid replacement of damaged RC beams within strong-column–weak-beam structural systems. This study introduces a novel prefabricated RC beam with welded cover-plate steel sleeve and bolted splice designed to facilitate accelerated replacement and enhance construction efficiency. The proposed beam is connected to cast-in-place RC columns, forming a prefabricated novel prefabricated RC joint with a welded cover-plate steel sleeve and a bolted splice; this configuration contrasts with conventional monolithic RC joints, which are formed by integrally casting beams and columns. The assembly speed of the prefabricated system markedly surpasses that of its cast-in-place counterpart, and the resulting beam–column system is fully demountable. Finite element simulations of the novel prefabricated RC joint with welded cover-plate steel sleeve and bolted splice, performed using ABAQUS, identified the thickness of the welded end-plate as a pivotal parameter influencing the joint’s mechanical behavior. Accordingly, quasi-static tests were carried out on three novel prefabricated RC joints with welded cover-plate steel sleeves and bolted splices and one cast-in-place RC joint, with the welded end-plate thickness serving as the primary test variable. The failure patterns, hysteretic responses, energy dissipation capacity, ductility, and stiffness degradation were systematically analyzed. Experimental findings indicate that increasing the end-plate thickness effectively improves both the peak load-bearing capacity and the ductility of the joint. All prefabricated specimens exhibited fully developed spindle-shaped hysteresis loops, with ductility coefficients ranging from 3.47 to 3.64 and equivalent viscous damping ratios exceeding 0.13. All critical seismic performance metrics either met or exceeded those of the reference cast-in-place RC joint, affirming the reliability and superior behavior of the proposed novel prefabricated RC joints with welded cover-plate steel sleeves. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

21 pages, 6909 KB  
Article
Numerical Study Regarding the Seismic Response of a Moment-Resisting (MR) Reinforced Concrete (RC) Frame Structure with Reduced Cross-Sections of the RC Slabs
by Ion Sococol, Petru Mihai, Tudor-Cristian Petrescu, Florin Nedeff, Valentin Nedeff, Maricel Agop and Bogdan-Ionel Luca
Buildings 2022, 12(10), 1525; https://doi.org/10.3390/buildings12101525 - 23 Sep 2022
Cited by 5 | Viewed by 2601
Abstract
In the first part of the current study, the effectiveness of the transversal cross-section reduction method for RC beams in marginal areas (by means of mechanical drilling) was validated. The said method “encourages” the formation of plastic hinges at the beam ends and, [...] Read more.
In the first part of the current study, the effectiveness of the transversal cross-section reduction method for RC beams in marginal areas (by means of mechanical drilling) was validated. The said method “encourages” the formation of plastic hinges at the beam ends and, at the same time, allows for taking into account the bending stiffness of RC slabs, which is exerted upon the RC beams. In these conditions, the second part of the current research study (i.e., the current manuscript) highlights the real mode of reducing the lateral stiffness of the slabs upon the RC beams. These elements form a common body, together with the beam–column frame node. The same method as in the first part of the study—“weakening” the plates in the corner area through vertical drilling, without affecting the integrity of the reinforcing elements—was used. The analytical MR RC frame model, studied by means of the comparative method, highlights the efficiency of the transversal cross-section reduction method for RC slabs. Basically, the directing of the plastic deformations from the weakened slab areas towards the marginal areas of the reinforced concrete beams takes place. The beams rotate as far as the weakened slab areas allow its plastic deformation, thus being possible to observe the partial conservation effect of the beam–column frame joint. Furthermore, for the analytical model with the maximum number of vertical holes in the corner areas of the concrete plate, minimal plastic deformations are recorded for the marginal areas of the concrete columns. A partial conservation of the formation mechanism of the “beam-slab-frame node” common rigid block is also noted. Consequently, the dissipation of the seismic energy is made in a partially controlled and directed manner, in the “desired” areas, according to the “Strong Columns—Weak Beams” (SCWB) ductile mechanism of the lateral behavior to seismic actions for reinforced concrete frame structures. The mechanism is specified in current design norms for RC frame systems. The effectiveness of the method for reducing the transversal section of the RC plates in the corner areas by means of transversal drilling is highlighted and validated from the perspective of the local and global ductile seismic response of reinforced concrete frame structures. A significant reduction in the bending stiffness of the slabs upon the beams and a real development of the plastic hinges in the marginal areas of the beams (together with partial implications and plastic deformations) were observed. Full article
Show Figures

Figure 1

29 pages, 10506 KB  
Article
On the Seismic Evaluation of Steel Frames Laterally Braced with Perforated Steel Plate Shear Walls Considering Semi-Rigid Connections
by Arsalan Majlesi, Hamid Asadi-Ghoozhdi, Omid Bamshad, Reza Attarnejad, Amir R. Masoodi and Mehdi Ghassemieh
Buildings 2022, 12(9), 1427; https://doi.org/10.3390/buildings12091427 - 11 Sep 2022
Cited by 8 | Viewed by 3490
Abstract
Steel plate shear walls usually do not satisfy the strong-column weak-beam design criteria, leading to larger column sections. On the other hand, rigid frame structures are typically constructed in low-rise to mid-rise buildings built in locations prone to strong earthquakes due to their [...] Read more.
Steel plate shear walls usually do not satisfy the strong-column weak-beam design criteria, leading to larger column sections. On the other hand, rigid frame structures are typically constructed in low-rise to mid-rise buildings built in locations prone to strong earthquakes due to their high flexibility and cost-effective solutions. Overcoming these restrictions to the SPSW system, this paper is dedicated to employing a semi-rigid connection that dissipates energy well and reduces the forces applied to the structure. By using a semi-rigid connection in an adjacent span to the SPSW, the actual flexural capacity of the beam end decreases and, subsequently, improves the performance of the structure in terms of the of the strong-column weak-beam criteria. Thereupon, the impact of the semi-rigid connections on steel frames with SPSWs as a sideway resisting system can be assessed by implementing a numerical study. In this paper, a new methodology for modelling semi-rigid joints is used considering five connections with different moment capacities. Moreover, the influence of three different circular diameters on the behavior of the perforated SPSWs was investigated. To fulfil these purposes, nonlinear dynamic analysis was conducted to assess the reliability of 5-, 10-, and 15-story frames resisted with SPSWs and semi-rigid connections subjected to actual ground motion records. A total of 45 frames were modelled and the obtained results were compared with reference benchmarks. The outcomes of the studies show good agreement with design building code requirements. In addition, the reliable performance of the structure under seismic loads is evaluated. According to the results of the parametric study, the presumed allowable drift leads to obtaining the optimum moment capacity of connection for each model and illustrates the applicability of a new structural system consisting of SPSWs and semi-rigid connections simultaneously. Full article
(This article belongs to the Special Issue Advances in the Behaviour of Steel Structures)
Show Figures

Figure 1

21 pages, 11122 KB  
Article
Structural Performance of a New Blind-Bolted Frame Modular Beam-Column Connection under Lateral Loading
by Bong-Ho Cho, Jae-Sub Lee, Hongjin Kim and Dae-Jin Kim
Appl. Sci. 2019, 9(9), 1929; https://doi.org/10.3390/app9091929 - 10 May 2019
Cited by 51 | Viewed by 7671
Abstract
This study proposes an effective steel frame modular system and evaluates the structural performance of its beam-column connection through experimental and analytical work. The new steel frame modular system utilizes the blind bolts, which allow free access to the structural members of the [...] Read more.
This study proposes an effective steel frame modular system and evaluates the structural performance of its beam-column connection through experimental and analytical work. The new steel frame modular system utilizes the blind bolts, which allow free access to the structural members of the closed cross-section. In addition, the new modular system is designed such that the strength of its beam members is considerably lower than that of its column members to implement the strong column-weak beam concept. In order to investigate the effectiveness of the proposed modular beam-column connection, two types of specimens were designed and tested. One of the two specimens has four knee brace members to increase the bending stiffness of the connection, while the other does not have these components. The applied load versus displacement curves are plotted for the two specimens, and their failure modes are identified. Finally, a simplified analytical model for the modular beam-column connection is proposed, and its effectiveness is validated by performing its push-over analysis and comparing its results with the test results. Full article
(This article belongs to the Special Issue Selected Papers from IMETI 2018)
Show Figures

Figure 1

16 pages, 4107 KB  
Article
Seismic Failure Mechanism of Reinforced Cold-Formed Steel Shear Wall System Based on Structural Vulnerability Analysis
by Jihong Ye, Liqiang Jiang and Xingxing Wang
Appl. Sci. 2017, 7(2), 182; https://doi.org/10.3390/app7020182 - 22 Feb 2017
Cited by 20 | Viewed by 10114
Abstract
A series of structural vulnerability analyses are conducted on a reinforced cold-formed steel (RCFS) shear wall system and a traditional cold-formed steel (CFS) shear wall system subjected to earthquake hazard based on forms in order to investigate their failure mechanisms. The RCFS shear [...] Read more.
A series of structural vulnerability analyses are conducted on a reinforced cold-formed steel (RCFS) shear wall system and a traditional cold-formed steel (CFS) shear wall system subjected to earthquake hazard based on forms in order to investigate their failure mechanisms. The RCFS shear wall adopts rigid beam-column joints and continuous concrete-filled CFS tube end studs rather than coupled-C section end studs that are used in traditional CFS shear walls, to achieve the rigid connections in both beam-column joints and column bases. The results show that: the RCFS and traditional CFS shear wall systems both exhibit the maximum vulnerability index associated with the failure mode in the first story. Therefore, the first story is likely to be a weakness of the CFS shear wall system. Once the wall is damaged, the traditional CFS shear wall system would collapse because the shear wall is the only lateral-resisting component. However, the collapse resistance of the RCFS shear wall system is effectively enhanced by the second defense, which is provided by a framework integrated by rigid beam-column joints and fixed column bases. The predicted collapse mode with maximum vulnerability index that was obtained by structural vulnerability analysis agrees well with the experimental result, and the structural vulnerability method is thereby verified to be reasonable to identify the weaknesses of framed structures and predict their collapse modes. Additionally, the quantitative vulnerability index indicates that the RCFS shear wall system exhibits better robustness compared to the traditional one. Furthermore, the “strong frame weak wallboard” and the “strong column weak beam” are proposed in this study as conceptional designations for the RCFS shear wall systems. Full article
(This article belongs to the Special Issue Applications of Thin-Walled Structures)
Show Figures

Figure 1

Back to TopTop