35 pages, 5834 KB  
Article
Recovery and Utilization of Flash Steam from Rotary Desiccant Regeneration in Dry Room HVAC Systems
by Kyu Hwa Jung and Young Il Kim
Energies 2026, 19(9), 2127; https://doi.org/10.3390/en19092127 - 28 Apr 2026
Viewed by 469
Abstract
Dry rooms used in battery and semiconductor research facilities require ultra-low dew-point environments, which demand significant thermal energy for desiccant rotor regeneration. In steam-regenerated systems, condensate discharged through steam traps partially evaporates due to pressure reduction, generating flash steam that is typically released [...] Read more.
Dry rooms used in battery and semiconductor research facilities require ultra-low dew-point environments, which demand significant thermal energy for desiccant rotor regeneration. In steam-regenerated systems, condensate discharged through steam traps partially evaporates due to pressure reduction, generating flash steam that is typically released into the atmosphere, resulting in substantial energy losses. This study investigates the generation and recovery potential of flash steam in dry room HVAC systems. Field measurements were conducted for 18 steam-regenerated desiccant air handling units installed in a medium-scale research facility (total floor area: 43,000 m2) in southern Gyeonggi Province, Korea. Boiler operation data—including feedwater flow rate, pressure, and operating time—were analyzed over a six-month period from March to August 2025. The results showed that the average flash steam generation rate was approximately 1.16 ton/h, corresponding to 8.56% of the average feedwater flow rate. Two recovery methods were evaluated: a steam jet thermocompressor (SJT) and an exhaust vapor condenser (EVC). The analysis revealed that the EVC system provides a more practical solution for medium-scale dry rooms because it does not require high-pressure primary steam. By recovering flash steam using three EVC units, an average heat recovery of 724 kW was achieved. The recovered heat can produce 86 °C hot water, which can be utilized as a driving heat source for an absorption chiller, generating approximately 507 kW of cooling capacity. This configuration partially offsets the cooling load of existing centrifugal chillers, thereby reducing electrical energy consumption. In addition, the proposed system eliminates atmospheric discharge of flash steam, mitigating the visible white plume phenomenon commonly observed in industrial facilities. The results demonstrate the technical feasibility of integrating flash steam recovery with absorption cooling to enhance energy efficiency in medium-scale dry room HVAC systems. Full article
(This article belongs to the Section B: Energy and Environment)
Show Figures

Figure 1

25 pages, 11601 KB  
Article
Experimental Analysis of Energy Savings in a Combined Rotary Desiccant Dehumidifier with a Purge Section
by Jeongsu Yang and YoungIl Kim
Sustainability 2025, 17(9), 4126; https://doi.org/10.3390/su17094126 - 2 May 2025
Cited by 2 | Viewed by 4292
Abstract
This study focuses on improving the performance of desiccant dehumidifiers using desiccant rotors, which are widely utilized in various industries, such as manufacturing, food, and construction, to enhance product quality and production efficiency. The combined desiccant dehumidifier can reduce energy consumption compared to [...] Read more.
This study focuses on improving the performance of desiccant dehumidifiers using desiccant rotors, which are widely utilized in various industries, such as manufacturing, food, and construction, to enhance product quality and production efficiency. The combined desiccant dehumidifier can reduce energy consumption compared to traditional standard or purge dehumidifiers. The system operates in normal mode during seasons with high outdoor humidity and in purge mode during seasons with low outdoor humidity. By utilizing dampers, the air passing through the dry desiccant rotor can either be directly discharged indoors or supplied to the regeneration section, allowing the system to operate in two modes within a single unit. The first part of the study involved comparing the performance of the equipment through experiments. The second part compared the results from the dehumidifier rotor performance simulation program to check for deviations and validate its effectiveness. In the first experiment, the energy consumption of the standard desiccant dehumidifier in normal mode was compared with that of the combined desiccant dehumidifier in normal mode. In the second experiment, the energy consumption of the standard desiccant dehumidifier in normal mode was compared with that of the combined desiccant dehumidifier in purge mode. The airflow, temperature, and humidity values used in each experiment were analyzed using a dehumidification performance simulation program, and the deviation was found to be within 10%. Therefore, the performance analysis via simulation was considered valid. The dehumidification performance of the combined desiccant dehumidifier was found to be 5% more efficient than the traditional standard desiccant dehumidifier and 9.5% more efficient than the purge dehumidifier. Furthermore, energy consumption simulations were conducted for representative regions in Korea. The results showed energy reductions of 65% in Seoul, 65% in Daejeon, and 67% in Busan. The findings of this study suggest that energy savings can be achieved by appropriately adjusting the operation mode between normal and purge modes based on outdoor conditions. Full article
(This article belongs to the Topic Sustainable Energy Systems)
Show Figures

Figure 1

17 pages, 3460 KB  
Article
A Liquid Desiccant Enhanced Two Stage Evaporative Cooling System—Development and Performance Evaluation of a Test Rig
by M. Mujahid Rafique, Shafiqur Rehman, Luai M. Alhems and Muhammad Ali Shakir
Energies 2018, 11(1), 72; https://doi.org/10.3390/en11010072 - 29 Dec 2017
Cited by 13 | Viewed by 8031
Abstract
Desiccant technology is found to be a good alternative to conventional cooling systems. It can provide better thermal comfort under hot and humid climatic conditions. The major component of a liquid desiccant cooling system is the desiccant dehumidifier which controls the latent cooling [...] Read more.
Desiccant technology is found to be a good alternative to conventional cooling systems. It can provide better thermal comfort under hot and humid climatic conditions. The major component of a liquid desiccant cooling system is the desiccant dehumidifier which controls the latent cooling load. In this paper, a newly developed liquid desiccant enhanced evaporative cooling system has been tested experimentally. The effects of ambient conditions and other parameters on the performance of the system are investigated. The system performance curves which help to determine the air outlet conditions and coefficient of performance (COP) of the system are drawn for a wide range of ambient air humidity ratios (0.010–0.026 kg/kg), ambient air temperature (25–40 °C), process air flow rate (1.5–8.0 kg/m2·s), regeneration air flow rate (1.5–4.5 kg/m2·s), and regeneration temperature (55–85 °C). The results showed that better supply air conditions are achieved for hot and humid climatic conditions with effectiveness of the system largely dependent on process and regeneration air flow rates, regeneration temperature, and humidity ratio of process air. The dehumidification performance is increased by 62% for a change of ambient air humidity ratio from 0.01 to 0.025 kg/kg. The thermal coefficient of performance improved by 50% for the above variation in humidity ratio. This shows that such thermally activated systems are feasible options for hot and humid climatic conditions as indicated by better performance under these conditions. Full article
Show Figures

Graphical abstract

15 pages, 1879 KB  
Article
Parametric Analysis of a Rotary Type Liquid Desiccant Air Conditioning System
by M. Mujahid Rafique, Shafiqur Rehman, Luai M. Alhems and Aref Lashin
Energies 2016, 9(4), 305; https://doi.org/10.3390/en9040305 - 21 Apr 2016
Cited by 12 | Viewed by 7271
Abstract
Now days, air conditioning systems are a must for almost every commercial and residential building to achieve comfortable indoor conditions. The increasing energy demand, and increasing oil prices and pollution levels raise the need for alternative air conditioning systems which can efficiently utilize [...] Read more.
Now days, air conditioning systems are a must for almost every commercial and residential building to achieve comfortable indoor conditions. The increasing energy demand, and increasing oil prices and pollution levels raise the need for alternative air conditioning systems which can efficiently utilize renewable energy resources. The liquid desiccant-based air conditioning method is pollution free and thermal energy-based cooling techniques can use low grade thermal energy resources like solar energy, waste heat, etc. These systems have an additional advantage of cleaning bacteria and fungi from the air. In this paper, a newly proposed rotary liquid desiccant air conditioning system has been investigated theoretically. Most direct contact liquid desiccant cooling systems have the problem of desiccant carryover which can be eliminated using the proposed system. The effects of various key parameters and climatic conditions on the performance of the system have been evaluated. The results showed that if the key parameters of the system are controlled effectively, the proposed cooling system has the ability to achieve the desired supply air conditions. The system can achieve high coefficient of performance (COP) under different conditions. The dehumidifier has a sensible heat ratio (SHR) in the range of 0.3–0.6 for different design, climatic, and operating conditions. The system can remove latent load efficiently in applications which require good humidity control. Full article
Show Figures

Graphical abstract

Back to TopTop