Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (11)

Search Parameters:
Keywords = presbyopia-correcting intraocular lens

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 865 KiB  
Article
Comparative Outcomes of the Next-Generation Extended Depth-of-Focus Intraocular Lens and Enhanced Monofocal Intraocular Lens in Cataract Surgery
by Do Young Kim, Ella Seo Yeon Park, Hyunjin Park, Bo Yi Kim, Ikhyun Jun, Kyoung Yul Seo, Ahmed Elsheikh and Tae-im Kim
J. Clin. Med. 2025, 14(14), 4967; https://doi.org/10.3390/jcm14144967 - 14 Jul 2025
Viewed by 595
Abstract
Background/Objectives: A new, purely refractive extended depth-of-focus (EDOF) intraocular lens (IOL) was designed with a continuous change in power to bridge the gap between monofocal and multifocal IOLs. This study aimed to evaluate the real-world clinical outcomes of the new EDOF IOL compared [...] Read more.
Background/Objectives: A new, purely refractive extended depth-of-focus (EDOF) intraocular lens (IOL) was designed with a continuous change in power to bridge the gap between monofocal and multifocal IOLs. This study aimed to evaluate the real-world clinical outcomes of the new EDOF IOL compared with those of the enhanced monofocal IOL. Methods: A retrospective analysis was conducted on 100 eyes from 50 patients undergoing bilateral cataract surgery with either the PureSee™ EDOF (ZEN00V) or Eyhance™ (ICB00) monofocal IOL at a single institution. Visual acuity, defocus curves, contrast sensitivity, and patient-reported outcomes were evaluated three months postoperatively. Results: The ZEN00V group demonstrated superior uncorrected intermediate (0.11 ± 0.08 vs. 0.17 ± 0.11 logMAR, p = 0.006) and near visual acuity (0.25 ± 0.08 vs. 0.31 ± 0.13 logMAR, p = 0.023) compared to the ICB00 group, with comparable distance visual acuity. Both groups exhibited comparable defocus curves and contrast sensitivity. While photic phenomena were more frequent in the ZEN00V group, spectacle dependence was significantly lower for near vision (36% vs. 80%, p = 0.002) and comparable for intermediate and far vision. Conclusions: The PureSee™ EDOF IOL demonstrated enhanced intermediate and near vision with minimal compromise to distance vision while maintaining high contrast sensitivity. It also offered significant spectacle independence and patient satisfaction, making it a promising option for presbyopia correction. Full article
(This article belongs to the Section Ophthalmology)
Show Figures

Figure 1

11 pages, 1021 KiB  
Article
Clinical Outcomes of Combined Phacoemulsification, Extended Depth-of-Focus Intraocular Lens Implantation, and Epiretinal Membrane Peeling Surgery
by Ho-Seok Chung, Dabin Lee and Jin-Hyoung Park
J. Clin. Med. 2025, 14(7), 2423; https://doi.org/10.3390/jcm14072423 - 2 Apr 2025
Viewed by 663
Abstract
Background/Objectives: To evaluate the clinical efficacy and safety of combined phacoemulsification, extended depth-of-focus (EDOF) intraocular lens (IOL) implantation, and epiretinal membrane (ERM) peeling during vitrectomy surgery for treating patients with ERM, cataracts, and presbyopia. Methods: Patients with preexisting low-grade ERM who [...] Read more.
Background/Objectives: To evaluate the clinical efficacy and safety of combined phacoemulsification, extended depth-of-focus (EDOF) intraocular lens (IOL) implantation, and epiretinal membrane (ERM) peeling during vitrectomy surgery for treating patients with ERM, cataracts, and presbyopia. Methods: Patients with preexisting low-grade ERM who underwent cataract surgery with the implantation of an EDOF IOL were included. Corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), autorefraction and keratometry, manifest refraction, and central foveal thickness (CFT) were measured before surgery and at postoperative months 3 and 6. A monocular defocus curve was measured 6 months postoperatively. Furthermore, patients were instructed to report symptoms of photic phenomena at each visit. Results: In total, 16 eyes of 16 patients (median age, 59.5 years) were included in this study. Compared with those at baseline, the CDVA, UDVA, UIVA, UNVA, and CFT significantly improved at 3 and 6 months postoperatively. The defocus curve revealed that a visual acuity of 0.12 logarithm of the minimal angle of resolution or better was maintained from +0.5 to –1.5 diopters. No patients reported visual disturbances suggestive of photic phenomena, such as glare or halo. Conclusions: EDOF IOL implantation had excellent outcomes, including improved distance and intermediate visual acuity, functional near visual acuity, and absence of visual symptoms in patients who received phacovitrectomy to treat low-grade ERM. Full article
Show Figures

Figure 1

12 pages, 1913 KiB  
Article
Optical Bench Evaluation of a Novel, Hydrophobic, Acrylic, One-Piece, Polyfocal Intraocular Lens with a “Zig-Zag” L-Loop Haptic Design
by Andreas F. Borkenstein, Eva-Maria Borkenstein, Pooria Omidi and Achim Langenbucher
Vision 2024, 8(4), 66; https://doi.org/10.3390/vision8040066 - 14 Nov 2024
Cited by 1 | Viewed by 1280
Abstract
Purpose: The number of presbyopia-correcting (premium) intraocular lenses (IOLs) is growing steadily as the desire for spectacle independence after cataract surgery increases. The aim of this laboratory study was to evaluate a newly launched hydrophobic, acrylic, polyfocal, refractive intraocular lens with a new [...] Read more.
Purpose: The number of presbyopia-correcting (premium) intraocular lenses (IOLs) is growing steadily as the desire for spectacle independence after cataract surgery increases. The aim of this laboratory study was to evaluate a newly launched hydrophobic, acrylic, polyfocal, refractive intraocular lens with a new optical design and geometry. This polyfocal IOL has three different zones (within the optic) with radially asymmetric design. Methods: We performed optical bench tests to calculate the optical characteristics of the sample. The optical performance and quality of IOLs based on ISO 11979-2 and 11979-9 requirements were analyzed with the NIMO TR0815 (Lambda-X). In addition, optical quality metrics were evaluated with the IOLA MFD device (Rotlex). Sphere, Add, modulation transfer function (MTF), the energy distribution between the modes and the MTF along the whole range from far to near were analyzed. Results: The power histogram showed that the tested IOL has the characteristics of a polyfocal IOL with a wide range of optical power between 20.5 and 24.5 diopters. Two distinct peaks were observed, indicating bifocal functionality. In the radial and axial power surface map, all three zones, stated by the company, could be detected. Larger apertures lead to a significant increase in MTF at the far peak, indicating better visual acuity for distant objects under low-light conditions. It was observed that in small aperture sizes, intermediate vision seems to be dominant. The energy distribution remained almost constant with increasing aperture size. Conclusions: This laboratory study was able to confirm the properties of the polyfocal lens stated by the company. Three optical zones could be identified. However, further optical bench tests should be performed to evaluate the new lens under tilted and decentered conditions. Clinical studies have to confirm that the presbyopia-correcting, polyfocal lens can achieve good clinical results with high patient satisfaction without disturbing side effects. Full article
Show Figures

Figure 1

10 pages, 2476 KiB  
Article
Comparison of a Presbyopia-Correcting Supplementary Intraocular Lens Combination and a Capsular-Bag Lens: An In Vitro Study
by Ramin Khoramnia, Isabella Diana Baur, Weijia Yan, Grzegorz Łabuz and Gerd Uwe Auffarth
Diagnostics 2023, 13(8), 1482; https://doi.org/10.3390/diagnostics13081482 - 20 Apr 2023
Cited by 5 | Viewed by 2250
Abstract
We evaluated the optical quality of two approaches to trifocality: polypseudophakia versus monopseudophakia. The combination (polypseudophakia) of a monofocal Basis Z B1AWY0 and AddOn Trifocal A4DW0M intraocular lens (IOL) was compared to using one Basis Z Trifocal B1EWYN IOL, all from 1stQ GmbH. [...] Read more.
We evaluated the optical quality of two approaches to trifocality: polypseudophakia versus monopseudophakia. The combination (polypseudophakia) of a monofocal Basis Z B1AWY0 and AddOn Trifocal A4DW0M intraocular lens (IOL) was compared to using one Basis Z Trifocal B1EWYN IOL, all from 1stQ GmbH. In both approaches, we measured modulation transfer function (MTF) and Strehl Ratio (SR) values at 3.0 and 4.5 mm pupil sizes. We determined the through-focus (TF) MTF at 25, 50 and 100 lp/mm for the 3 mm aperture. United States Air Force (USAF) target images were recorded. MTF measurement of the trifocal lens and the combined monofocal and trifocal AddOn IOL showed good performance at the far and near focus for the 3 mm aperture. For the 4.5 mm aperture the MTF improved for the far focus but decreased for the intermediate and near focus. TF MTF showed better contrast at the far focus for the polypseudophakic setup but at the expense of the efficiency at the near focus. However, the USAF chart images revealed only minimal differences between both approaches. The optical quality of the polypseudophakic approach was not affected by the presence of two IOLs instead of one and proved to be comparable with the performance of one capsular-bag-fixated trifocal IOL. Differences between the single vs. two-lens approach seen in the TF MTF analysis could be attributed to the optical design that varied between the trifocal models. Full article
(This article belongs to the Section Pathology and Molecular Diagnostics)
Show Figures

Figure 1

11 pages, 2149 KiB  
Article
Comparison of Five Presbyopia-Correcting Intraocular Lenses: Optical-Bench Assessment with Visual-Quality Simulation
by Grzegorz Łabuz, Weijia Yan, Isabella D. Baur, Ramin Khoramnia and Gerd U. Auffarth
J. Clin. Med. 2023, 12(7), 2523; https://doi.org/10.3390/jcm12072523 - 27 Mar 2023
Cited by 19 | Viewed by 4683
Abstract
Presbyopia correction through implantation of a trifocal intraocular lens (IOL) is a modality offered to both cataract and refractive-lens exchange patients. To maximize postoperative satisfaction, IOL selection needs to be made based on patients’ requirements aligned with the available technology. Five Trifocal IOLs [...] Read more.
Presbyopia correction through implantation of a trifocal intraocular lens (IOL) is a modality offered to both cataract and refractive-lens exchange patients. To maximize postoperative satisfaction, IOL selection needs to be made based on patients’ requirements aligned with the available technology. Five Trifocal IOLs were assessed in this study, and their differentiating features were identified: Triumf POD L GF, AT Lisa Tri, Tecnis Synergy, AcrySof IQ PanOptix, and Acriva Trinova Pro C. The optical quality was assessed using the modulation-transfer-function principle. Simulated defocus curves were derived from a non-linear formula. Far-focus simulated visual acuity (simVA) was 0.03 logMAR or better for all the studied IOLs, showing minimal differences. However, each IOL’s intermediate focus position differed across a range from 61 cm to 80 cm; and for the near focus, it was 36 cm to 44 cm. Triumf demonstrated improved intermediate point at the expense of the near focus resulting in a lower predicted near VA. PanOptix exhibited the shortest range of vision without a clear distinction between intermediate and near-point. The remaining lenses presented three foci of comparable optical quality and, thus, simVA performance. Each model, however, revealed a different aperture-change response. Trinova function improved at intermediate but was worse at near for larger pupils. The opposite was observed for AT Lisa. Synergy’s optical quality change was predominantly associated with lower pupil diameter. In conclusion, the trifocal IOLs can be differentiated according to their secondary-foci position, light-energy distribution, and pupil-size-related behavior. The observed differences may translate directly into a clinical effect showing that the trifocal IOLs vary in their ability to deliver optimal vision at different distances, with some providing improved intermediate while others favor reading distance. The knowledge gained through this objective testing can support IOL selection, postoperative patient counselling and increase the chance of spectacle independence after surgery. Full article
(This article belongs to the Special Issue Selected Papers from “PRESBYOPIA 2022”)
Show Figures

Figure 1

9 pages, 4320 KiB  
Article
Visualization of Ray Propagation through Extended Depth-of-Focus Intraocular Lenses
by Isabella D. Baur, Gerd U. Auffarth, Weijia Yan, Grzegorz Łabuz and Ramin Khoramnia
Diagnostics 2022, 12(11), 2667; https://doi.org/10.3390/diagnostics12112667 - 2 Nov 2022
Cited by 12 | Viewed by 4103
Abstract
Extended depth-of-focus (EDoF) presbyopia-correcting intraocular lens (IOL) models differ in their optical design and performance. In the laboratory, we compared the ray propagation and light intensity profiles of four IOLs: the non-diffractive AcrySof IQ Vivity (Alcon Inc., Fort Worth, TX, USA) and two [...] Read more.
Extended depth-of-focus (EDoF) presbyopia-correcting intraocular lens (IOL) models differ in their optical design and performance. In the laboratory, we compared the ray propagation and light intensity profiles of four IOLs: the non-diffractive AcrySof IQ Vivity (Alcon Inc., Fort Worth, TX, USA) and two diffractive models, Symfony ZXR00 (Johnson & Johnson Vision, Jacksonville, FL, USA) and AT Lara 829 MP (Carl Zeiss Meditec, Berlin, Germany). A fourth lens, the monofocal AcrySof IQ SN60WF (Alcon Inc.) acted as the control. We projected a 520 nm laser light through each submerged lens in a bath of fluorescein solution. A camera mounted on a microscope captured the light that emerged from the IOL. We recorded the IOLs’ point spread function (PSF) to determine the presence of unwanted visual effects. The ray propagation visualization and light intensity profile of the monofocal control showed one distinct focus, while the AcrySof IQ Vivity demonstrated an extended focus area. We observed two distinct foci with each diffractive IOL. We found a lower level of light spread beyond the PSF center for the AcrySof IQ Vivity compared to the diffractive IOLs. In conclusion, we could confirm the extended range of focus for all the EDoF IOL models. However, the non-diffractive AcrySof IQ Vivity appears to have a smoother transition from a far to an intermediate range. We discuss whether, in clinical use, the higher level of spurious light we found in the diffractive designs may translate into increased dysphotopsia. Full article
(This article belongs to the Special Issue Refining Diagnosis in Ophthalmology through Laboratory Research)
Show Figures

Figure 1

12 pages, 2854 KiB  
Article
Simultaneous Presbyopia and Astigmatism Correction with a Novel Trifocal Toric Intraocular Lens—A One-Year Follow-Up
by Ladislav Viktor Nováček, Marie Němcová, Kristýna Sičová, Kateřina Tyx, Pavel Rozsíval, Jan Němčanský and Pavel Studený
J. Clin. Med. 2022, 11(14), 4194; https://doi.org/10.3390/jcm11144194 - 19 Jul 2022
Cited by 1 | Viewed by 2402
Abstract
The current investigation evaluates the efficiency of the trifocal toric Liberty 677MTY intraocular lens (IOL) in correcting preoperative corneal astigmatism in cataract patients demanding spectacle independence. The retrospective evaluation included 28 eyes of 15 patients with preoperative corneal astigmatism of at least 1.0 [...] Read more.
The current investigation evaluates the efficiency of the trifocal toric Liberty 677MTY intraocular lens (IOL) in correcting preoperative corneal astigmatism in cataract patients demanding spectacle independence. The retrospective evaluation included 28 eyes of 15 patients with preoperative corneal astigmatism of at least 1.0 Dioptre (D). All patients were followed up for one year postoperatively. Residual refractive errors and visual acuities at multiple distances were measured. Binocular visual acuity and contrast sensitivity defocus curves were plotted. Visual functions and patient satisfaction were assessed. The efficiency of astigmatism correction was determined using the vector analysis method. The mean spherical equivalent refraction (SEQ) improved from 2.72 ± 1.62 D to 0.10 ± 0.48 D. The cylindric refraction decreased from 1.18 ± 0.45 D to 0.16 ± 0.31 D. Vector analysis proved efficient astigmatism correction with a centroid of 0.10 ± 0.34 D at 161°. Ninety-two percent of eyes resulted within 0.5 D from the target refraction. Visual acuities were 0.1 logMAR or better from +1.0 to −3.5 D defocus values. Visual tasks could be performed without major difficulties. Our patients were highly satisfied. Refractive and visual outcomes with the investigated presbyopia-correcting toric IOL are predictable and the lens provides excellent trifocal vision. Full article
(This article belongs to the Special Issue Presbyopia: Current Management and Future Trends)
Show Figures

Figure 1

11 pages, 998 KiB  
Article
Far and Near Contrast Sensitivity and Quality of Vision with Six Presbyopia Correcting Intraocular Lenses
by Miguel Á. Gil, Consuelo Varón, Genis Cardona and José A. Buil
J. Clin. Med. 2022, 11(14), 4150; https://doi.org/10.3390/jcm11144150 - 17 Jul 2022
Cited by 11 | Viewed by 2798
Abstract
The objective of this prospective, randomized, double-masked study was to compare the contrast sensitivity and quality of vision of patients bilaterally implanted with the following six different presbyopia correcting intraocular lenses (IOLs): SV25T0 (n = 19), ATLISA 809M (n = 18), [...] Read more.
The objective of this prospective, randomized, double-masked study was to compare the contrast sensitivity and quality of vision of patients bilaterally implanted with the following six different presbyopia correcting intraocular lenses (IOLs): SV25T0 (n = 19), ATLISA 809M (n = 18), ATLISA TRI 839MP (n = 19), ZKB00 (n = 20), ZLB00 (n = 20) and Symfony ZXR00 (n = 20). For comparison purposes, 36 patients were implanted with a monofocal lens (ZA9003). Contrast sensitivity was assessed binocularly at distance under photopic, mesopic and mesopic plus glare conditions, and at near under photopic conditions. Quality of vision was explored in terms of photic phenomena and spectacle independence. Overall, the monofocal lens offered better contrast sensitivity, under all illumination conditions, and less occurrence and intensity of photic phenomena. Amongst the multifocal IOL (MIOL) designs, the extended depth of focus Symfony ZXR00 provided better contrast sensitivity than the other MIOLs, particularly at intermediate and high spatial frequencies. Up to 40% and 50% of patients implanted with MIOLs reported glare and halos, respectively. The SV25T0 resulted in less occurrence and intensity of halos. The evaluation of photic phenomena and contrast sensitivity under different illumination conditions may reflect real-life, visually challenging situations, and thus provide insightful information to assist ophthalmic surgeons when selecting the best intraocular lens for their patients. Full article
(This article belongs to the Special Issue Cataract Surgery and Postoperative Care – Part II)
Show Figures

Figure 1

10 pages, 1600 KiB  
Article
In Vitro Chromatic Performance of Three Presbyopia-Correcting Intraocular Lenses with Different Optical Designs
by Diego Montagud-Martínez, Vicente Ferrando, Anabel Martínez-Espert, Salvador Garcia-Delpech, Juan A. Monsoriu and Walter D. Furlan
J. Clin. Med. 2022, 11(5), 1212; https://doi.org/10.3390/jcm11051212 - 24 Feb 2022
Cited by 14 | Viewed by 2816
Abstract
Most of the new premium models of intraocular lenses for presbyopia correction use diffractive optics in their optical design. The presence of multiple foci and the difference of the diffractive efficiency for different wavelengths have a great impact in the lens optical performance. [...] Read more.
Most of the new premium models of intraocular lenses for presbyopia correction use diffractive optics in their optical design. The presence of multiple foci and the difference of the diffractive efficiency for different wavelengths have a great impact in the lens optical performance. In this context, there is a limited information available for clinicians to understand the optical principles that differentiate each design and their potential influence on clinical outcomes. Optical bench studies with polychromatic light are necessary to solve this limitation. In this work, a custom made optical bench was employed to assess with polychromatic light the through the focus optical quality of three different IOL designs: trifocal, EDOF effect; and enhanced monofocal. By using different and complimentary approaches: images of the USAF test, axial PSFs and TF-MTFs, each design revealed its intrinsic features, which were not previously reported for these IOLs models in a comparative way. It was found that the chromatic aberration plays a very important role in the performance of each IOL. Our results could help clinicians to understand the optical principle of each lens and also provide useful information for choosing the lens that best suits the needs of the individual patient. Full article
(This article belongs to the Special Issue Hot Topics in PRESBYOPIA 2021)
Show Figures

Graphical abstract

13 pages, 3722 KiB  
Article
An Artificial Lens Capsule with a Lens Radial Stretching System Mimicking Dynamic Eye Focusing
by Huidong Wei, James S. Wolffsohn, Otavio Gomes de Oliveira and Leon N. Davies
Polymers 2021, 13(20), 3552; https://doi.org/10.3390/polym13203552 - 15 Oct 2021
Cited by 7 | Viewed by 5159
Abstract
Presbyopia is a common eye disorder among aged people which is attributed to the loss of accommodation of the crystalline lens due to the increasing stiffness. One of the potential techniques to correct presbyopia involves removing the lens substance inside the capsule and [...] Read more.
Presbyopia is a common eye disorder among aged people which is attributed to the loss of accommodation of the crystalline lens due to the increasing stiffness. One of the potential techniques to correct presbyopia involves removing the lens substance inside the capsule and replacing it with an artificial lens. The development of such devices, e.g., accommodating intraocular lenses (AIOLs), relies on the understanding of the biomechanical behaviour of the lens capsule and the essential design verification ex vivo. To mimic the eye’s dynamic focusing ability (accommodation), an artificial lens capsule (ALC), from silicone rubber accompanied by a lens radial stretching system (LRSS) was developed. The ALC was manufactured to offer a dimension and deforming behaviour replicating the human lens capsule. The LRSS was calibrated to provide a radial stretch simulating the change of diameter of capsules during accommodating process. The biomechanical function of the ALC was addressed by studying its evolution behaviour and reaction force under multiaxial stretch from the LRSS. The study highlighted the convenience of this application by performing preliminary tests on prototypes of ophthalmic devices (e.g., AIOLs) to restore accommodation. Full article
(This article belongs to the Special Issue Bioactive Polymer Composites and Their Clinical Applications)
Show Figures

Graphical abstract

15 pages, 1998 KiB  
Article
Comparison of Clinical Outcomes, Visual Quality and Visual Function of Two Presbyopia-Correcting Intraocular Lenses Made from the Same Material, but with Different Design and Optics
by Ladislav Viktor Nováček, Marie Němcová, Kateřina Tyx, Kristýna Lahodová, Leoš Rejmont, Pavel Rozsíval and Pavel Studený
J. Clin. Med. 2021, 10(15), 3268; https://doi.org/10.3390/jcm10153268 - 24 Jul 2021
Cited by 6 | Viewed by 3467
Abstract
This semi-prospective, parallel, comparative investigation evaluated the clinical outcomes and quality of vision (contrast sensitivity, visual function, dysphotopsia, spectacle use, overall satisfaction) after mono- or bilateral implantation of two presbyopia-correcting intraocular lenses (IOL)—the Liberty® 677MY or the AT LISA® tri 839M—in [...] Read more.
This semi-prospective, parallel, comparative investigation evaluated the clinical outcomes and quality of vision (contrast sensitivity, visual function, dysphotopsia, spectacle use, overall satisfaction) after mono- or bilateral implantation of two presbyopia-correcting intraocular lenses (IOL)—the Liberty® 677MY or the AT LISA® tri 839M—in 50 eyes of 25 cataract patients. Clinical outcomes were assessed 3 and 12 months postoperatively. Eighty-nine percent of eyes implanted with the Liberty IOL and 59% of eyes implanted with the AT LISA IOL achieved a refractive outcome ±0.5 diopters of the target (emmetropia). Refractive outcomes were stable with both lenses. The proportions of eyes with 20/20 uncorrected distance visual acuity (UDVA) and 20/20 uncorrected near visual acuity (UNVA) were higher in the Liberty group than in the AT LISA group (UDVA: 56% vs. 41%; UNVA: 83% vs. 66%). Optical quality assessment results were comparable for the two IOLs. Superior photopic contrast sensitivity was found with the Liberty lens. The rate of Nd:YAG capsulotomy at the 12-month follow-up was 16.7% in the Liberty group and 40.6% for the AT LISA IOL. Considering that both lenses are made from the same material, we propose that the noted differences in clinical outcomes may derive from differences in design and optical surface between the two IOLs. Full article
(This article belongs to the Special Issue Hot Topics in PRESBYOPIA 2021)
Show Figures

Figure 1

Back to TopTop