Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (15)

Search Parameters:
Keywords = microchamber array

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
13 pages, 6093 KB  
Article
Real-Time Fluorescence Imaging Platform for Screening Arbuscular Mycorrhizal Fungi by Hyphal Transport Kinetics
by Guangle Zhang, Lixue Yuan, Yongxin Zhang, Xiaohang Wang, Li Zhang, Xinyuan Zhang, Ruxue Chen, Zhuangzhuang Wang, Bo Yu and Yonghua Wang
Microbiol. Res. 2026, 17(5), 96; https://doi.org/10.3390/microbiolres17050096 - 19 May 2026
Viewed by 544
Abstract
Arbuscular mycorrhizal (AM) fungi form mutualistic symbioses with about 80% of land plants and play a key role in improving host inorganic phosphate (Pi), nitrogen, and water acquisition. Traditional AM fungi research relies on field trials, compartmented cultivation, and pot cultures—methods that are [...] Read more.
Arbuscular mycorrhizal (AM) fungi form mutualistic symbioses with about 80% of land plants and play a key role in improving host inorganic phosphate (Pi), nitrogen, and water acquisition. Traditional AM fungi research relies on field trials, compartmented cultivation, and pot cultures—methods that are time-consuming (taking months to years) and unable to monitor dynamic transport, thus limiting efficient strain screening. We developed a real-time fluorescence imaging platform integrating sterile symbiotic microchambers with photodiode array detection. This system enables the non-invasive, quantitative tracking of hyphal cytoplasmic streaming and transport kinetics at the plant–fungal interface. Distinct AM fungi strains exhibit significant differences in fluorescence kinetics—such as accumulation rate and peak intensity—providing measurable indicators of transport efficiency. Our method overcomes the temporal and technical limitations of conventional AM fungi screening approaches. By enabling simultaneous real-time monitoring, it shortens screening cycles and provides new insights for the (1) precise screening of AM fungi strains for efficient nutrient transport; (2) investigation of nutrient exchange mechanisms; (3) development of sustainable microbial inoculants. Full article
(This article belongs to the Topic New Challenges on Plant–Microbe Interactions)
Show Figures

Figure 1

15 pages, 4638 KB  
Article
A Chamber-Based Digital PCR Based on a Microfluidic Chip for the Absolute Quantification and Analysis of KRAS Mutation
by Jie Ren, Gangwei Xu, Hongna Liu, Nongyue He, Zhehao Zhao, Meiling Wang, Peipei Gu, Zhu Chen, Yan Deng, Dongping Wu and Song Li
Biosensors 2023, 13(8), 778; https://doi.org/10.3390/bios13080778 - 1 Aug 2023
Cited by 10 | Viewed by 5081
Abstract
The Kirsten rat sarcoma virus gene (KRAS) is the most common tumor in human cancer, and KRAS plays an important role in the growth of tumor cells. Normal KRAS inhibits tumor cell growth. When mutated, it will continuously stimulate cell growth, resulting in [...] Read more.
The Kirsten rat sarcoma virus gene (KRAS) is the most common tumor in human cancer, and KRAS plays an important role in the growth of tumor cells. Normal KRAS inhibits tumor cell growth. When mutated, it will continuously stimulate cell growth, resulting in tumor development. There are currently few drugs that target the KRAS gene. Here, we developed a microfluidic chip. The chip design uses parallel fluid channels combined with cylindrical chamber arrays to generate 20,000 cylindrical microchambers. The microfluidic chip designed by us can be used for the microsegmentation of KRAS gene samples. The thermal cycling required for the PCR stage is performed on a flat-panel instrument and detected using a four-color fluorescence system. “Glass-PDMS-glass” sandwich structure effectively reduces reagent volatilization; in addition, a valve is installed at the sample inlet and outlet on the upper layer of the chip to facilitate automatic control. The liquid separation performance of the chip was verified by an automated platform. Finally, using the constructed KRAS gene mutation detection system, it is verified that the chip has good application potential for digital polymerase chain reaction (dPCR). The experimental results show that the chip has a stable performance and can achieve a dynamic detection range of four orders of magnitude and a gene mutation detection of 0.2%. In addition, the four-color fluorescence detection system developed based on the chip can distinguish three different KRAS gene mutation types simultaneously on a single chip. Full article
(This article belongs to the Special Issue Biosensing for Point-of-Care Diagnostics)
Show Figures

Figure 1

12 pages, 2927 KB  
Article
Fabrication and Validation of a 3D Portable PEGDA Microfluidic Chip for Visual Colorimetric Detection of Captured Breast Cancer Cells
by Mingyi Guo, Yan Deng, Junqiu Huang, Yanping Huang, Jing Deng and Huachang Wu
Polymers 2023, 15(15), 3183; https://doi.org/10.3390/polym15153183 - 27 Jul 2023
Cited by 8 | Viewed by 3530
Abstract
To guide therapeutic strategies and to monitor the state changes in the disease, a low-cost, portable, and easily fabricated microfluidic-chip-integrated three-dimensional (3D) microchamber was designed for capturing and analyzing breast cancer cells. Optimally, a colorimetric sensor array was integrated into a microfluidic chip [...] Read more.
To guide therapeutic strategies and to monitor the state changes in the disease, a low-cost, portable, and easily fabricated microfluidic-chip-integrated three-dimensional (3D) microchamber was designed for capturing and analyzing breast cancer cells. Optimally, a colorimetric sensor array was integrated into a microfluidic chip to discriminate the metabolites of the cells. The ultraviolet polymerization characteristic of poly(ethylene glycol) diacrylate (PEGDA) hydrogel was utilized to rapidly fabricate a three-layer hydrogel microfluidic chip with the designed structure under noninvasive 365 nm laser irradiation. 2-Hydroxyethyl methacrylate (HEMA) was added to the prepolymer in order to increase the adhesive capacity of the microchip’s surface for capturing cells. 1-Vinyl-2-pyrrolidone (NVP) was designed to improve the toughness and reduce the swelling capacity of the hydrogel composite. A non-toxic 3D hydrogel microarray chip (60 mm × 20 mm × 3 mm) with low immunogenicity and high hydrophilicity was created to simulate the real physiological microenvironment of breast tissue. The crisscross channels were designed to ensure homogeneous seeding density. This hydrogel material displayed excellent biocompatibility and tunable physical properties compared with traditional microfluidic chip materials and can be directly processed to obtain the most desirable microstructure. The feasibility of using a PEGDA hydrogel microfluidic chip for the real-time online detection of breast cancer cells’ metabolism was confirmed using a specifically designed colorimetric sensor array with 16 kinds of porphyrin, porphyrin derivatives, and indicator dyes. The results of the principal component analysis (PCA), the hierarchical cluster analysis (HCA), and the linear discriminant analysis (LDA) suggest that the metabolic liquids of different breast cells can be easily distinguished with the developed PEGDA hydrogel microfluidic chip. The PEGDA hydrogel microfluidic chip has potential practicable applicability in distinguishing normal and cancerous breast cells. Full article
(This article belongs to the Special Issue Biopolymers for Drug Delivery and Tissue Engineering)
Show Figures

Figure 1

10 pages, 3579 KB  
Article
Particle Size-Dependent Component Separation Using Serially Arrayed Micro-Chambers
by Mitsuhiro Horade, Ryuusei Okumura, Tasuku Yamawaki, Masahito Yashima, Shuichi Murakami and Tsunemasa Saiki
Micromachines 2023, 14(5), 919; https://doi.org/10.3390/mi14050919 - 24 Apr 2023
Cited by 3 | Viewed by 2212
Abstract
The purpose of this research was to enable component separation based on simple control of the flow rate. We investigated a method that eliminated the need for a centrifuge and enabled easy component separation on the spot without using a battery. Specifically, we [...] Read more.
The purpose of this research was to enable component separation based on simple control of the flow rate. We investigated a method that eliminated the need for a centrifuge and enabled easy component separation on the spot without using a battery. Specifically, we adopted an approach that uses microfluidic devices, which are inexpensive and highly portable, and devised the channel within the fluidic device. The proposed design was a simple series of connection chambers of the same shape, connected via interconnecting channels. In this study, polystyrene particles with different sizes were used, and their behavior was evaluated by experimentally observing the flow in the chamber using a high-speed camera. It was found that the objects with larger particle diameters required more time to pass, whereas the objects with smaller particle diameters flowed in a short time; this implied that the particles with a smaller size could be extracted more rapidly from the outlet. By plotting the trajectories of the particles for each unit of time, the passing speed of the objects with large particle diameters was confirmed to be particularly low. It was also possible to trap the particles within the chamber if the flow rate was below a specific threshold. By applying this property to blood, for instance, we expected plasma components and red blood cells to be extracted first. Full article
Show Figures

Figure 1

19 pages, 2528 KB  
Article
Importance of Spatial Arrangement of Cardiomyocyte Network for Precise and Stable On-Chip Predictive Cardiotoxicity Measurement
by Kazufumi Sakamoto, Suguru Matsumoto, Nanami Abe, Mitsuru Sentoku and Kenji Yasuda
Micromachines 2023, 14(4), 854; https://doi.org/10.3390/mi14040854 - 14 Apr 2023
Cited by 3 | Viewed by 3018
Abstract
One of the advantages of human stem cell-derived cell-based preclinical screening is the reduction of the false negative/positive misjudgment of lead compounds for predicting their effectiveness and risks during the early stage of development. However, as the community effect of cells was neglected [...] Read more.
One of the advantages of human stem cell-derived cell-based preclinical screening is the reduction of the false negative/positive misjudgment of lead compounds for predicting their effectiveness and risks during the early stage of development. However, as the community effect of cells was neglected in the conventional single cell-based in vitro screening, the potential difference in results caused by the cell number and their spatial arrangement differences has not yet been sufficiently evaluated. Here, we have investigated the effect of the community size and spatial arrangement difference for cardiomyocyte network response against the proarrhythmic compounds from the viewpoint of in vitro cardiotoxicity. Using three different typical types of cell networks of cardiomyocytes, small cluster, large square sheet, and large closed-loop sheet were formed in shaped agarose microchambers fabricated on a multielectrode array chip simultaneously, and their responses were compared against the proarrhythmic compound, E-4031. The interspike intervals (ISIs) in large square sheets and closed-loop sheets were durable and maintained stable against E-4031 even at a high dose of 100 nM. In contrast, those in the small cluster, which fluctuated even without E-4031, acquired stable beating reflecting the antiarrhythmic efficacy of E-4031 from a 10 nM medium dose administration. The repolarization index, field potential duration (FPD), was prolonged in closed-loop sheets with 10 nM E-4031, even though small clusters and large sheets remained normal at this concentration. Moreover, FPDs of large sheets were the most durable against E-4031 among the three geometries of cardiomyocyte networks. The results showed the apparent spatial arrangement dependence on the stability of their interspike intervals, and FPD prolongation, indicating the importance of the geometry control of cell networks for representing the appropriate response of cardiomyocytes against the adequate amount of compounds for in vitro ion channel measurement. Full article
Show Figures

Figure 1

13 pages, 3175 KB  
Article
A Microfluidic Platform Revealing Interactions between Leukocytes and Cancer Cells on Topographic Micropatterns
by Xin Cui, Lelin Liu, Jiyu Li, Yi Liu, Ya Liu, Dinglong Hu, Ruolin Zhang, Siping Huang, Zhongning Jiang, Yuchao Wang, Yun Qu, Stella W. Pang and Raymond H. W. Lam
Biosensors 2022, 12(11), 963; https://doi.org/10.3390/bios12110963 - 2 Nov 2022
Cited by 10 | Viewed by 3848
Abstract
Immunoassay for detailed analysis of immune−cancer intercellular interactions can achieve more promising diagnosis and treatment strategies for cancers including nasopharyngeal cancer (NPC). In this study, we report a microfluidic live−cell immunoassay integrated with a microtopographic environment to meet the rising demand for monitoring [...] Read more.
Immunoassay for detailed analysis of immune−cancer intercellular interactions can achieve more promising diagnosis and treatment strategies for cancers including nasopharyngeal cancer (NPC). In this study, we report a microfluidic live−cell immunoassay integrated with a microtopographic environment to meet the rising demand for monitoring intercellular interactions in different tumor microenvironments. The developed assay allows: (1) coculture of immune cells and cancer cells on tunable (flat or micrograting) substrates, (2) simultaneous detection of different cytokines in a wide working range of 5–5000 pg/mL, and (3) investigation of migration behaviors of mono- and co-cultured cells on flat/grating platforms for revealing the topography-induced intercellular and cytokine responses. Cytokine monitoring was achieved on-chip by implementing a sensitive and selective microbead-based sandwich assay with an antibody on microbeads, target cytokines, and the matching fluorescent-conjugated detection antibody in an array of active peristaltic mixer-assisted cytokine detection microchambers. Moreover, this immunoassay requires a low sample volume down to 0.5 μL and short assay time (30 min) for on-chip cytokine quantifications. We validated the biocompatibility of the co-culture strategy between immune cells and NPC cells and compared the different immunological states of undifferentiated THP-1 monocytic cells or PMA-differentiated THP-1 macrophages co-culturing with NP460 and NPC43 on topographical and planar substrates, respectively. Hence, the integrated microfluidic platform provides an efficient, broad-range and precise on-chip cytokine detection approach, eliminates the manual sampling procedures and allows on-chip continuous cytokine monitoring without perturbing intercellular microenvironments on different topographical ECM substrates, which has the potential of providing clinical significance in early immune diagnosis, personalized immunotherapy, and precision medicine. Full article
Show Figures

Figure 1

11 pages, 2031 KB  
Article
Ultrasound-Triggerable Coatings for Foley Catheter Balloons for Local Release of Anti-Inflammatory Drugs during Bladder Neck Dilation
by Olga A. Sindeeva, Arkady S. Abdurashitov, Pavel I. Proshin, Alexey V. Kadrev, Oleg A. Kulikov, Boris M. Shaparov, Nikolay I. Sorokin, Valentin P. Ageev, Nikolay A. Pyataev, Aleksandr Kritskiy, Alexander Tishin, Armais A. Kamalov and Gleb B. Sukhorukov
Pharmaceutics 2022, 14(10), 2186; https://doi.org/10.3390/pharmaceutics14102186 - 13 Oct 2022
Cited by 5 | Viewed by 5297
Abstract
Bladder neck contracture (BNC) is a complication of the surgical treatment of benign and malignant prostate conditions and is associated with the partial or complete blockage of urination. Correction of this condition usually requires repeated surgical intervention, which does not guarantee recovery. Balloon [...] Read more.
Bladder neck contracture (BNC) is a complication of the surgical treatment of benign and malignant prostate conditions and is associated with the partial or complete blockage of urination. Correction of this condition usually requires repeated surgical intervention, which does not guarantee recovery. Balloon dilation is a minimally invasive alternative to the surgical dissection of tissues; however, it significantly reduces the patient’s quality of life. Additional local anti-inflammatory treatment may reduce the number of procedures requested and increase the attractiveness of this therapeutic strategy. Here, we report about an ultrathin biocompatible coating based on polylactic acid for Foley catheter balloons that can provide localized release of Prednol-L in the range of 56–99 µg in the BNC zone under conventional diagnostic ultrasound exposure. Note that the exposure of a transrectal probe with a conventional gray-scale ultrasound regimen with and without shear wave elastography (SWE) was comparably effective for Prednol-L release from the coating surface of a Foley catheter balloon. This strategy does not require additional manipulations by clinicians. The trigger for the drug release is the ultrasound exposure, which is applied for visualization of the balloon’s location during the dilation process. In vivo experiments demonstrated the absence of negative effects of the usage of a coated Foley catheter for balloon dilation of the bladder neck and urethra. Full article
Show Figures

Figure 1

13 pages, 2618 KB  
Article
“Smart” Polylactic Acid Films with Ceftriaxone Loaded Microchamber Arrays for Personalized Antibiotic Therapy
by Ekaterina A. Mordovina, Valentina O. Plastun, Arkady S. Abdurashitov, Pavel I. Proshin, Svetlana V. Raikova, Daniil N. Bratashov, Olga A. Inozemtseva, Irina Yu. Goryacheva, Gleb B. Sukhorukov and Olga A. Sindeeva
Pharmaceutics 2022, 14(1), 42; https://doi.org/10.3390/pharmaceutics14010042 - 26 Dec 2021
Cited by 12 | Viewed by 3796
Abstract
Bacterial infections are a severe medical problem, especially in traumatology, orthopedics, and surgery. The local use of antibiotics-elution materials has made it possible to increase the effectiveness of acute infections treatment. However, the infection prevention problem remains unresolved. Here, we demonstrate the fabrication [...] Read more.
Bacterial infections are a severe medical problem, especially in traumatology, orthopedics, and surgery. The local use of antibiotics-elution materials has made it possible to increase the effectiveness of acute infections treatment. However, the infection prevention problem remains unresolved. Here, we demonstrate the fabrication of polylactic acid (PLA) “smart” films with microchamber arrays. These microchambers contain ceftriaxone as a payload in concentrations ranging from 12 ± 1 μg/cm2 to 38 ± 8 μg/cm2, depending on the patterned film thickness formed by the different PLA concentrations in chloroform. In addition, the release profile of the antibiotic can be prolonged up to 72 h in saline. At the same time, on the surface of agar plates, the antibiotic release time increases up to 96 h, which has been confirmed by the growth suppression of the Staphylococcus aureus bacteria. The efficient loading and optimal release rate are obtained for patterned films formed by the 1.5 wt % PLA in chloroform. The films produced from 1.5 and 2 wt % PLA solutions (thickness—0.42 ± 0.12 and 0.68 ± 0.16 µm, respectively) show an accelerated ceftriaxone release upon the trigger of the therapeutic ultrasound, which impacted as an expansion of the bacterial growth inhibition zone around the samples. Combining prolonged drug elution with the on-demand release ability of large cargo amount opens up new approaches for personalized and custom-tunable antibacterial therapy. Full article
(This article belongs to the Section Drug Delivery and Controlled Release)
Show Figures

Figure 1

14 pages, 23082 KB  
Article
Patterned Drug-Eluting Coatings for Tracheal Stents Based on PLA, PLGA, and PCL for the Granulation Formation Reduction: In Vivo Studies
by Olga A. Sindeeva, Ekaterina S. Prikhozhdenko, Igor Schurov, Nikolay Sedykh, Sergey Goriainov, Arfenya Karamyan, Ekaterina A. Mordovina, Olga A. Inozemtseva, Valeriya Kudryavtseva, Leonid E. Shchesnyak, Rimma A. Abramovich, Sergey Mikhajlov and Gleb B. Sukhorukov
Pharmaceutics 2021, 13(9), 1437; https://doi.org/10.3390/pharmaceutics13091437 - 9 Sep 2021
Cited by 37 | Viewed by 7699
Abstract
Expandable metallic stent placement is often the only way to treat airway obstructions. Such treatment with an uncoated stent causes granulation proliferation and subsequent restenosis, resulting in the procedure’s adverse complications. Systemic administration of steroids drugs in high dosages slows down granulation tissue [...] Read more.
Expandable metallic stent placement is often the only way to treat airway obstructions. Such treatment with an uncoated stent causes granulation proliferation and subsequent restenosis, resulting in the procedure’s adverse complications. Systemic administration of steroids drugs in high dosages slows down granulation tissue overgrowth but leads to long-term side effects. Drug-eluting coatings have been used widely in cardiology for many years to suppress local granulation and reduce the organism’s systemic load. Still, so far, there are no available analogs for the trachea. Here, we demonstrate that PLA-, PCL- and PLGA-based films with arrays of microchambers to accommodate therapeutic substances can be used as a drug-eluting coating through securely fixing on the surface of an expandable nitinol stent. PCL and PLA were most resistant to mechanical damage associated with packing in delivery devices and making it possible to keep high-molecular-weight cargo. Low-molecular-weight methylprednisolone sodium succinate is poorly retained in PCL- and PLGA-based microchambers after immersion in deionized water (only 9.5% and 15.7% are left, respectively). In comparison, PLA-based microchambers retain 96.3% after the same procedure. In vivo studies on rabbits have shown that effective granulation tissue suppression is achieved when PLA and PLGA are used for coatings. PLGA-based microchamber coating almost completely degrades in 10 days in the trachea, while PLA-based microchamber films partially preserve their structure. The PCL-based film coating is most stable over time, which probably causes blocking the outflow of fluid from the tracheal mucosa and the aggravation of the inflammatory process against the background of low drug concentration. Combination and variability of polymers in the fabrication of films with microchambers to retain therapeutic compounds are suggested as a novel type of drug-eluting coating. Full article
(This article belongs to the Section Drug Delivery and Controlled Release)
Show Figures

Figure 1

13 pages, 2666 KB  
Review
Carbon Nanoparticles and Materials on Their Basis
by Alina A. Kokorina, Alexey V. Ermakov, Anna M. Abramova, Irina Yu. Goryacheva and Gleb B. Sukhorukov
Colloids Interfaces 2020, 4(4), 42; https://doi.org/10.3390/colloids4040042 - 25 Sep 2020
Cited by 17 | Viewed by 6675
Abstract
Carbon nanoparticles (CNPs) are novel nanostructures with luminescent properties. The development of CNPs involves the elaboration of various synthetic methods, structure characterization, and different applications. However, the problems associated with the CNP structure definition and properties homogeneity are not solved and barely described [...] Read more.
Carbon nanoparticles (CNPs) are novel nanostructures with luminescent properties. The development of CNPs involves the elaboration of various synthetic methods, structure characterization, and different applications. However, the problems associated with the CNP structure definition and properties homogeneity are not solved and barely described in depth. In this feature article, we demonstrate the approaches for the effective separation and purification of CNPs by size and size/charge ratio. We propose a promising way for the synthesis of the uniform-size structures by the application of calcium carbonate porous microparticles as reactors with defined size. Additionally, the application of the CNPs agglomerates for controllable release systems triggered by light and in-situ synthesis of fluorescent conductive carbonaceous films on the base of polyelectrolyte multilayers are under consideration. Full article
(This article belongs to the Special Issue Colloidal Systems: Formation and Applications of Nanomaterials)
Show Figures

Graphical abstract

20 pages, 8084 KB  
Article
A Microfluidic Diagnostic Device Capable of Autonomous Sample Mixing and Dispensing for the Simultaneous Genetic Detection of Multiple Plant Viruses
by Daigo Natsuhara, Keisuke Takishita, Kisuke Tanaka, Azusa Kage, Ryoji Suzuki, Yuko Mizukami, Norikuni Saka, Moeto Nagai and Takayuki Shibata
Micromachines 2020, 11(6), 540; https://doi.org/10.3390/mi11060540 - 26 May 2020
Cited by 29 | Viewed by 8555
Abstract
As an efficient approach to risk management in agriculture, the elimination of losses due to plant diseases and insect pests is one of the most important and urgent technological challenges for improving the crop yield. Therefore, we have developed a polydimethylsiloxane (PDMS)-based microfluidic [...] Read more.
As an efficient approach to risk management in agriculture, the elimination of losses due to plant diseases and insect pests is one of the most important and urgent technological challenges for improving the crop yield. Therefore, we have developed a polydimethylsiloxane (PDMS)-based microfluidic device for the multiplex genetic diagnosis of plant diseases and pests. It offers unique features, such as rapid detection, portability, simplicity, and the low-cost genetic diagnosis of a wide variety of plant viruses. In this study, to realize such a diagnostic device, we developed a method for the autonomous dispensing of fluid into a microchamber array, which was integrated with a set of three passive stop valves with different burst pressures (referred to as phaseguides) to facilitate precise fluid handling. Additionally, we estimated the mixing efficiencies of several types of passive mixers (referred to as chaotic mixers), which were integrated into a microchannel, through experimental and computational analyses. We first demonstrated the ability of the fabricated diagnostic devices to detect DNA-based plant viruses from an infected tomato crop based on the loop-mediated isothermal amplification (LAMP) method. Moreover, we demonstrated the simultaneous detection of RNA-based plant viruses, which can infect cucurbits, by using the reverse transcription LAMP (RT-LAMP) method. The multiplex RT-LAMP assays revealed that multiple RNA viruses extracted from diseased cucumber leaves were successfully detected within 60 min, without any cross-contamination between reaction microchambers, on our diagnostic device. Full article
Show Figures

Figure 1

6 pages, 3607 KB  
Article
1600 Parallel Microchamber Microfluidic Device for Fast Sample Array Preparation Using the Immiscibility of Two Liquids
by Chul Min Kim and Gyu Man Kim
Micromachines 2017, 8(3), 63; https://doi.org/10.3390/mi8030063 - 23 Feb 2017
Cited by 3 | Viewed by 6236
Abstract
We present a 1600 parallel microchamber microfluidic device for fast sample array preparation using the immiscibility of two liquids. The trapping efficiency and size of the arrayed sample in the microchambers of a parallel microfluidic device were analyzed at various flow rates. The [...] Read more.
We present a 1600 parallel microchamber microfluidic device for fast sample array preparation using the immiscibility of two liquids. The trapping efficiency and size of the arrayed sample in the microchambers of a parallel microfluidic device were analyzed at various flow rates. The trapping efficiency of the sample was also inspected according to the position of the microchamber. Samples were successfully arrayed using the device. The trapping efficiency of the sample was 98.69% at 1 mL/h. The trapping efficiency and diameter of the sample decreased as the flow rate increased. Trapping efficiencies also changed according to the position of the microchambers. As the distance of the microchambers from the inlet increased, the sample trapping efficiency decreased. This tendency occurred more clearly at higher flow rates. Full article
Show Figures

Graphical abstract

7 pages, 2322 KB  
Communication
High Throughput Studies of Cell Migration in 3D Microtissues Fabricated by a Droplet Microfluidic Chip
by Xiangchen Che, Jacob Nuhn, Ian Schneider and Long Que
Micromachines 2016, 7(5), 84; https://doi.org/10.3390/mi7050084 - 5 May 2016
Cited by 15 | Viewed by 6831
Abstract
Arrayed three-dimensional (3D) micro-sized tissues with encapsulated cells (microtissues) have been fabricated by a droplet microfluidic chip. The extracellular matrix (ECM) is a polymerized collagen network. One or multiple breast cancer cells were embedded within the microtissues, which were stored in arrayed microchambers [...] Read more.
Arrayed three-dimensional (3D) micro-sized tissues with encapsulated cells (microtissues) have been fabricated by a droplet microfluidic chip. The extracellular matrix (ECM) is a polymerized collagen network. One or multiple breast cancer cells were embedded within the microtissues, which were stored in arrayed microchambers on the same chip without ECM droplet shrinkage over 48 h. The migration trajectory of the cells was recorded by optical microscopy. The migration speed was calculated in the range of 3–6 µm/h. Interestingly, cells in devices filled with a continuous collagen network migrated faster than those where only droplets were arrayed in the chambers. This is likely due to differences in the length scales of the ECM network, as cells embedded in thin collagen slabs also migrate slower than those in thick collagen slabs. In addition to migration, this technical platform can be potentially used to study cancer cell-stromal cell interactions and ECM remodeling in 3D tumor-mimicking environments. Full article
(This article belongs to the Special Issue Micro/Nano Devices for Chemical Analysis)
Show Figures

Graphical abstract

14 pages, 3466 KB  
Article
Uniform Cell Distribution Achieved by Using Cell Deformation in a Micropillar Array
by Maho Kaminaga, Tadashi Ishida, Tetsuya Kadonosono, Shinae Kizaka-Kondoh and Toru Omata
Micromachines 2015, 6(4), 409-422; https://doi.org/10.3390/mi6040409 - 1 Apr 2015
Cited by 7 | Viewed by 9019
Abstract
The uniform dispersion of cells in a microchamber is important to reproduce results in cellular research. However, achieving this is difficult owing to the laminar flow caused by the small dimensions of such a chamber. In this study, we propose a technique to [...] Read more.
The uniform dispersion of cells in a microchamber is important to reproduce results in cellular research. However, achieving this is difficult owing to the laminar flow caused by the small dimensions of such a chamber. In this study, we propose a technique to achieve a uniform distribution of cells using a micropillar array inside a microchamber. The cells deform when they pass through a gap between the micropillars. The deformation causes a repetitive clog-and-release process of cells at the gaps between the micropillars. The micropillar array generates random flow inside the microchamber, resulting in the uniform distribution of the cells via cell accumulation. In the experiment, the distribution of cells in the microchamber with the micropillar array is uniform from end to end, whereas that in the microchamber without the micropillar array is centered. The deviation of the cell distribution from the ideally uniform distribution in the microchamber with the micropillar array is suppressed by 63% compared with that in the microchamber without the micropillar array. The doubling time of the cells passed through the micropillar array did not change relative to that of normal N87 cells. This technique will be helpful for reproducing results in cellular research at the micro scale or for those using microfluidic devices. Full article
Show Figures

Graphical abstract

38 pages, 2199 KB  
Review
On-Chip Cellomics Assay Enabling Algebraic and Geometric Understanding of Epigenetic Information in Cellular Networks of Living Systems. 1. Temporal Aspects of Epigenetic Information in Bacteria
by Kenji Yasuda
Sensors 2012, 12(6), 7169-7206; https://doi.org/10.3390/s120607169 - 30 May 2012
Viewed by 8404
Abstract
A series of studies aimed at developing methods and systems of analyzing epigenetic information in cells and in cell networks, as well as that of genetic information, was examined to expand our understanding of how living systems are determined. Because cells are minimum [...] Read more.
A series of studies aimed at developing methods and systems of analyzing epigenetic information in cells and in cell networks, as well as that of genetic information, was examined to expand our understanding of how living systems are determined. Because cells are minimum units reflecting epigenetic information, which is considered to map the history of a parallel-processing recurrent network of biochemical reactions, their behaviors cannot be explained by considering only conventional DNA information-processing events. The role of epigenetic information on cells, which complements their genetic information, was inferred by comparing predictions from genetic information with cell behaviour observed under conditions chosen to reveal adaptation processes, population effects and community effects. A system of analyzing epigenetic information was developed starting from the twin complementary viewpoints of cell regulation as an “algebraic” system (emphasis on temporal aspects) and as a “geometric” system (emphasis on spatial aspects). Exploiting the combination of latest microfabrication technology and measurement technologies, which we call on-chip cellomics assay, we can control and re-construct the environments and interaction of cells from “algebraic” and “geometric” viewpoints. In this review, temporal viewpoint of epigenetic information, a part of the series of single-cell-based “algebraic” and “geometric” studies of celluler systems in our research groups, are summerized and reported. The knowlege acquired from this study may lead to the use of cells that fully control practical applications like cell-based drug screening and the regeneration of organs. Full article
(This article belongs to the Special Issue Live Cell-Based Sensors)
Show Figures

Graphical abstract

Back to TopTop