Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (80)

Search Parameters:
Keywords = micro computed tomography (μCT )

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
11 pages, 1704 KiB  
Article
Impact of Aging on Periodontitis Progression: A Murine Model Study of Porphyromonas gingivalis-Induced Alveolar Bone Loss
by Mitsutaka Nishimura, Motohiro Komaki, Shuntaro Sugihara and Toshiro Kodama
Oral 2025, 5(3), 51; https://doi.org/10.3390/oral5030051 - 10 Jul 2025
Viewed by 299
Abstract
Background: Periodontitis is a chronic inflammatory disease influenced by host aging, yet the specific effects of aging on disease susceptibility remain unclear. Objective: This study aimed to evaluate whether aging increases susceptibility to Porphyromonas gingivalis (P. gingivalis)-induced periodontitis in [...] Read more.
Background: Periodontitis is a chronic inflammatory disease influenced by host aging, yet the specific effects of aging on disease susceptibility remain unclear. Objective: This study aimed to evaluate whether aging increases susceptibility to Porphyromonas gingivalis (P. gingivalis)-induced periodontitis in a murine model. We formulated the null hypothesis that age does not affect susceptibility to periodontal bone loss. Methods: Young (8 weeks) and aged (78 weeks) male C57BL/6 mice were randomly assigned into four groups: young control, young infected, old control, and old infected (n = 8 per group, except for old control, where n = 7). Experimental periodontitis was induced by oral application of P. gingivalis suspended in 5% carboxymethylcellulose (CMC), administered every other day, for a total of three applications. Alveolar bone loss was assessed 39 days after the last inoculation using histomorphometric measurement of buccal distance from the cemento-enamel junction to the alveolar bone crest (CEJ–ABC distance) and micro-computed tomography (μCT) at mesial and distal interdental sites. Bonferroni’s correction was applied to the Mann–Whitney U Test to determine statistical significance. A p-value of less than 0.05 was considered statistically significant. Results: Morphometric analysis showed significantly greater buccal bone loss in infected mice versus controls in both age groups (young: 0.193 mm vs. 0.100 mm, p < 0.01; old: 0.262 mm vs. 0.181 mm, p < 0.01). μCT analysis revealed that interdental bone loss was significant only in aged infected mice (mesial: 0.155 mm vs. 0.120 mm, p < 0.05; distal: 0.185 mm vs. 0.100 mm, p < 0.01), and not significant in young infected mice. Conclusions: Aging significantly exacerbates P. gingivalis-induced alveolar bone loss, particularly in interdental regions. These results allowed us to reject the null hypothesis. This study validates a clinically relevant murine model for analyzing age-related periodontitis and provides a foundation for investigating underlying molecular mechanisms and potential therapeutic interventions. Full article
Show Figures

Graphical abstract

18 pages, 12112 KiB  
Article
MgO–C Refractories with Al2O3 and TiO2 Nano-Additives: Insights from X-Ray Micro-Computed Tomography and Conventional Techniques for Assessing Corrosion and Oxidation
by Sevastia Gkiouzel, Vasileios Ioannou, Christina Gioti, Konstantinos C. Vasilopoulos, Angelos Ntaflos, Alkiviadis S. Paipetis, Constantinos E. Salmas and Michael A. Karakassides
Nanomanufacturing 2025, 5(3), 10; https://doi.org/10.3390/nanomanufacturing5030010 - 9 Jul 2025
Viewed by 251
Abstract
MgO–C refractory materials were developed by incorporating different ratios of alumina/titania nano-additives which were synthesized chemically. Their physical and mechanical properties, oxidation resistance, slag wettability, bulk density, apparent porosity, cold crushing strength, oxidation index, and closed porosity were tested, evaluated, and compared using [...] Read more.
MgO–C refractory materials were developed by incorporating different ratios of alumina/titania nano-additives which were synthesized chemically. Their physical and mechanical properties, oxidation resistance, slag wettability, bulk density, apparent porosity, cold crushing strength, oxidation index, and closed porosity were tested, evaluated, and compared using conventional techniques as well as X-ray micro-computed tomography (µCT). This investigation indicated a slight degradation of physical properties and mechanical strengthening which was stronger for samples with increased alumina content. Oxidation and corrosion extent were tested both with X-ray tomography and conventional methods. The first method allowed for the calculation of the oxidation index, the detection of closed porosity, and an improved analysis of the internal corrosion, avoiding the sectioning of the materials. This result confirms the supremacy of the first technique. On the contrary, although conventional methods such as the Archimedes procedure cannot detect close porosity, they provide more accurate measurements of the physical properties of refractories. This study shows that conventional methods exhibit superiority in investigations of the pore structures of refractories for pore sizes in the range 1–2 μm, while the use of the μCT system is limited for pore sizes equal to or larger than 20 μm. Full article
Show Figures

Figure 1

20 pages, 6149 KiB  
Article
In Situ and Laboratory Testing of Boom Clay at Shallow Depths in Belgium
by Maria Konstadinou, Etienne A. Alderlieste, Cor Zwanenburg, Cihan Cengiz, Anderson Peccin da Silva and Charlotte J. W. van Verseveld
Geotechnics 2025, 5(2), 23; https://doi.org/10.3390/geotechnics5020023 - 28 Mar 2025
Viewed by 1034
Abstract
The shear strength and compression properties of stiff Boom clay from Belgium at a depth of about 16.5 to 28 m were investigated by means of cone penetration and laboratory testing. The latter consisted of index classification, constant rate of strain, triaxial, direct [...] Read more.
The shear strength and compression properties of stiff Boom clay from Belgium at a depth of about 16.5 to 28 m were investigated by means of cone penetration and laboratory testing. The latter consisted of index classification, constant rate of strain, triaxial, direct simple shear and unconfined compression tests. The Boom clay samples exhibited strong swelling tendencies. The suction pressure was measured via different procedures and was compared to the expected in situ stress. The undrained shear strength profile determined from cone penetration tests (CPTs) was not compatible with the triaxial and direct simple shear measurements, which gave significantly lower undrained shear strength values. Micro-computed tomography (μCT) scans of the samples showed the presence of pre-existing discontinuities which may cause inconsistencies in the comparison of the laboratory test results with in situ data. The experimental data gathered in this study provide useful information for analyzing the mechanical behaviour of Boom clay at shallow depths considering that most investigations in the literature have been carried out on deep Boom clay deposits. Full article
Show Figures

Figure 1

18 pages, 32050 KiB  
Article
Mineralogical and Micro-Computer Tomographic (μCT) Texture Investigations of Egyptian Blue Spheres (Aguntum, East Tyrol; Retznei and Wagna, Flavia Solva, South Styria)
by Gerald Degenhart, Julius Heinemann, Peter Tropper, Alexandra Rodler-Rørbo, Bianca Zerobin, Martin Auer and Gert Goldenberg
Minerals 2025, 15(3), 302; https://doi.org/10.3390/min15030302 - 15 Mar 2025
Cited by 1 | Viewed by 1024
Abstract
Egyptian Blue was the first synthetic pigment by humankind. It contains of cuprorivaite, which is a calcium-copper-silicate (CaCuSi4O10). This study reports the results of a mineralogical and computer tomographic study of Egyptian Blue finds from Aguntum in East Tyrol [...] Read more.
Egyptian Blue was the first synthetic pigment by humankind. It contains of cuprorivaite, which is a calcium-copper-silicate (CaCuSi4O10). This study reports the results of a mineralogical and computer tomographic study of Egyptian Blue finds from Aguntum in East Tyrol along with Retznei and Wagna (formerly Flavia Solva) from southern Styria in Austria. The present work aims to extend our understanding of the processes involved in the production of the artificial pigment Egyptian Blue. The samples were investigated with respect to their elemental composition and spatial distribution of the calcium-copper-silicate cuprorivaite CaCuSi4O10 and then compared with data from previous studies. Thin sections of an Egyptian Blue sphere from Aguntum were examined using optical microscopy (OP), micro-X-ray fluorescence analysis (μ-XRF) and scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM-EDX). The pigment’s initial mixture as well as the manufacturing process seem to be the decisive factor for the quality of the final product. A relationship between the presence of trace iron (Fe) and titanium (Ti) with the quartz and copper source of the initial mixture is discussed. SEM-EDX analysis revealed that cuprite (Cu2O) was used as a copper source. In addition, micro-computed tomography (µCT) of the Egyptian Blue finds (Aguntum, Retznei, Wagna-Flavia Solva) was performed. Hence, revealing several concise differences between the samples. Texture and volumetric results show a distinctive difference in cuprorivaite content and particle size. To better analyse the spatial distribution, µCT-3D images of the individual mineral phases identified within each sample were obtained. The clear differences in the results may not only enable a differentiation of the production process but also show another potential of non-destructive µCT for assessment of archaeological findings. Full article
Show Figures

Figure 1

12 pages, 4197 KiB  
Article
Estimation of Trabecular Bone Volume with Dual-Echo Ultrashort Echo Time (UTE) Magnetic Resonance Imaging (MRI) Significantly Correlates with High-Resolution Computed Tomography (CT)
by Karen Y. Cheng, Dina Moazamian, Behnam Namiranian, Hamidreza Shaterian Mohammadi, Salem Alenezi, Christine B. Chung and Saeed Jerban
J. Imaging 2025, 11(2), 57; https://doi.org/10.3390/jimaging11020057 - 13 Feb 2025
Viewed by 1115
Abstract
Trabecular bone architecture has important implications for the mechanical strength of bone. Trabecular elements appear as signal void when imaged utilizing conventional magnetic resonance imaging (MRI) sequences. Ultrashort echo time (UTE) MRI can acquire high signal from trabecular bone, allowing for quantitative evaluation. [...] Read more.
Trabecular bone architecture has important implications for the mechanical strength of bone. Trabecular elements appear as signal void when imaged utilizing conventional magnetic resonance imaging (MRI) sequences. Ultrashort echo time (UTE) MRI can acquire high signal from trabecular bone, allowing for quantitative evaluation. However, the trabecular morphology is often disturbed in UTE-MRI due to chemical shift artifacts caused by the presence of fat in marrow. This study aimed to evaluate a UTE-MRI technique to estimate the trabecular bone volume fraction (BVTV) without requiring trabecular-level morphological assessment. A total of six cadaveric distal tibial diaphyseal trabecular bone cubes were scanned using a dual-echo UTE Cones sequence (TE = 0.03 and 2.2 ms) on a clinical 3T MRI scanner and on a micro-computed tomography (μCT) scanner. The BVTV was calculated from 10 consecutive slices on both the MR and μCT images. BVTV calculated from the MR images showed strongly significant correlation with the BVTV determined from μCT images (R = 0.84, p < 0.01), suggesting that UTE-MRI is a feasible technique for the assessment of trabecular bone microarchitecture. This would allow for the non-invasive assessment of information regarding bone strength, and UTE-MRI may potentially serve as a novel tool for assessment of fracture risk. Full article
(This article belongs to the Special Issue Advances and Challenges in Bone Imaging)
Show Figures

Figure 1

17 pages, 2419 KiB  
Article
Sericin’s Potential in Osteoporosis Management: The Roles of L-Serine and D-Serine in Bone Metabolism Regulation
by Jwa-Young Kim, Xiangguo Che, Shihyun Kim, Jongho Choi, Joon Ha Lee, Ji-Hae Lee, HaeYong Kweon, Suk Keun Lee, Je-Yong Choi and Seong-Gon Kim
Nutrients 2025, 17(3), 574; https://doi.org/10.3390/nu17030574 - 4 Feb 2025
Cited by 1 | Viewed by 1478
Abstract
Background: Osteoporosis is a bone remodeling disease characterized by an imbalance between bone formation and resorption, leading to bone fragility. Current treatments focus on bone resorption suppression but often have adverse effects. This study aimed to explore the potential of sericin, a silkworm-derived [...] Read more.
Background: Osteoporosis is a bone remodeling disease characterized by an imbalance between bone formation and resorption, leading to bone fragility. Current treatments focus on bone resorption suppression but often have adverse effects. This study aimed to explore the potential of sericin, a silkworm-derived protein, as a dual-action therapeutic agent that enhances bone formation through its component L-serine and inhibits bone resorption via D-serine, which is derived from L-serine by the action of serine racemase. Methods: Cellular experiments were conducted to evaluate the effects of L-serine on osteoblast differentiation and D-serine on osteoclast inhibition. Serum levels of D-serine were measured following sericin administration in an osteoporosis animal model. μ-CT analysis assessed trabecular and cortical bone quality, and bone-related protein expression was analyzed using immunoprecipitation-based high-performance liquid chromatography (IP-HPLC). Results: L-serine significantly upregulated osteogenic markers, including alkaline phosphatase (ALP), Runx2, osterix, and Col1a1, in osteoblasts (p < 0.05). D-serine inhibited osteoclast activation by suppressing cathepsin K expression (p < 0.001). Sericin feeding elevated serum D-serine levels (p < 0.001) and upregulated bone-related proteins such as BMP-2, osterix, and Runx2. Micro-computed tomography (μ-CT) analysis revealed significant improvements in trabecular bone parameters in the OVX-sericin group, including increased trabecular bone volume (Tb.BV/TV; p < 0.05) and reduced trabecular separation (Tb.Sp; p < 0.05), compared to the OVX and OVX-amino acid groups. Cortical bone parameters, including cortical bone volume (Ct.BV/TV) and cortical area (Ct.Ar), did not significantly differ among OVX groups, but all were lower than in the sham group (p < 0.05). Conclusions: This study demonstrates that sericin modulates bone metabolism by enhancing osteoblast activity through L-serine and inhibiting osteoclastogenesis via D-serine. Sericin supplementation improved trabecular bone mass in an osteoporosis model, highlighting its potential for bone health. Full article
(This article belongs to the Section Proteins and Amino Acids)
Show Figures

Figure 1

20 pages, 14992 KiB  
Article
Macro-Micro Mechanics of Granular Soils Under Shear Considering Coupled Effects of Particle Size Distribution and Particle Morphology
by Wei Xiong and Jianfeng Wang
Materials 2025, 18(2), 428; https://doi.org/10.3390/ma18020428 - 17 Jan 2025
Viewed by 854
Abstract
This paper investigates the effects of particle morphology (PM) and particle size distribution (PSD) on the micro-macro mechanical behaviours of granular soils through a novel X-ray micro-computed tomography (μCT)-based discrete element method (DEM) technique. This technique contains the grain-scale property extraction by the [...] Read more.
This paper investigates the effects of particle morphology (PM) and particle size distribution (PSD) on the micro-macro mechanical behaviours of granular soils through a novel X-ray micro-computed tomography (μCT)-based discrete element method (DEM) technique. This technique contains the grain-scale property extraction by the X-ray μCT, DEM parameter calibration by the one-to-one mapping technique, and the massive derivative DEM simulations. In total, 25 DEM samples were generated with a consideration of six PSDs and four PMs. The effects of PSD and PM on the micro-macro mechanical behaviours were carefully investigated, and the coupled effects were highlighted. It is found that (a) PM plays a significant role in the micro-macro mechanical responses of granular soils under triaxial shear; (b) the PSD uniformity can enhance the particle morphology effect in dictating the peak deviatoric stress, maximum volumetric strain, contact-based coordination number, fabric evolution, and shear band formation, while showing limited influences in the maximum dilation angle and particle-based coordination number; (c) with the same PSD uniformity and PM degree, the mean particle volume shows minimal effects on the macro-micro mechanical behaviours of granular soils as well as the particle morphology effects. Full article
Show Figures

Figure 1

21 pages, 2586 KiB  
Article
Changes in the Antibacterial Performance of Polymer-Based Nanocomposites Induced by Additive Manufacturing Processing
by Ana C. Pinho, Paula V. Morais, Manuel F. Pereira and Ana P. Piedade
Polymers 2025, 17(2), 171; https://doi.org/10.3390/polym17020171 - 11 Jan 2025
Cited by 1 | Viewed by 1177
Abstract
The idea supporting the investigation of the current manuscript was to develop customized filters for air conditioners with different pore percentages and geometry with the additional advantage of presenting antibacterial performance. This property was expected due to the reinforcement of Cu nanoparticles in [...] Read more.
The idea supporting the investigation of the current manuscript was to develop customized filters for air conditioners with different pore percentages and geometry with the additional advantage of presenting antibacterial performance. This property was expected due to the reinforcement of Cu nanoparticles in the polymeric matrix of poly(lactic acid) (PLA) and polyurethane (TPU). The filaments were characterized by their chemical composition, thermal and mechanical properties, and antibacterial behavior before and after processing by fused filament fabrication. An X-ray photoelectron spectroscopy showed that the nanocomposite filaments presented Cu particles at their surface in different valence states, including Cu0, Cu+, and Cu2+. After processing, the metallic particles are almost absent from the surface, a result confirmed by micro-computer tomography (μ-CT) characterization. Antibacterial tests were made using solid-state diffusion tests to mimic the dry environment in air conditioner filters. The tests with the nanocomposite filaments showed that bacteria proliferation was hindered. However, no antibacterial performance could be observed after processing due to the absence of the metallic element on the surface. Nevertheless, antimicrobial performance was observed when evaluated in liquid tests. Therefore, the obtained results provide valuable indications for developing new nanocomposites that must maintain their antimicrobial activity after being processed and tested in the dry conditions of solid-state diffusion. Full article
(This article belongs to the Section Polymer Processing and Engineering)
Show Figures

Figure 1

25 pages, 9394 KiB  
Article
Transmitted Light Measurement to Determine the Local Structural Characteristics of Paperboard: Grammage, Thickness, and Fiber Orientation
by Cedric W. Sanjon, Yuchen Leng, Marek Hauptmann, Peter Groche and Jens-Peter Majschak
Fibers 2024, 12(12), 113; https://doi.org/10.3390/fib12120113 - 23 Dec 2024
Viewed by 1400
Abstract
This study presents a novel transmission-based method for characterizing local structural features, including the grammage, thickness, and fiber orientation, of paper materials. Some non-destructive techniques, such as micro-computed tomography (μ-CT), microscopy, and radiation-based methods, are costly, time-consuming, and lack the ability [...] Read more.
This study presents a novel transmission-based method for characterizing local structural features, including the grammage, thickness, and fiber orientation, of paper materials. Some non-destructive techniques, such as micro-computed tomography (μ-CT), microscopy, and radiation-based methods, are costly, time-consuming, and lack the ability to provide comprehensive local structural information within a single measurement. The proposed method utilizes a single light transmission measurement to assess local grammage and thickness through histogram matching with reference data obtained via β-radiography and profilometry. The same light transmission images are also used to determine local fiber orientation, employing image analysis techniques. The structure tensor method, which analyzes gradients of light transmission images, provides detailed insight into the local fiber orientation. The results show that thickness and grammage measurements are independent of which side of the paper is evaluated, while the fiber orientation distribution varies between the front and back sides, reflecting differences in fiber arrangement due to manufacturing processes. Various distribution functions are compared, and the Pearson Type 3, log-normal, and gamma distributions are found to most accurately describe the grammage, thickness, and fiber orientation distributions. The study includes a variety of paper types, ensuring a robust and comprehensive analysis of material behavior, and confirms that the method can effectively infer the inhomogeneous features from a single light transmission measurement. Full article
Show Figures

Figure 1

24 pages, 8477 KiB  
Article
Biomedical Composites of Polycaprolactone/Hydroxyapatite for Bioplotting: Comprehensive Interpretation of the Reinforcement Course
by Markos Petousis, Nikolaos Michailidis, Apostolos Korlos, Vassilis Papadakis, Constantine David, Dimitrios Sagris, Nikolaos Mountakis, Apostolos Argyros, John Valsamos and Nectarios Vidakis
Polymers 2024, 16(17), 2400; https://doi.org/10.3390/polym16172400 - 24 Aug 2024
Cited by 3 | Viewed by 3934
Abstract
Robust materials in medical applications are sought after and researched, especially for 3D printing in bone tissue engineering. Poly[ε-caprolactone] (PCL) is a commonly used polymer for scaffolding and other medical uses. Its strength is a drawback compared to other polymers. Herein, PCL was [...] Read more.
Robust materials in medical applications are sought after and researched, especially for 3D printing in bone tissue engineering. Poly[ε-caprolactone] (PCL) is a commonly used polymer for scaffolding and other medical uses. Its strength is a drawback compared to other polymers. Herein, PCL was mixed with hydroxyapatite (HAp). Composites were developed at various concentrations (0.0–8.0 wt. %, 2.0 step), aiming to enhance the strength of PCL with a biocompatible additive in bioplotting. Initially, pellets were derived from the shredding of filaments extruded after mixing PCL and HAp at predetermined quantities for each composite. Specimens were then manufactured by bioplotting 3D printing. The samples were tested for their thermal and rheological properties and were also mechanically, morphologically, and chemically examined. The mechanical properties included tensile and flexural investigations, while morphological and chemical examinations were carried out employing scanning electron microscopy and energy dispersive spectroscopy, respectively. The structure of the manufactured specimens was analyzed using micro-computed tomography with regard to both their dimensional deviations and voids. PCL/HAp 6.0 wt. % was the composite that showed the most enhanced mechanical (14.6% strength improvement) and structural properties, proving the efficiency of HAp as a reinforcement filler in medical applications. Full article
(This article belongs to the Section Polymer Applications)
Show Figures

Figure 1

16 pages, 16781 KiB  
Article
Multi-Channel Microscale Nerve Cuffs for Spatially Selective Neuromodulation
by Morgan Riley, FNU Tala, Katherine J. Johnson and Benjamin C. Johnson
Micromachines 2024, 15(8), 1036; https://doi.org/10.3390/mi15081036 - 15 Aug 2024
Viewed by 1563
Abstract
Peripheral nerve modulation via electrical stimulation shows promise for treating several diseases, but current approaches lack selectivity, leading to side effects. Exploring selective neuromodulation with commercially available nerve cuffs is impractical due to their high cost and limited spatial resolution. While custom cuffs [...] Read more.
Peripheral nerve modulation via electrical stimulation shows promise for treating several diseases, but current approaches lack selectivity, leading to side effects. Exploring selective neuromodulation with commercially available nerve cuffs is impractical due to their high cost and limited spatial resolution. While custom cuffs reported in the literature achieve high spatial resolutions, they require specialized microfabrication equipment and significant effort to produce even a single design. This inability to rapidly and cost-effectively prototype novel cuff designs impedes research into selective neuromodulation therapies in acute studies. To address this, we developed a reproducible method to easily create multi-channel epineural nerve cuffs for selective fascicular neuromodulation. Leveraging commercial flexible printed circuit (FPC) technology, we created cuffs with high spatial resolution (50 μm) and customizable parameters like electrode size, channel count, and cuff diameter. We designed cuffs to accommodate adult mouse or rat sciatic nerves (300–1500 μm diameter). We coated the electrodes with PEDOT:PSS to improve the charge injection capacity. We demonstrated selective neuromodulation in both rats and mice, achieving preferential activation of the tibialis anterior (TA) and lateral gastrocnemius (LG) muscles. Selectivity was confirmed through micro-computed tomography (μCT) and quantified through a selectivity index. These results demonstrate the potential of this fabrication method for enabling selective neuromodulation studies while significantly reducing production time and costs compared to traditional approaches. Full article
(This article belongs to the Special Issue Neural Interface: From Material to System)
Show Figures

Figure 1

27 pages, 8222 KiB  
Article
Promotion of Bone Formation in a Rat Osteoporotic Vertebral Body Defect Model via Suppression of Osteoclastogenesis by Ectopic Embryonic Calvaria Derived Mesenchymal Stem Cells
by Yerin Yu, Somin Lee, Minsung Bock, Seong Bae An, Hae Eun Shin, Jong Seop Rim, Jun-oh Kwon, Kwang-Sook Park and Inbo Han
Int. J. Mol. Sci. 2024, 25(15), 8174; https://doi.org/10.3390/ijms25158174 - 26 Jul 2024
Cited by 1 | Viewed by 1818
Abstract
Osteoporotic vertebral compression fractures (OVCFs) are the most prevalent fractures among patients with osteoporosis, leading to severe pain, deformities, and even death. This study explored the use of ectopic embryonic calvaria derived mesenchymal stem cells (EE-cMSCs), which are known for their superior differentiation [...] Read more.
Osteoporotic vertebral compression fractures (OVCFs) are the most prevalent fractures among patients with osteoporosis, leading to severe pain, deformities, and even death. This study explored the use of ectopic embryonic calvaria derived mesenchymal stem cells (EE-cMSCs), which are known for their superior differentiation and proliferation capabilities, as a potential treatment for bone regeneration in OVCFs. We evaluated the impact of EE-cMSCs on osteoclastogenesis in a RAW264.7 cell environment, which was induced by the receptor activator of nuclear factor kappa-beta ligand (RANKL), using cytochemical staining and quantitative real-time PCR. The osteogenic potential of EE-cMSCs was evaluated under various hydrogel conditions. An osteoporotic vertebral body bone defect model was established by inducing osteoporosis in rats through bilateral ovariectomy and creating defects in their coccygeal vertebral bodies. The effects of EE-cMSCs were examined using micro-computed tomography (μCT) and histology, including immunohistochemical analyses. In vitro, EE-cMSCs inhibited osteoclast differentiation and promoted osteogenesis in a 3D cell culture environment using fibrin hydrogel. Moreover, μCT and histological staining demonstrated increased new bone formation in the group treated with EE-cMSCs and fibrin. Immunostaining showed reduced osteoclast activity and bone resorption, alongside increased angiogenesis. Thus, EE-cMSCs can effectively promote bone regeneration and may represent a promising therapeutic approach for treating OVCFs. Full article
(This article belongs to the Special Issue Musculoskeletal Development and Skeletal Pathophysiologies 2.0)
Show Figures

Figure 1

12 pages, 4230 KiB  
Review
Imaging, Dynamic Histomorphometry, and Mechanical Testing in Preclinical Bone Research
by Mikkel Bo Brent
Osteology 2024, 4(3), 120-131; https://doi.org/10.3390/osteology4030010 - 24 Jul 2024
Cited by 1 | Viewed by 2172
Abstract
Advanced laboratory methods play a crucial role in bone research, allowing researchers and scientists to study the complex biology and nature of the skeleton. Dual-energy X-ray absorptiometry (DXA) is a non-invasive method of measuring bone mass, which is an important parameter for the [...] Read more.
Advanced laboratory methods play a crucial role in bone research, allowing researchers and scientists to study the complex biology and nature of the skeleton. Dual-energy X-ray absorptiometry (DXA) is a non-invasive method of measuring bone mass, which is an important parameter for the diagnosis and treatment of several bone diseases. Micro-computed tomography (μCT) is a very high-resolution technique that can be used to investigate the 3D microstructure of trabecular bone. Dynamic bone histomorphometry is used to assess histological indices of bone formation and resorption using fluorochromes embedded into newly formed bone. Mechanical testing is used to measure bone strength and stiffness, providing important information about bone quality and fracture risk. All these methods are widely used in preclinical in vivo studies using rodents and in most clinical studies. Therefore, it is important for both researchers and scientists within the field of bone biology, and those in neighboring fields, to be familiar with their use, strengths, limitations, and important technical aspects. Several guidelines and protocols about the topic have been published, but are very exhaustive. The present review aimed to provide instructions for early-career researchers and outline important concepts and technical aspects of DXA, μCT, dynamic bone histomorphometry, and mechanical testing in bone research. Full article
Show Figures

Figure 1

17 pages, 8343 KiB  
Article
Ultrastructure and Spectral Characteristics of the Compound Eye of Asiophrida xanthospilota (Baly, 1881) (Coleoptera, Chrysomelidae)
by Zu-Long Liang, Tian-Hao Zhang, Jacob Muinde, Wei-Li Fan, Ze-Qun Dong, Feng-Ming Wu, Zheng-Zhong Huang and Si-Qin Ge
Insects 2024, 15(7), 532; https://doi.org/10.3390/insects15070532 - 13 Jul 2024
Cited by 1 | Viewed by 2026
Abstract
In this study, the morphology and ultrastructure of the compound eye of Asi. xanthospilota were examined by using scanning electron microscopy (SEM), transmission electron microscopy (TEM), micro-computed tomography (μCT), and 3D reconstruction. Spectral sensitivity was investigated by electroretinogram (ERG) tests and phototropism experiments. [...] Read more.
In this study, the morphology and ultrastructure of the compound eye of Asi. xanthospilota were examined by using scanning electron microscopy (SEM), transmission electron microscopy (TEM), micro-computed tomography (μCT), and 3D reconstruction. Spectral sensitivity was investigated by electroretinogram (ERG) tests and phototropism experiments. The compound eye of Asi. xanthospilota is of the apposition type, consisting of 611.00 ± 17.53 ommatidia in males and 634.8 0 ± 24.73 ommatidia in females. Each ommatidium is composed of a subplano-convex cornea, an acone consisting of four cone cells, eight retinular cells along with the rhabdom, two primary pigment cells, and about 23 secondary pigment cells. The open type of rhabdom in Asi. xanthospilota consists of six peripheral rhabdomeres contributed by the six peripheral retinular cells (R1~R6) and two distally attached rhabdomeric segments generated solely by R7, while R8 do not contribute to the rhabdom. The orientation of microvilli indicates that Asi. xanthospilota is unlikely to be a polarization-sensitive species. ERG testing showed that both males and females reacted to stimuli from red, yellow, green, blue, and ultraviolet light. Both males and females exhibited strong responses to blue and green light but weak responses to red light. The phototropism experiments showed that both males and females exhibited positive phototaxis to all five lights, with blue light significantly stronger than the others. Full article
(This article belongs to the Section Insect Systematics, Phylogeny and Evolution)
Show Figures

Figure 1

15 pages, 4331 KiB  
Article
Comparative Analysis of Micro-Computed Tomography and 3D Micro-Ultrasound for Measurement of the Mouse Aorta
by Hajar A. Alenezi, Karen E. Hemmings, Parkavi Kandavelu, Joanna Koch-Paszkowski and Marc A. Bailey
J. Imaging 2024, 10(6), 145; https://doi.org/10.3390/jimaging10060145 - 17 Jun 2024
Viewed by 1475
Abstract
Aortic aneurysms, life-threatening and often undetected until they cause sudden death, occur when the aorta dilates beyond 1.5 times its normal size. This study used ultrasound scans and micro-computed tomography to monitor and measure aortic volume in preclinical settings, comparing it to the [...] Read more.
Aortic aneurysms, life-threatening and often undetected until they cause sudden death, occur when the aorta dilates beyond 1.5 times its normal size. This study used ultrasound scans and micro-computed tomography to monitor and measure aortic volume in preclinical settings, comparing it to the well-established measurement using ultrasound scans. The reproducibility of measurements was also examined for intra- and inter-observer variability, with both modalities used on 8-week-old C57BL6 mice. For inter-observer variability, the μCT (micro-computed tomography) measurements for the thoracic, abdominal, and whole aorta between observers were highly consistent, showing a strong positive correlation (R2 = 0.80, 0.80, 0.95, respectively) and no significant variability (p-value: 0.03, 0.03, 0.004, respectively). The intra-observer variability for thoracic, abdominal, and whole aorta scans demonstrated a significant positive correlation (R2 = 0.99, 0.96, 0.87, respectively) and low variability (p-values = 0.0004, 0.002, 0.01, respectively). The comparison between μCT and USS (ultrasound) in the suprarenal and infrarenal aorta showed no significant difference (p-value = 0.20 and 0.21, respectively). μCT provided significantly higher aortic volume measurements compared to USS. The reproducibility of USS and μCT measurements was consistent, showing minimal variance among observers. These findings suggest that μCT is a reliable alternative for comprehensive aortic phenotyping, consistent with clinical findings in human data. Full article
(This article belongs to the Section Medical Imaging)
Show Figures

Figure 1

Back to TopTop