Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (16)

Search Parameters:
Keywords = in-tube solid-phase microextraction (IT-SPME)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
21 pages, 4395 KiB  
Review
Developments and Applications of Molecularly Imprinted Polymer-Based In-Tube Solid Phase Microextraction Technique for Efficient Sample Preparation
by Hiroyuki Kataoka, Atsushi Ishizaki, Keita Saito and Kentaro Ehara
Molecules 2024, 29(18), 4472; https://doi.org/10.3390/molecules29184472 - 20 Sep 2024
Cited by 7 | Viewed by 2671
Abstract
Despite advancements in the sensitivity and performance of analytical instruments, sample preparation remains a bottleneck in the analytical process. Currently, solid-phase extraction is more widely used than traditional organic solvent extraction due to its ease of use and lower solvent requirements. Moreover, various [...] Read more.
Despite advancements in the sensitivity and performance of analytical instruments, sample preparation remains a bottleneck in the analytical process. Currently, solid-phase extraction is more widely used than traditional organic solvent extraction due to its ease of use and lower solvent requirements. Moreover, various microextraction techniques such as micro solid-phase extraction, dispersive micro solid-phase extraction, solid-phase microextraction, stir bar sorptive extraction, liquid-phase microextraction, and magnetic bead extraction have been developed to minimize sample size, reduce solvent usage, and enable automation. Among these, in-tube solid-phase microextraction (IT-SPME) using capillaries as extraction devices has gained attention as an advanced “green extraction technique” that combines miniaturization, on-line automation, and reduced solvent consumption. Capillary tubes in IT-SPME are categorized into configurations: inner-wall-coated, particle-packed, fiber-packed, and rod monolith, operating either in a draw/eject system or a flow-through system. Additionally, the developments of novel adsorbents such as monoliths, ionic liquids, restricted-access materials, molecularly imprinted polymers (MIPs), graphene, carbon nanotubes, inorganic nanoparticles, and organometallic frameworks have improved extraction efficiency and selectivity. MIPs, in particular, are stable, custom-made polymers with molecular recognition capabilities formed during synthesis, making them exceptional “smart adsorbents” for selective sample preparation. The MIP fabrication process involves three main stages: pre-arrangement for recognition capability, polymerization, and template removal. After forming the template-monomer complex, polymerization creates a polymer network where the template molecules are anchored, and the final step involves removing the template to produce an MIP with cavities complementary to the template molecules. This review is the first paper to focus on advanced MIP-based IT-SPME, which integrates the selectivity of MIPs into efficient IT-SPME, and summarizes its recent developments and applications. Full article
(This article belongs to the Special Issue Applications of Solid-Phase Microextraction and Related Techniques)
Show Figures

Figure 1

19 pages, 2672 KiB  
Article
Simultaneous Determination of Tobacco Smoke Exposure and Stress Biomarkers in Saliva Using In-Tube SPME and LC-MS/MS for the Analysis of the Association between Passive Smoking and Stress
by Hiroyuki Kataoka, Saori Miyata and Kentaro Ehara
Molecules 2024, 29(17), 4157; https://doi.org/10.3390/molecules29174157 - 2 Sep 2024
Cited by 1 | Viewed by 2466
Abstract
Passive smoking from environmental tobacco smoke not only increases the risk of lung cancer and cardiovascular disease but may also be a stressor triggering neuropsychiatric and other disorders. To prevent these diseases, understanding the relationship between passive smoking and stress is vital. In [...] Read more.
Passive smoking from environmental tobacco smoke not only increases the risk of lung cancer and cardiovascular disease but may also be a stressor triggering neuropsychiatric and other disorders. To prevent these diseases, understanding the relationship between passive smoking and stress is vital. In this study, we developed a simple and sensitive method to simultaneously measure nicotine (Nic) and cotinine (Cot) as tobacco smoke exposure biomarkers, and cortisol (CRT), serotonin (5-HT), melatonin (MEL), dopamine (DA), and oxytocin (OXT) as stress-related biomarkers. These were extracted and concentrated from saliva by in-tube solid-phase microextraction (IT-SPME) using a Supel-Q PLOT capillary as the extraction device, then separated and detected within 6 min by liquid chromatography–tandem mass spectrometry (LC−MS/MS) using a Kinetex Biphenyl column (Phenomenex Inc., Torrance, CA, USA). Limits of detection (S/N = 3) for Nic, Cot, CRT, 5-HT, MEL, DA, and OXT were 0.22, 0.12, 0.78, 0.39, 0.45, 1.4, and 3.7 pg mL−1, respectively, with linearity of calibration curves in the range of 0.01–25 ng mL−1 using stable isotope-labeled internal standards. Intra- and inter-day reproducibilities were under 7.9% and 14.6% (n = 5) relative standard deviations, and compound recoveries in spiked saliva samples ranged from 82.1 to 106.6%. In thirty nonsmokers, Nic contents positively correlated with CRT contents (R2 = 0.5264, n = 30), while no significant correlation was found with other biomarkers. The standard deviation of intervals between normal beats as the standard measure of heart rate variability analysis negatively correlated with CRT contents (R2 = 0.5041, n = 30). After passive smoke exposure, Nic levels transiently increased, Cot and CRT levels rose over time, and 5-HT, DA, and OXT levels decreased. These results indicate tobacco smoke exposure acts as a stressor in nonsmokers. Full article
(This article belongs to the Special Issue Applications of Solid-Phase Microextraction and Related Techniques)
Show Figures

Figure 1

15 pages, 1506 KiB  
Article
Assessing the Dissipation of Pesticides of Different Polarities in Soil Samples
by Carlos Eduardo Rodríguez-Palma, Pilar Campíns-Falcó and Rosa Herráez-Hernández
Soil Syst. 2024, 8(3), 71; https://doi.org/10.3390/soilsystems8030071 - 24 Jun 2024
Cited by 2 | Viewed by 1295
Abstract
A methodology has been developed to assess the presence and dissipation of herbicides of a wide range of polarities in soil using in-tube solid-phase microextraction (IT-SPME) coupled online to capillary liquid chromatography (capLC). The compounds investigated were tritosulfuron (TRT), triflusulfuron-methyl (TRF), aclonifen (ACL), [...] Read more.
A methodology has been developed to assess the presence and dissipation of herbicides of a wide range of polarities in soil using in-tube solid-phase microextraction (IT-SPME) coupled online to capillary liquid chromatography (capLC). The compounds investigated were tritosulfuron (TRT), triflusulfuron-methyl (TRF), aclonifen (ACL), and bifenox (BF), with log octanol-water partition coefficients (log Kow) ranging from 0.62 to 4.48. The method provided suitable linearity at concentration levels of 0.5–4.0 µg/g for TRT and TRF, and 0.2–1.0 µg/g for ACL and BF, and intra- and interday precision (expressed as relative standard deviation) ≤4% and ≤8%, respectively. The mean recoveries ranged from 90% to 101%, and the limits of detection (LODs) and quantification (LOQs) were in the intervals of 0.05–0.1 µg/g and 0.1–0.4 µg/g, respectively. The accuracy of the method was also satisfactory. The proposed approach was successfully applied to assess the degradation of the tested herbicides in different types of soil (agricultural, urban and forest) after being exposed to different laboratory and outdoor conditions. The results obtained showed a greater persistence of the most apolar compounds ACL and BF, with percentages of degraded herbicide ≤31% regardless of the soil characteristics. In contrast, a significant degradation of highly polar herbicides TRT and TRF was observed in soils with the lowest organic matter, even after a few days of exposure. For example, the percentages of remaining TRT and TRF in this kind of soil after 20 days were ≤65%; the half-life time of TRF was only 24.8 days. These results indicate that the proposed approach can be considered as an effective tool for a better understanding of soil pollution. Full article
Show Figures

Figure 1

12 pages, 2359 KiB  
Article
Determination of Luteolin and Apigenin in Herbal Teas by Online In-Tube Solid-Phase Microextraction Coupled with LC–MS/MS
by Atsushi Ishizaki, Akiko Miura and Hiroyuki Kataoka
Foods 2024, 13(11), 1687; https://doi.org/10.3390/foods13111687 - 28 May 2024
Cited by 4 | Viewed by 2662
Abstract
Herbal teas have attracted attention as functional beverages containing luteolin and apigenin, which exhibit antioxidant and anti-inflammatory effects. The objective of this study was to develop a sensitive online automated method to determine these flavones’ contents in herbal teas using in-tube solid-phase microextraction [...] Read more.
Herbal teas have attracted attention as functional beverages containing luteolin and apigenin, which exhibit antioxidant and anti-inflammatory effects. The objective of this study was to develop a sensitive online automated method to determine these flavones’ contents in herbal teas using in-tube solid-phase microextraction (IT-SPME) coupled with liquid chromatography–tandem mass spectrometry (LC–MS/MS). These compounds were extracted and concentrated by IT-SPME using a Supel Q PLOT capillary column and then separated and detected within 6 min using a CAPCELL PAK C18 MG III analytical column and a negative electrospray ionization-mode multiple-reaction monitoring system by LC–MS/MS. The detection limits (S/N = 3) for luteolin and apigenin were 0.4 and 0.8 pg mL−1, respectively, and the calibration curves were linear in the range of 2–2000 pg mL−1 with correlation coefficients above 0.9995, and intra-day and inter-day precisions with relative standard deviations below 2.9 and 3.6% (n = 6), respectively. The luteolin and apigenin in herbal tea were quantified using IT-SPME/LC-MS/MS following the acid hydrolysis of their glycosides. Among the 10 herbal teas tested, luteolin was detected in peppermint and sage at concentrations of 375 and 99 µg mL−1, respectively, while apigenin was detected in German chamomile at 110 µg mL−1, which were higher than in the other herbal teas. The method is expected to be a useful method for evaluating the efficacy of luteolin and apigenin in herbal teas as functional beverages. Full article
Show Figures

Figure 1

17 pages, 3181 KiB  
Article
Development of Noninvasive Method for the Automated Analysis of Nine Steroid Hormones in Human Saliva by Online Coupling of In-Tube Solid-Phase Microextraction with Liquid Chromatography–Tandem Mass Spectrometry
by Takashi Hitomi and Hiroyuki Kataoka
Analytica 2024, 5(2), 233-249; https://doi.org/10.3390/analytica5020015 - 9 May 2024
Cited by 3 | Viewed by 2173
Abstract
Accurate measurement of steroid hormones is crucial to elucidate new mechanisms of action and diagnose steroid metabolism-related diseases. This study presents a simple, sensitive, and automated analytical method for nine representative steroid hormones. The method involves on-line coupling of in-tube solid-phase microextraction (IT-SPME) [...] Read more.
Accurate measurement of steroid hormones is crucial to elucidate new mechanisms of action and diagnose steroid metabolism-related diseases. This study presents a simple, sensitive, and automated analytical method for nine representative steroid hormones. The method involves on-line coupling of in-tube solid-phase microextraction (IT-SPME) with liquid chromatography–tandem mass spectrometry (LC–MS/MS). The steroid hormones were extracted and enriched on a Supel-Q PLOT capillary column using IT-SPME. Subsequently, they were separated and detected within 6 min using a Discovery HS F5-3 column and positive ion mode multiple reaction monitoring system via LC–MS/MS. Calibration curves of these compounds using each stable isotope-labeled internal standard (IS) showed linearity with correlation coefficients greater than 0.9990 in the range of 0.01–40 ng/mL, with limits of detection (S/N = 3) of 0.7–21 pg/mL. Moreover, intra- and inter-day variations were lower than 8.1 and 15% (n = 6), respectively. The recoveries of these compounds from saliva samples were in the range of 82–114%. The developed IT-SPME/LC–MS/MS method of steroid hormones is a highly sensitive, specific, and non-invasive analytical method that allows extraction and enrichment with no organic solvents, and enables direct automated online analysis by simply ultrafiltrating a small sample of saliva. Full article
(This article belongs to the Section Sample Pretreatment and Extraction)
Show Figures

Figure 1

11 pages, 1324 KiB  
Article
New Green and Sustainable Tool for Assessing Nitrite and Nitrate Amounts in a Variety of Environmental Waters
by H. R. Robles-Jimarez, N. Jornet-Martínez and P. Campíns-Falcó
Water 2023, 15(5), 945; https://doi.org/10.3390/w15050945 - 1 Mar 2023
Cited by 4 | Viewed by 2771
Abstract
This paper aims to provide improved selectivity and sensitivity with a short analysis time of about 10 min and low residues for quantitation of nitrite and nitrate in waters by liquid chromatography. Ion-pair formation and ion exchange retention mechanisms were considered. The optimized [...] Read more.
This paper aims to provide improved selectivity and sensitivity with a short analysis time of about 10 min and low residues for quantitation of nitrite and nitrate in waters by liquid chromatography. Ion-pair formation and ion exchange retention mechanisms were considered. The optimized option was in-tube solid phase microextraction (IT-SPME) by means of a silica capillary of 14 cm length and 0.32 mm id, coupled online with a capillary anion exchange analytical column (Inertsil AX 150 × 0.5 mm id, 5 µm) and the use of their native absorbance. Precision of the retention times expressed as % relative standard deviation (RSD) were <1% for both, nitrite (tR = 5.8 min) and nitrate (tR = 10.5 min). Well, river, channel, lake, sea, tap and bottled waters and several matrices of a drinking water treatment plant were analysed, and no matrix effect was observed for all of them. Inorganic anions and several organic acids were tested as possible interferences and suitable selectivity was obtained. Precision expressed as % relative standard deviation (RSD) was between 0.9 and 3%. Low detection limits of 0.9 and 9 μg/L for nitrite and nitrate were obtained, respectively, and low residue generation near 100 µL per run was also achieved. Full article
(This article belongs to the Special Issue Water Environment Pollution and Control)
Show Figures

Figure 1

12 pages, 1872 KiB  
Article
Online In-Tube Solid-Phase Microextraction Coupled with Liquid Chromatography–Tandem Mass Spectrometry for Automated Analysis of Four Sulfated Steroid Metabolites in Saliva Samples
by Hiroyuki Kataoka and Daiki Nakayama
Molecules 2022, 27(10), 3225; https://doi.org/10.3390/molecules27103225 - 18 May 2022
Cited by 13 | Viewed by 2553
Abstract
Accurate measurement of sulfated steroid metabolite concentrations can not only enable the elucidation of the mechanisms regulating steroid metabolism, but also lead to the diagnosis of various related diseases. The present study describes a simple and sensitive method for the simultaneous determination of [...] Read more.
Accurate measurement of sulfated steroid metabolite concentrations can not only enable the elucidation of the mechanisms regulating steroid metabolism, but also lead to the diagnosis of various related diseases. The present study describes a simple and sensitive method for the simultaneous determination of four sulfated steroid metabolites in saliva, pregnenolone sulfate (PREGS), dehydroepiandrosterone sulfate (DHEAS), cortisol sulfate (CRTS), and 17β-estradiol-3-sulfate (E2S), by online coupling of in-tube solid-phase microextraction (IT-SPME) and stable isotope dilution liquid chromatography–tandem mass spectrometry (LC–MS/MS). These compounds were extracted and concentrated on Supel-Q PLOT capillary tubes by IT-SPME and separated and detected within 6 min by LC–MS/MS using an InertSustain swift C18 column and negative ion mode multiple reaction monitoring systems. These operations were fully automated by an online program. Calibration curves using their stable isotope-labeled internal standards showed good linearity in the range of 0.01–2 ng mL−1 for PREGS, DHEAS, and CRTS and of 0.05–10 ng mL−1 for E2S. The limits of detection (S/N = 3) of PREGS, DHEAS, CRTS, and E2S were 0.59, 0.30, 0.80, and 3.20 pg mL−1, respectively. Moreover, intraday and interday variations were lower than 11.1% (n = 5). The recoveries of these compounds from saliva samples were in the range of 86.6–112.9%. The developed method is highly sensitive and specific and can easily measure sulfated steroid metabolite concentrations in 50 μL saliva samples. Full article
(This article belongs to the Special Issue Solid-Phase Microextraction and Related Techniques in Bioanalysis)
Show Figures

Figure 1

11 pages, 7208 KiB  
Article
Application of Covalent Organic Porous Polymers-Functionalized Basalt Fibers for in-Tube Solid-Phase Microextraction
by Qiong Jiang, Peng Xu, Juanjuan Feng and Min Sun
Molecules 2020, 25(24), 5788; https://doi.org/10.3390/molecules25245788 - 8 Dec 2020
Cited by 15 | Viewed by 3089
Abstract
To establish an online analytical method towards estrogenic pollutants, a covalent organic porous polymer (COP) was in-situ synthesized on the surface of basalt fibers (BFs) for in-tube solid-phase microextraction (IT-SPME). The extraction tube, obtained via placing the modified BFs into a polyetheretherketone tube, [...] Read more.
To establish an online analytical method towards estrogenic pollutants, a covalent organic porous polymer (COP) was in-situ synthesized on the surface of basalt fibers (BFs) for in-tube solid-phase microextraction (IT-SPME). The extraction tube, obtained via placing the modified BFs into a polyetheretherketone tube, was combined with high-performance liquid chromatography (HPLC) to achieve online IT-SPME-HPLC analysis. The important parameters, including sampling volume, sampling rate, organic solvent content and desorption time, were carefully investigated. Under the optimized conditions, the online analytical method was established for five estrogenic targets, with low limits of detection (0.001–0.005 μg/L), high enrichment factors (1800–2493), wide linear ranges (0.003–20, 0.015–20 μg/L) and satisfactory repeatability. It was successfully applied to detect five estrogens in a wastewater sample and a water sample in a polycarbonate cup. The BFs functionalized with COPs displayed excellent extraction effect for estrogenic pollutants, furthermore it has great potential in sample preparation or other fields. Full article
(This article belongs to the Section Analytical Chemistry)
Show Figures

Figure 1

15 pages, 1012 KiB  
Review
Innovations in Extractive Phases for In-Tube Solid-Phase Microextraction Coupled to Miniaturized Liquid Chromatography: A Critical Review
by Henry Daniel Ponce-Rodríguez, Jorge Verdú-Andrés, Rosa Herráez-Hernández and Pilar Campíns-Falcó
Molecules 2020, 25(10), 2460; https://doi.org/10.3390/molecules25102460 - 25 May 2020
Cited by 28 | Viewed by 3861
Abstract
Over the past years, a great effort has been devoted to the development of new sorbents that can be used to pack or to coat extractive capillaries for in-tube solid-phase microextraction (IT-SPME). Many of those efforts have been focused on the preparation of [...] Read more.
Over the past years, a great effort has been devoted to the development of new sorbents that can be used to pack or to coat extractive capillaries for in-tube solid-phase microextraction (IT-SPME). Many of those efforts have been focused on the preparation of capillaries for miniaturized liquid chromatography (LC) due to the reduced availability of capillary columns with appropriate dimensions for this kind of system. Moreover, many of the extractive capillaries that have been used for IT-SPME so far are segments of open columns from the gas chromatography (GC) field, but the phase nature and dimensions are very limited. In particular, polar compounds barely interact with stationary GC phases. Capillary GC columns may also be unsuitable when highly selective extractions are needed. In this work, we provide an overview of the extractive capillaries that have been specifically developed for capillary LC (capLC) and nano LC (nanoLC) to enhance the overall performance of the IT-SPME, the chromatographic separation, and the detection. Different monolithic polymers, such as silica C18 and C8 polymers, molecularly imprinted polymers (MIPs), polymers functionalized with antibodies, and polymers reinforced with different types of carbon nanotubes, metal, and metal oxide nanoparticles (including magnetic nanoparticles), and restricted access materials (RAMs) will be presented and critically discussed. Full article
(This article belongs to the Special Issue Feature Review Articles in Analytical Chemistry-Part I)
Show Figures

Figure 1

19 pages, 9747 KiB  
Article
Estimating Diphenylamine in Gunshot Residues from a New Tool for Identifying both Inorganic and Organic Residues in the Same Sample
by Ana Isabel Argente-García, Lusine Hakobyan, Carmen Guillem and Pilar Campíns-Falcó
Separations 2019, 6(1), 16; https://doi.org/10.3390/separations6010016 - 19 Mar 2019
Cited by 15 | Viewed by 6162
Abstract
A method involving the collection and determination of organic and inorganic gunshot residues on hands using on-line in-tube solid-phase microextraction (IT-SPME) coupled to miniaturized capillary liquid chromatography with diode array detection (CapLC-DAD) and scanning electron microscopy coupled to energy dispersion X-ray (SEM-EDX), respectively, [...] Read more.
A method involving the collection and determination of organic and inorganic gunshot residues on hands using on-line in-tube solid-phase microextraction (IT-SPME) coupled to miniaturized capillary liquid chromatography with diode array detection (CapLC-DAD) and scanning electron microscopy coupled to energy dispersion X-ray (SEM-EDX), respectively, for quantifying both residues was developed. The best extraction efficiency for diphenylamine (DPA) as the main target among organic residues was achieved by using a dry cotton swab followed by vortex-assisted extraction with water, which permits preservation of inorganic residues. Factors such as the nature and length of the IT-SPME extractive phase and volume of the sample processed were investigated and optimized to achieve high sensitivity: 90 cm of TRB-35 (35% diphenyl, 65% polydimethylsiloxane) capillary column and 1.8 mL of the processed sample were selected for the IT-SPME. Satisfactory limit of detection of the method for analysis of DPA deposited on shooters’ hands (0.3 ng) and precision (intra-day relative standard deviation, 9%) were obtained. The utility of the described approach was tested by analyzing several samples of shooters’ hands. Diphenylamine was found in 81% of the samples analyzed. Inorganic gunshot residues analyzed by SEM-EDX were also studied in cotton swab and lift tape kit samplers. Optical microscopy was used to see the inorganic gunshot residues in the cotton swab samplers. The lift tape kits provided lesser sensitivity for DPA than dry cotton swabs—around fourteen times. The possibility of environmental and occupational sources could be eliminated when DPA was found together with inorganic residues. Then, the presence of inorganic and organic residues in a given sample could be used as evidence in judicial proceedings in the forensic field. Full article
(This article belongs to the Special Issue Five Years of Separations: Feature Paper 2018)
Show Figures

Figure 1

12 pages, 7452 KiB  
Article
Exploring New Extractive Phases for In-Tube Solid Phase Microextraction Coupled to Miniaturized Liquid Chromatography
by Pascual Serra-Mora, Paola García-Narbona, Jorge Verdú-Andrés, Rosa Herráez-Hernández and Pilar Campíns-Falcó
Separations 2019, 6(1), 12; https://doi.org/10.3390/separations6010012 - 25 Feb 2019
Cited by 11 | Viewed by 3430
Abstract
In-tube solid-phase microextraction (IT-SPME) coupled on-line to miniaturized liquid chromatography (LC) has emerged as a powerful tool to address a variety of analytical problems. However, in order to expand its applicability, the development of new sorbents that enhance the efficiency and specificity of [...] Read more.
In-tube solid-phase microextraction (IT-SPME) coupled on-line to miniaturized liquid chromatography (LC) has emerged as a powerful tool to address a variety of analytical problems. However, in order to expand its applicability, the development of new sorbents that enhance the efficiency and specificity of the extraction is highly desirable. In this respect, the employment of capillary columns coated with sorbents functionalized with nanoparticles (NPs) replacing the loop of the injection valve (in-valve IT-SPME) is one of the most attractive options. In this work, polymers of tetraethyl orthosilicate (TEOS) and trimethoxyethylsilane (MTEOS) modified with SiO2 and TiO2 NPs have been synthetized and used for the extraction of a variety of water pollutants, using both Capillary-LC and Nano-LC. Compounds with different chemical structures and polarities such as the artificial sweetener saccharine, the polycyclic aromatic hydrocarbons (PAHs) naphthalene and fluoranthene, and some phenylurea and organophosphorous herbicides have been used as target analytes. The extraction efficiencies found with the synthetized capillaries have been compared to those obtained with commercially available capillaries coated with polydiphenyl-polydimethylsiloxane (PDMS), nitroterephthalic acid modified polyetilenglicol (FFAP), and polystyrene-divinylbenzene (PS-DVB) phases. The results obtained in this preliminary study showed that, although PS-DVB phase has the strongest affinity for compounds with two or more aromatic rings, the extraction with TEOS-MTEOS coatings modified with NPs is the best option for a majority of the tested compounds. Examples of application are given. Full article
(This article belongs to the Special Issue Advances in Solid-Phase Microextraction)
Show Figures

Figure 1

12 pages, 2389 KiB  
Article
Analysis of Contact Traces of Cannabis by In-Tube Solid-Phase Microextraction Coupled to Nanoliquid Chromatography
by Neus Jornet-Martínez, Adrián Ortega-Sierra, Jorge Verdú-Andrés, Rosa Herráez-Hernández and Pilar Campíns-Falcó
Molecules 2018, 23(9), 2359; https://doi.org/10.3390/molecules23092359 - 15 Sep 2018
Cited by 31 | Viewed by 5047
Abstract
Because of its inherent qualities, in-tube solid-phase microextraction (IT-SPME) coupled on-line to nanoliquid chromatography (nanoLC) can be a very powerful tool to address the new challenges of analytical laboratories such as the analysis of traces of complex samples. This is the case of [...] Read more.
Because of its inherent qualities, in-tube solid-phase microextraction (IT-SPME) coupled on-line to nanoliquid chromatography (nanoLC) can be a very powerful tool to address the new challenges of analytical laboratories such as the analysis of traces of complex samples. This is the case of the detection of contact traces of drugs, especially cannabis. The main difficulties encountered in the analysis of traces of cannabis plants on surfaces are the low amount of sample available (typically < 1 mg), the complexity of the matrix, and the low percentages of cannabinoic compounds in the samples. In this work, a procedure is described for the detection of residues of cannabis on different surfaces based on the responses obtained by IT-SPME coupled to nanoLC with UV diode array detection (DAD) for the cannabinoids Δ9-tetrahydrocannabinol (THC), cannabidiol (CBD), and cannabinol (CBN); the proposed conditions can also be applied for quantitative purposes through the measurement of the percentage of THC, the most abundant cannabinoid in plants. The method is based on collecting the suspected drug samples with cotton swabs, followed by the extraction of the target compounds by ultrasound assisted extraction. The extracts are then separated and processed by IT-SPME-nanoLC. The proposed approach has been applied to the detection of traces of cannabis in different kind of items (plastic bags, office paper, aluminum foil, cotton cloths, and hand skin). Sample amounts as low as 0.08 mg have been collected and analysed for THC. The selectivity and effect of the storage conditions on the levels of THC have also been evaluated. The percentages of THC in the samples typically ranged from 0.6% to 2.8%, which means that amounts of this compound as low as 1–2 µg were adequately detected and quantified. For the first time, the reliability of IT-SPME-nanoLC for the analysis of complex matrices such as cannabis plant extracts has been demonstrated. Full article
(This article belongs to the Special Issue Solid-Phase Microextraction)
Show Figures

Figure 1

12 pages, 3145 KiB  
Article
Improving the On-Line Extraction of Polar Compounds by IT-SPME with Silica Nanoparticles Modified Phases
by Pascual Serra-Mora, Carlos E. Rodríguez-Palma, Jorge Verdú-Andrés, Rosa Herráez-Hernández and Pilar Campíns-Falcó
Separations 2018, 5(1), 10; https://doi.org/10.3390/separations5010010 - 1 Feb 2018
Cited by 16 | Viewed by 3843
Abstract
In the present work the extraction efficiency of in-tube solid-phase microextraction (IT-SPME) for polar herbicides has been evaluated using extractive capillaries coated with different polymeric sorbents. For this purpose, aqueous solutions of herbicides with a wide range of polarities, including some highly polar [...] Read more.
In the present work the extraction efficiency of in-tube solid-phase microextraction (IT-SPME) for polar herbicides has been evaluated using extractive capillaries coated with different polymeric sorbents. For this purpose, aqueous solutions of herbicides with a wide range of polarities, including some highly polar compounds (log Kow < 1), have been directly processed by IT-SPME coupled on-line to capillary liquid chromatography with UV-diode array detection. For extraction, commercially available capillary columns coated with polydimethylsiloxane (PDMS) and polyetilenglicol (PEG)-based phases have been used, and the results have been compared with those obtained with a synthesized tetraethyl orthosilicate (TEOS)-trimethoxyethylsilane (MTEOS) polymer, as well as the same polymer reinforced with silica nanoparticles (SiO2 NPs). The SiO2 NPs functionalized TEOS-MTEOS coating provided the best results for most herbicides, especially for the most polar compounds. On the basis of the results obtained, conditions for the quantification of the herbicides tested are described using a SiO2 NPs reinforced TEOS-MTEOS coated capillary. The proposed method provided satisfactory linearity up to concentrations of 200 μg/L. The precision was also suitable, with relative standard deviations (RSDs) values ≤9% (n = 3), and the limits of detection (LODs) were within the 0.5–7.5 µg/L range. The method has been applied to different water samples and the extract obtained from an agricultural soil. Full article
Show Figures

Figure 1

14 pages, 2013 KiB  
Article
Application of Carbon Nanotubes Modified Coatings for the Determination of Amphetamines by In-Tube Solid-Phase Microextraction and Capillary Liquid Chromatography
by Ana Isabel Argente-García, Yolanda Moliner-Martínez, Esther López-García, Pilar Campíns-Falcó and Rosa Herráez-Hernández
Separations 2016, 3(1), 7; https://doi.org/10.3390/chromatography3010007 - 1 Mar 2016
Cited by 26 | Viewed by 4903
Abstract
In this study, polydimethylsiloxane (PDMS)-coated capillary columns (TRB-5 and TRB-35), both unmodified and functionalized with single-wall carbon nanotubes (SWCNTs) or multiwall carbon nanotubes (MWCNTs), have been tested and compared for the extraction of amphetamine (AMP), methamphetamine (MET) and ephedrine (EPE) by in-tube solid-phase [...] Read more.
In this study, polydimethylsiloxane (PDMS)-coated capillary columns (TRB-5 and TRB-35), both unmodified and functionalized with single-wall carbon nanotubes (SWCNTs) or multiwall carbon nanotubes (MWCNTs), have been tested and compared for the extraction of amphetamine (AMP), methamphetamine (MET) and ephedrine (EPE) by in-tube solid-phase microextraction (IT-SPME). Prior to their extraction, the analytes were derivatized with the fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC). For separation and detection capillary chromatography with fluorimetric detection has been used. The presence of carbon nanotubes in the extractive coatings enhanced the extraction efficiencies and also significantly improved the chromatographic profiles, thus resulting in a reliable option for the analysis of these drugs. As an example of application, a new method is proposed for the analysis of the tested amphetamines in oral fluid using a TRB-35 capillary column functionalized with MWCNTs. The proposed conditions provided suitable selectivity and reproducibility (CV ≤ 6%, n = 3) at low µg/mL levels, and limits of detection of 0.5–0.8 µg/mL. Full article
(This article belongs to the Special Issue Trends in Microextraction Techniques for Sample Preparation)
Show Figures

Graphical abstract

14 pages, 1820 KiB  
Article
Evaluation of Carbon Nanotubes Functionalized Polydimethylsiloxane Based Coatings for In-Tube Solid Phase Microextraction Coupled to Capillary Liquid Chromatography
by Neus Jornet-Martínez, Pascual Serra-Mora, Yolanda Moliner-Martínez, Rosa Herráez-Hernández and Pilar Campíns-Falcó
Chromatography 2015, 2(3), 515-528; https://doi.org/10.3390/chromatography2030515 - 10 Aug 2015
Cited by 11 | Viewed by 6622
Abstract
In the present work, the performance of carbon nanotubes (c-CNTs) functionalized polydimethylsiloxane (PDMS) based coatings as extractive phases for in-tube solid phase microextraction (IT-SPME) coupled to Capillary LC (CapLC) has been evaluated. Carboxylic-single walled carbon nanotubes (c-SWNTs) and carboxylic-multi walled carbon nanotubes (c-MWNTs) [...] Read more.
In the present work, the performance of carbon nanotubes (c-CNTs) functionalized polydimethylsiloxane (PDMS) based coatings as extractive phases for in-tube solid phase microextraction (IT-SPME) coupled to Capillary LC (CapLC) has been evaluated. Carboxylic-single walled carbon nanotubes (c-SWNTs) and carboxylic-multi walled carbon nanotubes (c-MWNTs) have been immobilized on the activated surface of PDMS capillary columns. The effect of different percentages of diphenyl groups in the PDMS extractive phase has also been evaluated. The extraction capability of the capillary columns has been tested for different organic pollutants, nitrogen heterocyclic compounds and polycyclic aromatic compounds (PAHs). The results indicated that the use of the c-CNTs-PDMS capillary columns improve pyriproxyfen and mainly PAH extraction. Triazines were better extracted by unmodified TRB-35 and modified c-CNTs-PDMSTRB-5. The results showed that the extraction capability of the c-CNT capillary columns depends not only on the polarity of the analytes (as it occurs with PDMS columns) but also on the interactions that the analytes can establish with the immobilized c-CNTs on the PDMS columns. The extraction efficiency has been evaluated on the basis of the preconcentration rate that can be achieved, and, in this sense, the best c-CNTs-PDMS capillary column for each group of compounds can be proposed. Full article
(This article belongs to the Special Issue Solid Phase Micro-Extraction)
Show Figures

Figure 1

Back to TopTop