Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

Search Results (5)

Search Parameters:
Keywords = harmonic scalpel

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
11 pages, 547 KB  
Article
Total Thyroidectomy with Harmonic Scalpel Combined with Gelatin Thrombin Hemostatic: A Focus on the Elderly Population—A Multicentric Study
by Simona Parisi, Claudio Gambardella, Roberto Ruggiero, Giovanni Docimo, Vincenzo Marotta, Adelmo Gubitosi, Federico Maria Mongardini, Valerio D’Orazi, Francesca Fisone, Luigi Brusciano, Salvatore Tolone, Ludovico Docimo and Francesco Saverio Lucido
Medicina 2025, 61(3), 496; https://doi.org/10.3390/medicina61030496 - 13 Mar 2025
Viewed by 963
Abstract
Background and Objectives: With the increasing life expectancy, the frequency of total thyroidectomies in elderly patients has risen, raising concerns regarding hemorrhage and recurrent laryngeal nerve palsy compared to the general population. Therefore, considering the frequent alteration of the coagulation status in [...] Read more.
Background and Objectives: With the increasing life expectancy, the frequency of total thyroidectomies in elderly patients has risen, raising concerns regarding hemorrhage and recurrent laryngeal nerve palsy compared to the general population. Therefore, considering the frequent alteration of the coagulation status in such patients, innovative methods able to reach an accurate hemostasis appear highly desirable. This retrospective multicentric study aimed to compare the postoperative outcomes of patients treated with conventional hemostasis with patients treated with the Harmonic Scalpel (HS) and gelatin–thrombin matrix (Floseal). Materials and Methods: Patients undergoing total thyroidectomy were retrospectively enrolled and categorized into two groups: Group A patients underwent surgery with the Harmonic Scalpel and Floseal, while Group B underwent traditional hemostasis surgery with ligations and monopolar electrocautery. The primary endpoint was the drain output after 24 and 48 h and the presence of significant blood loss. Secondary endpoints included the presence of seroma, wound infection, hematoma, laryngeal nerve palsy, surgery duration, and onset of post-surgical hypocalcemia. Results: From January 2014 to January 2024, 870 individuals participated in the study. Group A (gelatin–thrombin and HS) comprised 502 patients, while Group B (Standard Hemostasis—control group) comprised 368 patients. The 24 h drain output was 52 ± 25 mL in Group A vs. 113 ± 27 mL in Group B, p = 0.003, while the 48 h drain output was 95 ± 29 mL in Group A and 113 ± 27 mL in Group B (p = 0.002). Significant blood loss occurred in eight patients (2.2%) of Group B vs. three cases (0.6%) in Group A (p = 0.039). Also, neck hematoma (p = 0.012), seroma (p = 0.005), and reoperation (p = 0.052) values were significantly lower in Group A. Conclusions: Surgery aided with HS, and gelatin–thrombin was associated with lower major and minor complications compared to the conventional approach, guarantying reduced operative time, ensuring hemostasis, and preserving parathyroid glands, even in elderly patients. Full article
(This article belongs to the Section Surgery)
Show Figures

Figure 1

13 pages, 1585 KB  
Article
Is Using the Harmonic Scalpel Better than Conventional Hemostasis in Neck Dissection? A Meta-Analysis
by Ishaque Hameed, Mohammad Omer Khan, Syed Abdus Samad, Samar Mahmood, Omer Mustafa Siddiqui, Indallah Hameed, Muhammad Nashit, Ayman Iqbal, Shayan Marsia and Al Haitham Al Shetawi
Craniomaxillofac. Trauma Reconstr. 2024, 17(1), 74-86; https://doi.org/10.1177/19433875231170924 - 15 Apr 2023
Viewed by 217
Abstract
Study Design: Systematic review and meta-analysis. Objective: The clinical decision to pursue harmonic scalpel (HS) method vs conventional hemostasis to treat head and neck cancers has been arguably predicated on the clinical outcomes observed. This study aims to evaluate the surgical outcomes of [...] Read more.
Study Design: Systematic review and meta-analysis. Objective: The clinical decision to pursue harmonic scalpel (HS) method vs conventional hemostasis to treat head and neck cancers has been arguably predicated on the clinical outcomes observed. This study aims to evaluate the surgical outcomes of neck dissection between both techniques and perform an updated meta-analysis using the available literature. Methods: We searched PubMed, Scopus, and Cochrane Library through 31 December 2021, according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Outcome metrics included operative time and intraoperative blood loss. Secondary outcomes consisted of length of hospital stay, length of drain stay, total drain output, and postoperative complications. A meta-analysis was conducted using Review Manager Version 5.3 (RevMan) software employing the Random Effects Model. Results: We identified 114 articles, out of which 10 randomized control trials (RCTs) analyzing a combined total of 558 patients met the inclusion criteria after title and full-text screening. Meta-analysis shows the group treated with HS had a significantly shorter operative time. [MD = −23.21, 95% CI (−34.30, −12.12) p value < 0.0001 I2 = 92%] but an insignificant lesser intraoperative blood loss [MD = −61.53, 95% CI (−88.61, −34.45) p < 0.00001 I2 = 79%]. Conclusions: This study confirms that that HS use in neck dissection yields a reduced operative time and intra operative blood loss relative to conventional hemostasis. Furthermore, our paper shows no superiority of HS method over conventional hemostasis where length of hospital stays, length of drain stays, and postoperative complications are concerned. Future RCTs with high-level evidence may further elucidate the relative effectiveness of HS method over conventional hemostasis in treating head and neck cancers. Full article
Show Figures

Figure 1

13 pages, 1835 KB  
Systematic Review
Energy Devices for Clipless–Sutureless Laparoscopic Appendectomy: A Systematic Review and Meta-Analysis on Utility and Safety
by Apoorv Singh, Sachit Anand, Niklas Pakkasjärvi, Ajay Verma and Minu Bajpai
Medicina 2022, 58(11), 1535; https://doi.org/10.3390/medicina58111535 - 27 Oct 2022
Cited by 2 | Viewed by 3021
Abstract
Background and Objectives: While laparoscopic appendectomy is standardized, techniques for appendiceal stump closure and mesoappendix division remain variable. Novel vessel sealing techniques are increasingly utilized ubiquitously. We sought to systematically summarize all relevant data and to define the current evidence on the [...] Read more.
Background and Objectives: While laparoscopic appendectomy is standardized, techniques for appendiceal stump closure and mesoappendix division remain variable. Novel vessel sealing techniques are increasingly utilized ubiquitously. We sought to systematically summarize all relevant data and to define the current evidence on the safety and utility of energy devices for clipless–sutureless laparoscopic appendectomy in this systematic review and meta-analysis. Materials and Methods: This review was conducted following the PRISMA guidelines. PubMed, Embase, Scopus, and Web of Science were systematically searched. Inclusion criteria included studies with laparoscopic appendectomy for appendicitis. The intervention included patients undergoing division of mesoappendix and/or securing of the appendicular base using diathermy (Monopolar or Bipolar or LigaSure Sealing Device) or Harmonic Scalpel (Group A) compared to patients undergoing division of mesoappendix and/or securing of the appendicular base using endoclip or Hem-o-lok or ligature (Group B). The methodological quality of the included studies was assessed using the Downs and Black scale. The outcomes of surgical site infection (SSI) or intra-abdominal collection, postoperative ileus, average operative duration, and length of hospital stay (LHS) were compared. Results: Six comparative studies were included; three were retrospective, two were prospective, and one was ambispective. Meta-analysis revealed a shorter operative duration in Group A with respect to appendicular base ligation (MD −12.34, 95% CI −16.57 to −8.11, p < 0.00001) and mesoappendix division (MD −8.06, 95% CI −14.03 to −2.09, p = 0.008). The pooled risk ratios showed no difference in SSI between groups. Additionally, no difference was observed in LHS. The risk of postoperative ileus was higher in group B regarding mesoappendix division (RR 0.56, 95% CI 0.34 to 0.93, p = 0.02), but no difference was found concerning appendicular base ligation. The included studies showed a moderate-to-high risk of bias. Conclusions: Clipless–sutureless laparoscopic appendectomy is safe and fast. Postoperative ileus seems less common with energy devices for mesoappendix division. However, the studies included have a moderate-to-high risk of bias. Further studies addressing the individual devices with surgeons of similar levels are needed. Full article
(This article belongs to the Section Surgery)
Show Figures

Figure 1

18 pages, 6616 KB  
Article
Swine Small Intestine Sealing Performed by Different Vessel Sealing Devices: Ex-Vivo Test
by Luca Lacitignola, Annarita Imperante, Rodrigo Trisciuzzi, Nicola Zizzo, Alberto Maria Crovace and Francesco Staffieri
Vet. Sci. 2021, 8(2), 34; https://doi.org/10.3390/vetsci8020034 - 22 Feb 2021
Cited by 4 | Viewed by 5252
Abstract
This study aimed to evaluate the sealing quality of swine small intestine using different laparoscopic radiofrequency vessel sealing devices (two 5 mm: RFVS-1 and -2; one 10 mm: RFVS-3) and a harmonic scalpel (HS) compared to golden standard closure technique. The study was [...] Read more.
This study aimed to evaluate the sealing quality of swine small intestine using different laparoscopic radiofrequency vessel sealing devices (two 5 mm: RFVS-1 and -2; one 10 mm: RFVS-3) and a harmonic scalpel (HS) compared to golden standard closure technique. The study was divided into two arms. In study arm 1: n = 50 swine intestinal loops (10 per group) were transected with each instrument and the loops in which the devices provided complete sealing, at the gross inspection, were tested for maximum burst pressure (BP) and histological evaluation and compared to an automatic linear stapler. After the BP tests, the devices that achieved significantly lower BP values were excluded from the second arm. The RFVS-1 and -3 provided statistically significant results and were used in study arm 2, to obtain full-thickness biopsies along the antimesenteric border of the loop and were compared with hand-sewn intestinal closure (n = 30; 10 per group). The biopsies were histologically evaluated for thermal injury and diagnostic features, and intestinal loops tested for BP. RFVS-3 achieved comparable results (69.78 ± 4.23 mmHg, interquartile range (IQR) 5.8) to stapler closing technique (71.09 ± 4.22 mmHg, IQR 4.38; p > 0.05), while the RFVS-1 resulted in significantly (p < 0.05) lower BP (45.28 ± 15.23 mmHg, IQR 24.95) but over the physiological range, conversely to RFVS-2 (20.16 ± 7.19 mmHg, IQR 12.02) and HS (not measurable). RFVS-3 resulted not significantly different (p > 0.05) (45.09 ± 8.75 mmHg, IQR 10.48) than Suture (35.71 ± 17.51 mmHg, IQR 23.77); RFVS-1 resulted significantly lower values (23.96 ± 10.63 mmHg, IQR 9.62; p < 0.05). All biopsies were judged diagnostic. Data confirmed that RFVS-1 and -3 devices provided suitable intestinal sealing, with BP pressures over the physiological range. Conversely, the HS and RFVS-2 should not be considered for intestinal sealing. RFVS devices could be employed to obtain small intestine stump closure or full-thickness biopsies. However, further studies should be performed in live animals to assess the role of the healing process. Full article
Show Figures

Figure 1

4 pages, 645 KB  
Article
Retroperitoneal Hand-Assisted Laparoscopic Nephrectomy and Partial Nephrectomy
by Nosratollah Nezakatzgoo, Janet L. Colli, Matthew Mutter, Sheg Aranmolate and Robert Wake
Surg. Tech. Dev. 2013, 3(1), e3; https://doi.org/10.4081/std.2013.e3 - 7 Nov 2013
Cited by 1
Abstract
The purpose of the present paper is to describe our technique and experience with retroperitoneal hand-assisted laparoscopic (HAL) nephrectomies as an alternative to the transperitoneal approach. Eight retroperitoneal HAL nephrectomies and one partial nephrectomy were performed. Several excisional techniques were employed incorporating the [...] Read more.
The purpose of the present paper is to describe our technique and experience with retroperitoneal hand-assisted laparoscopic (HAL) nephrectomies as an alternative to the transperitoneal approach. Eight retroperitoneal HAL nephrectomies and one partial nephrectomy were performed. Several excisional techniques were employed incorporating the Harmonic scalpel or Ligasure device. Hemostatic agents were used to cover the renal defect. Surgical bolsters were sutured to the renal capsule with pleget reinforcements to aid in hemostasis. The average operative time was 210 min and estimated blood loss 110 mL. Mean change in hematocrit was 3 units and creatinine was 1 point. No patient required a transfusion. There were no major complications, with a mean follow-up of fourteen months. On average, patients resumed oral intake in 2 days, and were discharged in 3 days. Pathological examination revealed that two lesions were benign and seven malignant. Tumor diameter averaged 3 cm. There were no positive surgical margins. In conclusion, we have demonstrated the feasibility of retroperitoneal laparoscopic hand-assisted nephrectomy and partial nephrectomy surgery for solid renal masses. Full article
Back to TopTop