Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (231)

Search Parameters:
Keywords = cooling compressed air

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
24 pages, 2458 KiB  
Review
Vapor Compression Refrigeration System for Aircrafts: Current Status, Large-Temperature-Range Challenges and Emerging Auto-Cascade Refrigeration Technologies
by Hainan Zhang, Qinghao Wu, Shuo Feng, Sujun Dong and Zanjun Gao
Aerospace 2025, 12(8), 681; https://doi.org/10.3390/aerospace12080681 - 30 Jul 2025
Viewed by 259
Abstract
Modern aircraft increasingly utilizes highly integrated electronic equipment, driving continuously increasing heat dissipation demands. Vapor compression refrigeration systems demonstrate stronger alignment with future aircraft thermal management trends, leveraging their superior volumetric cooling capacity, high energy efficiency, and independence from engine bleed air. This [...] Read more.
Modern aircraft increasingly utilizes highly integrated electronic equipment, driving continuously increasing heat dissipation demands. Vapor compression refrigeration systems demonstrate stronger alignment with future aircraft thermal management trends, leveraging their superior volumetric cooling capacity, high energy efficiency, and independence from engine bleed air. This paper reviews global research progress on aircraft vapor compression refrigeration systems, covering performance optimization, dynamic characteristics, control strategies, fault detection, and international development histories and typical applications. Analysis identifies emerging challenges under large-temperature-range cooling requirements, with comparative assessment establishing zeotropic mixture auto-cascade vapor compression refrigeration systems as the optimal forward-looking solution. Finally, recognizing current research gaps, we propose future research directions for onboard auto-cascade vapor compression refrigeration systems: optimizing refrigerant mixtures for flight conditions, achieving efficient gas-liquid separation during variable overloads and attitude conditions, and developing model predictive control with intelligent optimization to ensure reliability. Full article
(This article belongs to the Special Issue Aerospace Human–Machine and Environmental Control Engineering)
Show Figures

Figure 1

7 pages, 481 KiB  
Proceeding Paper
Working Fluid Selection for Biogas-Powered Organic Rankine Cycle-Vapor Compression Cycle
by Muhammad Talha, Nawaf Mehmood Malik, Muhammad Tauseef Nasir, Waqas Khalid, Muhammad Safdar and Khawaja Fahad Iqbal
Mater. Proc. 2025, 23(1), 1; https://doi.org/10.3390/materproc2025023001 - 25 Jul 2025
Viewed by 88
Abstract
The worldwide need for energy as well as environmental challenges have promoted the creation of sustainable power solutions. The combination of different working fluids is used for an organic Rankine cycle-powered vapor compression cycle (ORC-VCC) to deliver cooling applications. The selection of an [...] Read more.
The worldwide need for energy as well as environmental challenges have promoted the creation of sustainable power solutions. The combination of different working fluids is used for an organic Rankine cycle-powered vapor compression cycle (ORC-VCC) to deliver cooling applications. The selection of an appropriate working fluid significantly impacts system performance, efficiency, and environmental impact. The research evaluates possible working fluids to optimize the ORC-VCC system. Firstly, Artificial Neural Network (ANN)-derived models are used for exergy destruction ( E d t o t ) and heat exchanger total heat transfer capacity ( U A t o t ). Later on, multi-objective optimization was carried out using the acquired models for E d t o t and U A t o t using the Genetic Algorithm (GA) followed by the Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS). The optimization results showcase Decane ORC-R600a VCC as the best candidate for the ORC-VCC system; the values of E d t o t and U A t o t were found to be 24.50 kW and 6.71 kW/K, respectively. The research data show how viable it is to implement biogas-driven ORC-VCC systems when providing air conditioning capabilities. Full article
Show Figures

Figure 1

32 pages, 3675 KiB  
Article
Gibbs Quantum Fields Computed by Action Mechanics Recycle Emissions Absorbed by Greenhouse Gases, Optimising the Elevation of the Troposphere and Surface Temperature Using the Virial Theorem
by Ivan R. Kennedy, Migdat Hodzic and Angus N. Crossan
Thermo 2025, 5(3), 25; https://doi.org/10.3390/thermo5030025 - 22 Jul 2025
Viewed by 227
Abstract
Atmospheric climate science lacks the capacity to integrate thermodynamics with the gravitational potential of air in a classical quantum theory. To what extent can we identify Carnot’s ideal heat engine cycle in reversible isothermal and isentropic phases between dual temperatures partitioning heat flow [...] Read more.
Atmospheric climate science lacks the capacity to integrate thermodynamics with the gravitational potential of air in a classical quantum theory. To what extent can we identify Carnot’s ideal heat engine cycle in reversible isothermal and isentropic phases between dual temperatures partitioning heat flow with coupled work processes in the atmosphere? Using statistical action mechanics to describe Carnot’s cycle, the maximum rate of work possible can be integrated for the working gases as equal to variations in the absolute Gibbs energy, estimated as sustaining field quanta consistent with Carnot’s definition of heat as caloric. His treatise of 1824 even gave equations expressing work potential as a function of differences in temperature and the logarithm of the change in density and volume. Second, Carnot’s mechanical principle of cooling caused by gas dilation or warming by compression can be applied to tropospheric heat–work cycles in anticyclones and cyclones. Third, the virial theorem of Lagrange and Clausius based on least action predicts a more accurate temperature gradient with altitude near 6.5–6.9 °C per km, requiring that the Gibbs rotational quantum energies of gas molecules exchange reversibly with gravitational potential. This predicts a diminished role for the radiative transfer of energy from the atmosphere to the surface, in contrast to the Trenberth global radiative budget of ≈330 watts per square metre as downwelling radiation. The spectral absorptivity of greenhouse gas for surface radiation into the troposphere enables thermal recycling, sustaining air masses in Lagrangian action. This obviates the current paradigm of cooling with altitude by adiabatic expansion. The virial-action theorem must also control non-reversible heat–work Carnot cycles, with turbulent friction raising the surface temperature. Dissipative surface warming raises the surface pressure by heating, sustaining the weight of the atmosphere to varying altitudes according to latitude and seasonal angles of insolation. New predictions for experimental testing are now emerging from this virial-action hypothesis for climate, linking vortical energy potential with convective and turbulent exchanges of work and heat, proposed as the efficient cause setting the thermal temperature of surface materials. Full article
Show Figures

Figure 1

26 pages, 4303 KiB  
Article
Thermal Degradation and Microstructural Evolution of Geopolymer-Based UHPC with Silica Fume and Quartz Powder
by Raghda A. Elhefny, Mohamed Abdellatief, Walid E. Elemam and Ahmed M. Tahwia
Infrastructures 2025, 10(8), 192; https://doi.org/10.3390/infrastructures10080192 - 22 Jul 2025
Viewed by 213
Abstract
The durability and fire resilience of concrete structures are increasingly critical in modern construction, particularly under elevated-temperature exposure. With this context, the current study explores the thermal and microstructural characteristics of geopolymer-based ultra-high-performance concrete (G-UHPC) incorporating quartz powder (QP) and silica fume (SF) [...] Read more.
The durability and fire resilience of concrete structures are increasingly critical in modern construction, particularly under elevated-temperature exposure. With this context, the current study explores the thermal and microstructural characteristics of geopolymer-based ultra-high-performance concrete (G-UHPC) incorporating quartz powder (QP) and silica fume (SF) after exposure to elevated temperatures. SF was used at 15% and 30% to partially replace the precursor material, while QP was used at 25%, 30%, and 35% as a partial replacement for fine sand. The prepared specimens were exposed to 200 °C, 400 °C, and 800 °C, followed by air cooling. Mechanical strength tests were conducted to evaluate compressive and flexural strengths, as well as failure patterns. Microstructural changes due to thermal exposure were assessed using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). Among the prepared mixtures, the 30SF35QP mixture exhibited the highest compressive strength (156.0 MPa), followed by the 15SF35QP mix (146.83 MPa). The experimental results demonstrated that G-UHPC underwent varying levels of thermal degradation across the 200–800 °C range yet displayed excellent resistance to thermal spalling. At 200 °C, compressive strength increased due to enhanced geopolymerization, with the control mix showing a 29.8% increase. However, significant strength reductions were observed at 800 °C, where the control mix retained only 30.8% (32.0 MPa) and the 30SF25QP mixture retained 28% (38.0 MPa) of their original strengths. Despite increased porosity and cracking at 800 °C, the 30SF35QP mixture exhibited superior strength retention due to its denser matrix and reduced voids. The EDS results confirmed improved gel stability in the 30% SF mixtures, as evidenced by higher silicon content. These findings suggest that optimizing SF and QP content significantly enhances the fire resistance and structural integrity of G-UHPC, providing practical insights for the design of sustainable, high-performance concrete structures in fire-prone environments. Full article
Show Figures

Figure 1

42 pages, 4568 KiB  
Review
Comprehensive Review on Evaporative Cooling and Desiccant Dehumidification Technologies for Agricultural Greenhouses
by Fakhar Abbas, Muhammad Sultan, Muhammad Wakil Shahzad, Muhammad Farooq, Hafiz M. U. Raza, Muhammad Hamid Mahmood, Uzair Sajjad and Zhaoli Zhang
AgriEngineering 2025, 7(7), 222; https://doi.org/10.3390/agriengineering7070222 - 8 Jul 2025
Viewed by 1341
Abstract
Greenhouses are crucial for maintaining an ideal temperature and humidity level for plant growth; however, attaining ideal levels remains a challenge. Energy-efficient and sustainable alternatives are needed because traditional temperature/humidity control practices and vapor compression air conditioning systems depend on climate conditions and [...] Read more.
Greenhouses are crucial for maintaining an ideal temperature and humidity level for plant growth; however, attaining ideal levels remains a challenge. Energy-efficient and sustainable alternatives are needed because traditional temperature/humidity control practices and vapor compression air conditioning systems depend on climate conditions and harmful refrigerants. Advanced alternative technologies like evaporative cooling and desiccant dehumidification have emerged that maintain the ideal greenhouse temperature and humidity while using the least amount of energy. This study reviews direct evaporative cooling, indirect evaporative cooling, and Maisotsenko-cycle evaporative cooling (MEC) systems and solid and liquid desiccant dehumidification systems. In addition, integrated desiccant and evaporative cooling systems and hybrid systems are reviewed in this study. The results show that the MEC system effectively reduces the ambient temperature up to the ideal range while maintaining the humidity ratio, and both dehumidification systems effectively reduce the humidity level and improve evaporative cooling efficiency. The integrated systems and hybrid systems have the ability to increase energy efficiency and controlled climatic stability in greenhouses. Regular maintenance, initial system cost, economic feasibility, and system scalability are significant challenges to implement these advanced temperature and humidity control systems for greenhouses. These findings will assist agricultural practitioners, engineers, and researchers in seeking alternate efficient cooling methods for greenhouse applications. Future research directions are suggested to manufacture high-efficiency, low-energy consumption, and efficient greenhouse temperature control systems while considering the present challenges. Full article
Show Figures

Figure 1

26 pages, 20735 KiB  
Article
The Study of the Effect of Blade Sharpening Conditions on the Lifetime of Planar Knives During Industrial Flatfish Skinning Operations
by Paweł Sutowski, Bartosz Zieliński and Krzysztof Nadolny
Materials 2025, 18(13), 3191; https://doi.org/10.3390/ma18133191 - 6 Jul 2025
Viewed by 380
Abstract
Users of technical blades expect new generations of tools to feature reduced power requirements for process and maximized tool life. The second aspect is reflected in the reduction in costs associated with the purchase of tools and in the reduction in process line [...] Read more.
Users of technical blades expect new generations of tools to feature reduced power requirements for process and maximized tool life. The second aspect is reflected in the reduction in costs associated with the purchase of tools and in the reduction in process line downtime due to tool replacement. Meeting these demands is particularly challenging in cutting operations involving heterogeneous materials, especially when the processed raw material contains inclusions and impurities significantly harder than the material itself. This situation occurs, among others, during flatfish skinning operations analyzed in this paper, a common process in the fish processing industry. These fish, due to their natural living environment and behavior, contain a significant proportion of hard inclusions and impurities (shell fragments, sand grains) embedded in their skin. Contact between the tool and hard inclusions causes deformation, wrapping, crushing, and even chipping of the cutting edge of planar knives, resulting in non-uniform blade wear, which manifests as areas of uncut skin on the fish fillet. This necessitates frequent tool changes, resulting in higher tooling costs and longer operating times. This study provides a unique opportunity to review the results of in-service pre-implementation tests of planar knives in the skinning operation conducted under industrial conditions. The main objective was to verify positive laboratory research results regarding the extension of technical blade tool life through optimization of sharpening conditions during grinding. Durability test results are presented for the skinning process of fillets from plaice (Pleuronectes platessa) and flounder (Platichthys flesus). The study also examined the effect of varying cooling and lubrication conditions in the grinding zone on the tool life of technical planar blades. Sharpening knives under flood cooling conditions and using the hybrid method (combining minimum quantity lubrication and cold compressed air) increased their service life in the plaice skinning process (Pleuronectes platessa) by 12.39% and 8.85%, respectively. The increase in effective working time of knives during flounder (Platichthys flesus) skinning was even greater, reaching 17.7% and 16.3% for the flood cooling and hybrid methods, respectively. Full article
Show Figures

Figure 1

26 pages, 2757 KiB  
Article
Comparative Life Cycle Analysis for Duct Air Conditioning Systems Based on Evaporative and Vapor Compression Technologies
by Andrzej Marcinkowski and Dmytro Levchenko
Energies 2025, 18(13), 3475; https://doi.org/10.3390/en18133475 - 1 Jul 2025
Viewed by 391
Abstract
The environmental impact of innovative indirect regenerative evaporative cooling (IREC) technology is analyzed using the life cycle assessment. This study compared typical equipment using this technology from Innovative Ideas LLC with available-on-the-market traditional vapor compression ducted air conditioning systems as the closest analogous [...] Read more.
The environmental impact of innovative indirect regenerative evaporative cooling (IREC) technology is analyzed using the life cycle assessment. This study compared typical equipment using this technology from Innovative Ideas LLC with available-on-the-market traditional vapor compression ducted air conditioning systems as the closest analogous representatives of the vapor compression technology. For comparison, units with the same cooling capacity (5 kW) were selected. The endpoint indicators demonstrated that the air conditioning systems using IREC technology had lower environmental load compared to the vapor compression system by 29–70%, depending on the scenario and damage category. This advantage resulted from the significantly higher coefficient of performance of the IREC system. The amounts of cooling energy generated and electricity consumption were determined based on temperature and relative humidity data recorded at hourly intervals in the summer seasons of 2023 and 2024. The operation turned out to be a life cycle stage with dominating environmental load. The uncertainty analysis carried out with Monte Carlo simulations indicated significant deviation, particularly for the ecosystem category. The sensitivity analysis showed that the assumed electricity mix did not significantly affect the general conclusions. Full article
Show Figures

Figure 1

22 pages, 4739 KiB  
Article
On the Use of Compressed Air and Synthetic Biodegradable Cutting Fluid to Enhance the Surface Quality of WAAM–CMT Manufactured Low-Alloy Steel Parts During Post-Processing Milling with Different Cooling–Lubrication Strategies
by Déborah de Oliveira, Marcos Vinícius Gonçalves, Guilherme Menezes Ribeiro, André Luis Silva da Costa, Luis Regueiras, Tiago Silva, Abílio de Jesus, Lucival Malcher and Maksym Ziberov
J. Manuf. Mater. Process. 2025, 9(6), 193; https://doi.org/10.3390/jmmp9060193 - 10 Jun 2025
Viewed by 540
Abstract
Additive manufacturing (AM) stands out for its variable applications in terms of material, quality, and geometry. Wire Arc Additive Manufacturing (WAAM) is remarkable for producing large parts in reduced times when compared to other AM methods. The possibility of producing a part with [...] Read more.
Additive manufacturing (AM) stands out for its variable applications in terms of material, quality, and geometry. Wire Arc Additive Manufacturing (WAAM) is remarkable for producing large parts in reduced times when compared to other AM methods. The possibility of producing a part with a near-net shape not only enhances productivity but also reduces resources usage. However, parts produced by WAAM may need post-processing by machining to achieve functional surface requirements. Therefore, it is important that machining, even if minimized, does not lead to a significant environmental impact. In this sense, this work evaluates the effect of using compressed air, dry cut, and synthetic biodegradable cutting fluid at varying nozzle positions and flow rates on the surface quality of ER70S-6 steel produced by WAAM, after milling with TiAlN-coated carbide tools. To analyze the surface roughness, parameters Ra, Rq, and Rz were measured and microscopy was used to further evaluate the surfaces. The surface hardness was also evaluated. The results showed that a flow rate of 10 L/min promotes better surface quality, which can be further improved using compressed air, leading to a surface quality 50% better when compared to dry cutting. Dry cut was not suitable for machining ER70S-6 WAAM material as it resulted in rough surface texture with an Rz = 4.02 µm. Compressed air was the best overall condition evaluated, achieving a 36% Ra reduction compared to dry cutting, the second-lowest hardness deviation at 6.51%, and improved sustainability by eliminating the need for cutting fluid. Full article
Show Figures

Figure 1

16 pages, 3942 KiB  
Article
Utilization of Coal Ash for Production of Refractory Bricks
by Saniya Kaskataevna Arinova, Svetlana Sergeevna Kvon, Vitaly Yurevich Kulikov, Aristotel Zeynullinovich Issagulov and Asem Erikovna Altynova
J. Compos. Sci. 2025, 9(6), 275; https://doi.org/10.3390/jcs9060275 - 29 May 2025
Viewed by 446
Abstract
Coal combustion generates significant volumes of ash, a technogenic by-product that poses a serious threat to regional environmental sustainability (environmental chemical contamination and air pollution). This study aims to assess the feasibility of utilizing this type of ash as a raw material component [...] Read more.
Coal combustion generates significant volumes of ash, a technogenic by-product that poses a serious threat to regional environmental sustainability (environmental chemical contamination and air pollution). This study aims to assess the feasibility of utilizing this type of ash as a raw material component in the fabrication of refractory bricks and to investigate the fundamental properties of the resulting experimental products. Ash was incorporated into the batch composition at concentrations ranging from 10% to 40% by weight, blended with clay and water, then shaped through pressing and subjected to firing at 1000 °C and 1100 °C in an air atmosphere for 2 h. After complete cooling, the samples were subjected to compressive strength testing. Samples containing 40 wt% coal ash exhibited insufficient compressive strength and were therefore excluded from subsequent investigations. For the remaining samples, apparent density, open porosity and slag resistance were determined. The microstructural characterization was performed, and the phase composition of the samples was analyzed. The results revealed that the phase composition of the experimental samples differs significantly from that of the reference sample (ShA-grade chamotte brick in accordance with GOST 390-96, currently used as lining in metallurgical furnaces across the country), exhibiting a higher mullite content and the absence of muscovite. A small amount of kaolinite was detected in the experimental samples even after a 2-h firing process. This observation may be attributed to the effect of kaolinite crystallinity on the transformation process from kaolinite to metakaolinite. The mechanical strength of the experimental samples meets the relevant standards, while slag resistance demonstrated an improvement of approximately 15%. Open porosity was found to decrease in the experimental samples. In addition, a change in the pore size distribution was observed. Notably, the proportion of pores larger than 10,000 nm was significantly reduced. These findings confirm the feasibility of incorporating coal ash as a viable raw material component in the formulation of refractory materials. Full article
Show Figures

Figure 1

23 pages, 6824 KiB  
Article
Study on the Influence of Expansion Ratio on the Effectiveness of Foam in Suppressing Forest Surface Fires
by Haiyan Wang, Junzhao Zhang, Hongbin Zhong and Lei Chen
Fire 2025, 8(5), 171; https://doi.org/10.3390/fire8050171 - 28 Apr 2025
Viewed by 661
Abstract
Firefighting foam is widely recognized for its excellent fire suppression performance. However, research on the effect of foam expansion ratio on the suppression efficiency of forest surface fires remains limited. In this study, the expansion ratio was adjusted by varying the air-to-liquid ratio [...] Read more.
Firefighting foam is widely recognized for its excellent fire suppression performance. However, research on the effect of foam expansion ratio on the suppression efficiency of forest surface fires remains limited. In this study, the expansion ratio was adjusted by varying the air-to-liquid ratio in a compressed air foam system, and laboratory-scale foam suppression experiments were conducted. Key performance indicators, including extinguishing coverage time, internal cooling rate, and resistance to reignition, were systematically measured. The effects of expansion ratio on the diffusion and penetration behavior of foam on the fuel bed surface were then investigated to understand how these characteristics influence suppression performance. The results indicate that both excessively low and high expansion ratios can weaken fire suppression effectiveness. Low-expansion foam, characterized by low viscosity and high water content, exhibits strong local penetration and cooling capabilities. However, it struggles to rapidly cover the fuel bed surface and isolate oxygen, thereby reducing the overall suppression efficiency. In contrast, high-expansion foam has greater viscosity, allowing it to spread across the fuel bed surface under pressure gradient forces and form a stable coverage layer, effectively limiting the oxygen supply required for combustion. However, its limited depth penetration and lower water content reduce internal cooling efficiency, increasing the risk of reignition. The optimal expansion ratio was determined to be 15.1. Additionally, increasing the liquid supply flow rate significantly improved suppression performance; however, this improvement plateaued when the flow rate exceeded 10 L/min. Full article
(This article belongs to the Special Issue Firefighting Approaches and Extreme Wildfires)
Show Figures

Figure 1

12 pages, 4594 KiB  
Article
Optimization of Lubrication Amount for Sewing Threads
by Adnan Mazari and Funda Buyuk Mazari
Textiles 2025, 5(2), 15; https://doi.org/10.3390/textiles5020015 - 28 Apr 2025
Viewed by 840
Abstract
Sewing needle heating is a common problem for the sewing of technical and medical textiles. The hot needle causes burnt spots on fabric, breakage of the thread, and weak seam strength. Multiple ways are used in industry to cool the needle including compressed [...] Read more.
Sewing needle heating is a common problem for the sewing of technical and medical textiles. The hot needle causes burnt spots on fabric, breakage of the thread, and weak seam strength. Multiple ways are used in industry to cool the needle including compressed air, thread lubrication, and needle coatings. The most economical way of reducing needle heat is to use thread lubrication. This technique needs a lot of research because the bucket of lubrication installed on the sewing machine provides irregular amounts of the micro layer on the thread and there is no research showing how much should be used. In this research, different amounts of pre-lubricated threads are used to measure their impact on coefficient of friction, tensile strength, needle temperature, and overall performance of the seam depending on lubrication amount. The research work is focused on the disadvantages of irregular lubrication and finding optimized lubricant amount for better sewing performance with low needle temperature. Full article
Show Figures

Graphical abstract

20 pages, 12225 KiB  
Article
Influence of Hot Deformation Temperature on Grain Size and γ′ Phase in U720Li Alloy After Sub-Solvus Heat Treatment
by Junyi Cheng, Jiangying Xiong, Anping Long, Lei Xiao, Xiangdong Ma, Ganjiang Feng and Jianzheng Guo
Metals 2025, 15(4), 409; https://doi.org/10.3390/met15040409 - 4 Apr 2025
Viewed by 369
Abstract
Precise control of forging and heat treatment parameters is essential to achieve microstructural homogeneity in turbine disks, ensuring optimal mechanical performance for aerospace applications. This study examines the influence of the hot deformation temperatures on the grain size and γ′ phase characteristics of [...] Read more.
Precise control of forging and heat treatment parameters is essential to achieve microstructural homogeneity in turbine disks, ensuring optimal mechanical performance for aerospace applications. This study examines the influence of the hot deformation temperatures on the grain size and γ′ phase characteristics of U720Li alloy following subsequent heat treatments. Samples extracted from a hot-extruded U720Li billet were subjected to isothermal compression within the temperature range of 1100–1130 °C, followed by holding at 1100 °C and 1120 °C for 4 h and air cooling. The results demonstrate that increasing the deformation temperature from 1100 °C to 1120 °C reduces the γ′ phase volume fraction at grain boundaries from 13% to 5%, weakens pinning effects, promotes grain growth during deformation, elevates grain boundary energy, and diminishes stored deformation energy, despite maintaining an equivalent degree of dynamic recrystallization. When the sub-solvus heat treatment temperature was 20 °C below the effective deformation temperature, Ostwald ripening dominated, resulting in a multimodal γ′ phase distribution after cooling. Conversely, when the sub-solvus heat treatment temperature 20 °C exceeded the effective deformation temperature, a significant portion of the intergranular γ′ phase dissolved, leaving a bimodal distribution comprising both large- and small-sized particles. Full article
Show Figures

Figure 1

35 pages, 5370 KiB  
Review
Review Analysis for the Energy Performance of Integrated Air-Conditioning Systems
by Faisal Alghamdi and Moncef Krarti
Energies 2025, 18(7), 1611; https://doi.org/10.3390/en18071611 - 24 Mar 2025
Cited by 1 | Viewed by 1773
Abstract
In response to the significant increase in cooling needs for the built environment due to climate change, hybrid air conditioning units can provide energy efficient alternatives to vapor compression systems. This paper reviews the reported energy performance of integrated air conditioning systems consisting [...] Read more.
In response to the significant increase in cooling needs for the built environment due to climate change, hybrid air conditioning units can provide energy efficient alternatives to vapor compression systems. This paper reviews the reported energy performance of integrated air conditioning systems consisting of three types of hybrid options: direct expansion (DX) combined with evaporative cooling, DX with desiccant, and evaporative cooling combined with desiccant. In addition, the reported analyses of integrating these hybrid systems with phase change materials (PCMs) and/or photovoltaic (PV) systems are considered. The evaluated analyses generally confirm that integrated air conditioning systems offer substantial energy saving potential compared to traditional vapor compression cooling units, resulting in substantial economic and environmental benefits. Specifically, hybrid systems can reduce the annual energy consumption for space cooling by 87% compared to traditional air conditioning units. This review analysis indicates that hybrid systems can have a coefficient of performance (COP) ranging from 6 to 16 compared to merely 3 to 5 for conventional systems. Additionally, liquid desiccant cooling systems have reported notable improvements in dehumidification efficiency and energy savings, with payback periods as low as three years. Future work should focus more on real-building applications and on conducting more comprehensive cost–benefit analyses, especially when integrating more than two technologies together. Full article
(This article belongs to the Special Issue Energy Efficiency and Energy Performance in Buildings)
Show Figures

Figure 1

35 pages, 9594 KiB  
Article
Effect of Protective Coatings on Post-Fire Performance and Behavior of Mild Steel-Based Cold-Formed Steel Back-to-Back Channel Columns with Bolted Connections
by Varun Sabu Sam, Anand Nammalvar, Andrainik Iswarary, Diana Andrushia, G. Beulah Gnana Ananthi and Krishanu Roy
Fire 2025, 8(3), 107; https://doi.org/10.3390/fire8030107 - 10 Mar 2025
Cited by 3 | Viewed by 1054
Abstract
This study investigates the buckling performance of built-up cold-formed steel (CFS) columns, with a focus on how different thermal exposures and cooling strategies influence their susceptibility to various failure mechanisms. Addressing the gap in the literature on the fire behavior of mild steel [...] Read more.
This study investigates the buckling performance of built-up cold-formed steel (CFS) columns, with a focus on how different thermal exposures and cooling strategies influence their susceptibility to various failure mechanisms. Addressing the gap in the literature on the fire behavior of mild steel (MS)-based CFS columns, the research aims to provide new insights. Compression tests were conducted on MS-based CFS column specimens after they were exposed to fire, to assess their post-fire buckling strength. The columns were subjected to controlled fire conditions following standardized protocols and then allowed to cool to room temperature. The study examined axial load-bearing capacity and deformation characteristics under elevated temperatures. To improve fire resistance, protective coatings—gypsum, perlite, and vermiculite—were applied to certain specimens before testing, and their performance was compared to that of uncoated specimens. A comprehensive finite element analysis (FEA) was also performed to model the structural response under different thermal and cooling scenarios, providing a detailed comparison of the coating effectiveness, which was validated against experimental results. The findings revealed significant variations in axial strength and failure mechanisms based on the type of fire-resistant coating used, as well as the heating and cooling durations. Among the coated specimens, those treated with perlite showed the best performance. For example, the air-cooled perlite-coated column (MBC2AC) retained a load capacity of 277.9 kN after 60 min of heating, a reduction of only 6.0% compared to the unheated reference section (MBREF). This performance was superior to that of the gypsum-coated (MBC1AC) and vermiculite-coated (MBC3AC) specimens, which showed reductions of 3.6% and 7.9% more, respectively. These results highlight the potential of perlite coatings to enhance the fire resistance of CFS columns, offering valuable insights for structural fire design. Full article
Show Figures

Figure 1

16 pages, 7366 KiB  
Article
Potential Applicability of Air-Cooled Ladle Furnace Slag Fine Aggregate in Concrete Production
by Jeongmin Ra, Sunmi Choi, Sangchul Shin and Jinman Kim
Recycling 2025, 10(2), 30; https://doi.org/10.3390/recycling10020030 - 20 Feb 2025
Viewed by 955
Abstract
Electric arc furnace oxidizing slag (EAFOS) represents 80% of the electric arc furnace slag generated. Recently, EAFOS has been utilized as high value-added functional aggregate in a growing number of cases for the construction of air-cooling technology that turns EAFOS into fine aggregate-sized [...] Read more.
Electric arc furnace oxidizing slag (EAFOS) represents 80% of the electric arc furnace slag generated. Recently, EAFOS has been utilized as high value-added functional aggregate in a growing number of cases for the construction of air-cooling technology that turns EAFOS into fine aggregate-sized particles by spraying it into the air using high-pressure compressed air. Ladle furnace slag (LFS) is a product of the reduction process, accounting for approximately 20% of the steel slag enerated; however, LFS is predominantly landfilled without being utilized. This is mainly because LFS changes into sludge as it is turned into powder during water spray cooling. Therefore, in this study, spherical particles cooled at room temperature were fabricated as fine aggregates using LFS by applying atomization technology that uses high-pressure air in the molten state for the value-added utilization of LFS. Various experiments were performed to examine whether this aggregate can be used as a construction material. The experimental results showed that the air-cooled LFS (ALFS) fine aggregate generated from two different processes met the physical and chemical properties of the fine aggregate required for concrete despite its slightly lower spherical ratio compared to EAFOS aggregate. The volumetric stability experiment results also showed that ALFS fine aggregate is more stable than river sand and standard sand. In addition, the autoclave test results revealed that the mortar produced using ALFS fine aggregate was more stable for expansion than that of comparison groups. These results confirm the applicability of ALFS as an aggregate for construction. However, because the pop-out phenomenon caused by MgO was observed on the surface of some specimens, further research is required for improvement. Full article
Show Figures

Figure 1

Back to TopTop