Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (6)

Search Parameters:
Keywords = connection and disconnection abutment

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 2435 KiB  
Case Report
The First Biological Respect Protocol: A Biodigital Technique for Definitive Customized One-Time Abutments—A Case Report
by Franco Rizzuto and Silvia Rizzuto
J. Clin. Med. 2025, 14(13), 4448; https://doi.org/10.3390/jcm14134448 - 23 Jun 2025
Viewed by 335
Abstract
Background/Objectives: Dental implants represent a viable solution for replacing missing teeth; however, multiple disconnections and reconnections of intermediate abutments contribute to the apical displacement of the peri-implant connective tissue barrier, resulting in additional marginal bone loss. To the best of our knowledge, no [...] Read more.
Background/Objectives: Dental implants represent a viable solution for replacing missing teeth; however, multiple disconnections and reconnections of intermediate abutments contribute to the apical displacement of the peri-implant connective tissue barrier, resulting in additional marginal bone loss. To the best of our knowledge, no definitive customized abutments currently exist that are specifically designed according to the morphology of the tooth to be replaced and its position within the dental arch, allowing for digital planning within the prosthetic implant design and insertion during the surgical procedure without subsequent disconnection. Methods: The First Biological Respect (FR) technique, described in this case report, enables the digital planning not only of the implant but also of the patented FR customized-shaped, definitive abutment and associated FR prosthetic components. The FR technique was applied to a case involving an immediate post-extraction implant in position 12. Results: With the limitations of a case report, the application of the FR protocol demonstrated stable crestal bone levels at the 1-year follow-up. Additionally, soft tissue volume was maintained at 6 months, reflecting the accuracy of the customized prosthetic components in supporting, guiding, and protecting peri-implant soft tissues. At the 1-year follow-up, an increase in soft tissue volume was observed, likely attributable to tissue maturation and the further customization of the definitive prosthetic elements. Conclusions: The FR technique represents a viable therapeutic alternative that, through its patented, fully customized components, allows for the digital planning of the implant, as well as the customized definitive abutment, coping, provisional, and final prosthetic framework. This facilitates a single-stage surgical and prosthetic approach. By eliminating the need for repeated abutment disconnections, this method supports the long-term stability of both hard and soft peri-implant tissues while also reducing overall treatment time for both clinician and patient. Further studies involving larger patient cohorts are necessary to validate this protocol. Full article
(This article belongs to the Section Dentistry, Oral Surgery and Oral Medicine)
Show Figures

Figure 1

11 pages, 2063 KiB  
Article
Mechanical Behavior of Five Different Morse Taper Implants and Abutments with Different Conical Internal Connections and Angles: An In Vitro Experimental Study
by Claudia Caballero, Fernando Rodriguez, Guillermo Castro Cortellari, Antonio Scarano, Juan Carlos Prados-Frutos, Piedad N. De Aza, Gustavo Vicentis Oliveira Fernandes and Sergio Alexandre Gehrke
J. Funct. Biomater. 2024, 15(7), 177; https://doi.org/10.3390/jfb15070177 - 28 Jun 2024
Cited by 8 | Viewed by 3688
Abstract
The present study evaluated the mechanical behavior of five designs of Morse taper (MT) connections with and without the application of loads. For this, the detorque of the fixing screw and the traction force required to disconnect the abutment from the implant were [...] Read more.
The present study evaluated the mechanical behavior of five designs of Morse taper (MT) connections with and without the application of loads. For this, the detorque of the fixing screw and the traction force required to disconnect the abutment from the implant were assessed. A total of 100 sets of implants/abutments (IAs) with MT-type connections were used, comprising five groups (n = 20/group): (1) Group Imp 11.5: IA sets with a cone angulation of 11.5°; (2) Group SIN 11.5: with a cone angulation of 11.5°; (3) Group SIN 16: with a cone angulation of 16°; (4) Group Neo 16: with a cone angulation of 16°; and (5) Group Str 15: with a cone angulation of 15°. All sets received the torque recommended by the manufacturer. After applying the torque, the counter torque of the fixing screws was measured in ten IA sets of each group without the application of cyclic loads (frequencies ≤ 2 Hz, 360,000 cycles, and force at 150 Ncm). The other ten sets of each group were subjected to cyclic loads, after which the detorque was measured. Afterwards, the force for disconnection between the implant and the abutment was measured by traction on all the samples. The untwisting of the abutment fixation screws showed a decrease in relation to the initial torque applied in all groups. In the unloaded samples, it was found to be −25.7% in Group 1, −30.4% in Group 2, −36.8% in Group 3, −29.6% in Group 4, and −25.7% in Group 5. After the applied loads, it was found to be −44% in Group 1, −43.5% in Group 2, −48.5% in Group 3, −47.2% in Group 4, and −49.8% in Group 5. The values for the IA sets were zero for SIN 16 (Group 3) and Neo16 (Group 4), both without and with loads. In the other three groups, without loads, the disconnection value was 56.3 ± 2.21 N (Group 1), 30.7 ± 2.00 N (Group 2), and 26.0 ± 2.52 N (Group 5). After applying loads, the values were 63.5 ± 3.06 N for Group 1, 34.2 ± 2.45 N in Group 2, and 23.1 ± 1.29 N in Group 5. It was concluded that in terms of the mechanical behavior of the five designs of MT IA sets, with and without the application of loads, the Imp 11.5, SIN 11.5, and Srt 15 groups showed better results compared to the SIN 16 and Neo 16 groups, showing that lower values of cone angulation increase the friction between the parts (IA), thus avoiding the need to maintain the torque of the fixing screw to maintain the union of the sets. Full article
(This article belongs to the Special Issue Advances in Oral and Maxillofacial Implants)
Show Figures

Figure 1

18 pages, 5275 KiB  
Article
The Association of the One-Abutment at One-Time Concept with Marginal Bone Loss around the SLA and Platform Switch and Conical Abutment Implants
by Nasreen Hamudi, Eitan Barnea, Evgeny Weinberg, Amir Laviv, Eitan Mijiritsky, Shlomo Matalon, Liat Chaushu and Roni Kolerman
J. Clin. Med. 2022, 11(1), 74; https://doi.org/10.3390/jcm11010074 - 24 Dec 2021
Cited by 12 | Viewed by 4656
Abstract
Objectives: Repeated abutment disconnection/reconnection may compromise the mucosal barrier and result in crestal bone level changes. The clinical significance of this phenomenon is not yet clear, as most studies on this topic are short-term. Therefore, the aim of the present study was to [...] Read more.
Objectives: Repeated abutment disconnection/reconnection may compromise the mucosal barrier and result in crestal bone level changes. The clinical significance of this phenomenon is not yet clear, as most studies on this topic are short-term. Therefore, the aim of the present study was to evaluate the influence of abutment disconnections and reconnections on peri-implant marginal bone loss over a medium-term follow-up period. Material and methods: Twenty-one patients (6 men and 15 women) with a mean age 66.23 ± 9.35 year at the time of implant placement were included. All patients who received two adjacent nonsubmerged implants were randomly assigned into one of the two groups: definitive multiunit abutments (DEFs) connected to the implant that were not removed (test group) or healing abutments (HEAs) placed at surgery, which were disconnected and reconnected 3–5 times during the prosthetic phase (control group). Peri-implant marginal bone levels (MBL) were measured through periapical X-rays images acquired immediately after the surgery (baseline), at 4–7 months immediately after prosthetic delivery, and at 1-year and 3-year follow-up visits. Results: No implant was lost or presented bone loss of more than 1.9 mm during the 3-year follow-up; thus, the survival and success rate was 100%. Peri-implant mucositis was noticed in 38.1% DEFs and 41.9% of HEAs at the 3-year follow-up assessment. At the end of 3 years, the MBL was −0.35 ± 0.69 mm for participants in the DEFs group and −0.57 ± 0.80 mm for the HEAs group, with significant statistical difference between groups. Conclusions: Immediate connection of the multiunit abutments reduced bone loss in comparison with 3–5 disconnections noted in the healing abutments 3 years after prosthetic delivery. However, the difference between the groups was minimal; thus, the clinical relevance of those results is doubtful. Full article
(This article belongs to the Topic State-of-the-Art Dentistry and Oral Health)
Show Figures

Figure 1

18 pages, 1851 KiB  
Article
One-Abutment One-Time Effect on Peri-Implant Marginal Bone: A Prospective, Controlled, Randomized, Double-Blind Study
by Filipe Moreira, Salomão Rocha, Francisco Caramelo and João P. Tondela
Materials 2021, 14(15), 4179; https://doi.org/10.3390/ma14154179 - 27 Jul 2021
Cited by 8 | Viewed by 3233
Abstract
Objective: To evaluate the peri-implant hard tissue change at 6 and 12 months after implant placement between definitive abutment placed at the same time of implant surgery, never removing it, and healing abutment disconnected and reconnected three times until the placement of the [...] Read more.
Objective: To evaluate the peri-implant hard tissue change at 6 and 12 months after implant placement between definitive abutment placed at the same time of implant surgery, never removing it, and healing abutment disconnected and reconnected three times until the placement of the final rehabilitation. Material and methods: Each partial edentulous patient could receive between 1 and 4 platform-switched implants in the posterior regions. If the implants had primary stability—implant stability quotient (ISQ) equal to or greater than 50, they were randomized to the test group with the abutment inserted at the same time of implant placement (DA) or to the control group, receiving a healing abutment (PA). At 6 and 12 months after surgery, data related with vertical bone level changes (primary outcome) and other clinical parameters (implant mobility, bleeding on probing, probing depth, plaque index) were assessed. Results: 53 implants were included in the trial and completed 12 months follow-up (overall survival rate: 100%). All implants achieved primary stability, with an average ISQ value of 80.9 on the day of surgery. From surgery to 6 months, the mean bone loss was 0.14 ± 0.18 mm for the DA group and 0.23 ± 0.29 mm for the PA group, without statistical significance difference. Between 6 and 12 months, the mean bone loss was 0.14 ± 0.21 mm for the DA group and 0.21 ± 0.27 mm for the PA group, also without statistical significance between the two groups. There were no statistically significant differences (p = 0.330) in total bone loss after 12 months between the control and the study groups. Conclusions: The one abutment one time protocol has at least an equivalent effect on the peri-implant bone level changes when compared with the use of healing abutments that are disconnected and reconnected at least three times. Full article
(This article belongs to the Special Issue Surface Modification of Dental Materials and Tissues)
Show Figures

Figure 1

17 pages, 1886 KiB  
Article
One Abutment One Time: A Multicenter, Prospective, Controlled, Randomized Study
by José Vicente Ríos-Santos, Gregorio Tello-González, Pedro Lázaro-Calvo, Francisco Javier Gil Mur, Blanca Ríos-Carrasco, Ana Fernández-Palacín and Mariano Herrero-Climent
Int. J. Environ. Res. Public Health 2020, 17(24), 9453; https://doi.org/10.3390/ijerph17249453 - 17 Dec 2020
Cited by 12 | Viewed by 4373
Abstract
Aim: (PRIMARY) Assess the changes in bone level (6 and 12 months after implant placement) between the test (definitive abutment (DEF)) and control (healing abutment (HEA)) groups. (SECONDARY) Assess the changes in bone level (6 and 12 months after implant placement) between [...] Read more.
Aim: (PRIMARY) Assess the changes in bone level (6 and 12 months after implant placement) between the test (definitive abutment (DEF)) and control (healing abutment (HEA)) groups. (SECONDARY) Assess the changes in bone level (6 and 12 months after implant placement) between the 1 mm high abutment group and 2 mm abutment group. Evaluate changes in implant stability recorded with analysis of the resonance frequency (RFA) Osstell system, at 6 and 12 months after implant placement, between the control group (HEA) and test (DEF). For the DEF group, the abutment was placed at the time of the surgery and was never removed. For the HEA group, the abutment was removed three times during the manufacture of the crowns. The abutments used were 1 mm high (Subgroup A) and 2 mm high (Subgroup B). Materials and methods: A total of 147 patients were selected between 54.82 ± 11.92 years old. After implant placement, patients were randomly distributed in the DEF and HEA group. After the implant placement, a periapical radiograph was taken to assess the peri-implant bone level; the same procedure was carried out 6 and 12 months post-placement. To compare the qualitative variables between the groups (HEA/DEF), the Chi-square test was used; for quantitative (MANOVA). Results: After a year, the accumulated bone loss was 0.48 ± 0.71 mm for the HEA group and 0.36 ± 0.79 mm for the DEF group, without statistical significance. Differences were only found due to timing (time) between 0 and 6 months (=0.001) and 0 and 12 months (0.001), with no differences attributable to the study groups (DEF and HEA). The accumulated bone loss (1 year) was 0.45 ± 0.78 mm for the 1 mm abutment group and 0.41 ± 0.70 mm for the 2 mm abutment group (p = 0.02). No differences were observed in implant stability between groups. Conclusions: The “One Abutment—One Time” concept does not reduce peri-implant bone loss compared to the connection–disconnection technique. The height of the abutment does influence bone loss: the higher the abutment, the lower the bone loss. Full article
(This article belongs to the Special Issue Implant-Prosthetic Rehabilitation and Maintenance)
Show Figures

Figure 1

12 pages, 870 KiB  
Article
Control of Peri-Implant Mucous Inflammation by Using Chlorhexidine or Ultraviolet C Radiation for Cleaning Healing Abutments. Double-Blind Randomized Clinical Trial
by Arturo Sanchez-Perez, Ana I. Nicolas-Silvente, Carmen Sanchez-Matas, Elena Cascales-Pina, Vanesa Macia-Manresa and Georgios E. Romanos
Materials 2020, 13(5), 1124; https://doi.org/10.3390/ma13051124 - 3 Mar 2020
Cited by 5 | Viewed by 3593
Abstract
Two-phase implants must be exposed to the external environment after the period of osteointegration has elapsed. For this purpose, a healing abutment is placed passing through the mucosa while forming the emergence profile. The continuous connection and disconnection can lead to an alteration [...] Read more.
Two-phase implants must be exposed to the external environment after the period of osteointegration has elapsed. For this purpose, a healing abutment is placed passing through the mucosa while forming the emergence profile. The continuous connection and disconnection can lead to an alteration in the tissue maturation, both because of the contact of bacterial plaque and because of the mechanical trauma that involves its manipulation, manifesting with different degrees of erythema or bleeding. To assess whether this epithelium disruption can be counteracted, a blinded study design was developed on 150 unitary implant patients divided into three groups (n = 50), applying chlorhexidine (group 1), ultraviolet C (UV-C) at a wavelength of 254 nm (group 2)and no treatment as a control group (group 3), during each of the disconnections and connections during the prosthodontic treatment (1 time per week for four weeks). All groups showed a better epithelium aspect at the end of the evaluation. Although there were no statistically significant differences in the degree of inflammation, the UV-C treated group had the lowest plaque accumulation, and the highest was for the chlorhexidine-treated group. Full article
(This article belongs to the Special Issue Materials in Implant Dentistry and Regenerative Medicine)
Show Figures

Figure 1

Back to TopTop