Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = automated disk-based solid-phase extraction

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
13 pages, 7735 KB  
Article
Determination and Ecological Risk Assessment of Quinolone Antibiotics in Drinking and Environmental Waters Using Fully Automated Disk-Based SPE Coupled with UPLC–MS/MS
by Hongmei Hu, Xingyu Da, Zhenhua Li, Tiejun Li, Xiaoning Zhang, Tianbin Bian, Yanjian Jin, Kaida Xu and Yuanming Guo
Molecules 2024, 29(19), 4611; https://doi.org/10.3390/molecules29194611 - 28 Sep 2024
Cited by 11 | Viewed by 2664
Abstract
Quinolone antibiotics (QNs) contamination in the aquatic environment is a global public health issue considering their resistance and mobility. In this study, a simple, efficient, and sensitive method was developed for the accurate quantification of fifteen QNs in water using automated disk-based solid-phase [...] Read more.
Quinolone antibiotics (QNs) contamination in the aquatic environment is a global public health issue considering their resistance and mobility. In this study, a simple, efficient, and sensitive method was developed for the accurate quantification of fifteen QNs in water using automated disk-based solid-phase extraction (SPE) coupled with ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS). By utilizing a 3M SDB-XC disk to enrich QNs from a 1000 mL water sample, the detection limits were improved to 0.008–0.055 ng/L due to the satisfactory enrichment factors of 897−1136, but only requiring about 60 min per six samples. The linearity of the method ranged from 0.05 to 100 μg/L for the 15 QNs, with correlation coefficients of 0.9992–0.9999, and the recoveries were in the range of 81–114%, with relative standard deviations of 0.2–13.3% (n = 6). The developed method was applicable for the quantification of trace QNs at low ng/L levels in drinking and environmental waters. The results showed that no QNs were detected in tap water, while three and four QNs were detected in the river water of Zhoushan and the seawater of Daiquyang and Yueqing Bay, East China, respectively, with a total concentration of 1.600–8.511 ng/L and 1.651–16.421 ng/L, respectively. Among the detected QNs, ofloxacin (OFL) was the predominant compound in river water, while enrofloxacin (ENR) was predominant in seawater. The risk quotient (RQ) results revealed that QNs posed a low risk to crustaceans and fish, but a low-to-medium risk to algae, and OFL presented the main ecological risk factor in river water, while ENR and CIP in seawater. Overall, the proposed automated disk-based SPE–UPLC–MS/MS method is highly efficient and sensitive, making it suitable for routine analysis of QNs in drinking and environmental waters. Full article
(This article belongs to the Special Issue Advanced Analysis of Contaminants of Emerging Concern: Volume II)
Show Figures

Figure 1

16 pages, 3354 KB  
Article
Magnetophoresis in Centrifugal Microfluidics at Continuous Rotation for Nucleic Acid Extraction
by Sebastian Hin, Nils Paust, Markus Rombach, Jan Lüddecke, Mara Specht, Roland Zengerle and Konstantinos Mitsakakis
Micromachines 2022, 13(12), 2112; https://doi.org/10.3390/mi13122112 - 29 Nov 2022
Cited by 11 | Viewed by 3675
Abstract
Centrifugal microfluidics enables fully automated molecular diagnostics at the point-of-need. However, the integration of solid-phase nucleic acid extraction remains a challenge. Under this scope, we developed the magnetophoresis under continuous rotation for magnetic bead-based nucleic acid extraction. Four stationary permanent magnets are arranged [...] Read more.
Centrifugal microfluidics enables fully automated molecular diagnostics at the point-of-need. However, the integration of solid-phase nucleic acid extraction remains a challenge. Under this scope, we developed the magnetophoresis under continuous rotation for magnetic bead-based nucleic acid extraction. Four stationary permanent magnets are arranged above a cartridge, creating a magnetic field that enables the beads to be transported between the chambers of the extraction module under continuous rotation. The centrifugal force is maintained to avoid uncontrolled spreading of liquids. We concluded that below a frequency of 5 Hz, magnetic beads move radially inwards. In support of magnetophoresis, bead inertia and passive geometrical design features allow to control the azimuthal bead movement between chambers. We then demonstrated ferrimagnetic bead transfer in liquids with broad range of surface tension and density values. Furthermore, we extracted nucleic acids from lysed Anopheles gambiae mosquitoes reaching comparable results of eluate purity (LabDisk: A260/A280 = 1.6 ± 0.04; Reference: 1.8 ± 0.17), and RT-PCR of extracted RNA (LabDisk: Ct = 17.9 ± 1.6; Reference: Ct = 19.3 ± 1.7). Conclusively, magnetophoresis at continuous rotation enables easy cartridge integration and nucleic acid extraction at the point-of-need with high yield and purity. Full article
(This article belongs to the Special Issue Microfluidics for Health Monitoring)
Show Figures

Figure 1