Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (11)

Search Parameters:
Keywords = artery pulsation monitoring

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 5866 KiB  
Article
Core-Sheath Structured Yarn for Biomechanical Sensing in Health Monitoring
by Wenjing Fan, Cheng Li, Bingping Yu, Te Liang, Junrui Li, Dapeng Wei and Keyu Meng
Biomimetics 2025, 10(5), 304; https://doi.org/10.3390/biomimetics10050304 - 9 May 2025
Viewed by 660
Abstract
The rapidly evolving field of functional yarns has garnered substantial research attention due to their exceptional potential in enabling next-generation electronic textiles for wearable health monitoring, human–machine interfaces, and soft robotics. Despite notable advancements, the development of yarn-based strain sensors that simultaneously achieve [...] Read more.
The rapidly evolving field of functional yarns has garnered substantial research attention due to their exceptional potential in enabling next-generation electronic textiles for wearable health monitoring, human–machine interfaces, and soft robotics. Despite notable advancements, the development of yarn-based strain sensors that simultaneously achieve high flexibility, stretchability, superior comfort, extended operational stability, and exceptional electrical performance remains a critical challenge, hindered by material limitations and structural design constraints. Here, we present a bioinspired, hierarchically structured core-sheath yarn sensor (CSSYS) engineered through an efficient dip-coating process, which synergistically integrates the two-dimensional conductive MXene nanosheets and one-dimensional silver nanowires (AgNWs). Furthermore, the sensor is encapsulated using a yarn-based protective layer, which not only preserves its inherent flexibility and wearability but also effectively mitigates oxidative degradation of the sensitive materials, thereby significantly enhancing long-term durability. Drawing inspiration from the natural architecture of plant stems—where the inner core provides structural integrity while a flexible outer sheath ensures adaptive protection—the CSSYS exhibits outstanding mechanical and electrical performance, including an ultralow strain detection limit (0.05%), an ultrahigh gauge factor (up to 744.45), rapid response kinetics (80 ms), a broad sensing range (0–230% strain), and exceptional cyclic stability (>20,000 cycles). These remarkable characteristics enable the CSSYS to precisely capture a broad spectrum of physiological signals, ranging from subtle arterial pulsations and respiratory rhythms to large-scale joint movements, demonstrating its immense potential for next-generation wearable health monitoring systems. Full article
(This article belongs to the Special Issue Bio-Inspired Flexible Sensors)
Show Figures

Graphical abstract

12 pages, 3631 KiB  
Article
Fiber Bragg Grating Pulse and Systolic Blood Pressure Measurement System Based on Mach–Zehnder Interferometer
by Yuanjun Li, Bo Wang, Shanren Liu, Mengmeng Gao, Qianhua Li, Chao Chen, Qi Guo and Yongsen Yu
Sensors 2024, 24(19), 6222; https://doi.org/10.3390/s24196222 - 26 Sep 2024
Cited by 1 | Viewed by 1624
Abstract
A fiber Bragg grating (FBG) pulse and systolic blood pressure (SBP) measurement system based on the edge-filtering method is proposed. The edge filter is the Mach–Zehnder interferometer (MZI) fabricated by two fiber couplers with a linear slope of 52.45 dBm/nm. The developed system [...] Read more.
A fiber Bragg grating (FBG) pulse and systolic blood pressure (SBP) measurement system based on the edge-filtering method is proposed. The edge filter is the Mach–Zehnder interferometer (MZI) fabricated by two fiber couplers with a linear slope of 52.45 dBm/nm. The developed system consists of a broadband light source, an edge filter, fiber Bragg gratings (FBGs), a coarse wavelength-division multiplexer (CWDM), and signal-processing circuits based on a field-programmable gate array (FPGA). It can simultaneously measure pulse pulsations of the radial artery in the wrist at three positions: Cun, Guan and Chi. The SBP can be calculated based on the pulse transit time (PTT) principle. The measurement results compared to a standard blood pressure monitor showed the mean absolute error (MAE) and standard deviation (STD) of the SBP were 0.93 ± 3.13 mmHg. The system meets the requirements of the Association for the Advancement of Medical Instrumentation (AAMI) equipment standards. The proposed system can achieve continuous real-time measurement of pulse and SBP and has the advantages of fast detection speed, stable performance, and no compression sensation for subjects. The system has important application value in the fields of human health monitoring and medical device development. Full article
(This article belongs to the Section Optical Sensors)
Show Figures

Figure 1

19 pages, 12908 KiB  
Article
A 3D-Printed Piezoelectric Microdevice for Human Energy Harvesting for Wearable Biosensors
by Ihor Sobianin, Sotiria D. Psoma and Antonios Tourlidakis
Micromachines 2024, 15(1), 118; https://doi.org/10.3390/mi15010118 - 10 Jan 2024
Cited by 7 | Viewed by 2956
Abstract
The human body is a source of multiple types of energy, such as mechanical, thermal and biochemical, which can be scavenged through appropriate technological means. Mechanical vibrations originating from contraction and expansion of the radial artery represent a reliable source of displacement to [...] Read more.
The human body is a source of multiple types of energy, such as mechanical, thermal and biochemical, which can be scavenged through appropriate technological means. Mechanical vibrations originating from contraction and expansion of the radial artery represent a reliable source of displacement to be picked up and exploited by a harvester. The continuous monitoring of physiological biomarkers is an essential part of the timely and accurate diagnosis of a disease with subsequent medical treatment, and wearable biosensors are increasingly utilized for biomedical data acquisition of important biomarkers. However, they rely on batteries and their replacement introduces a discontinuity in measured signals, which could be critical for the patients and also causes discomfort. In the present work, the research into a novel 3D-printed wearable energy harvesting platform for scavenging energy from arterial pulsations via a piezoelectric material is described. An elastic thermoplastic polyurethane (TPU) film, which forms an air chamber between the skin and the piezoelectric disc electrode, was introduced to provide better adsorption to the skin, prevent damage to the piezoelectric disc and electrically isolate components in the platform from the human body. Computational fluid dynamics in the framework of COMSOL Multiphysics 6.1 software was employed to perform a series of coupled time-varying simulations of the interaction among a number of associated physical phenomena. The mathematical model of the harvester was investigated computationally, and quantification of the output energy and power parameters was used for comparisons. A prototype wearable platform enclosure was designed and manufactured using fused filament fabrication (FFF). The influence of the piezoelectric disc material and its diameter on the electrical output were studied and various geometrical parameters of the enclosure and the TPU film were optimized based on theoretical and empirical data. Physiological data, such as interdependency between the harvester skin fit and voltage output, were obtained. Full article
Show Figures

Figure 1

17 pages, 6472 KiB  
Article
Microwave Angiography by Ultra-Wideband Sounding: A Preliminary Investigation
by Somayyeh Chamaani, Jürgen Sachs, Alexandra Prokhorova, Carsten Smeenk, Tim Erich Wegner and Marko Helbig
Diagnostics 2023, 13(18), 2950; https://doi.org/10.3390/diagnostics13182950 - 14 Sep 2023
Cited by 1 | Viewed by 1449
Abstract
Angiography is a very informative method for physicians such as cardiologists, neurologists and neuroscientists. The current modalities experience some shortages, e.g., ultrasound is very operator dependent. The computerized tomography (CT) and magnetic resonance (MR) angiography are very expensive and near infrared spectroscopy cannot [...] Read more.
Angiography is a very informative method for physicians such as cardiologists, neurologists and neuroscientists. The current modalities experience some shortages, e.g., ultrasound is very operator dependent. The computerized tomography (CT) and magnetic resonance (MR) angiography are very expensive and near infrared spectroscopy cannot capture the deep arteries. Microwave technology has the potential to address some of these issues while compromising between operator dependency, cost, speed, penetration depth and resolution. This paper studies the feasibility of microwave signals for monitoring of arteries. To this aim, a homogenous phantom mimicking body tissue is built. Four elastic tubes simulate arteries and a mechanical system creates pulsations in these arteries. A multiple input multiple output (MIMO) array of ultra-wideband (UWB) transmitters and receivers illuminates the phantom and captures the reflected signals over the desired observation time period. Since we are only interested in the imaging of dynamic parts, i.e., arteries, the static clutters can be suppressed easily by background subtraction method. To obtain a fast image of arteries, which are pulsating with the heartbeat rate, we calculate the Fourier transform of each channel of the MIMO system over the observation time and apply delay and sum (DAS) beamforming method on the heartbeat rate aligned spectral component. The results show that the lateral and longitudinal images and motion mode (M-mode) time series of different points of phantom have the potential to be used for diagnosis. Full article
(This article belongs to the Special Issue Advances in Biomedical Microwave Imaging and Sensing)
Show Figures

Figure 1

17 pages, 3144 KiB  
Article
Sensor-Location-Specific Joint Acquisition of Peripheral Artery Bioimpedance and Photoplethysmogram for Wearable Applications
by Margus Metshein, Anar Abdullayev, Antoine Gautier, Benoit Larras, Antoine Frappe, Barry Cardiff, Paul Annus, Raul Land and Olev Märtens
Sensors 2023, 23(16), 7111; https://doi.org/10.3390/s23167111 - 11 Aug 2023
Cited by 4 | Viewed by 2387
Abstract
Background: Cardiovascular diseases (CVDs), being the culprit for one-third of deaths globally, constitute a challenge for biomedical instrumentation development, especially for early disease detection. Pulsating arterial blood flow, providing access to cardiac-related parameters, involves the whole body. Unobtrusive and continuous acquisition of electrical [...] Read more.
Background: Cardiovascular diseases (CVDs), being the culprit for one-third of deaths globally, constitute a challenge for biomedical instrumentation development, especially for early disease detection. Pulsating arterial blood flow, providing access to cardiac-related parameters, involves the whole body. Unobtrusive and continuous acquisition of electrical bioimpedance (EBI) and photoplethysmography (PPG) constitute important techniques for monitoring the peripheral arteries, requiring novel approaches and clever means. Methods: In this work, five peripheral arteries were selected for EBI and PPG signal acquisition. The acquisition sites were evaluated based on the signal morphological parameters. A small-data-based deep learning model, which increases the data by dividing them into cardiac periods, was proposed to evaluate the continuity of the signals. Results: The highest sensitivity of EBI was gained for the carotid artery (0.86%), three times higher than that for the next best, the posterior tibial artery (0.27%). The excitation signal parameters affect the measured EBI, confirming the suitability of classical 100 kHz frequency (average probability of 52.35%). The continuity evaluation of the EBI signals confirmed the advantage of the carotid artery (59.4%), while the posterior tibial artery (49.26%) surpasses the radial artery (48.17%). The PPG signal, conversely, commends the location of the posterior tibial artery (97.87%). Conclusions: The peripheral arteries are highly suitable for non-invasive EBI and PPG signal acquisition. The posterior tibial artery constitutes a candidate for the joint acquisition of EBI and PPG signals in sensor-fusion-based wearable devices—an important finding of this research. Full article
(This article belongs to the Special Issue Use of Smart Wearable Sensors and AI Methods in Providing P4 Medicine)
Show Figures

Figure 1

36 pages, 17376 KiB  
Article
Continuous Non-Invasive Blood Pressure Measurement Using 60 GHz-Radar—A Feasibility Study
by Nastassia Vysotskaya, Christoph Will, Lorenzo Servadei, Noah Maul, Christian Mandl, Merlin Nau, Jens Harnisch and Andreas Maier
Sensors 2023, 23(8), 4111; https://doi.org/10.3390/s23084111 - 19 Apr 2023
Cited by 20 | Viewed by 7854
Abstract
Blood pressure monitoring is of paramount importance in the assessment of a human’s cardiovascular health. The state-of-the-art method remains the usage of an upper-arm cuff sphygmomanometer. However, this device suffers from severe limitations—it only provides a static blood pressure value pair, is incapable [...] Read more.
Blood pressure monitoring is of paramount importance in the assessment of a human’s cardiovascular health. The state-of-the-art method remains the usage of an upper-arm cuff sphygmomanometer. However, this device suffers from severe limitations—it only provides a static blood pressure value pair, is incapable of capturing blood pressure variations over time, is inaccurate, and causes discomfort upon use. This work presents a radar-based approach that utilizes the movement of the skin due to artery pulsation to extract pressure waves. From those waves, a set of 21 features was collected and used—together with the calibration parameters of age, gender, height, and weight—as input for a neural network-based regression model. After collecting data from 55 subjects from radar and a blood pressure reference device, we trained 126 networks to analyze the developed approach’s predictive power. As a result, a very shallow network with just two hidden layers produced a systolic error of 9.2±8.3 mmHg (mean error ± standard deviation) and a diastolic error of 7.7±5.7 mmHg. While the trained model did not reach the requirements of the AAMI and BHS blood pressure measuring standards, optimizing network performance was not the goal of the proposed work. Still, the approach has displayed great potential in capturing blood pressure variation with the proposed features. The presented approach therefore shows great potential to be incorporated into wearable devices for continuous blood pressure monitoring for home use or screening applications, after improving this approach even further. Full article
(This article belongs to the Special Issue Advanced Wearable Sensors Technologies for Healthcare Monitoring)
Show Figures

Figure 1

24 pages, 9610 KiB  
Article
Matrix Pencil Method for Vital Sign Detection from Signals Acquired by Microwave Sensors
by Somayyeh Chamaani, Alireza Akbarpour, Marko Helbig and Jürgen Sachs
Sensors 2021, 21(17), 5735; https://doi.org/10.3390/s21175735 - 26 Aug 2021
Cited by 8 | Viewed by 3252
Abstract
Microwave sensors have recently been introduced as high-temporal resolution sensors, which could be used in the contactless monitoring of artery pulsation and breathing. However, accurate and efficient signal processing methods are still required. In this paper, the matrix pencil method (MPM), as an [...] Read more.
Microwave sensors have recently been introduced as high-temporal resolution sensors, which could be used in the contactless monitoring of artery pulsation and breathing. However, accurate and efficient signal processing methods are still required. In this paper, the matrix pencil method (MPM), as an efficient method with good frequency resolution, is applied to back-reflected microwave signals to extract vital signs. It is shown that decomposing of the signal to its damping exponentials fulfilled by MPM gives the opportunity to separate signals, e.g., breathing and heartbeat, with high precision. A publicly online dataset (GUARDIAN), obtained by a continuous wave microwave sensor, is applied to evaluate the performance of MPM. Two methods of bandpass filtering (BPF) and variational mode decomposition (VMD) are also implemented. In addition to the GUARDIAN dataset, these methods are also applied to signals acquired by an ultra-wideband (UWB) sensor. It is concluded that when the vital sign is sufficiently strong and pure, all methods, e.g., MPM, VMD, and BPF, are appropriate for vital sign monitoring. However, in noisy cases, MPM has better performance. Therefore, for non-contact microwave vital sign monitoring, which is usually subject to noisy situations, MPM is a powerful method. Full article
(This article belongs to the Special Issue Biomedical Microwave Sensors for Point-of-Care Applications)
Show Figures

Figure 1

13 pages, 2737 KiB  
Article
Bio-Impedance Measurement Optimization for High-Resolution Carotid Pulse Sensing
by Ting-Wei Wang, Hsiao-Wei Chu, Lin Chou, Yen-Ling Sung, Yuan-Ta Shih, Po-Chun Hsu, Hao-Min Cheng and Shien-Fong Lin
Sensors 2021, 21(5), 1600; https://doi.org/10.3390/s21051600 - 25 Feb 2021
Cited by 13 | Viewed by 4990
Abstract
Continuous hemodynamic monitoring is important for long-term cardiovascular healthcare, especially in hypertension. The impedance plethysmography (IPG) based carotid pulse sensing is a non-invasive diagnosis technique for measuring pulse signals and further evaluating the arterial conditions of the patient such as continuous blood pressure [...] Read more.
Continuous hemodynamic monitoring is important for long-term cardiovascular healthcare, especially in hypertension. The impedance plethysmography (IPG) based carotid pulse sensing is a non-invasive diagnosis technique for measuring pulse signals and further evaluating the arterial conditions of the patient such as continuous blood pressure (BP) monitoring. To reach the high-resolution IPG-based carotid pulse detection for cardiovascular applications, this study provides an optimized measurement parameter in response to obvious pulsation from the carotid artery. The influence of the frequency of excitation current, electrode cross-sectional area, electrode arrangements, and physiological site of carotid arteries on IPG measurement resolution was thoroughly investigated for optimized parameters. In this study, the IPG system was implemented and installed on the subject’s neck above the carotid artery to evaluate the measurement parameters. The measurement results within 6 subjects obtained the arterial impedance variation of 2137 mΩ using the optimized measurement conditions, including excitation frequency of 50 kHz, a smaller area of 2 cm2, electrode spacing of 4 cm and 1.7 cm for excitation and sensing functions, and location on the left side of the neck. The significance of this study demonstrates an optimized measurement methodology of IPG-based carotid pulse sensing that greatly improves the measurement quality in cardiovascular monitoring. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

10 pages, 1444 KiB  
Article
Noninvasive Assessment of Aortic Pulse Wave Velocity by the Brachial Occlusion-Cuff Technique: Comparative Study
by Vratislav Fabian, Lukas Matera, Kristyna Bayerova, Jan Havlik, Vaclav Kremen, Jan Pudil, Pavol Sajgalik and David Zemanek
Sensors 2019, 19(16), 3467; https://doi.org/10.3390/s19163467 - 8 Aug 2019
Cited by 13 | Viewed by 4882
Abstract
Cardiovascular diseases are one of most frequent cause of morbidity and mortality in the world. There is an emerging need for integrated, non-invasive, and easy-to-use clinical tools to assess accurately cardiovascular system primarily in the preventative medicine. We present a novel design for [...] Read more.
Cardiovascular diseases are one of most frequent cause of morbidity and mortality in the world. There is an emerging need for integrated, non-invasive, and easy-to-use clinical tools to assess accurately cardiovascular system primarily in the preventative medicine. We present a novel design for a non-invasive pulse wave velocity (PWV) assessment method integrated in a single brachial blood pressure monitor allowing for up to 100 times more sensitive recording of the pressure pulsations based on a brachial occlusion-cuff (suprasystolic) principle. The monitor prototype with built-in proprietary method was validated with a gold standard reference technique SphygmoCor VX device. The blood pressure and PWV were assessed on twenty-five healthy individuals (9 women, age (37 ± 13) years) in a supine position at rest by a brachial cuff blood pressure monitor prototype, and immediately re-tested using a gold standard method. PWV using our BP monitor was (6.67 ± 0.96) m/s compared to PWV determined by SphygmoCor VX (6.15 ± 1.01) m/s. The correlation between methods using a Pearson’s correlation coefficient was r = 0.88 (p < 0.001). The study demonstrates the feasibility of using a single brachial cuff build-in technique for the assessment of the arterial stiffness from a single ambulatory blood pressure assessment. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

13 pages, 5773 KiB  
Article
Estimation of Blood Pressure in the Radial Artery Using Strain-Based Pulse Wave and Photoplethysmography Sensors
by Yu-Jen Wang, Chia-Hsien Chen, Chung-Yang Sue, Wen-Hsien Lu and Yee-Hsuan Chiou
Micromachines 2018, 9(11), 556; https://doi.org/10.3390/mi9110556 - 29 Oct 2018
Cited by 49 | Viewed by 12965
Abstract
Blood pressure (BP) is a crucial indicator of cardiac health and vascular status. This study explores the relationship between radial artery BP and wrist skin strain. A BP estimation method based on the physical model of wrist skin tissues and pulse wave velocity [...] Read more.
Blood pressure (BP) is a crucial indicator of cardiac health and vascular status. This study explores the relationship between radial artery BP and wrist skin strain. A BP estimation method based on the physical model of wrist skin tissues and pulse wave velocity (PWV) is proposed. A photoplethysmography (PPG) sensor and strain gauge are used in this method. The developed strain-based pulse wave sensor consists of a pressing force sensor, which ensures consistent pressing force, and a strain gauge, which measures the cardiac pulsation on the wrist skin. These features enable long-term BP monitoring without incurring the limb compression caused by a cuff. Thus, this method is useful for individuals requiring continuous BP monitoring. In this study, the BP of each participant was measured in three modes (before, during, and after exercise), and the data were compared using a clinically validated sphygmomanometer. The percentage errors of diastolic and systolic BP readings were, respectively, 4.74% and 4.49% before exercise, 6.38% and 6.10% during exercise, and 5.98% and 4.81% after a rest. The errors were compared with a clinically validated sphygmomanometer. Full article
Show Figures

Figure 1

12 pages, 3037 KiB  
Article
Artificial Circulatory Model for Analysis of Human and Artificial Vessels
by Andrzej Polanczyk, Markus Klinger, Josif Nanobachvili, Ihor Huk and Christoph Neumayer
Appl. Sci. 2018, 8(7), 1017; https://doi.org/10.3390/app8071017 - 22 Jun 2018
Cited by 33 | Viewed by 5447
Abstract
Background: Ex vivo computer controlled circulatory reactors are advantageous for the investigation of circulatory systems. So far, most of the models have dealt with laminar or pulsatile flow. This study aimed to monitor blood vessel and vessel graft compliance continuously under physiological flow [...] Read more.
Background: Ex vivo computer controlled circulatory reactors are advantageous for the investigation of circulatory systems. So far, most of the models have dealt with laminar or pulsatile flow. This study aimed to monitor blood vessel and vessel graft compliance continuously under physiological flow in real time. Methods: Human common iliac arteries and silicon tubes served as interposition grafts. Changes in wall diameter and displacement were analyzed. The artificial circulatory system (ACM) presented an “artificial heart” able to simulate various ejection pressures, ejection volumes (EV), and frequencies of pulsation (FP). ACM was validated by comparing medical data reconstructed with the 2D-speckle-tracking-technique (2DSTT). Results: Silicon tubes were more rigid compared to iliac arteries, as changes in diameter were approximately 48% lower (0.56 ± 0.007 mm vs. 0.83 ± 0.016 mm, p < 0.0001, for EV = 70 mL and FP = 60 min−1). Wall displacement was 2.3-fold less pronounced in silicon tubes (1.45 ± 0.032 mm vs. 5.79 ± 0.043 mm for iliac arteries (p < 0.0001)). FP and EV did not further increase differences in wall displacement between both types of grafts. There were no significant changes between results gathered from ACM and 2DSTT. Conclusions: The ACM was successfully validated by 2DSTT with the use of selected grafts. It may become a useful tool to investigate different types of vascular grafts. Full article
(This article belongs to the Section Applied Biosciences and Bioengineering)
Show Figures

Figure 1

Back to TopTop