Analysis of Extreme Meteorological Events in the Central Andes of Peru Using a Set of Specialized Instruments
by José Luis Flores-Rojas, Yamina Silva, Luis Suárez-Salas, René Estevan, Jairo Valdivia-Prado, Miguel Saavedra, Lucy Giraldez, Manuel Piñas-Laura, Danny Scipión, Marco Milla, Sheilendra Kumar and Daniel Martinez-Castro
Atmosphere 2021, 12(3), 408; https://doi.org/10.3390/atmos12030408 - 21 Mar 2021
Cited by 13 | Viewed by 4681
Abstract
A set of instruments to measure several physical, microphysical, and radiative properties of the atmosphere and clouds are essential to identify, understand and, subsequently, forecast and prevent the effects of extreme meteorological events, such as severe rainfall, hailstorms, frost events and high pollution [...] Read more.
A set of instruments to measure several physical, microphysical, and radiative properties of the atmosphere and clouds are essential to identify, understand and, subsequently, forecast and prevent the effects of extreme meteorological events, such as severe rainfall, hailstorms, frost events and high pollution events, that can occur with some regularity in the central Andes of Peru. However, like many other Latin American countries, Peru lacks an adequate network of meteorological stations to identify and analyze extreme meteorological events. To partially remedy this deficiency, the Geophysical Institute of Peru has installed a set of specialized sensors (LAMAR) on the Huancayo observatory (12.04° S, 75.32° W, 3350 m ASL), located in the Mantaro river basin, which is a part of the central Andes of Peru, especially in agricultural areas. LAMAR consists of a set of sensors that are used to measure the main atmosphere and soil variables located in a 30-meter-high tower. It also has a set of high-quality radiation sensors (BSRN station) that helps measure the components of short-wave (SW) (global, diffuse, direct and reflected) and long-wave (LW) (emitted and incident) irradiance mounted in a 6-meter-high tower. Moreover, to analyze the microphysics properties of clouds and rainfall, LAMAR includes a set of profiler radars: A Ka-band cloud profiler (MIRA-35c), a UHF wind profiler (CLAIRE), and a VHF wind profiler (BLTR), along with two disdrometers (PARSIVEL2) and two rain gauges pluviometers. The present study performs a detailed dynamic and energetic analysis of two extreme rainfall events, two intense frost events, and three high-pollution events occurring on the Huancayo observatory between 2018 and 2019. The results show that the rainfall events are similar to the 1965–2019 climatological 90th percentile of the daily accumulated rainfall. The results also highlighted the patterns of reflectivity in function of height for both events, which is measured by highlighting the presence of convective and stratiform rainfall types for both events. The first intense rainfall event was associated with strong easterly circulations at high levels of the atmosphere, and the second one was associated with the presence of strong westerly circulations and the absence of BH-NL system around the central Andes. The first frost event was mainly associated with continuous clear sky conditions in the few previous days, corresponding to a radiative frost event. The second one was mainly associated with the intrusion of cold surges from extra-tropical South America. For both events, the energy budget components were strong-lower in comparison to the mean monthly values during early morning hours. Finally, for the high pollution events, the study identified that the main source of aerosols were the forest fires that took place in Peru with certain contributions from the fires in the northern area of Bolivia. Full article
(This article belongs to the Section Atmospheric Techniques, Instruments, and Modeling)
Show Figures

Figure 1

17 pages, 3180 KB  
Article
Intravaginal Devices and GNSS Collars with Satellite Communication to Detect Calving Events in Extensive Beef Production in Northern Australia
by Christie Pearson, Lucy Lush and Luciano A. González
Remote Sens. 2020, 12(23), 3963; https://doi.org/10.3390/rs12233963 - 3 Dec 2020
Cited by 6 | Viewed by 3754
Abstract
Observing calves at birth may help to identify risk factors for, and reduce, calf loss in extensive beef systems. The objectives of this study were to: (1) evaluate two commercial satellite birth alert systems to enable the observation of newborn calves and (2) [...] Read more.
Observing calves at birth may help to identify risk factors for, and reduce, calf loss in extensive beef systems. The objectives of this study were to: (1) evaluate two commercial satellite birth alert systems to enable the observation of newborn calves and (2) assess behavioral changes of cows around calving. Vaginal Implant Transmitters (VIT) paired with Global Navigation Satellite System (GNSS) collars were worn by 20 cows in Trial 1 and 10 cows in Trial 2 to identify birthing events. The VIT and GNSS collars contained a temperature sensor, accelerometer, and very high frequency (VHF) to communicate with a handheld tracker, and ultra-high frequency (UHF) for communication between the VIT and GNSS collar, which had two-way communication using Iridium satellites. A change (Brand 1) or drop (Brand 2) in temperature of more than 3 °C and inactivity triggered the VIT to communicate an expelled alert to the collar, which transmitted the birth alert information via Iridium (device ID, date, time and geolocation of the GNSS collar at expulsion). Cows and calves were tracked in the paddock following a birth alert to assess their health and status. Overall, true birth alerts occurred in only 27.6% of devices. Cows remained active on the day of calving travelling 5.54 ± 4.11 and 5.00 ± 2.80 km/day compared to 6.45 ± 2.79 and 6.12 ± 2.30 km/d on days when calving did not occur for Trial 1 and 2, respectively (mean ± SD). Average activity of the accelerometer X- and Y-axis on calving day was reduced by 15%–20% compared to other days in Trial 1 (p < 0.05) but not in Trial 2 (p > 0.05). Results suggest that these two birth alert systems are not suitable for use in extensive systems and the further development of the technology is required. Cows in the current trials remained active on the day of, and after, calving, indicating that a faster, real-time alert system and communication protocol would be required to achieve the aim of finding newborn calves. Full article
Show Figures

Graphical abstract

26 pages, 7423 KB  
Article
Current Progress towards the Integration of Thermocouple and Chipless RFID Technologies and the Sensing of a Dynamic Stimulus
by Kevin Mc Gee, Prince Anandarajah and David Collins
Micromachines 2020, 11(11), 1019; https://doi.org/10.3390/mi11111019 - 20 Nov 2020
Cited by 5 | Viewed by 3809
Abstract
To date, no printable chipless Radio Frequency Identification (RFID) sensor-related publications in the current literature discuss the possibility of thermocouple integration, particularly for the use in extreme environments. Furthermore, the effects of a time-dependent stimulus on the scattering parameters of a chipless RFID [...] Read more.
To date, no printable chipless Radio Frequency Identification (RFID) sensor-related publications in the current literature discuss the possibility of thermocouple integration, particularly for the use in extreme environments. Furthermore, the effects of a time-dependent stimulus on the scattering parameters of a chipless RFID have never been discussed in the known literature. This work includes a review of possible methods to achieve this goal and the design and characterization of a Barium Strontium Titanate (BST) based VHF/UHF voltage sensing circuit. Proof-of-concept thermocouple integration was attempted, and subsequent testing was performed using a signal generator. These subsequent tests involved applying ramp and sinusoid voltage waveforms to the circuit and the characteristics of these signals are largely extracted from the scattering response. Overall conclusions of this paper are that thermocouple integration into chipless RFID technology is still a significant challenge and further work is needed to identify methods of thermocouple integration. With that being said, the developed circuit shows promise as being capable of being configured into a conventional chipless RFID DC voltage sensor. Full article
(This article belongs to the Special Issue Next Generation RFID Transponders)
Show Figures

Figure 1

12 pages, 6527 KB  
Article
A Novel Approach for Partial Discharge Measurements on GIS Using HFCT Sensors
by Armando Rodrigo Mor, Luis Carlos Castro Heredia and Fabio Andres Muñoz
Sensors 2018, 18(12), 4482; https://doi.org/10.3390/s18124482 - 18 Dec 2018
Cited by 28 | Viewed by 8207
Abstract
This paper presents a novel measuring system for partial discharge (PD) measurements in Gas Insulated Systems (GIS) using high frequency current transformers (HFCT). The system is based on the measurement of the induced PD currents in the GIS enclosure. In opposition to the [...] Read more.
This paper presents a novel measuring system for partial discharge (PD) measurements in Gas Insulated Systems (GIS) using high frequency current transformers (HFCT). The system is based on the measurement of the induced PD currents in the GIS enclosure. In opposition to the existing antenna technologies that measure the radiated energy in the very high frequency/ultra-high frequency (VHF/UHF) range, the proposed system measures the PD conducted currents in the high frequency (HF) range and below. The foundation of the measurements together with a detailed explanation of the sensor installed conveniently at the bolts of the GIS spacer are presented. An experimental study on the current distribution in the GIS enclosure is described to evaluate the impact of the sensor on the measurements. Laboratory experiments have been performed that show the suitability of this method to properly measure particle discharges caused by corona, surface and free moving particle discharges in SF6. Discharges in the range of 1 to 4 pC have been properly measured. An analysis to evaluate the performance of the method is shown, in comparison to VHF/UHF antenna measurements. The potential benefits of this novel technique rely on the small attenuation of PD signals in the GIS components in the HF range and sample rate reductions. Finally, a discussion on the potential applicability of present cluster and charge calculation techniques to the proposed PD GIS measurement using HFCT is presented. Full article
(This article belongs to the Special Issue UHF and RF Sensor Technology for Partial Discharge Detection)
Show Figures

Figure 1

16 pages, 2522 KB  
Article
Radio-Frequency Localization of Multiple Partial Discharges Sources with Two Receivers
by Guillermo Robles, José Manuel Fresno and Juan Manuel Martínez-Tarifa
Sensors 2018, 18(5), 1410; https://doi.org/10.3390/s18051410 - 3 May 2018
Cited by 7 | Viewed by 4402
Abstract
Spatial localization of emitting sources is especially interesting in different fields of application. The focus of an earthquake, the determination of cracks in solid structures, or the position of bones inside a body are some examples of the use of multilateration techniques applied [...] Read more.
Spatial localization of emitting sources is especially interesting in different fields of application. The focus of an earthquake, the determination of cracks in solid structures, or the position of bones inside a body are some examples of the use of multilateration techniques applied to acoustic and vibratory signals. Radar, GPS and wireless sensors networks location are based on radiofrequency emissions and the techniques are the same as in the case of acoustic emissions. This paper is focused on the determination of the position of sources of partial discharges in electrical insulation for maintenance based on the condition of the electrical equipment. The use of this phenomenon is a mere example of the capabilities of the proposed method but it is very representative because the emission can be electromagnetic in the VHF and UHF ranges or acoustic. This paper presents a method to locate more than one source in space with only two receivers, one of them in a fixed position and the other describing a circumference around the first one. The signals arriving from the different sources to the antennas are first separated using a classification technique based on their spectral components. Then, the individualized time differences of arrival (TDOA) from the sources collected at different angles describe a function, angle versus TDOA, that has all the geometric information needed to locate the source. The paper will show how to derive these functions for any source analytically with the position of the source as unknown parameters. Then, it will be demonstrated that it is possible to fit the curve with experimental measurements of the TDOA to obtain the parameters of the position of each source. Finally, the technique is extended to the localization of the emitter in three dimensions. Full article
Show Figures

Figure 1

18 pages, 1641 KB  
Article
On the Use of Monopole Antennas for Determining the Effect of the Enclosure of a Power Transformer Tank in Partial Discharges Electromagnetic Propagation
by Ricardo Albarracín, Jorge Alfredo Ardila-Rey and Abdullahi Abubakar Mas’ud
Sensors 2016, 16(2), 148; https://doi.org/10.3390/s16020148 - 25 Jan 2016
Cited by 56 | Viewed by 8829
Abstract
A well-defined condition-monitoring for power transformers is key to implementing a correct condition-based maintenance (CBM). In this regard, partial discharges (PD) measurement and its analysis allows to carry out on-line maintenance following the standards IEC-60270 and IEC-60076. However, new PD measurements techniques, such [...] Read more.
A well-defined condition-monitoring for power transformers is key to implementing a correct condition-based maintenance (CBM). In this regard, partial discharges (PD) measurement and its analysis allows to carry out on-line maintenance following the standards IEC-60270 and IEC-60076. However, new PD measurements techniques, such as acoustics or electromagnetic (EM) acquisitions using ultra-high-frequency (UHF) sensors are being taken into account, IEC-62478. PD measurements with antennas and the effect of their EM propagation in power transformer tanks is an open research topic that is considered in this paper. In this sense, an empty tank model is studied as a rectangular cavity and their resonances are calculated and compared with their measurement with a network analyser. Besides, two low cost improved monopole antennas deployed inside and outside of the tank model capture background noise and PD pulses in three different test objects (Nomex, twisted pair and insulator). The average spectrum of them are compared and can be found that mainly, the antenna frequency response, the frequency content distribution depending on the PD source and the enclosure resonances modes are the main factors to be considered in PD acquisitions with these sensors. Finally, with this set-up, it is possible to measure PD activity inside the tank from outside. Full article
(This article belongs to the Special Issue State-of-the-Art Sensors Technology in Spain 2015)