Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (11)

Search Parameters:
Keywords = Electrohysterogram (EHG)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
13 pages, 610 KiB  
Article
Prediction of Preterm Labor from the Electrohysterogram Signals Based on Different Gestational Weeks
by Somayeh Mohammadi Far, Matin Beiramvand, Mohammad Shahbakhti and Piotr Augustyniak
Sensors 2023, 23(13), 5965; https://doi.org/10.3390/s23135965 - 27 Jun 2023
Cited by 5 | Viewed by 3037
Abstract
Timely preterm labor prediction plays an important role for increasing the chance of neonate survival, the mother’s mental health, and reducing financial burdens imposed on the family. The objective of this study is to propose a method for the reliable prediction of preterm [...] Read more.
Timely preterm labor prediction plays an important role for increasing the chance of neonate survival, the mother’s mental health, and reducing financial burdens imposed on the family. The objective of this study is to propose a method for the reliable prediction of preterm labor from the electrohysterogram (EHG) signals based on different pregnancy weeks. In this paper, EHG signals recorded from 300 subjects were split into 2 groups: (I) those with preterm and term labor EHG data that were recorded prior to the 26th week of pregnancy (referred to as the PE-TE group), and (II) those with preterm and term labor EHG data that were recorded after the 26th week of pregnancy (referred to as the PL-TL group). After decomposing each EHG signal into four intrinsic mode functions (IMFs) by empirical mode decomposition (EMD), several linear and nonlinear features were extracted. Then, a self-adaptive synthetic over-sampling method was used to balance the feature vector for each group. Finally, a feature selection method was performed and the prominent ones were fed to different classifiers for discriminating between term and preterm labor. For both groups, the AdaBoost classifier achieved the best results with a mean accuracy, sensitivity, specificity, and area under the curve (AUC) of 95%, 92%, 97%, and 0.99 for the PE-TE group and a mean accuracy, sensitivity, specificity, and AUC of 93%, 90%, 94%, and 0.98 for the PL-TL group. The similarity between the obtained results indicates the feasibility of the proposed method for the prediction of preterm labor based on different pregnancy weeks. Full article
(This article belongs to the Special Issue Machine Learning Methods for Biomedical Data Analysis)
Show Figures

Figure 1

14 pages, 1633 KiB  
Article
N-Beats as an EHG Signal Forecasting Method for Labour Prediction in Full Term Pregnancy
by Thierry Rock Jossou, Zakaria Tahori, Godwin Houdji, Daton Medenou, Abdelali Lasfar, Fréjus Sanya, Mêtowanou Héribert Ahouandjinou, Silvio M. Pagliara, Muhammad Salman Haleem and Aziz Et-Tahir
Electronics 2022, 11(22), 3739; https://doi.org/10.3390/electronics11223739 - 15 Nov 2022
Cited by 11 | Viewed by 3403
Abstract
The early prediction of onset labour is critical for avoiding the risk of death due to pregnancy delay. Low-income countries often struggle to deliver timely service to pregnant women due to a lack of infrastructure and healthcare facilities, resulting in pregnancy complications and, [...] Read more.
The early prediction of onset labour is critical for avoiding the risk of death due to pregnancy delay. Low-income countries often struggle to deliver timely service to pregnant women due to a lack of infrastructure and healthcare facilities, resulting in pregnancy complications and, eventually, death. In this regard, several artificial-intelligence-based methods have been proposed based on the detection of contractions using electrohysterogram (EHG) signals. However, the forecasting of pregnancy contractions based on real-time EHG signals is a challenging task. This study proposes a novel model based on neural basis expansion analysis for interpretable time series (N-BEATS) which predicts labour based on EHG forecasting and contraction classification over a given time horizon. The publicly available TPEHG database of Physiobank was exploited in order to train and test the model, where signals from full-term pregnant women and signals recorded after 26 weeks of gestation were collected. For these signals, the 30 most commonly used classification parameters in the literature were calculated, and principal component analysis (PCA) was utilized to select the 15 most representative parameters (all the domains combined). The results show that neural basis expansion analysis for interpretable time series (N-BEATS) forecasting can forecast EHG signals through training after few iterations. Similarly, the forecasting signal’s duration is determined by the length of the recordings. We then deployed XG-Boost, which achieved the classification accuracy of 99 percent, outperforming the state-of-the-art approaches using a number of classification features greater than or equal to 15. Full article
Show Figures

Figure 1

6 pages, 273 KiB  
Proceeding Paper
On the Use of Deep Learning Decompositions and Physiological Measurements for the Prediction of Preterm Pregnancies in a Cohort of Patients in Active Labor
by Ejay Nsugbe, José Javier Reyes-Lagos, Dawn Adams, Oluwarotimi Williams Samuel, Mojisola Grace Asogbon and Michael Provost
Eng. Proc. 2022, 27(1), 20; https://doi.org/10.3390/ecsa-9-13192 - 1 Nov 2022
Cited by 1 | Viewed by 1250
Abstract
Preterm pregnancies are one of the leading causes of morbidity and mortality amongst children under the age of five. This is a global issue and has been identified as an area requiring active research. The emphasis now is to identify and develop methods [...] Read more.
Preterm pregnancies are one of the leading causes of morbidity and mortality amongst children under the age of five. This is a global issue and has been identified as an area requiring active research. The emphasis now is to identify and develop methods of predicting the likelihood of preterm birth. This paper uses physiological data from a group of patients in active labor. The dataset contains information about fetal heart rate (FHR) and maternal heart rate (MHR) for all patients and electrohysterogram (EHG) recordings for the measurement of uterine contractions. For the physiological data analysis and associated signal processing, we utilize deep wavelet scattering (DWS). This is an unsupervised decomposition and feature extraction method combining characteristics from deep learning convolutions, as well as the classical wavelet transform, to observe and investigate the extent to which active preterm labor can be accurately identified from an acquired physiological signal, the results of which were compared with the metaheuristic linear series decomposition learner (LSDL). Additional machine learning algorithms are tested on the acquired physiological data to allow for the identification of optimal model architecture for this specific physiological data. Full article
26 pages, 9730 KiB  
Article
Adaptive Filtering for the Maternal Respiration Signal Attenuation in the Uterine Electromyogram
by Daniela Martins, Arnaldo Batista, Helena Mouriño, Sara Russo, Filipa Esgalhado, Catarina R. Palma dos Reis, Fátima Serrano and Manuel Ortigueira
Sensors 2022, 22(19), 7638; https://doi.org/10.3390/s22197638 - 9 Oct 2022
Cited by 2 | Viewed by 2924
Abstract
The electrohysterogram (EHG) is the uterine muscle electromyogram recorded at the abdominal surface of pregnant or non-pregnant woman. The maternal respiration electromyographic signal (MR-EMG) is one of the most relevant interferences present in an EHG. Alvarez (Alv) waves are components of the EHG [...] Read more.
The electrohysterogram (EHG) is the uterine muscle electromyogram recorded at the abdominal surface of pregnant or non-pregnant woman. The maternal respiration electromyographic signal (MR-EMG) is one of the most relevant interferences present in an EHG. Alvarez (Alv) waves are components of the EHG that have been indicated as having the potential for preterm and term birth prediction. The MR-EMG component in the EHG represents an issue, regarding Alv wave application for pregnancy monitoring, for instance, in preterm birth prediction, a subject of great research interest. Therefore, the Alv waves denoising method should be designed to include the interference MR-EMG attenuation, without compromising the original waves. Adaptive filter properties make them suitable for this task. However, selecting the optimal adaptive filter and its parameters is an important task for the success of the filtering operation. In this work, an algorithm is presented for the automatic adaptive filter and parameter selection using synthetic data. The filter selection pool comprised sixteen candidates, from which, the Wiener, recursive least squares (RLS), householder recursive least squares (HRLS), and QR-decomposition recursive least squares (QRD-RLS) were the best performers. The optimized parameters were L = 2 (filter length) for all of them and λ = 1 (forgetting factor) for the last three. The developed optimization algorithm may be of interest to other applications. The optimized filters were applied to real data. The result was the attenuation of the MR-EMG in Alv waves power. For the Wiener filter, power reductions for quartile 1, median, and quartile 3 were found to be −16.74%, −20.32%, and −15.78%, respectively (p-value = 1.31 × 10−12). Full article
(This article belongs to the Special Issue Biosignal Sensing and Analysis for Healthcare Monitoring)
Show Figures

Figure 1

18 pages, 4517 KiB  
Article
Assessment of Features between Multichannel Electrohysterogram for Differentiation of Labors
by Yajun Zhang, Dongmei Hao, Lin Yang, Xiya Zhou, Yiyao Ye-Lin and Yimin Yang
Sensors 2022, 22(9), 3352; https://doi.org/10.3390/s22093352 - 27 Apr 2022
Cited by 7 | Viewed by 2805
Abstract
Electrohysterogram (EHG) is a promising method for noninvasive monitoring of uterine electrical activity. The main purpose of this study was to characterize the multichannel EHG signals to distinguish between term delivery and preterm birth, as well as deliveries within and beyond 24 h. [...] Read more.
Electrohysterogram (EHG) is a promising method for noninvasive monitoring of uterine electrical activity. The main purpose of this study was to characterize the multichannel EHG signals to distinguish between term delivery and preterm birth, as well as deliveries within and beyond 24 h. A total of 219 pregnant women were grouped in two ways: (1) term delivery (TD), threatened preterm labor (TPL) with the outcome of preterm birth (TPL_PB), and TPL with the outcome of term delivery (TPL_TD); (2) EHG recording time to delivery (TTD) ≤ 24 h and TTD > 24 h. Three bipolar EHG signals were analyzed for the 30 min recording. Six EHG features between multiple channels, including multivariate sample entropy, mutual information, correlation coefficient, coherence, direct partial Granger causality, and direct transfer entropy, were extracted to characterize the coupling and information flow between channels. Significant differences were found for these six features between TPL and TD, and between TTD ≤ 24 h and TTD > 24 h. No significant difference was found between TPL_PB and TPL_TD. The results indicated that EHG signals of TD were more regular and synchronized than TPL, and stronger coupling between multichannel EHG signals was exhibited as delivery approaches. In addition, EHG signals propagate downward for the majority of pregnant women regardless of different labors. In conclusion, the coupling and propagation features extracted from multichannel EHG signals could be used to differentiate term delivery and preterm birth and may predict delivery within and beyond 24 h. Full article
(This article belongs to the Special Issue Biosignal Sensing and Processing for Clinical Diagnosis)
Show Figures

Figure 1

13 pages, 3514 KiB  
Article
A Preliminary Exploration of the Placental Position Influence on Uterine Electromyography Using Fractional Modelling
by Müfit Şan, Arnaldo Batista, Sara Russo, Filipa Esgalhado, Catarina R. Palma dos Reis, Fátima Serrano and Manuel Ortigueira
Sensors 2022, 22(5), 1704; https://doi.org/10.3390/s22051704 - 22 Feb 2022
Cited by 5 | Viewed by 2554
Abstract
The uterine electromyogram, also called electrohysterogram (EHG), is the electrical signal generated by uterine contractile activity. The EHG has been considered an expanding technique for pregnancy monitoring and preterm risk evaluation. Data were collected on the abdominal surface. It has been speculated the [...] Read more.
The uterine electromyogram, also called electrohysterogram (EHG), is the electrical signal generated by uterine contractile activity. The EHG has been considered an expanding technique for pregnancy monitoring and preterm risk evaluation. Data were collected on the abdominal surface. It has been speculated the effect of the placenta location on the characteristics of the EHG. In this work, a preliminary exploration method is proposed using the average spectra of Alvarez waves contractions of subjects with anterior and non-anterior placental position as a basis for the triple-dispersion Cole model that provides a best fit for these two cases. This leads to the uterine impedance estimation for these two study cases. Non-linear least square fitting (NLSF) was applied for this modelling process, which produces electric circuit fractional models’ representations. A triple-dispersion Cole-impedance model was used to obtain the uterine impedance curve in a frequency band between 0.1 and 1 Hz. A proposal for the interpretation relating the model parameters and the placental influence on the myometrial contractile action is provided. This is the first report regarding in silico estimation of the uterine impedance for cases involving anterior or non-anterior placental positions. Full article
(This article belongs to the Special Issue Fractional Sensor Fusion and Its Applications)
Show Figures

Figure 1

14 pages, 685 KiB  
Article
Prediction of Preterm Delivery from Unbalanced EHG Database
by Somayeh Mohammadi Far, Matin Beiramvand, Mohammad Shahbakhti and Piotr Augustyniak
Sensors 2022, 22(4), 1507; https://doi.org/10.3390/s22041507 - 15 Feb 2022
Cited by 15 | Viewed by 3265
Abstract
Objective: The early prediction of preterm labor can significantly minimize premature delivery complications for both the mother and infant. The aim of this research is to propose an automatic algorithm for the prediction of preterm labor using a single electrohysterogram (EHG) signal. Method: [...] Read more.
Objective: The early prediction of preterm labor can significantly minimize premature delivery complications for both the mother and infant. The aim of this research is to propose an automatic algorithm for the prediction of preterm labor using a single electrohysterogram (EHG) signal. Method: The proposed method firstly employs empirical mode decomposition (EMD) to split the EHG signal into two intrinsic mode functions (IMFs), then extracts sample entropy (SampEn), the root mean square (RMS), and the mean Teager–Kaiser energy (MTKE) from each IMF to form the feature vector. Finally, the extracted features are fed to a k-nearest neighbors (kNN), support vector machine (SVM), and decision tree (DT) classifiers to predict whether the recorded EHG signal refers to the preterm case. Main results: The studied database consists of 262 term and 38 preterm delivery pregnancies, each with three EHG channels, recorded for 30 min. The SVM with a polynomial kernel achieved the best result, with an average sensitivity of 99.5%, a specificity of 99.7%, and an accuracy of 99.7%. This was followed by DT, with a mean sensitivity of 100%, a specificity of 98.4%, and an accuracy of 98.7%. Significance: The main superiority of the proposed method over the state-of-the-art algorithms that studied the same database is the use of only a single EHG channel without using either synthetic data generation or feature ranking algorithms. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

30 pages, 9448 KiB  
Article
Assessing Velocity and Directionality of Uterine Electrical Activity for Preterm Birth Prediction Using EHG Surface Records
by Franc Jager, Ksenija Geršak, Paula Vouk, Žiga Pirnar, Andreja Trojner-Bregar, Miha Lučovnik and Ana Borovac
Sensors 2020, 20(24), 7328; https://doi.org/10.3390/s20247328 - 20 Dec 2020
Cited by 16 | Viewed by 3725
Abstract
The aim of the present study was to assess the capability of conduction velocity amplitudes and directions of propagation of electrohysterogram (EHG) waves to better distinguish between preterm and term EHG surface records. Using short-time cross-correlation between pairs of bipolar EHG signals (upper [...] Read more.
The aim of the present study was to assess the capability of conduction velocity amplitudes and directions of propagation of electrohysterogram (EHG) waves to better distinguish between preterm and term EHG surface records. Using short-time cross-correlation between pairs of bipolar EHG signals (upper and lower, left and right), the conduction velocities and their directions were estimated using preterm and term EHG records of the publicly available Term–Preterm EHG DataSet with Tocogram (TPEHGT DS) and for different frequency bands below and above 1.0 Hz, where contractions and the influence of the maternal heart rate on the uterus, respectively, are expected. No significant or preferred continuous direction of propagation was found in any of the non-contraction (dummy) or contraction intervals; however, on average, a significantly lower percentage of velocity vectors was found in the vertical direction, and significantly higher in the horizontal direction, for preterm dummy intervals above 1.0 Hz. The newly defined features—the percentages of velocities in the vertical and horizontal directions, in combination with the sample entropy of the EHG signal recorded in the vertical direction, obtained from dummy intervals above 1.0 Hz—showed the highest classification accuracy of 86.8% (AUC=90.3%) in distinguishing between preterm and term EHG records of the TPEHGT DS. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

13 pages, 3808 KiB  
Article
Phase Entropy Analysis of Electrohysterographic Data at the Third Trimester of Human Pregnancy and Active Parturition
by José Javier Reyes-Lagos, Adriana Cristina Pliego-Carrillo, Claudia Ivette Ledesma-Ramírez, Miguel Ángel Peña-Castillo, María Teresa García-González, Gustavo Pacheco-López and Juan Carlos Echeverría
Entropy 2020, 22(8), 798; https://doi.org/10.3390/e22080798 - 22 Jul 2020
Cited by 11 | Viewed by 3740
Abstract
Phase Entropy (PhEn) was recently introduced for evaluating the nonlinear features of physiological time series. PhEn has been demonstrated to be a robust approach in comparison to other entropy-based methods to achieve this goal. In this context, the present study aimed [...] Read more.
Phase Entropy (PhEn) was recently introduced for evaluating the nonlinear features of physiological time series. PhEn has been demonstrated to be a robust approach in comparison to other entropy-based methods to achieve this goal. In this context, the present study aimed to analyze the nonlinear features of raw electrohysterogram (EHG) time series collected from women at the third trimester of pregnancy (TT) and later during term active parturition (P) by PhEn. We collected 10-min longitudinal transabdominal recordings of 24 low-risk pregnant women at TT (from 35 to 38 weeks of pregnancy) and P (>39 weeks of pregnancy). We computed the second-order difference plots (SODPs) for the TT and P stages, and we evaluated the PhEn by modifying the k value, a coarse-graining parameter. Our results pointed out that PhEn in TT is characterized by a higher likelihood of manifesting nonlinear dynamics compared to the P condition. However, both conditions maintain percentages of nonlinear series higher than 66%. We conclude that the nonlinear features appear to be retained for both stages of pregnancy despite the uterine and cervical reorganization process that occurs in the transition from the third trimester to parturition. Full article
(This article belongs to the Special Issue Entropy and Nonlinear Dynamics in Medicine, Health, and Life Sciences)
Show Figures

Figure 1

15 pages, 2727 KiB  
Article
Robust Characterization of the Uterine Myoelectrical Activity in Different Obstetric Scenarios
by Javier Mas-Cabo, Yiyao Ye-Lin, Javier Garcia-Casado, Alba Díaz-Martinez, Alfredo Perales-Marin, Rogelio Monfort-Ortiz, Alba Roca-Prats, Ángel López-Corral and Gema Prats-Boluda
Entropy 2020, 22(7), 743; https://doi.org/10.3390/e22070743 - 5 Jul 2020
Cited by 23 | Viewed by 3224
Abstract
Electrohysterography (EHG) has been shown to provide relevant information on uterine activity and could be used for predicting preterm labor and identifying other maternal fetal risks. The extraction of high-quality robust features is a key factor in achieving satisfactory prediction systems from EHG. [...] Read more.
Electrohysterography (EHG) has been shown to provide relevant information on uterine activity and could be used for predicting preterm labor and identifying other maternal fetal risks. The extraction of high-quality robust features is a key factor in achieving satisfactory prediction systems from EHG. Temporal, spectral, and non-linear EHG parameters have been computed to characterize EHG signals, sometimes obtaining controversial results, especially for non-linear parameters. The goal of this work was to assess the performance of EHG parameters in identifying those robust enough for uterine electrophysiological characterization. EHG signals were picked up in different obstetric scenarios: antepartum, including women who delivered on term, labor, and post-partum. The results revealed that the 10th and 90th percentiles, for parameters with falling and rising trends as labor approaches, respectively, differentiate between these obstetric scenarios better than median analysis window values. Root-mean-square amplitude, spectral decile 3, and spectral moment ratio showed consistent tendencies for the different obstetric scenarios as well as non-linear parameters: Lempel–Ziv, sample entropy, spectral entropy, and SD1/SD2 when computed in the fast wave high bandwidth. These findings would make it possible to extract high quality and robust EHG features to improve computer-aided assessment tools for pregnancy, labor, and postpartum progress and identify maternal fetal risks. Full article
Show Figures

Figure 1

16 pages, 1754 KiB  
Article
Electrohysterogram for ANN-Based Prediction of Imminent Labor in Women with Threatened Preterm Labor Undergoing Tocolytic Therapy
by J. Mas-Cabo, G. Prats-Boluda, J. Garcia-Casado, J. Alberola-Rubio, R. Monfort-Ortiz, C. Martinez-Saez, A. Perales and Y. Ye-Lin
Sensors 2020, 20(9), 2681; https://doi.org/10.3390/s20092681 - 8 May 2020
Cited by 18 | Viewed by 3365
Abstract
Threatened preterm labor (TPL) is the most common cause of hospitalization in the second half of pregnancy and entails high costs for health systems. Currently, no reliable labor proximity prediction techniques are available for clinical use. Regular checks by uterine electrohysterogram (EHG) for [...] Read more.
Threatened preterm labor (TPL) is the most common cause of hospitalization in the second half of pregnancy and entails high costs for health systems. Currently, no reliable labor proximity prediction techniques are available for clinical use. Regular checks by uterine electrohysterogram (EHG) for predicting preterm labor have been widely studied. The aim of the present study was to assess the feasibility of predicting labor with a 7- and 14-day time horizon in TPL women, who may be under tocolytic treatment, using EHG and/or obstetric data. Based on 140 EHG recordings, artificial neural networks were used to develop prediction models. Non-linear EHG parameters were found to be more reliable than linear for differentiating labor in under and over 7/14 days. Using EHG and obstetric data, the <7- and <14-day labor prediction models achieved an AUC in the test group of 87.1 ± 4.3% and 76.2 ± 5.8%, respectively. These results suggest that EHG can be reliable for predicting imminent labor in TPL women, regardless of the tocolytic therapy stage. This paves the way for the development of diagnostic tools to help obstetricians make better decisions on treatments, hospital stays and admitting TPL women, and can therefore reduce costs and improve maternal and fetal wellbeing. Full article
(This article belongs to the Special Issue Biomedical Signal Processing)
Show Figures

Figure 1

Back to TopTop