Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (7)

Search Parameters:
Keywords = AISI 316L biomaterial

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 28047 KiB  
Article
Adhesion and Activation of Blood Platelets on Laser-Structured Surfaces of Biomedical Metal Alloys
by Marta Kamińska, Aleksandra Jastrzębska, Magdalena Walkowiak-Przybyło, Marta Walczyńska, Piotr Komorowski and Bogdan Walkowiak
J. Funct. Biomater. 2023, 14(9), 478; https://doi.org/10.3390/jfb14090478 - 18 Sep 2023
Cited by 4 | Viewed by 2052
Abstract
The laser surface modification of metallic implants presents a promising alternative to other surface modification techniques. A total of four alloyed metallic biomaterials were used for this study: medical steel (AISI 316L), cobalt–chromium–molybdenum alloy (CoCrMo) and titanium alloys (Ti6Al4V and Ti6Al7Nb). Samples of [...] Read more.
The laser surface modification of metallic implants presents a promising alternative to other surface modification techniques. A total of four alloyed metallic biomaterials were used for this study: medical steel (AISI 316L), cobalt–chromium–molybdenum alloy (CoCrMo) and titanium alloys (Ti6Al4V and Ti6Al7Nb). Samples of metallic biomaterials after machining were subjected to polishing or laser modification in two different versions. The results of surface modification were documented using SEM imaging and roughness measurement. After modification, the samples were sterilized with dry hot air, then exposed to citrate blood, washed with PBS buffer, fixed with glutaraldehyde, sputtered with a layer of gold and imaged using SEM to enable the quantification of adhered, activated and aggregated platelets on the surface of biomaterial samples. The average total number, counted in the field of view, of adhered platelets on the surfaces of the four tested biomaterials, regardless of the type of modification, did not differ statistically significantly (66 ± 81, 67 ± 75, 61 ± 70 and 57 ± 61 for AISI 316L, CoCrMo, Ti6Al4V and Ti6Al7Nb, respectively) and the average number of platelet aggregates was statistically significantly higher (p < 0.01) on the surfaces of AISI 316L medical steel (42 ± 53) and of the CoCrMo alloy (42 ± 52) compared to the surfaces of the titanium alloys Ti6Al4V (33 ± 39) and Ti6Al7Nb (32 ± 37). Remaining blood after contact was used to assess spontaneous platelet activation and aggregation in whole blood by flow cytometry. An in-depth analysis conducted on the obtained results as a function of the type of modification indicates small but statistically significant differences in the interaction of platelets with the tested surfaces of metallic biomaterials. Full article
(This article belongs to the Special Issue Metals and Alloys for Biomedical Application)
Show Figures

Figure 1

11 pages, 3571 KiB  
Article
The Effect of Sensitization on the Susceptibility of AISI 316L Biomaterial to Pitting Corrosion
by Viera Zatkalíková, Milan Uhríčik, Lenka Markovičová, Lucia Pastierovičová and Lenka Kuchariková
Materials 2023, 16(16), 5714; https://doi.org/10.3390/ma16165714 - 21 Aug 2023
Cited by 5 | Viewed by 1824
Abstract
Due to the combination of high corrosion resistance and suitable mechanical properties, AISI 316L stainless steel is extensively used as the biomaterial for surgical implants. However, heat exposure in inappropriate temperatures can cause its sensitization accompanied by chromium depletion along the grain boundaries. [...] Read more.
Due to the combination of high corrosion resistance and suitable mechanical properties, AISI 316L stainless steel is extensively used as the biomaterial for surgical implants. However, heat exposure in inappropriate temperatures can cause its sensitization accompanied by chromium depletion along the grain boundaries. This study deals with an assessment of the susceptibility of sensitized AISI 316L biomaterial to pitting under conditions simulating the internal environment of the human body (Hank’s balanced salt solution, 37 ± 0.5 °C). The resistance to pitting corrosion is tested by the potentiodynamic polarization and by the 50-day exposure immersion test. Corrosion damage after the exposure immersion test is evaluated in the specimens’ cross-sections by optical microscope and SEM. Despite passive behavior in potentiodynamic polarization and shallow, slight corrosion damage observed after exposure, the sensitized AISI 316L biomaterial could represent a risk, especially in long-term implantation even after the chemical removal of high-temperature oxides. Full article
(This article belongs to the Special Issue Research on Metallic Implant Biomaterials)
Show Figures

Figure 1

13 pages, 3344 KiB  
Article
Plasma Electrolytic Polishing—An Ecological Way for Increased Corrosion Resistance in Austenitic Stainless Steels
by Viera Zatkalíková, Štefan Podhorský, Milan Štrbák, Tatiana Liptáková, Lenka Markovičová and Lenka Kuchariková
Materials 2022, 15(12), 4223; https://doi.org/10.3390/ma15124223 - 14 Jun 2022
Cited by 14 | Viewed by 3678
Abstract
Plasma electrolytic polishing (PEP) is an environment-friendly alternative to the conventional electrochemical polishing (EP), giving optimal surface properties and improved corrosion resistance with minimum energy and time consumption, which leads to both economic and environmental benefits. This paper is focused on the corrosion [...] Read more.
Plasma electrolytic polishing (PEP) is an environment-friendly alternative to the conventional electrochemical polishing (EP), giving optimal surface properties and improved corrosion resistance with minimum energy and time consumption, which leads to both economic and environmental benefits. This paper is focused on the corrosion behavior of PEP treated AISI 316L stainless steel widely used as a biomaterial. Corrosion resistance of plasma electrolytic polished surfaces without/with chemical pretreatment (acid cleaning) is evaluated and compared with original non-treated (as received) surfaces by three independent test methods: electrochemical impedance spectroscopy (EIS), potentiodynamic polarization (PP), and exposure immersion test. All corrosion tests are carried out in the 0.9 wt.% NaCl solution at a temperature of 37 ± 0.5 °C to simulate the internal environment of a human body. The quality of tested surfaces is also characterized by optical microscopy and by the surface roughness parameters. The results obtained indicated high corrosion resistance of PEP treated surfaces also without chemical pretreatment, which increases the ecological benefits of PEP technology. Full article
(This article belongs to the Special Issue Quality, Microstructure and Properties of Metal Alloys)
Show Figures

Figure 1

19 pages, 19251 KiB  
Article
Microstructure and Mechanical Properties of Modified 316L Stainless Steel Alloy for Biomedical Applications Using Powder Metallurgy
by Sadaqat Ali, Muhammad Irfan, Usama Muhammad Niazi, Ahmad Majdi Abdul Rani, Ahmad Rashedi, Saifur Rahman, Muhammad Kamal Asif Khan, Mabkhoot A. Alsaiari, Stanislaw Legutko, Jana Petrů and Antonin Trefil
Materials 2022, 15(8), 2822; https://doi.org/10.3390/ma15082822 - 12 Apr 2022
Cited by 44 | Viewed by 4264
Abstract
AISI 316L stainless steel (SS) is one of the extensively used biomaterials to produce implants and medical devices. It provides a low-cost solution with ample mechanical properties, corrosion resistance, and biocompatibility compared to its counterpart materials. However, the implants made of this material [...] Read more.
AISI 316L stainless steel (SS) is one of the extensively used biomaterials to produce implants and medical devices. It provides a low-cost solution with ample mechanical properties, corrosion resistance, and biocompatibility compared to its counterpart materials. However, the implants made of this material are subjected to a short life span in human physiological conditions leading to the leaching of metal ions, thus limiting its use as a biomaterial. In this research, the addition of boron, titanium, and niobium with varying concentrations in the SS matrix has been explored. This paper explores the impact of material composition on modified SS alloy’s physical and mechanical properties. The study’s outcomes specify that the microhardness increases for all the alloy compositions, with a maximum increase of 64.68% for the 2 wt.% niobium added SS alloy. On the other hand, the tensile strength decreased to 297.40 MPa for the alloy containing 0.25 wt.% boron and 2 wt.% titanium additions compared to a tensile strength of 572.50 MPa for pure SS. The compression strength increased from 776 MPa for pure SS to 1408 MPa for the alloy containing niobium and titanium additions in equal concentrations. Full article
(This article belongs to the Section Manufacturing Processes and Systems)
Show Figures

Figure 1

10 pages, 4829 KiB  
Article
Corrosion Resistance of AISI 316L Stainless Steel Biomaterial after Plasma Immersion Ion Implantation of Nitrogen
by Viera Zatkalíková, Juraj Halanda, Dušan Vaňa, Milan Uhríčik, Lenka Markovičová, Milan Štrbák and Lenka Kuchariková
Materials 2021, 14(22), 6790; https://doi.org/10.3390/ma14226790 - 10 Nov 2021
Cited by 11 | Viewed by 2772
Abstract
Plasma immersion ion implantation (PIII) of nitrogen is low-temperature surface technology which enables the improvement of tribological properties without a deterioration of the corrosion behavior of austenitic stainless steels. In this paper the corrosion properties of PIII-treated AISI 316L stainless steel surfaces are [...] Read more.
Plasma immersion ion implantation (PIII) of nitrogen is low-temperature surface technology which enables the improvement of tribological properties without a deterioration of the corrosion behavior of austenitic stainless steels. In this paper the corrosion properties of PIII-treated AISI 316L stainless steel surfaces are evaluated by electrochemical impedance spectroscopy (EIS), potentiodynamic polarization (PP) and exposure immersion tests (all carried out in the 0.9 wt. % NaCl solution at 37 ± 0.5 °C) and compared with a non-treated surface. Results of the three performed independent corrosion tests consistently confirmed a significant increase in the corrosion resistance after two doses of PIII nitriding. Full article
(This article belongs to the Special Issue Quality, Microstructure and Properties of Metal Alloys)
Show Figures

Figure 1

17 pages, 3140 KiB  
Article
Comprehensive Biological Evaluation of Biomaterials Used in Spinal and Orthopedic Surgery
by Piotr Komorowski, Małgorzata Siatkowska, Marta Kamińska, Witold Jakubowski, Marta Walczyńska, Magdalena Walkowiak-Przybyło, Witold Szymański, Katarzyna Piersa, Patryk Wielowski, Paulina Sokołowska, Kamila Białkowska, Krzysztof Makowski, Marcin Elgalal, Agnieszka Kierzkowska, Lechosław Ciupik and Bogdan Walkowiak
Materials 2020, 13(21), 4769; https://doi.org/10.3390/ma13214769 - 26 Oct 2020
Cited by 5 | Viewed by 2994
Abstract
Biological acceptance is one of the most important aspects of a biomaterial and forms the basis for its clinical use. The aim of this study was a comprehensive biological evaluation (cytotoxicity test, bacterial colonization test, blood platelets adhesion test and transcriptome and proteome [...] Read more.
Biological acceptance is one of the most important aspects of a biomaterial and forms the basis for its clinical use. The aim of this study was a comprehensive biological evaluation (cytotoxicity test, bacterial colonization test, blood platelets adhesion test and transcriptome and proteome analysis of Saos-2 cells after contact with surface of the biomaterial) of biomaterials used in spinal and orthopedic surgery, namely, Ti6Al4V ELI (Extra Low Interstitials), its modified version obtained as a result of melting by electron beam technology (Ti6Al4V ELI-EBT), polyether ether ketone (PEEK) and polished medical steel American Iron and Steel Institute (AISI) 316L (the reference material). Biological tests were carried out using the osteoblasts-like cells (Saos-2, ATCC HTB-85) and bacteria Escherichia coli (DH5α). Results showed lack of cytotoxicity of all materials and the surfaces of both Ti6Al4V ELI and PEEK exhibit a significantly higher resistance to colonization with E. coli cells, while the more porous surface of the same titanium alloy produced by electron beam technology (EBT) is more susceptible to microbial colonization than the control surface of polished medical steel. None of the tested materials showed high toxicity in relation to E. coli cells. Susceptibility to platelet adhesion was very high for polished medical steel AISI 316L, whilst much lower for the other biomaterials and can be ranked from the lowest to the highest as follows: PEEK < Ti6Al4V ELI < Ti6Al4V ELI-EBT. The number of expressed genes in Saos-2 cells exposed to contact with the examined biomaterials reached 9463 genes in total (ranging from 8455 genes expressed in cells exposed to ELI to 9160 genes in cells exposed to PEEK). Whereas the number of differentially expressed proteins detected on two-dimensional electrophoresis gels in Saos-2 cells after contact with the examined biomaterials was 141 for PEEK, 223 for Ti6Al4V ELI and 133 for Ti6Al4V ELI-EBT. Finally, 14 proteins with altered expression were identified by mass spectrometry. In conclusion, none of the tested biomaterials showed unsatisfactory levels of cytotoxicity. The gene and protein expression analysis, that represents a completely new approach towards characterization of these biomaterials, showed that the polymer PEEK causes much more intense changes in gene and protein expression and thus influences cell metabolism. Full article
(This article belongs to the Section Biomaterials)
Show Figures

Figure 1

17 pages, 437 KiB  
Article
Biomaterial Studies on AISI 316L Stainless Steel after Magnetoelectropolishing
by Tadeusz Hryniewicz, Krzysztof Rokosz and Massimiliano Filippi
Materials 2009, 2(1), 129-145; https://doi.org/10.3390/ma2010129 - 11 Mar 2009
Cited by 59 | Viewed by 16600
Abstract
The polarisation characteristics of the electropolishing process in a magnetic field (MEP – magnetoelectropolishing), in comparison with those obtained under standard/conventional process (EP) conditions, have been obtained. The occurrence of an EP plateau has been observed in view of the optimization of MEP [...] Read more.
The polarisation characteristics of the electropolishing process in a magnetic field (MEP – magnetoelectropolishing), in comparison with those obtained under standard/conventional process (EP) conditions, have been obtained. The occurrence of an EP plateau has been observed in view of the optimization of MEP process. Up-to-date stainless steel surface studies always indicated some amount of free-metal atoms apart from the detected oxides and hydroxides. Such a morphology of the surface film usually affects the thermodynamic stability and corrosion resistance of surface oxide layer and is one of the most important features of stainless steels. With this new MEP process we can improve metal surface properties by making the stainless steel more resistant to halides encountered in a variety of environments. Furthermore, in this paper the stainless steel surface film study results have been presented. The results of the corrosion research carried out by the authors on the behaviour of the most commonly used material - medical grade AISI 316L stainless steel both in Ringer’s body fluid and in aqueous 3% NaCl solution have been investigated and presented earlier elsewhere, though some of these results, concerning the EIS Nyquist plots and polarization curves are also revealed herein. In this paper an attempt to explain this peculiar performance of 316L stainless steel has been undertaken. The SEM studies, Auger electron spectroscopy (AES) and X-ray photoelectron spectroscopy (XPS) were performed on 316L samples after three treatments: MP – abrasive polishing (800 grit size), EP – conventional electrolytic polishing, and MEP – magnetoelectropolishing. It has been found that the proposed magnetoelectropolishing (MEP) process considerably modifies the morphology and the composition of the surface film, thus leading to improved corrosion resistance of the studied 316L SS. Full article
Show Figures

Figure 1

Back to TopTop