The Validity and Reliability of the My Jump Lab App for the Measurement of Vertical Jump Performance Using Artificial Intelligence
Abstract
:1. Introduction
2. Materials and Methods
2.1. Experimental Approach to the Problem
2.2. Subjects
2.3. Procedures and Instruments
2.4. Statistical Analyses
3. Results
3.1. Concurrent Validity and Bias Determination
3.2. Reliability
3.3. Bland–Altman Analysis
4. Discussion
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Fry, A.C. The Role of Resistance Exercise Intensity on Muscle Fibre Adaptations. Sports Med. 2004, 34, 663–679. [Google Scholar] [CrossRef] [PubMed]
- Folland, J.P.; Williams, A.G. The Adaptations to Strength Training. Sports Med. 2007, 37, 145–168. [Google Scholar] [CrossRef] [PubMed]
- Stamatakis, E.; Lee, I.-M.; Bennie, J.; Freeston, J.; Hamer, M.; O’Donovan, G.; Ding, D.; Bauman, A.; Mavros, Y. Does Strength Promoting Exercise Confer Unique Health Benefits? A Pooled Analysis of Eleven Population Cohorts with All-Cause, Cancer, and Cardiovascular Mortality Endpoints. Am. J. Epidemiol. 2018, 187, 1102–1112. [Google Scholar] [CrossRef] [PubMed]
- Morin, J.B.; Samozino, P. Interpreting Power-Force-Velocity Profiles for Individualized and Specific Training. Int. J. Sports Physiol. Perform. 2016, 11, 267–272. [Google Scholar] [CrossRef]
- Cormack, S.J.; Newton, R.U.; McGuigan, M.R. Neuromuscular and Endocrine Responses of Elite Players to an Australian Rules Football Match. Int. J. Sports Physiol. Perform. 2008, 3, 359–374. [Google Scholar] [CrossRef]
- Bishop, C.; Turner, A.; Jordan, M.; Harry, J.; Loturco, I.; Lake, J.; Comfort, P. A Framework to Guide Practitioners for Selecting Metrics during the Countermovement and Drop Jump Tests. Strength Cond. J. 2022, 44, 95–103. [Google Scholar] [CrossRef]
- Kozinc, Ž.; Žitnik, J.; Smajla, D.; Šarabon, N. The Difference between Squat Jump and Countermovement Jump in 770 Male and Female Participants from Different Sports. Eur. J. Sport Sci. 2022, 22, 985–993. [Google Scholar] [CrossRef]
- Asimakidis, N.D.; Bishop, C.J.; Beato, M.; Mukandi, I.N.; Kelly, A.L.; Weldon, A.; Turner, A.N. A Survey into the Current Fitness Testing Practices of Elite Male Soccer Practitioners: From Assessment to Communicating Results. Front. Physiol. 2024, 15, 1376047. [Google Scholar] [CrossRef]
- Samozino, P.; Rejc, E.; Di Prampero, P.E.; Belli, A.; Morin, J.B. Optimal Force-Velocity Profile in Ballistic Movements—Altius: Citius or Fortius? Med. Sci. Sports Exerc. 2012, 44, 313–322. [Google Scholar] [CrossRef]
- Nibali, M.L.; Chapman, D.W.; Robergs, R.A.; Drinkwater, E.J. A Rationale for Assessing the Lower-Body Power Profile in Team Sport Athletes. J. Strength Cond. Res. 2013, 27, 388–397. [Google Scholar] [CrossRef]
- Agar-Newman, D.J.; Tsai, M.-C.; Klimstra, M. The Validity of Applying a Simple Three-Factor Computational Model to Calculate Force, Power, and Speed Using Hexagonal Bar Jumps. J. Strength Cond. Res. 2022, 36, 2108–2114. [Google Scholar] [CrossRef] [PubMed]
- Samozino, P.; Morin, J.-B.; Hintzy, F.; Belli, A. A Simple Method for Measuring Force, Velocity and Power Output during Squat Jump. J. Biomech. 2008, 41, 2940–2945. [Google Scholar] [CrossRef] [PubMed]
- Montalvo, S.; Gonzalez, M.P.; Dietze-Hermosa, M.S.; Eggleston, J.D.; Dorgo, S. Common Vertical Jump and Reactive Strength Index Measuring Devices: A Validity and Reliability Analysis. J. Strength Cond. Res. 2021, 35, 1234–1243. [Google Scholar] [CrossRef] [PubMed]
- Balsalobre-Fernández, C.; Glaister, M.; Lockey, R.A. The Validity and Reliability of an IPhone App for Measuring Vertical Jump Performance. J. Sports Sci. 2015, 33, 1574–1579. [Google Scholar] [CrossRef] [PubMed]
- Martínez-Martí, F.; González-Montesinos, J.; Morales, D.; Santos, J.; Castro-Piñero, J.; Carvajal, M.; Palma, A. Validation of Instrumented Insoles for Measuring Height in Vertical Jump. Int. J. Sports Med. 2016, 37, 374–381. [Google Scholar] [CrossRef] [PubMed]
- Pueo, B.; Lopez, J.J.; Jimenez-Olmedo, J.M. Audio-Based System for Automatic Measurement of Jump Height in Sports Science. Sensors 2019, 19, 2543. [Google Scholar] [CrossRef]
- Balsalobre-Fernández, C.; Tejero-González, C.M.; del Campo-Vecino, J.; Bavaresco, N. The Concurrent Validity and Reliability of a Low-Cost, High-Speed Camera-Based Method for Measuring the Flight Time of Vertical Jumps. J. Strength Cond. Res. 2014, 28, 528–533. [Google Scholar] [CrossRef]
- Sharp, A.P.; Cronin, J.B.; Neville, J. Using Smartphones for Jump Diagnostics: A Brief Review of the Validity and Reliability of the My Jump App. Strength Cond. J. 2019, 41, 96–107. [Google Scholar] [CrossRef]
- Bishop, C.; Jarvis, P.; Turner, A.; Balsalobre-Fernandez, C. Validity and Reliability of Strategy Metrics to Assess Countermovement Jump Performance Using the Newly Developed My Jump Lab Smartphone Application. J. Hum. Kinet. 2022, 83, 185–195. [Google Scholar] [CrossRef]
- Stojiljković, N.; Stanković, D.; Pelemiš, V.; Čokorilo, N.; Olanescu, M.; Peris, M.; Suciu, A.; Plesa, A. Validity and Reliability of the My Jump 2 App for Detecting Interlimb Asymmetry in Young Female Basketball Players. Front. Sports Act. Living 2024, 6, 1362646. [Google Scholar] [CrossRef]
- Wirtz, S.; Julian, R.; Schmale, R.; Eils, E. Concurrent Validity and Reliability of In-Field Vertical Jump Performance Measures on Sand Surfaces. J. Strength Cond. Res. 2024, 38, 687–693. [Google Scholar] [CrossRef] [PubMed]
- Pueo, B.; Hopkins, W.; Penichet-Tomas, A.; Jimenez-Olmedo, J. Accuracy of Flight Time and Countermovement-Jump Height Estimated from Videos at Different Frame Rates with MyJump. Biol. Sport 2023, 40, 595–601. [Google Scholar] [CrossRef] [PubMed]
- Bogataj, Š.; Pajek, M.; Hadžić, V.; Andrašić, S.; Padulo, J.; Trajković, N. Validity, Reliability, and Usefulness of My Jump 2 App for Measuring Vertical Jump in Primary School Children. Int. J. Environ. Res. Public Health 2020, 17, 3708. [Google Scholar] [CrossRef] [PubMed]
- Coswig, V.; Silva, A.D.A.C.E.; Barbalho, M.; De Faria, F.R.; Nogueira, C.D.; Borges, M.; Buratti, J.R.; Vieira, I.B.; Román, F.J.L.; Gorla, J.I. Assessing the Validity of the MyJump2 App for Measuring Different Jumps in Professional Cerebral Palsy Football Players: An Experimental Study. JMIR mHealth uHealth 2019, 7, e11099. [Google Scholar] [CrossRef]
- Cruvinel-Cabral, R.M.; Oliveira-Silva, I.; Medeiros, A.R.; Claudino, J.G.; Jiménez-Reyes, P.; Boullosa, D.A. The Validity and Reliability of the “ My Jump App” for Measuring Jump Height of the Elderly. PeerJ 2018, 6, e5804. [Google Scholar] [CrossRef]
- Şentürk, D.; Yüksel, O.; Akyildiz, Z. The Concurrent Validity and Reliability of the My Jump Lab Smartphone App for the Real-Time Measurement of Vertical Jump Performance. Proc. Inst. Mech. Eng. Part P J. Sports Eng. Technol. 2024, 17543371241246440. [Google Scholar] [CrossRef]
- Tan, E.C.H.; Weng Onn, S.; Montalvo, S. Measuring Vertical Jump Height With Artificial Intelligence Through a Cell Phone: A Validity and Reliability Report. J. Strength Cond. Res. 2024, 38, e529–e533. [Google Scholar] [CrossRef]
- Balsalobre-Fernández, C. Real Time Estimation of Vertical Jump Height with a Markerless Motion Capture Smartphone App: A Proof-of-Concept Case Study. Proc. Inst. Mech. Eng. Part P J. Sports Eng. Technol. 2024, 17543371241227817. [Google Scholar] [CrossRef]
- Rhea, M.R. Determining the Magnitude of Treatment Effects in Strength Training Research Through the Use of the Effect Size. J. Strength Cond. Res. 2004, 18, 918. [Google Scholar] [CrossRef]
- Naik, B.T.; Hashmi, M.F.; Bokde, N.D. A Comprehensive Review of Computer Vision in Sports: Open Issues, Future Trends and Research Directions. Appl. Sci. 2022, 12, 4429. [Google Scholar] [CrossRef]
- Khanal, S.R.; Paulino, D.; Sampaio, J.; Barroso, J.; Reis, A.; Filipe, V. A Review on Computer Vision Technology for Physical Exercise Monitoring. Algorithms 2022, 15, 444. [Google Scholar] [CrossRef]
- Barris, S.; Button, C. A Review of Vision-Based Motion Analysis in Sport. Sports Med. 2008, 38, 1025–1043. [Google Scholar] [CrossRef] [PubMed]
- Glatthorn, J.F.; Gouge, S.; Nussbaumer, S.; Stauffacher, S.; Impellizzeri, F.M.; Maffiuletti, N.A. Validity and Reliability of Optojump Photoelectric Cells for Estimating Vertical Jump Height. J. Strength Cond. Res. 2011, 25, 556–560. [Google Scholar] [CrossRef] [PubMed]
- Haynes, T.; Bishop, C.; Antrobus, M.; Brazier, J. The Validity and Reliability of the My Jump 2 App for Measuring the Reactive Strength Index and Drop Jump Performance. J. Sports Med. Phys. Fitness 2019, 59, 253–258. [Google Scholar] [CrossRef] [PubMed]
- Barbalho, M.; Kleiner, A.F.R.; Callegari, B.; de Lima, R.C.; da Silva Souza, G.; de Athayde Costa e Silva, A.; Coswig, V.S. Assessing Interlimb Jump Asymmetry in Young Soccer Players: The My Jump 2 App. Int. J. Sports Physiol. Perform. 2021, 16, 19–27. [Google Scholar] [CrossRef]
- Whiteley, I.; Sideris, V.; Kotsifaki, R.; King, E.; Whiteley, R. The MyJump App Is a Valid Method of Assessing and Classifying Limb Symmetry During Recovery from Anterior Cruciate Ligament Reconstruction. Int. J. Sports Phys. Ther. 2023, 18, 1156–1165. [Google Scholar] [CrossRef]
- Rogers, S.A.; Hassmén, P.; Hunter, A.; Alcock, A.; Crewe, S.T.; Strauts, J.A.; Gilleard, W.L.; Weissensteiner, J.R. The Validity and Reliability of the MyJump2 Application to Assess Vertical Jumps in Trained Junior Athletes. Meas. Phys. Educ. Exerc. Sci. 2019, 23, 69–77. [Google Scholar] [CrossRef]
Variable | Force Platform | My Jump Lab | r (95% CI) | Mean Difference (±SD) | d (95% CI) |
---|---|---|---|---|---|
Height (cm) | |||||
Pooled | 22.5 ± 9.2 | 23.4 ± 9.8 | 0.984 (0.977–0.988) | 1.6 ± 1.1 | 0.483 (0.307–0.657) |
Unloaded jump | 33.3 ± 10.2 | 34.7 ± 10.6 | 0.982 (0.963–0.991) | 2.0 ± 1.3 | 0.675 (0.286–1.055) * |
Load 1 | 21.6 ± 7.1 | 22.2 ± 8.0 | 0.974 (0.950–0.987) | 1.6 ± 1.2 | 0.340 (0.002–0.674) |
Load 2 | 19.2 ± 5.4 | 20.2 ± 5.7 | 0.971 (0.943–0.985) | 1.4 ± 0.9 | 0.700 (0.331–1.061) * |
Load 3 | 17.0 ± 3.8 | 17.6 ± 4.2 | 0.910 (0.830–0.954) | 1.4 ± 1.2 | 0.301 (−0.035–0.633) |
Mean propulsive force (N/kg) | |||||
Pooled | 22.3 ± 3.7 | 22.7 ± 3.8 | 0.979 (0.971–0.985) | 0.68 ± 0.49 | 0.471 (0.296–0.645) |
Unloaded jump | 19.64 ± 4.70 | 20.08 ± 5.00 | 0.993 (0.987–0.997) | 0.67 ± 0.45 | 0.690 (0.321–1.050) * |
Load 1 | 21.73 ± 3.47 | 22.01 ± 3.71 | 0.980 (0.960–0.990) | 0.68 ± 0.44 | 0.360 (0.020–0.694) |
Load 2 | 22.70 ± 3.57 | 23.15 ± 3.62 | 0.984 (0.968–0.992) | 0.68 ± 0.45 | 0.690 (0.322–1.051) * |
Load 3 | 23.73 ± 3.84 | 23.96 ± 3.81 | 0.970 (0.941–0.985) | 0.73 ± 0.62 | 0.253 (−0.081–0.583) |
Mean propulsive velocity (m/s) | |||||
Pooled | 1.03 ± 0.2 | 1.05 ± 0.22 | 0.981 (0.973–0.986) | 0.03 ± 0.02 | 0.432 (0.258–0.605) |
Unloaded jump | 1.12 ± 0.44 | 1.14 ± 0.20 | 0.997 (0.994–0.999) | 0.03 ± 0.02 | 0.644 (0.281–1.000) * |
Load 1 | 1.01 ± 0.17 | 1.02 ± 0.20 | 0.972 (0.946–0.986) | 0.04 ± 0.03 | 0.241 (−0.093–0.570) |
Load 2 | 0.96 ± 0.13 | 0.98 ± 0.14 | 0.969 (0.939–0.984) | 0.04 ± 0.02 | 0.660 (0.295–1.017) * |
Load 3 | 0.90 ± 0.10 | 0.92 ± 0.11 | 0.913 (0.836–0.955) | 0.03 ± 0.02 | 0.288 (−0.047–0.620) |
Mean propulsive power (W/kg) | |||||
Pooled | 23.3 ± 6.8 | 24.1 ± 7.3 | 0.971 (0.960–0.979) | 1.56 ± 1.14 | 0.485 (0.309–0.659) |
Unloaded jump | 23.91 ± 11.2 | 25.01 ± 11.95 | 0.991 (0.983–0.996) | 1.72 ± 1.19 | 0.663 (0.298–1.021) * |
Load 1 | 22.55 ± 6.84 | 23.21 ± 7.53 | 0.975 (0.952–0.987) | 1.56 ± 1.02 | 0.380 (0.039–0.715) |
Load 2 | 22.22 ± 6.12 | 23.21 ± 6.29 | 0.974 (0.950–0.987) | 1.42 ± 0.96 | 0.699 (0.330–1.060) * |
Load 3 | 21.86 ± 5.52 | 22.40 ± 5.62 | 0.933 (0.872–0.966) | 1.60 ± 1.35 | 0.264 (−0.070–0.595) |
Variable | CV (%) | Cronbach’s α |
---|---|---|
Force platform | ||
Height (cm) | 5.0 ± 4.1 | 0.985 |
Mean propulsive force (N/kg) | 2.2 ± 1.9 | 0.944 |
Mean propulsive velocity (m/s) | 2.9 ± 3.4 | 0.983 |
Mean propulsive power (W/kg) | 4.5 ± 3.6 | 0.985 |
My Jump Lab | ||
Height (cm) | 5.8 ± 4.6 | 0.981 |
Mean propulsive force (N/kg) | 2.5 ± 2.2 | 0.935 |
Mean propulsive velocity (m/s) | 3.4 ± 4.2 | 0.977 |
Mean propulsive power (W/kg) | 5.3 ± 4.0 | 0.980 |
Bias and LoA | Point Value | Lower 95% CI | Upper 95% CI |
---|---|---|---|
Height (cm) | |||
Mean difference + 1.96 SD | 4.393 | 3.873 | 4.914 |
Mean difference | 0.868 | 0.567 | 1.168 |
Mean difference −1.96 SD | −2.657 | −3.178 | −2.137 |
Mean propulsive force (N/kg) | |||
Mean difference + 1.96 SD | 1.862 | 1.640 | 2.084 |
Mean difference | 0.361 | 0.233 | 0.489 |
Mean difference − 1.96 SD | −1.140 | −1.362 | −0.918 |
Mean propulsive velocity (m/s) | |||
Mean difference + 1.96 SD | 0.102 | 0.090 | 0.114 |
Mean difference | 0.018 | 0.011 | 0.026 |
Mean difference − 1.96 SD | −0.065 | −0.077 | −0.053 |
Mean propulsive power (W/kg) | |||
Mean difference + 1.96 SD | 4.267 | 3.762 | 4.772 |
Mean difference | 0.846 | 0.555 | 1.138 |
Mean difference − 1.96 SD | −2.574 | −3.079 | −2.069 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Balsalobre-Fernández, C.; Varela-Olalla, D. The Validity and Reliability of the My Jump Lab App for the Measurement of Vertical Jump Performance Using Artificial Intelligence. Sensors 2024, 24, 7897. https://doi.org/10.3390/s24247897
Balsalobre-Fernández C, Varela-Olalla D. The Validity and Reliability of the My Jump Lab App for the Measurement of Vertical Jump Performance Using Artificial Intelligence. Sensors. 2024; 24(24):7897. https://doi.org/10.3390/s24247897
Chicago/Turabian StyleBalsalobre-Fernández, Carlos, and Daniel Varela-Olalla. 2024. "The Validity and Reliability of the My Jump Lab App for the Measurement of Vertical Jump Performance Using Artificial Intelligence" Sensors 24, no. 24: 7897. https://doi.org/10.3390/s24247897
APA StyleBalsalobre-Fernández, C., & Varela-Olalla, D. (2024). The Validity and Reliability of the My Jump Lab App for the Measurement of Vertical Jump Performance Using Artificial Intelligence. Sensors, 24(24), 7897. https://doi.org/10.3390/s24247897