Next Article in Journal
On the Modeling of Ship Stiffened Panels Subjected to Uniform Pressure Loads
Previous Article in Journal
Acknowledgment to Reviewers of Applied Mechanics in 2021
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Correction

Correction: Riccio et al. Effects of Curing on Photosensitive Resins in SLA Additive Manufacturing. Appl. Mech. 2021, 2, 942–955

Laboratory of Bio-Inspired Nanomechanics, Department of Structural, Geotechnical and Building Engineering, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy
*
Author to whom correspondence should be addressed.
Appl. Mech. 2022, 3(1), 123-124; https://doi.org/10.3390/applmech3010009
Submission received: 17 January 2022 / Accepted: 24 January 2022 / Published: 28 January 2022
The Authors of the paper “Effects of Curing on Photosensitive Resins in SLA Additive Manufacturing” [1] want to declare the following corrections to their original article.
A first correction has been made in Section 2.3—Test Specimens (Pre- and Post-Curing):
In Table 1, the settings for the Grey Pro resin were reported incorrectly. The correct values should have been 15 min at 80 °C and not 30 min at 60 °C.
Table 1 is enclosed here in its corrected version (the references, included in the original Table 1 and omitted here, can be found in [1]).
A second correction has been made in Section 3.1—Load at Break and Young’s Modulus:
In Table 2, four columns of standard deviation values σ were increased by one decimal place. The last two columns of standard deviation values σ were reported in MPa and not in GPa. The values should have been all divided by 1000.
Table 2 is enclosed here in its corrected version (the references, included in the original Table 2 and omitted here, can be found in [1]).
The Authors apologize for any inconvenience caused by these mistakes. We state that these textual errors did not affect the experimental testing and are inconsequential on the results reported in the remaining parts of the article.
The original article has been updated.

Reference

  1. Riccio, C.; Civera, M.; Ruiz, O.G.; Pedullà, P.; Reinoso, M.R.; Tommasi, G.; Vollaro, M.; Burgio, V.; Surace, C. Effects of Curing on Photosensitive Resins in SLA Additive Manufacturing. Appl. Mech. 2021, 2, 942–955. [Google Scholar] [CrossRef]
Table 1. FormCure settings [4].
Table 1. FormCure settings [4].
ResinTime (min)Temperature (°C)
Tough6060
Standard Clear1560
Grey Pro1580
BioMed Amber3060
Dental LT Clear6060
Tough 15006070
Tough 20006070
Custom Tray3060
High Temp12080
Durable6060
Rigid1580
Table 2. Load at break and Young’s modulus values as obtained for each resin. Comparison between green and post-cure conditions. Mean X ¯ and standard deviation values σ.
Table 2. Load at break and Young’s modulus values as obtained for each resin. Comparison between green and post-cure conditions. Mean X ¯ and standard deviation values σ.
Load at Break (MPa)Young’s Modulus (GPa)
GreenPost-CureGreenPost-Cure
Data SheetExp. ResultsData SheetExp. ResultsData SheetExp. ResultsData SheetExp. Results
Resin X ¯ σ X ¯ σ X ¯ σ X ¯ σ
Tough34.7 [22]23.51.8355.7 [22]30.422.171.7 [22]0.30.032.7 [22]0.60.08
Standard Clear38.0 [23]20.12.1765.0 [23]42.21.911.6 [23]0.70.092.8 [23]1.00.03
Grey Pro35.0 [24]32.25.6861.0 [24]60.41.901.4 [24]0.80.022.6 [24]1.00.03
BioMed AmberN.A. [25]41.21.0473.0 [25]76.84.09N.A. [25]0.80.022.9 [25]1.20.02
Dental LT ClearN.A. [26]34.61.89 50.0 [26]61.810.69N.A. [26]0.60.04 1.3 [26]- (*)- (*)
Tough 150026.0 [27]30.42.6333.0 [27]41.20.960.9 [27]0.40.021.5 [27]0.60.01
Tough 200029.0 [28]26.50.4146.0 [28]42.01.431.2 [28]0.40.042.2 [28]0.80.02
Custom TrayN.A. [29]26.91.98 70.0 [29]84.72.43N.A. [29]0.40.01 2.5 [29]1.10.01
High Temp20.9 [30]26.20.3058.3 [30]48.27.900.8 [30]0.30.012.8 [30]0.80.00
Durable18.6 [31]17.00.7931.8 [31]34.51.340.5 [31]0.20.031.3 [31]0.40.01
BioMed ClearN.A. [32]30.91.8752.0 [32]60.10.55N.A. [32]0.40.022.1 [32]0.90.02
Rigid40.0 [33]39.83.0775.0 [33]74.57.692.2 [33]0.70.024.1 [33]1.30.18
(*) After curing, the Dental LT Clear Resin became fragile to such an extent that it broke during clamping, making the experimental test unfeasible.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Riccio, C.; Civera, M.; Grimaldo Ruiz, O.; Pedullà, P.; Rodriguez Reinoso, M.; Tommasi, G.; Vollaro, M.; Burgio, V.; Surace, C. Correction: Riccio et al. Effects of Curing on Photosensitive Resins in SLA Additive Manufacturing. Appl. Mech. 2021, 2, 942–955. Appl. Mech. 2022, 3, 123-124. https://doi.org/10.3390/applmech3010009

AMA Style

Riccio C, Civera M, Grimaldo Ruiz O, Pedullà P, Rodriguez Reinoso M, Tommasi G, Vollaro M, Burgio V, Surace C. Correction: Riccio et al. Effects of Curing on Photosensitive Resins in SLA Additive Manufacturing. Appl. Mech. 2021, 2, 942–955. Applied Mechanics. 2022; 3(1):123-124. https://doi.org/10.3390/applmech3010009

Chicago/Turabian Style

Riccio, Carmela, Marco Civera, Oliver Grimaldo Ruiz, Perla Pedullà, Mariana Rodriguez Reinoso, Giulia Tommasi, Martina Vollaro, Vito Burgio, and Cecilia Surace. 2022. "Correction: Riccio et al. Effects of Curing on Photosensitive Resins in SLA Additive Manufacturing. Appl. Mech. 2021, 2, 942–955" Applied Mechanics 3, no. 1: 123-124. https://doi.org/10.3390/applmech3010009

Article Metrics

Back to TopTop