Next Article in Journal
Comparing the Performance of the Biathlon Rifles with Wooden and Titanium Frames
Previous Article in Journal
Development of a Feedback System to Control Power in Cycling
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Proceeding Paper

A Study of Skin-Close Heat and Moisture with Different Types of Backpacks in Cycling †

1
Sports Tech Research Centre, Department of Quality Technology and Mechanical Engineering, Mid Sweden University, 83125 Östersund, Sweden
2
Vaude Sports GmbH & Co., I-Team, 88069 Tettnang, Germany
3
Competence Center Sports Engineering, Biomechanics & Ergonomics, University of Applied Sciences Technikum, 1200 Wien, Austria
*
Author to whom correspondence should be addressed.
Presented at the 13th conference of the International Sports Engineering Association, Online, 22–26 June 2020.
Proceedings 2020, 49(1), 86; https://doi.org/10.3390/proceedings2020049086
Published: 15 June 2020

Abstract

:
The aim of this project was to evaluate effects of backpacks with different design intended for use during cycling on skin-close temperature and relative humidity, oxygen uptake, heart rate and aerodynamic drag. Seven subjects took part in the study cycling on a mountain bike mounted on a “smart trainer” placed on a force plate in a wind tunnel. Three series of experiments were carried out: without backpack, with conventional backpack and with a backpack having innovative rear panel design. As hypothesized, the results showed that an innovatively designed backpack with the ducts deflecting part of the airflow towards some areas of the user’s back provided lower temperature and relative humidity for the microclimate compared to a conventional backpack without airflow channels. Further, reference tests without any backpack resulted in the lowest temperature and humidity. However, no differences were found between the three tests for oxygen uptake, heart rate and aerodynamic drag.

1. Introduction

Cycling is one of the most practiced physical activities across the world [1]. Considering the globalization of cycling, major markets for cycling equipment are developing in many hot-weather or tropical locations such as Australia, southern Asia, and the Middle East [2].
Cyclists are often wearing backpacks, especially during longer events like mountain bike (MTB) and bicycle touring or bike commuting. Weder et al. [3] emphasized that wearing a backpack during cycling has a significant impact on athletes’ thermoregulation. However, thermoregulation and skin-close microclimate ((MC) temperature and humidity between skin and first clothing layer) is not only an essential aspect for thermal comfort but also for performance [4], especially in endurance sports such as cycling. Hence, a heat balance represents the major goal for temperature regulation during exercises, especially aiming at avoiding hyperthermia as well as hypothermia [2].
Weder et al. [3] and Klauer et al. [5] experimentally analyzed different backpack systems during cycling in a climate chamber. They concluded that wearing a backpack during cycling affects the MC as well as the interlayer climate ((ILC) temperature and humidity between first clothing layer and midlayer/backpack). Also, corresponding results depended on the tested backpack system. Conventional ventilated backpack systems reduce the temperature (T) and relative humidity (RH) in the MC, as well as in the ILC, compared to full contact backpacks [3,5]. Nevertheless, Klauer and Michel [5] concluded that there is still potential to optimize existing backpack technologies towards better thermal comfort.
Based on these findings [5], the same research group developed a new ventilated backpack design. This technology utilizes the relative headwind that is generated during cycling for an optimized convective heat transfer between the backpack and the first clothing layer. A computational fluid dynamic modeling approach (CFD) of a cyclist without a backpack visualized that the air flow across the shoulders rejoins behind the neck and head of the rider. Here, the air flow speeds up and follows the back surface with the air stream dropping along the spine region [6], where the highest temperature and sweat patterns of the torso are located [7,8,9]. A second air flow path that showed potential to improve convective heat transfer is the one curving around the sides of the torso. Based on these findings, it was suggested that the backpack of novel design should catch the high velocity air flow around the shoulders and neck and guide it towards the spine region. A further CFD analysis of a cyclist wearing a backpack with the new rear panel design confirmed the possibility of utilizing the headwind generated during cycling as a driving force for convective heat transfer. The results of the CFD analysis clearly pointed out that new backpack design features change the airstream pattern, introducing stable air flow between the cyclist’s back and the backpack [6]. However, this CFD study focused only on the air velocity fields and flow patterns as an indication of improved thermal performance and provided no evidence of the concept’s superiority in this area.
Therefore, the main goal of the present study was an experimental investigation of the functionality of the backpack with the new and innovative rear panel design and its comparison to a conventional full contact backpack system. The chosen research approach aimed at testing MC and ILC using recreational cyclists exercising in a climate controlled wind tunnel environment. In addition, the influence of the backpacks on aerodynamic drag and physiological parameters was of interest.

2. Materials and Methods

Seven male subjects (age 34 ± 10 years, body height and weight 1.87 ± 0.05 m and 82.5 ± 7.6 kg) who regularly cycle for exercise participated in the experiments, which were approved by the Regional Ethical Review Board in Umeå, Sweden (Reg. No. 2019/00410). Prior to starting the experiments, the subjects received written information about the study and gave their written consent to participate.
The subjects were cycling on a mountain bike (SC Lite, XXL Europe GmbH, Luzern, Switzerland) with the rear wheel mounted on a “smart trainer” (Flow Smart, Tacx B.V., Wassenaar, The Netherlands), which was placed on a force plate (Kistler 9281EA, Kistler Instrumente AG, Winterthur, Switzerland) in a climatic wind tunnel [10]. The resistance in the “smart trainer” simulated rolling resistance during pedaling, while the aerodynamic drag (FD) acting on the cyclist, together with equipment, was registered by the force plate. A power (P) of 130 watts and wind speed of 5.55 m/s were chosen in order to simulate outdoor conditions with a relatively moderate cycling speed. With an expected mechanical efficiency of ~16%–20%, this would give an energy expenditure of ~720 watts (10.3 kCal/min) and an oxygen uptake ( V ˙ O 2 ) of 2.1 L/min, or 25 mL/kg/min, for a body weight of 82 kg [11].
Three series of tests with the following conditions were performed: (1) without carrying any backpack (WB), (2) carrying a conventional commercial backpack (CB; 16 L, 946 g) belonging to the full contact backpack systems, and (3) carrying a novel backpack having innovative rear panel design (NB; 16 L, 802 g). Figure 1a,c show the rear panels of the two backpacks used in the study. The CB (a) rear panel has four supporting pads (10 mm thick) on each side aligned with the user’s spine. The rear panel of the NB (c) has a number of curved spacing elements (18 mm thick) intended to channel the air flow from the top and the sides of the backpack along the back and spine of the cyclist [8,9].
Each subject was tested at the same time of day on three consecutive days and the order of test conditions was randomized for all subjects. The ambient air temperature (T), relative humidity (RH) and density (ρ) were 18.1 ± 0.8 °C, 13.6% ± 2.7% and 1.14 ± 0.01 kg/m3 during the experiments and were not significantly (p > 0.05) different between the three test conditions. During the tests, all subjects wore the same type of short and thin cycling pants (Vaude Men’s Advanced Pants III, 78% polyamide and 22% elastane), together with a short sleeved cycling shirt (Vaude Men’s Mossano Tricot IV, 100% polyester).
The test protocol duration was 45 min (min), where the first 5 and last 10 min were resting periods when the subjects were sitting on the bike without pedaling and headwind. The cycling was carried out for 30 min between the two resting periods. Due to the relatively moderate workload, there was no need for any warm-up period. The heights of the handlebars and saddle were individually adjusted and were the same for all three test conditions for each subject. The upper body was slightly forward-tilted and supported against the handlebars with relatively straight arms.
The dependent variables were T and RH, measured in MC and ILC, heart rate (HR), V ˙ O 2 , and FD. HR was recorded using a transmitter with electrodes mounted around the subjects chest and a receiver on the wrist (Fenix 5X, Garmin International Inc., Olathe, AR, USA). V ˙ O 2 was measured using an automated metabolic system (Moxus Modular Metabolic System, AEI Technologies, Texas, USA). T and RH were measured with T/RH combined sensors and stored with a mobile data logger (60 Hz, SHT25, Sensiron, MSR147WD, MSR Electronics GmbH, Seuzach, Switzerland). Three sensors were placed on the two backpacks (ILC) at high, medium and low positions (Figure 1a,c). Three sensors were also placed along the spine (MC) at the corresponding positions for the backpacks (Figure 1b). Additionally, one sensor was placed in the MC on the chest in the lower part of the sternum. Thus, in total, four T/RH sensors for test WB and seven sensors for test conditions CB and NB were used. The P and cadence (C) and all dependent variables were compiled as mean for the measured values during 60 s every fifth min throughout the protocol. Recording for T and RH values started from the first min of the protocol, while HR and V ˙ O 2 values were starting on fifth min of the overall test. Recording of P, C and FD values started at the 10th min and ended at 35th min of the tests.

Statistics

The statistical analyses were carried out using SPSS for Windows statistical software release 24.0 (SPSS Inc., Chicago, IL, USA). The test condition variance and time interval variance of P, C, T, RH, HR, V ˙ O 2 and FD where analyzed using two-way ANOVA with repeated measures. The variance of the wind tunnel ambient T, RH and ρ between the three test conditions was analyzed using one-way ANOVA with repeated measures. The Bonferroni post hoc test was used to discern any significant differences found with ANOVA and for adjustments of α for multiple comparisons (p < 0.05). The results are reported as mean value ± standard deviation (SD).

3. Results

Results of averaged values of the three T/RH sensors positioned in the MC along the spine are presented in Figure 2a,b. The statistical analyses showed significant (p < 0.05) differences in T between all three test conditions (WB, CB and NB). A significant difference was also found in RH for CB vs. WB and NB, while there was no difference in RH between WB and NB. Further, there were significant differences in T between different time intervals in the protocol. This occurred for the 1st and 5th min vs. 10th and 15th min and for the 25th, 30th and 35th min vs. 40th and 45th min. Furthermore, significant differences were found in RH for the 1st vs. 10th, 35th, 40th and 45th min; for the 5th, 10th and 15th min vs. 30th, 35th, 40th and 45th min; for the 25th vs. 20th and 30th min and, finally, between the 35th and 40th min.
A mean of the values of all seven sensors, placed in the MC and ILC, for the two test conditions using different backpacks are presented in Figure 3. A significant difference was found in both T and RH between CB and NB. A significant difference was also found for the mean of the ILC sensors separately (results not shown here). Also, significant differences were found in T between different time intervals. This occurred for the 1st min vs. 10th, 15th and 25th min; for the 5th min differences were added vs. 20th and 30th min; for the 40th vs. 25th, 30th and 35th min and, finally, for the 45th min vs. the 10th, 15th, 20th, 25th, 30th and 35th min. As regards RH, significant differences were found for the 1st and 5th min vs. 35th, 40th and 45th min; for the 10th min difference was added vs. the 30th min and for the 15th min also vs. 25th min. Finally, significant differences in RH were also found for the 40th and 45th min vs. all other time intervals.
The results for HR, V ˙ O 2 , P, C and FD are presented in Table 1. There were no significant (p > 0.05) differences between the three test conditions in HR, V ˙ O 2 , P, C and FD. Similarly, there were no differences in P and C between different time intervals during cycling. However, there were significant differences in HR and V ˙ O 2 between the cycling and resting periods, but not within these periods. Finally, there was a small but significant difference in the recorded FD values for the final time interval vs. the three initial ones, but it was probably due to electrical drift in the force plate.

4. Discussion

With regard to the mean value of the three sensors placed in the MC on the subjects back, there was a statistically significant difference in T between all three test conditions. Not surprisingly, average T was lowest without carrying a backpack and lower when wearing the backpack with novel design compared to wearing a backpack of conventional design, see Figure 2a. Further, even when it comes to RH, wearing a backpack of conventional design resulted in the highest values, see Figure 2b. However, there was no statistical difference between the other two test conditions, only a trend to lower RH values for the test without using any backpack. Furthermore, in the paired comparison of mean values for all sensors placed in the MC and ILC, both T and RH were significantly lower for the test using the backpack with innovative rear panel design, see Figure 3a,b. These findings go hand in hand with the results in Weder et al. [3] and Klauer et al. [5].
Regarding the comparison between different time intervals in the protocol, the statistical difference meant a slight decrease in T towards the middle of the protocol, which was systematic for all three test conditions, see Figure 2a. This was followed by a slight increase in T as the protocol went from cycling to resting on the bike. The results for T shown in Figure 3a followed the same pattern, though less evident for the test using the conventional backpack. Further, RH also showed a slight decrease initially, where the protocol went from rest to cycling with headwind. This was followed by a gradual increase during the remaining part of the protocol, where the increase was somewhat greater for the test condition using the conventional backpack, see Figure 2b and Figure 3b. In general, it seems that RH is much more sensitive with reference to the headwind and over time compared to T. Moreover, the measurements also show that there is a certain delay before the sweating starts as a result of the increased energy expenditure and body temperature.
One thing that may have affected the results is that the test conditions already showed different T and RH values in the 1st min. This was because the subjects carried the backpacks for a few minutes before the measurements started, which apparently affected both T and RH in MC and ILC.
The established differences between the test conditions occurred without any differences in HR, V ˙ O 2 , P, C and FD. HR and V ˙ O 2 was ~120 b/min and 24 mL/kg/min, which is approximately 60%–65% of the subjects’ predicted maximal values at their age [11]. Interestingly, there was no difference in FD with and without the use of a backpack. This was also the case between the two tests with different backpacks, even though the differences in T and RH values indicated a presence of air flow between the novel backpack rear panel and the cyclist’s back. Most probably, this was due to the difficulty of detecting small differences in aerodynamic drag over the overall FD from the cyclist, bicycle and “smart trainer”.

5. Conclusions

The conclusion is that this novel approach to the backpack design provides lower temperature and relative humidity in cyclists’ microclimate and interlayer climate as compared to a conventional backpack, which can provide expected improvement of the user’s thermal comfort.

Acknowledgments

The project was conducted with financial support from the EU Regional Development Fund and Swedish Agency for Economic and Regional Growth, Grants No. 20201018 and 20202610.

Conflicts of Interest

The authors declare no conflict of interest. The two authors with affiliation to the company Vaude Sports GmbH are the designers of the backpack with an innovative rear panel design. They had a role in the design of the study and in writing the introduction section, but no role in data collection, compilation and interpretation. In the planning phase of the study all authors have agreed on the decision to publish the results of the study.

References

  1. Desbordes, M. The economics of cycling. In Handbook on the Economics of Sport; Andreff, W., Szymanski, Eds.; Edward Elgar Publishing Limited: Cheltenham, UK, 2006; pp. 398–410. [Google Scholar]
  2. Cheung, S.S. Dealing with heat stress. In Cycling Science; Cheung, S.S., Zabala, M., Eds.; Human Kinetics: Champaign, IL, USA, 2017; pp. 129–141. [Google Scholar]
  3. Weder, M.; Klauer, R.; Michel, F.I.; Breuner, F.; Odenwald, S.; Egli, W. Thermophysiological comfort of cycling backpacks. In Proceedings of the Physiology and Pharmacology of Temperature Regulation—7th International Meeting, Split, Croatia, 7–12 October 2018; p. 40. [Google Scholar]
  4. Ückert, S. Temperatur und Sportliche Leistung; Meyer & Meyer Verlag: Aachen, Germany, 2011. [Google Scholar]
  5. Klauer, R.; Michel, F.I. Thermo-physiological research of micro and interlayer climate during cycling—Influence of two different backpack systems. In Proceedings of the 23rd Annual Congress of the ECSS, Dublin, Ireland, 4–7 July 2018; pp. 203–204. [Google Scholar]
  6. Michel, F.I.; Remmerie, W.; Kimmerle, M. Engineering of a backpack ventilation technology for cycling using CFD analysis. J. Sci. Cycl. 2019, 8, 5–8. [Google Scholar] [CrossRef]
  7. Michel, F.I.; Schneider, N.; Lachner, M.; Klauer, R.; Emrich, F.; Wouter, R. Influence of an engineered backpack ventilation technology on thermal comfort during cycling—A pilot study. JSC 2019, 8, 9–12. [Google Scholar]
  8. Harnisch, M.; Katz, B. Verbesserung der Physiologischen Funktion von Sportkleidung durch Komfortzonen; AiF-research report no. 15720 N; Hohenstein Institut fur Textilinnovation e.V.: Bönnigheim, Germany, 2010. [Google Scholar]
  9. Smith, C.J.; Havenith, G. Body mapping of sweating patterns in male athletes in mild exercise-induced hyperthermia. Eur. J. Appl. Physiol. 2011, 111, 1391–1404. [Google Scholar] [CrossRef] [PubMed]
  10. Ainegren, M.; Tuplin, S.; Carlsson, P.; Render, P. Design and development of a climatic wind tunnel for physiological sports experimentation. J. Sports Eng. Tech. 2019, 233, 86–100. [Google Scholar] [CrossRef]
  11. McArdle, W.D.; Katch, F.I.; Katch, V.L. Exercise Physiology, 7th ed.; Lippincott Williams & Wilkins: Philadelphia, PA, USA, 2010; pp. 208–473. [Google Scholar]
Figure 1. The two types of backpack used in the study: (a) conventional backpack; (c) backpack having an innovative rear panel design. (b) and (c) illustrate the positioning of three combined temperature and humidity sensors placed skin-close (microclimate) along the spine and at corresponding positions on the backpacks (interlayer climate).
Figure 1. The two types of backpack used in the study: (a) conventional backpack; (c) backpack having an innovative rear panel design. (b) and (c) illustrate the positioning of three combined temperature and humidity sensors placed skin-close (microclimate) along the spine and at corresponding positions on the backpacks (interlayer climate).
Proceedings 49 00086 g001
Figure 2. Temperature (a) and relative humidity (b) for the three test conditions at different time intervals during the protocol. Mean ± SD of the three sensors placed in the microclimate along the spine.
Figure 2. Temperature (a) and relative humidity (b) for the three test conditions at different time intervals during the protocol. Mean ± SD of the three sensors placed in the microclimate along the spine.
Proceedings 49 00086 g002
Figure 3. The overall mean results from all temperature (a) and humidity (b) sensors placed in the microclimate and interlayer climate for the two test conditions using different backpacks. Mean ± SD.
Figure 3. The overall mean results from all temperature (a) and humidity (b) sensors placed in the microclimate and interlayer climate for the two test conditions using different backpacks. Mean ± SD.
Proceedings 49 00086 g003
Table 1. Heart rate (HR), oxygen uptake V ˙ O 2 , power (P), cadence (C) and aerodynamic drag (FD) for the three test conditions at selected time intervals during the test protocol. Mean ± SD.
Table 1. Heart rate (HR), oxygen uptake V ˙ O 2 , power (P), cadence (C) and aerodynamic drag (FD) for the three test conditions at selected time intervals during the test protocol. Mean ± SD.
Time
(min)
Test
Condition
HR
(b/min)
V ˙ O 2
(L/min)
P
(watt)
C
(r/min)
FD
(N)
5th WB66.2 ± 10.80.28 ± 0.12
CB69.3 ± 12.10.28 ± 0.07
NB69.2 ± 11.20.28 ± 0.05
10thWB111.7 ± 19.21.95 ± 0.06129.0 ± 0.977.1 ± 7.110.9 ± 0.6
CB121.0 ± 21.12.02 ± 0.14129.4 ± 0.480.2 ± 6.510.3 ± 0.4
NB119.0 ± 23.81.90 ± 0.13129.5 ± 0.382.1 ± 6.410.3 ± 0.5
15thWB120.6 ± 20.71.95 ± 0.05128.3 ± 2.681.2 ± 5.610.9 ± 0.7
CB123.5 ± 23.22.03 ± 0.15129.1 ± 0.681.4 ± 7.310.5 ± 0.6
NB116.4 ± 34.52.02 ± 0.18129.5 ± 0.283.4 ± 6.010.3 ± 0.5
20thWB120.2 ± 21.61.95 ± 0.05128.9 ± 1.380.8 ± 6.611.1 ± 0.6
CB123.0 ± 24.11.98 ± 0.14129.2 ± 0.582.1 ± 6.910.5 ± 0.5
NB122.6 ± 27.02.00 ± 0.25129.4 ± 0.283.6 ± 5.810.4 ± 0.7
25thWB121.2 ± 22.52.00 ± 0.11128.9 ± 1.581.4 ± 7.211.3 ± 0.7
CB124.1 ± 24.02.00 ± 0.18129.5 ± 0.382.0 ± 6.1 10.7 ± 0.5
NB122.7 ± 27.11.98 ± 0.25129.5 ± 0.283.3 ± 5.910.7 ± 0.9
30thWB121.8 ± 23.81.98 ± 0.16129.1 ± 0.982.3 ± 7.711.3 ± 0.6
CB123.6 ± 24.42.01 ± 0.14129.4 ± 0.483.3 ± 6.610.9 ± 0.5
NB123.0 ± 27.02.01 ± 0.22129.5 ± 0.183.7 ± 5.7 10.6 ± 0.9
35thWB123.0 ± 23.42.01 ± 0.07129.1 ± 1.381.7 ± 8.411.5 ± 0.4
CB123.7 ± 25.71.97 ± 0.22129.4 ± 0.282.8 ± 6.211.1 ± 0.6
NB124.1 ± 27.51.96 ± 0.22129.6 ± 0.283.9 ± 6.311.0 ± 1.0
40thWB81.2 ± 16.80.29 ± 0.05
CB79.5 ± 20.00.33 ± 0.09
NB81.5 ± 18.30.33 ± 0.06
45thWB73.0 ± 16.7 0.27 ± 0.04
CB78.6 ± 21.70.29 ± 0.06
NB76.4 ± 17.60.32 ± 0.04
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Ainegren, M.; Michel, F.I.; Klauer, R.; Koptyug, A.; Bäckström, M.; Samuelsson, D.; Ahnesjö, M.; Litzenberger, S. A Study of Skin-Close Heat and Moisture with Different Types of Backpacks in Cycling. Proceedings 2020, 49, 86. https://doi.org/10.3390/proceedings2020049086

AMA Style

Ainegren M, Michel FI, Klauer R, Koptyug A, Bäckström M, Samuelsson D, Ahnesjö M, Litzenberger S. A Study of Skin-Close Heat and Moisture with Different Types of Backpacks in Cycling. Proceedings. 2020; 49(1):86. https://doi.org/10.3390/proceedings2020049086

Chicago/Turabian Style

Ainegren, Mats, Frank I. Michel, Robert Klauer, Andrey Koptyug, Mikael Bäckström, David Samuelsson, Magnus Ahnesjö, and Stefan Litzenberger. 2020. "A Study of Skin-Close Heat and Moisture with Different Types of Backpacks in Cycling" Proceedings 49, no. 1: 86. https://doi.org/10.3390/proceedings2020049086

Article Metrics

Back to TopTop