Next Article in Journal
Sources of Bathing Water Pollution in the West Coast of Tangier, Morocco: Effects of Industrial Zones
Previous Article in Journal
Studies of the Cationic Polyacrylamide Adsorption on the Montmorillonite Surface in the Presence of Lead(II) Ions
 
 
Retraction published on 27 July 2021, see Proceedings 2019, 16(1), 60.
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Proceeding Paper

RETRACTED: Analysis of Various Ventilation Systems Due to the Quality of Indoor Air in Educational Buildings †

by
Katarzyna Gładyszewska-Fiedoruk
1,*,
Vasyl Zhelykh
2 and
Andrii Pushchinskyi
2
1
Department of HVAC Engineering, Bialystok University of Technology, 15-351 Bialystok, Poland
2
HGSV Department, Lviv Polytechnic National University, 79013 Lviv, Ukraine
*
Author to whom correspondence should be addressed.
Presented at Innovations-Sustainability-Modernity-Openness Conference (ISMO’19), Bialystok, Poland, 22–23 May 2019.
Proceedings 2019, 16(1), 29; https://doi.org/10.3390/proceedings2019016029
Published: 3 July 2019
(This article belongs to the Proceedings of Innovations-Sustainability-Modernity-Openness Conference (ISMO’19))

Abstract

The quality of internal air is one of the factors that affect the pace and quality of knowledge acquisition. Therefore, it is important that the classrooms have high air quality. Using computer simulation, the effect of various building ventilation variants on air quality in classrooms was analyzed. As an indicator of air quality, the concentration of carbon dioxide in school halls was assumed.
Keywords: indoor air quality; ventilation systems; indoor microclimate; air stream; concentration of carbon dioxide indoor air quality; ventilation systems; indoor microclimate; air stream; concentration of carbon dioxide

Share and Cite

MDPI and ACS Style

Gładyszewska-Fiedoruk, K.; Zhelykh, V.; Pushchinskyi, A. RETRACTED: Analysis of Various Ventilation Systems Due to the Quality of Indoor Air in Educational Buildings. Proceedings 2019, 16, 29. https://doi.org/10.3390/proceedings2019016029

AMA Style

Gładyszewska-Fiedoruk K, Zhelykh V, Pushchinskyi A. RETRACTED: Analysis of Various Ventilation Systems Due to the Quality of Indoor Air in Educational Buildings. Proceedings. 2019; 16(1):29. https://doi.org/10.3390/proceedings2019016029

Chicago/Turabian Style

Gładyszewska-Fiedoruk, Katarzyna, Vasyl Zhelykh, and Andrii Pushchinskyi. 2019. "RETRACTED: Analysis of Various Ventilation Systems Due to the Quality of Indoor Air in Educational Buildings" Proceedings 16, no. 1: 29. https://doi.org/10.3390/proceedings2019016029

APA Style

Gładyszewska-Fiedoruk, K., Zhelykh, V., & Pushchinskyi, A. (2019). RETRACTED: Analysis of Various Ventilation Systems Due to the Quality of Indoor Air in Educational Buildings. Proceedings, 16(1), 29. https://doi.org/10.3390/proceedings2019016029

Article Metrics

Back to TopTop